Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
2.
World J Cardiol ; 15(9): 415-426, 2023 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-37900261

RESUMEN

Cardiac magnetic resonance (CMR) imaging could enable major advantages when guiding in real-time cardiac electrophysiology procedures offering high-resolution anatomy, arrhythmia substrate, and ablation lesion visualization in the absence of ionizing radiation. Over the last decade, technologies and platforms for performing electrophysiology procedures in a CMR environment have been developed. However, performing procedures outside the conventional fluoroscopic laboratory posed technical, practical and safety concerns. The development of magnetic resonance imaging compatible ablation systems, the recording of high-quality electrograms despite significant electromagnetic interference and reliable methods for catheter visualization and lesion assessment are the main limiting factors. The first human reports, in order to establish a procedural workflow, have rationally focused on the relatively simple typical atrial flutter ablation and have shown that CMR-guided cavotricuspid isthmus ablation represents a valid alternative to conventional ablation. Potential expansion to other more complex arrhythmias, especially ventricular tachycardia and atrial fibrillation, would be of essential impact, taking into consideration the widespread use of substrate-based strategies. Importantly, all limitations need to be solved before application of CMR-guided ablation in a broad clinical setting.

3.
Eur Heart J Case Rep ; 7(8): ytad370, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37575541

RESUMEN

Background: Cavotricuspid isthmus pulsed-field ablation has been recently described to be safely performed despite initial reports on coronary arterial spasm while conduction disturbances as a complication of cavotricuspid isthmus ablation are rare and have been reported exclusively for radiofrequency catheter ablation. Case summary: A 64-year-old female patient with mechanical prosthetic valves underwent atrial fibrillation ablation using the pentaspline pulsed-field ablation catheter. At the end of the uneventful pulmonary vein isolation, an atrial tachycardia depended to the cavotricuspid isthmus occurred. A single pulsed-field application at the cavotricuspid isthmus resulted in right bundle branch block combined with posterior fascicular hemiblock and PR prolongation that resolved spontaneously within 12 h. Discussion: This is the first report of transient conduction disturbances as a complication of cavotricuspid isthmus pulsed-field ablation. Although the underlying mechanism, either single or miscellaneous, was not verified, this case highlights that caution should be taken when the pentaspline pulsed-field ablation catheter is used for cavotricuspid isthmus ablation.

7.
Surg Radiol Anat ; 43(3): 311-316, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33221970

RESUMEN

PURPOSE: We describe angiographic findings of sinus node arteries (SNAs), focusing in the large sinus node artery (LSNA) variants, regarding the blood supply of the SN and atrial myocardium. METHODS: We examined the SN arteries via postmortem angiographic visualization in six hundred hearts derived from victims of various accidents. RESULTS: The main stem or a branch of the SNA supplied the right atrium (RA) and part of the interatrial septum (IS) in 32% of cases (Group A), one atrium, the IS and a small part of the other atrium (Group B) in 39% and the entire atrial myocardium (LSNAs) (Group C) in 29%. Forty-two percent (42%) of LSNAs were arising from the anterior part of the right coronary artery (RCA) (type 1), 9% from its intermediate part (type 2) and 49% from the posterolateral portion of the left circumflex artery (LCx) (type 3). Type 2 can be injured by surgical procedures, type 3 by interventional ones, while type 1 is not affected by any. The SN area was supplied in Groups A and B by the main stem of SN arteries in 370 cases (62%) and by branches (Br) in 55 (9%). The 175 cases of group C (29%) were supplied only by branches. The clockwise (40% of cases) and counterclockwise rotations (60%) of the SNA around the superior vena cava, concern surgical procedures. CONCLUSION: The above findings are essential for every day surgical and interventional procedures.


Asunto(s)
Variación Anatómica , Vasos Coronarios/anatomía & histología , Atrios Cardíacos , Miocardio , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cadáver , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
9.
Cardiology ; 135(4): 236-239, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27529552

RESUMEN

Radiofrequency ablation is the therapy of choice for the suppression of medically intractable symptomatic ventricular arrhythmias. Here we present the case report of a 50-year-old woman with bicuspid aortic valve (BAV) and symptomatic nonsustained ventricular tachycardia arising from the left ventricular outflow tract (LVOT). The origin of the ventricular arrhythmia was confirmed in the left coronary cusp (LCC) of the BAV. The patient underwent a successful radiofrequency ablation. LCC of a tricuspid aortic valve is a common origin of idiopathic LVOT tachycardia; however, little is known for these types of arrhythmias when located in the cusps of a BAV.


Asunto(s)
Válvula Aórtica/anomalías , Ablación por Catéter , Enfermedades de las Válvulas Cardíacas/complicaciones , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Enfermedad de la Válvula Aórtica Bicúspide , Femenino , Humanos , Persona de Mediana Edad
11.
Am J Cardiol ; 117(6): 935-9, 2016 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-26796192

RESUMEN

Right bundle branch block (RBBB) configuration is an unexpected finding during right ventricular (RV) pacing that raises the suspicion of inadvertent left ventricular lead positioning. The aim of this study was to evaluate the prevalence of paced RBBB pattern in relation to RV lead location. This is a secondary analysis of a prospective, multicenter study, which randomized implantable cardioverter defibrillator recipients to an apical versus midseptal defibrillator lead positioning. A 12-lead electrocardiogram was recorded during intrinsic rhythm and RV pacing. Paced RBBB-like pattern was defined as positive (>0.05 mV) net amplitude of QRS complex in leads V1 and/or V2. In total, 226 patients (65.6 ± 12.0 years, 20.8% women, 53.1% apical site) were included in the study. The prevalence of paced RBBB pattern in the total population was 15.5%. A significantly lower percentage of patients in the midseptal group demonstrated RBBB-type configuration during RV pacing compared with the apical group (1.9% vs 27.5%, p <0.001). Baseline RBBB, prolonged QRS duration during intrinsic rhythm, and reduced ejection fraction were not associated with increased likelihood of paced RBBB. In the subgroup of patients with RBBB type during pacing, 91.4% of patients had a paced QRS axis from -30° to -90°, whereas 100% of patients displayed a negative QRS vector at lead V3. In conclusion, RBBB configuration is encountered in a considerable percentage of device recipients during uncomplicated RV pacing. Midseptal lead positioning is associated with significantly lower likelihood of paced RBBB pattern compared with apical location.


Asunto(s)
Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Desfibriladores Implantables/efectos adversos , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos , Marcapaso Artificial/efectos adversos , Anciano , Bloqueo de Rama/etiología , Complicaciones de la Diabetes/fisiopatología , Complicaciones de la Diabetes/terapia , Electrocardiografía , Femenino , Alemania/epidemiología , Grecia/epidemiología , Humanos , Hipertensión/complicaciones , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/terapia , Prevalencia , Estudios Prospectivos , Proyectos de Investigación , Factores de Riesgo , Resultado del Tratamiento
12.
World J Cardiol ; 7(2): 76-85, 2015 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-25717355

RESUMEN

Flecainide acetate is a class IC antiarrhythmic agent and its clinical efficacy has been confirmed by the results of several clinical trials. Nowadays, flecainide is recommended as one of the first line therapies for pharmacological conversion as well as maintenance of sinus rhythm in patients with atrial fibrillation and/or supraventricular tachycardias. Based on the Cardiac Arrhythmia Suppression Trial study results, flecainide is not recommended in patients with structural heart disease due to high proarrhythmic risk. Recent data support the role of flecainide in preventing ventricular tachyarrhythmias in patients with catecholaminergic polymorphic ventricular tachycardia associated both with ryanodine receptor and calsequestrin mutations. We herein review the current clinical data related to flecainide use in clinical practice and some concerns about its role in the management of patients with coronary artery disease.

13.
World J Cardiol ; 6(12): 1270-7, 2014 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-25548617

RESUMEN

Cardiac resynchronization therapy (CRT) effected via biventricular pacing has been established as prime therapy for heart failure patients of New York Heart Association functional class II, III and ambulatory IV, reduced left ventricular (LV) function, and a widened QRS complex. CRT has been shown to improve symptoms, LV function, hospitalization rates, and survival. In order to maximize the benefit from CRT and reduce the number of non-responders, consideration should be given to target the optimal site for LV lead implantation away from myocardial scar and close to the latest LV site activation; and also to appropriately program the device paying particular attention to optimal atrioventricular and interventricular intervals. We herein review current data related to both optimal LV lead placement and device programming and their effects on CRT clinical outcomes.

14.
Int J Cardiol ; 177(3): 977-81, 2014 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-25449510

RESUMEN

BACKGROUND: Electrocardiographic (ECG) identification of prior myocardial infarction (MI) during right ventricular (RV) pacing is of clinical importance. Proposed ECG criteria have been evaluated only during apical pacing. We evaluated the effect of pacing site on the predictive performance of ECG signs of prior MI. METHODS: The present study is a secondary analysis of a prospective, multicenter study which randomized recipients of an implantable cardioverter defibrillator to an apical versus septal RV lead positioning. ECGs of patients with or without prior MI were analyzed for the presence of the following criteria: Cabrera sign, Chapman sign, QR pattern in leads I, aVL, V5 or V6, QR in inferior leads and notching in the descending slope of the QRS complex in inferior leads. RESULTS: The MI group included 89 patients (55.1% apically paced), while 99 patients had no prior MI (50.5% apically paced). In the total population, the Cabrera sign presented the highest specificity (97%) and diagnostic accuracy (62.2%), with a sensitivity of 23.6%. The Cabrera sign was the only significant predictor of a prior MI [OR=9.9, (95%CI:2.8-34.5), p<0.001], among all ECG markers. Pacing site did not significantly influence the sensitivity and specificity of the Cabrera sign for detection of prior MI. CONCLUSIONS: In our study, the Cabrera sign was the only ECG marker that predicted the presence of prior MI during ventricular paced rhythm. Septal RV lead positioning did not affect the predictive performance of the Cabrera sign.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/fisiopatología , Tabique Interventricular/fisiopatología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/terapia , Estudios Prospectivos
15.
Hellenic J Cardiol ; 55(4): 281-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25039023

RESUMEN

BACKGROUND: Although atrial fibrillation (AF) is a highly prevalent health problem with high morbidity and mortality, data regarding the clinical characteristics and management of AF in the Greek population are scarce. The "Current Clinical Practice in the MANAGEment of Atrial Fibrillation in Greece" study (MANAGEAF) aimed to assess the epidemiological features as well as the daily clinical practice in the management of Greek patients with AF. METHODS: Taking into consideration the distribution of the Greek population, 603 consecutive patients over 18 years of age, with any type of AF, presenting at the emergency departments or outpatient clinics of 27 different centers, were included in our study. RESULTS: The mean age of the patients was 68.5 ± 12.1 years, with male patients representing 52.5% of the study population. The most common AF type in our cohort was non-paroxysmal AF (60%), including the patients with permanent (24.1%), persistent (17.4%), long-standing (4.8%) and first diagnosed AF (13.8%). Hypertension was the most common comorbidity (70.3%). A history of stroke or transient ischemic attack was detected in 9.2% of the patients, while 6.2% had a history of gastrointestinal bleeding. About half of the patients (49.3%) were treated with anticoagulant drugs, mainly vitamin K antagonists (46.9%), while 34.2% were on antiplatelet drugs, aspirin and/or clopidogrel. The mean INR level (1.7 ± 0.8) was sub-therapeutic, although the mean values for CHADS2 and CHA2DS2-VASc scores were 1.6 ± 1.2 and 3.0 ± 1.7, respectively. CONCLUSION: The MANAGE-AF baseline results indicate unsatisfactory levels of compliance with the current guidelines for the management of AF in Greece. Considering the undisputed effectiveness of anticoagulant treatment for preventing AF-related strokes, MANAGE-AF demonstrates the need for optimization of our therapeutic strategies for the management of cardioembolic stroke risk.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Cardioversión Eléctrica/métodos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Femenino , Estudios de Seguimiento , Grecia/epidemiología , Adhesión a Directriz , Humanos , Masculino , Morbilidad/tendencias , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Tromboembolia/epidemiología , Tromboembolia/etiología , Tromboembolia/prevención & control , Resultado del Tratamiento
17.
Indian Pacing Electrophysiol J ; 13(6): 231-4, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24482566

RESUMEN

In the present case, we describe the abrupt transformation of intra-pulmonary vein activity from rapid firing to dissociated ectopic activity during sinus rhythm, as an easily identifiable, though rare to encounter, sign which documents the achievement of bidirectional block.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA