Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 16 de 16
1.
Am J Cardiol ; 86(4A): 53G-56G, 2000 Aug 17.
Article En | MEDLINE | ID: mdl-10997357

The acute dissection of the ascending aorta requires prompt and reliable diagnosis to reduce the high risk of mortality; in addition, prognosis is influenced by long-term complications. The aim of this article is to discuss transesophageal echocardiography (TEE) and (1) its diagnostic accuracy in the presurgical evaluation of patients, (2) its role in reducing time of diagnosis and surgery, and (3) its ability to reduce hospital mortality. TEE has also been tested as a screening method in the postsurgical follow-up of these patients. The retrospective investigation concerns a sample of 80 cases of acute dissection of the aorta, submitted for surgical intervention from April 1986 to February 1999. TEE has allowed a precise estimation of aortic diameters and optimal visualization of intimal flap and tear entry with a fine distinction between true and false lumen. A direct comparison of the results of TEE and of transthoracic echocardiography has demonstrated that some elements (visualization of flap and diameters in descending aorta, sites of entry and reentry, direction of jet trough intimal tears, phasic intimal flap movement, diastolic collapse of flap on the valvular plane, false lumen thrombosis, coronary involvement, intramural hematoma, and aortic fissuration) were identified only by TEE, whereas other additional diagnostic elements (cardiac tamponade, aortic valve insufficiency, left ventricular function) show a similar pattern of significance. Routine employment of this method has confirmed a reduction of hospitalization time (about 1.5 hours of waiting time), and hospital mortality has changed from 42.8% to 17.3%. In the follow-up of patients operated on for aortic dissection, fundamental information may be obtained from TEE (assessment of the progression of thrombosis in the false lumen with its complete obliteration and modifications in aortic diameter with a consequent, possible worsening of aortic valve insufficiency). In conclusion, our study demonstrated that TEE may provide fast and efficient detection of acute aortic dissection. In the postsurgical follow-up, TEE has confirmed detection of major complications that can influence long-term prognosis and may be proposed as a method with easy access-one that is repeatable and inexpensive for the screening of aortic dissection surgical patients.


Aortic Aneurysm/diagnostic imaging , Aortic Dissection/diagnostic imaging , Echocardiography, Transesophageal , Aortic Dissection/mortality , Aortic Aneurysm/mortality , Echocardiography/methods , Hospital Mortality , Humans , Predictive Value of Tests , Sensitivity and Specificity , Thorax/diagnostic imaging , Time Factors
2.
G Ital Cardiol ; 28(10): 1083-93, 1998 Oct.
Article En | MEDLINE | ID: mdl-9834859

OBJECTIVES: This study was undertaken: 1) to assess the efficacy of traditional PTCA in affording "optimal" initial dilatation (OID) of coronary stenoses (as assessed by on-line quantitative angiography) defined as a post-procedure residual lumen narrowing < or = 20%; 2) to determine clinical and angiographic correlates of these types of successes. BACKGROUND: Recent reports have shown that acute angiographic results achieved by traditional PTCA, resembling those obtainable by elective stenting, carry low risks of restenosis. However, safety and the ability of conventional PTCA to consistently provide acute stent-like results are still practically unknown. PATIENTS AND METHODS: Using a "standardized" procedural protocol intended to optimize acute angiographic results, 878 consecutive non-selected patients, 750 men and 128 women aged 29-78 years (mean 60.5 yrs) underwent PTCA on 1054 lesions. Compliant balloons reaching nominal dimensions at 6 atm and predicted balloon-artery ratios of 0.92-1.05 (mean 1.02) were used. An inflation pressure of 5 atm was gradually and slowly applied initially (usually sufficient to reach the point of plaque fracture). Inflation times of 60 seconds and step-increases in inflation pressure of 1 atm were subsequently utilized, until a large lumen with smooth contours (the nearest to normal) or any wall damage were detected by angiographic tests performed at each step. Inflations were stopped when, even in the presence of sub-optimal dilatation, the inflation pressure of 14 atm was reached (which usually corresponded to an effective balloon/artery ratio < 1.15). RESULTS: Overall traditional primary successes were 830 (94.5%) for patients and 1001 (95%) for lesions. Major complications, without mortality, were 24 (2.7%). CABS was necessary in 17 patients (1.9%) while acute myocardial infarction occurred in 7 patients (0.8%). OID was obtained in 65.4% of the treated lesions: 77.9% in type A, 73.9% in B1, 54.0% in B2 and 32.5% in C lesion subgroups of the AHA/ACC classification scheme. Multivariate analysis showed that no clinical variables significantly influenced OID. Lesion-related variables such as chronic occlusion, diffuse disease, length > 10 mm, heavily calcified and markedly angulated lesions emerged as (negative) determinants of success. CONCLUSIONS: Acute stent-like angiographic results are obtainable by conventional PTCA in a consistent percentage of eligible coronary lesions. Following a safe modality of balloon-stress application in performing angioplasty, probability of safely achieving OID of coronary stenoses is related to specific angiographic lesion characteristics.


Angioplasty, Balloon, Coronary , Coronary Angiography , Coronary Disease/diagnostic imaging , Coronary Disease/therapy , Adult , Aged , Angioplasty, Balloon, Coronary/adverse effects , Female , Humans , Male , Middle Aged , Treatment Outcome
4.
G Ital Cardiol ; 27(7): 645-53, 1997 Jul.
Article En | MEDLINE | ID: mdl-9282284

BACKGROUND AND OBJECTIVE: Elective native coronary artery stenting has shown its efficacy in lowering restenosis rates (RR) usually occurring after balloon angioplasty (PTCA). However ability of conventional PTCA to consistently provide low RR, through the achievement of large acute stent-like angiographic results, has not been investigated. This study was conducted to: (1) assess ability of optimal initial dilatation (OID), defined by residual lumen narrowing < or = 20%, significantly reduce current high RR following traditional PTCA; (2) evaluate the efficacy of OID obtainable by conventional PTCA in influencing adverse effects of single variables predisposing to restenosis. METHODS: Of consecutive 601 patients who underwent PTCA, 569 (94.6%), 483 men and 86 women, aged 38-76 years, had a successful procedure on 645/678 lesions (95.1%). After a plaque fracture was obtained by the first inflation, step-increases in pressure of 1 atm and 60 second-inflation-times were applied, until a large lumen (the nearest to normal) and smooth contours were seen, or any wall damage detected by using step-by-step angiographic tests. Acute optimal results (group A) were 450 (69.7%) and sub-optimal results (group B) were 203 (30.3%). After a mean time of 9 +/- 1.8 months, 543 patients (95.4%) had angiographic restudy on 611 (94.7%) successfully treated lesions. RESULTS: Restenosis (> 50% stenosis at restudy) occurred in 27.1% of patients and in 24.5% of lesions. RR was 18.8% in group A and 37.8% in group B (p < 0.0001). Significant lower RR were observed in group A in comparison with group B, for single variables examined, except for length > 10 mm. By multivariate analysis of all treated lesions, sub-optimal initial dilatation, unstable angina, lesion length > 10 mm and eccentricity emerged as major determinants of restenosis. Following OID only length > 10 mm was highly predictive of this event and, in the absence of this adverse variable, RR was only 13.6%. CONCLUSION: Counterbalancing adverse effects of many variables predisposing to restenosis, OID obtained by traditional PTCA seem to significantly reduce the risk of recurrence, particularly in lesions no longer than 10 mm.


Angioplasty, Balloon, Coronary , Coronary Disease/therapy , Stents , Adult , Aged , Coronary Angiography , Coronary Disease/diagnostic imaging , Coronary Disease/prevention & control , Female , Humans , Male , Middle Aged , Recurrence , Risk Factors
6.
Eur J Radiol ; 20(3): 224-8, 1995 Sep.
Article En | MEDLINE | ID: mdl-8536756

Magnetic resonance imaging (MRI) has been frequently considered unsafe for patients with ferromagnetic implants: risks to be considered include induction of electric current, heating and dislocation of the prosthesis. Previous in vitro and in vivo studies have indicated the possibility of performing MRI examinations on patients with prosthetic heart valves. The aim of our study was to verify the presence of artifacts at the level of the prosthetic heart valve in vivo using a low-field MR unit (0.2 T) and to define the possibility of a functional analysis of the valve in patients with biomedical or mechanical prostheses. We evaluated 14 patients surgically treated for implantation of nine biological and seven mechanical aortic and mitral valves. A low-field MR unit (0.2 T) was employed using cine-MR technique on long- and short-axis view. The images were acquired on planes parallel and perpendicular to the valvular plane. Semiquantitative analysis with double-blind evaluation for definition of the extent of the artifact was performed. Three classes of artifacts were distinguished from minimal to significant. The examinations showed the presence of minimal artifacts in all biological heart valves and moderate artifacts in mechanical valves giving good qualitative data on blood flow near the valve. Analysis of the flow behind the valve showed signs of normal function in 13 prostheses and pathological findings in the remaining three. In these latter cases, MRI was able to define the presence of a pathologic aortic pressure gradient, mitral insufficiency and malpositioning of the mitral valve causing subvalvular turbulence. Nevertheless, we believe that the application of velocity-encoding cine-MR is more promising than semiquantitative analysis of artifacts.


Aortic Valve/physiology , Heart Valve Prosthesis , Magnetic Resonance Imaging, Cine , Mitral Valve/physiology , Adult , Aortic Valve/diagnostic imaging , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/diagnostic imaging , Artifacts , Bioprosthesis , Blood Pressure , Double-Blind Method , Echocardiography , Evaluation Studies as Topic , Female , Hemorheology , Humans , Magnetic Resonance Imaging, Cine/methods , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/diagnostic imaging , Prosthesis Design , Prosthesis Failure , Regional Blood Flow , Risk Factors , Safety
7.
Cardiologia ; 38(10): 635-42, 1993 Oct.
Article It | MEDLINE | ID: mdl-8111756

We have studied the relationship between left ventricular segmental wall motion evaluated by means of biplane left ventricular cineangiography and the myocardial infarct size estimated using Selvester's scoring system based on the QRS of the electrocardiogram. Seventy consecutive patients with old myocardial infarction were recruited. All patients underwent diagnostic retrograde left heart catheterization including left ventriculography and selective coronary arteriography. Nineteen patients were excluded from the study due to intraventricular conduction disturbances and left ventricular hypertrophy. Of the remaining 51 patients, aged 33-76 years (mean 56 years), 31 had inferior or postero-inferior myocardial infarction (Group 1); 7 patients had combined anterior and inferior myocardial infarction (Group 2); 13 patients had anterior or antero-septal myocardial infarction (Group 3). The analysis of left ventricular segmental wall motion was performed according to the Collaborative Studies in Coronary Artery Surgery assigning at hypokinesia, akinesia and dyskinesia 1, 2 and 3 points, respectively. The values of statistical correlations between QRS scoring system and ventricular scoring were: r = 0.85 (Group 1); r = 0.78 (Group 2); r = 0.70 (Group 3). Our data indicate that Selvester's scoring system may provide useful information on functional status and on the extent of left ventricular wall motion abnormalities in patients with previous myocardial infarction.


Electrocardiography/methods , Myocardial Infarction/physiopathology , Ventricular Function, Left , Adult , Aged , Cardiac Catheterization , Coronary Angiography , Electrocardiography/statistics & numerical data , Female , Humans , Linear Models , Male , Middle Aged , Myocardial Infarction/diagnosis , Myocardial Infarction/epidemiology , Time Factors
9.
Cardiologia ; 35(1): 73-8, 1990 Jan.
Article It | MEDLINE | ID: mdl-2376056

Magnetic resonance (MR) imaging provides detailed evaluation of cardiovascular structures, due to high intrinsic contrast between flowing blood and vessel's lumen. Early application have shown the clinical validity of the technique, with non-invasive, multiplanar imaging of large and medium sized vessels. In this study we evaluate the capabilities of MR in screening out patients with thoracic aorta enlargement. Examination has been performed in 16 patients, employing a 0.5 T superconductive unit, and acquiring images on axial, sagittal and coronal planes with 7 mm slice thickness. In 15 cases it was possible to detect the pathology and to characterize it according to type, location and extension. In 1 case it was no possible to make an accurate diagnosis for the presence of movement artefacts, due to poor patient's cooperation. In dissecting aneurysms the true and false lumen may be differentiated, with a good visualization of the intimal flap. The relation between the origin of the aortic branches and the aneurysm may also be ascertained.


Aortic Diseases/diagnosis , Magnetic Resonance Imaging , Adult , Aged , Aorta, Thoracic , Aortic Aneurysm/diagnosis , Dilatation, Pathologic/diagnosis , Female , Humans , Male , Middle Aged
10.
J Cardiovasc Surg (Torino) ; 30(4): 709-12, 1989.
Article En | MEDLINE | ID: mdl-2777879

Anomalous origin of one pulmonary artery from the ascending aorta without associated intracardiac defects is a rare congenital malformation. About 60 anatomic and surgical descriptions have been reported in the literature. Up to 1974, 22 of the 50 reported cases underwent surgical correction with a 40% mortality rate. The natural history without surgery is poor with a very high mortality during the first year of life. Successful anatomic correction of anomalous origin of right pulmonary artery from the ascending aorta in a 6 months old female is reported.


Aorta/abnormalities , Pulmonary Artery/abnormalities , Anastomosis, Surgical , Aorta/surgery , Female , Humans , Infant , Pulmonary Artery/surgery
12.
G Ital Cardiol ; 17(11): 992-4, 1987 Nov.
Article En | MEDLINE | ID: mdl-3446572

Clinical, instrumental and post-mortem studies were carried out in a patient with intractable cardiac failure, whose death was attribute to Weil's syndrome. A post-mortem examination showed the presence of numerous petechiae on the heart layers and diffuse lymphomonocytic infiltrates in the myocardium, epicardium and endocardium. We suggest that in patients affected by leptospirosis--an endemic disease with a possible fatal outcome--it is necessary to determine carefully any involvement of the cardiovascular system which may play a determinant role in the evolution of the disease.


Heart Failure/etiology , Weil Disease/complications , Heart Failure/pathology , Humans , Male , Middle Aged , Myocardium/pathology , Weil Disease/pathology
...