Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
JACC Clin Electrophysiol ; 9(12): 2558-2570, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37737773

RESUMEN

BACKGROUND: Active esophageal cooling reduces the incidence of endoscopically identified severe esophageal lesions during radiofrequency (RF) catheter ablation of the left atrium for the treatment of atrial fibrillation. A formal analysis of the atrioesophageal fistula (AEF) rate with active esophageal cooling has not previously been performed. OBJECTIVES: The authors aimed to compare AEF rates before and after the adoption of active esophageal cooling. METHODS: This institutional review board (IRB)-approved study was a prospective analysis of retrospective data, designed before collecting and analyzing the real-world data. The number of AEFs occurring in equivalent time frames before and after adoption of cooling using a dedicated esophageal cooling device (ensoETM, Attune Medical) were quantified across 25 prespecified hospital systems. AEF rates were then compared using generalized estimating equations robust to cluster correlation. RESULTS: A total of 14,224 patients received active esophageal cooling during RF ablation across the 25 hospital systems, which included a total of 30 separate hospitals. In the time frames before adoption of active cooling, a total of 10,962 patients received primarily luminal esophageal temperature (LET) monitoring during their RF ablations. In the preadoption cohort, a total of 16 AEFs occurred, for an AEF rate of 0.146%, in line with other published estimates for procedures using LET monitoring. In the postadoption cohort, no AEFs were found in the prespecified sites, yielding an AEF rate of 0% (P < 0.0001). CONCLUSIONS: Adoption of active esophageal cooling during RF ablation of the left atrium for the treatment of atrial fibrillation was associated with a significant reduction in AEF rate.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fístula Esofágica , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Estudios Retrospectivos , Fístula Esofágica/epidemiología , Fístula Esofágica/etiología , Ablación por Catéter/métodos
3.
JACC Clin Electrophysiol ; 9(1): 28-39, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-37166222

RESUMEN

BACKGROUND: Venous ethanol ablation (VEA) can be effective for ventricular arrhythmias from the left ventricular summit (LVS); however, there are concerns about excessive ablation by VEA. OBJECTIVES: The purpose of this study was to delineate and quantify the location, extent, and evolution of ablated tissue after VEA as an intramural ablation technique in the LVS. METHODS: VEA was performed in 59 patients with LVS ventricular arrhythmias. Targeted intramural veins were selected by electrograms from a 2F octapolar catheter or by guide-wire unipolar signals. Median ethanol delivered was 4 mL (IQR: 4-7 mL). Ablated areas were estimated intraprocedurally as increased echogenicity on intracardiac echocardiography (ICE) and incorporated into 3-dimensional maps. In 44 patients, late gadolinium enhancement cardiac magnetic resonance (CMR) imaged VEA scar and its evolution. RESULTS: ICE-demonstrated increased intramural echogenicity (median volume of 2 mL; IQR: 1.7-4.3) at the targeted region of the 3-dimensional maps. Post-ethanol CMR showed intramural scar of 2.5 mL (IQR: 2.1-3.5 mL). Early (within 48 hours after VEA) CMR showed microvascular obstruction (MVO) in 30 of 31 patients. Follow-up CMR after a median of 51 (IQR: 41-170) days showed evolution of MVO to scar. ICE echogenicity and CMR scar volumes correlated with each other and with ethanol volume. Ventricular function and interventricular septum remained intact. CONCLUSIONS: VEA leads to intramural ablation that can be tracked intraprocedurally by ICE and creates regions of MVO that are chronically replaced by myocardial scar. VEA scar volume does not compromise septal integrity or ventricular function.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Tabique Interventricular , Humanos , Cicatriz , Medios de Contraste , Taquicardia Ventricular/cirugía , Ablación por Catéter/métodos , Gadolinio , Arritmias Cardíacas/cirugía
4.
JACC Clin Electrophysiol ; 9(4): 497-507, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36752460

RESUMEN

BACKGROUND: Improved ablation catheter-tissue contact results in more effective ablation lesions. Respiratory motion causes catheter instability, which impacts durable pulmonary vein isolation (PVI). OBJECTIVES: This study sought to evaluate the safety and efficacy of a novel ablation strategy involving prolonged periods of apneic oxygenation during PVI. METHODS: We conducted a multicenter, prospective controlled study of 128 patients (mean age 63 ± 11 years; 37% women) with paroxysmal atrial fibrillation undergoing PVI. Patients underwent PVI under general anesthesia using serial 4-minute runs of apneic oxygenation (apnea group; n = 64) or using standard ventilation settings (control group; n = 64). Procedural data, arterial blood gas samples, catheter position coordinates, and ablation lesion characteristics were collected. RESULTS: Baseline characteristics between the 2 groups were similar. Catheter stability was significantly improved in the apnea group, as reflected by a decreased mean catheter displacement (1.55 ± 0.97 mm vs 2.25 ± 1.13 mm; P < 0.001) and contact force SD (4.9 ± 1.1 g vs 5.2 ± 1.5 g; P = 0.046). The percentage of lesions with a mean catheter displacement >2 mm was significantly lower in the apnea group (22% vs 44%; P < 0.001). Compared with the control group, the total ablation time to achieve PVI was reduced in the apnea group (18.8 ± 6.9 minutes vs 23.4 ± 7.8 minutes; P = 0.001). There were similar rates of first-pass PVI, acute PV reconnections and dormant PV reconnections between the two groups. CONCLUSIONS: A novel strategy of performing complete PVI during apneic oxygenation results in improved catheter stability and decreased ablation times without adverse events. (Radiofrequency Ablation of Atrial Fibrillation Under Apnea; NCT04170894).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Venas Pulmonares/cirugía , Estudios Prospectivos , Apnea/cirugía , Apnea/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
5.
Circulation ; 146(22): 1644-1656, 2022 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-36321460

RESUMEN

BACKGROUND: Ablation of ventricular tachycardia (VT) in the setting of structural heart disease often requires extensive substrate elimination that is not always achievable by endocardial radiofrequency ablation. Epicardial ablation is not always feasible. Case reports suggest that venous ethanol ablation (VEA) through a multiballoon, multivein approach can lead to effective substrate ablation, but large data sets are lacking. METHODS: VEA was performed in 44 consecutive patients with ablation-refractory VT (ischemic, n=21; sarcoid, n=3; Chagas, n=2; idiopathic, n=18). Targeted veins were selected by mapping coronary veins on the epicardial aspect of endocardial scar (identified by bipolar voltage <1.5 mV), using venography and signal recording with a 2F octapolar catheter or by guidewire unipolar signals. Epicardial mapping was performed in 15 patients. Vein segments in the epicardial aspect of VT substrates were treated with double-balloon VEA by blocking flow with 1 balloon while injecting ethanol through the lumen of the second balloon, forcing (and restricting) ethanol between balloons. Multiple balloon deployments and multiple veins were used as needed. In 22 patients, late gadolinium enhancement cardiac magnetic resonance imaged the VEA scar and its evolution. RESULTS: Median ethanol delivered was 8.75 (interquartile range, 4.5-13) mL. Injected veins included interventricular vein (6), diagonal (5), septal (12), lateral (16), posterolateral (7), and middle cardiac vein (8), covering the entire range of left ventricular locations. Multiple veins were targeted in 14 patients. Ablated areas were visualized intraprocedurally as increased echogenicity on intracardiac echocardiography and incorporated into 3-dimensional maps. After VEA, vein and epicardial ablation maps showed elimination of abnormal electrograms of the VT substrate. Intracardiac echocardiography demonstrated increased intramural echogenicity at the targeted region of the 3-dimensional maps. At 1 year of follow-up, median of 314 (interquartile range, 198-453) days of follow-up, VT recurrence occurred in 7 patients, for a success of 84.1%. CONCLUSIONS: Multiballoon, multivein intramural ablation by VEA can provide effective substrate ablation in patients with ablation-refractory VT in the setting of structural heart disease over a broad range of left ventricular locations.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Vasos Coronarios , Cicatriz , Etanol/uso terapéutico , Medios de Contraste , Gadolinio , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/etiología , Ablación por Catéter/efectos adversos
6.
Circ Arrhythm Electrophysiol ; 15(8): e011017, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35917467

RESUMEN

BACKGROUND: Coronary venous ethanol ablation (VEA) can be used as a strategy to treat ventricular arrhythmias arising from the left ventricular summit, but collateral flow and technical challenges cannulating intramural veins in complex venous anatomies can limit its use. Advanced techniques for VEA can capitalize on collateral vessels between target and nontarget sites to improve success. METHODS: Of 55 patients with left ventricular summit ventricular arrhythmia, advanced techniques were used in 15 after initial left ventricular summit intramural vein mapping failed to show suitable targets for single vein, single-balloon VEA. All patients had previous radiofrequency ablation attempts. Techniques included: double-balloon for distal protection to block distal flow and target the proximal portion of a large intramural vein where best signal was proximal (n=6); balloons in 2 different left ventricular summit veins for a cross-fire multivein VEA (n=4); intramural collateral vein-to-vein cannulation to reach of targeted vein via collateral with antegrade ethanol and proximal balloon block (n=2); prolonged ethanol dwell time for vein sclerosis of large intramural vein and subsequent VEA (n=3); and intramural collateral VEA (n=1). RESULTS: Fifteen (8 females) patients (age 60.6±17.6 years) required advanced techniques. Procedure time was 210±49.9 minutes, fluoroscopy time was 25.3±14.1 minutes, and 113±17.9 cc of contrast was utilized. A median of 7 cc of ethanol was delivered (range, 4-15 cc). Intraprocedural radiofrequency ablation was delivered before ethanol in 9 out of 15 patients but failed. Ethanol achieved acute success in all 15 patients. Ethanol was used as the sole treatment in two patients. At a median follow-up of 194 days, one patient experienced recurrence. CONCLUSIONS: Advanced techniques capitalizing on venous anatomy can enable successful VEA and selective targeting of arrhythmogenic sites, by blocking distal flow, utilization of collaterals between nontarget and target veins and multivein VEA. Understanding individual anatomy is critical for VEA success.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Adulto , Anciano , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Electrocardiografía , Etanol , Femenino , Ventrículos Cardíacos , Humanos , Persona de Mediana Edad , Resultado del Tratamiento
8.
JACC Clin Electrophysiol ; 8(1): 15-25, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34454881

RESUMEN

OBJECTIVES: The aim of this study was to assess temporal changes and clinical implications of peridevice leak (PDL) after left atrial appendage closure. BACKGROUND: Endocardial left atrial appendage closure devices are alternatives to long-term oral anticoagulation (OAC) for patients with atrial fibrillation. PDL >5 mm may prohibit discontinuation of OAC. METHODS: Patients included in the study had: 1) successful Watchman device implantation without immediate PDL; 2) new PDL identified at 45 to 90 days using transesophageal echocardiography; 3) eligibility for OAC; and 4) 1 follow-up transesophageal echocardiographic study for PDL surveillance. Relevant clinical and imaging data were collected by chart review. The combined primary outcome included failure to stop OAC after 45 to 90 days, transient ischemic attack or stroke, device-related thrombi, and need for PDL closure. RESULTS: Relevant data were reviewed for 1,039 successful Watchman device implantations. One hundred eight patients (10.5%) met the inclusion criteria. The average PDL at 45 to 90 days was 3.2 ± 1.6 mm. On the basis of a median PDL of 3 mm, patients were separated into ≤3 mm (n = 73) and >3 mm (n = 35) groups. In the ≤3 mm group, PDL regressed significantly (2.2 ± 0.8 mm vs 1.6 ± 1.4 mm; P = 0.002) after 275 ± 125 days. In the >3 mm group, there was no significant change in PDL (4.9 ± 1.4 mm vs 4.0 ± 3.0 mm; P = 0.12) after 208 ± 137 days. The primary outcome occurred more frequently (69% vs 34%; P = 0.002) in the >3 mm group. The incidence of transient ischemic attack or stroke in patients with PDL was significantly higher compared with patients without PDL, irrespective of PDL size. CONCLUSIONS: New PDL detected by transesophageal echocardiography at 45 to 90 days occurred in a significant percentage of patients and was associated with worse clinical outcomes. PDL ≤3 mm tended to regress over time.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Accidente Cerebrovascular , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
11.
Card Electrophysiol Clin ; 13(2): 313-323, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33990270

RESUMEN

Left atrial appendage closure (LAAC) is an increasingly common procedure for patients with nonvalvular atrial fibrillation and contraindications to long-term anticoagulation. Traditionally, LAAC has been performed under transesophageal echocardiography (TEE) guidance. Although most operators have become experienced and comfortable with TEE-guided appendage closure, there has been a growing interest in the use of intracardiac echocardiography (ICE) for LAAC. This article describes the rationale and technique for ICE-guided LAAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos/métodos , Ecocardiografía , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Humanos , Dispositivo Oclusor Septal , Cirugía Asistida por Computador
14.
J Cardiovasc Electrophysiol ; 31(12): 3277-3285, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33058275

RESUMEN

BACKGROUND: The leadless Micra transcatheter-pacing system (Micra-TPS) is implanted via a femoral approach using a 27-French introducer sheath. The Micra Transcutaneous Pacing Study excluded patients with inferior vena cava (IVC) filters. OBJECTIVE: To examine the feasibility and safety of Micra-TPS implantation through an IVC filter. METHODS: This multicenter retrospective study included patients with an IVC filter who underwent a Micra-TPS implantation. Data for clinical and IVC filter characteristics, preprocedure imaging, and procedural interventions were collected. The primary outcome was a successful leadless pacemaker (LP) implantation via a femoral approach in the presence of an IVC filter. Periprocedural and delayed clinical complications were also evaluated. RESULTS: Of the 1528 Micra-TPS implants attempted, 23 patients (1.5%) had IVC filters. The majority (69.6%) of IVC filters were permanent. Six (26.1%) patients underwent preprocedural imaging to assess for filter patency. One patient's filter was retrieved before LP implantation. The primary outcome was achieved in 21 of 22 patients (95.5%) with an existing IVC filter. An occluded IVC precluded LP implantation in one patient. Difficulty advancing the stiff guidewire or the 27-Fr sheath was encountered in five patients. These cases required repositioning of the wire (n = 2), gradual sheath upsizing (n = 2), or balloon dilation of the filter (n = 1). Postprocedure fluoroscopy revealed intact filters in all cases. During a median 6-month follow-up, there were no clinical complications related to the filter or the Micra-TPS. CONCLUSION: This multicenter experience demonstrates the feasibility and safety of Micra-TPS implantation via an IVC filter without acute procedural or delayed clinical complications.


Asunto(s)
Marcapaso Artificial , Filtros de Vena Cava , Remoción de Dispositivos , Fluoroscopía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Filtros de Vena Cava/efectos adversos , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía
15.
JACC Clin Electrophysiol ; 6(11): 1420-1431, 2020 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-33121671

RESUMEN

OBJECTIVES: The aim of this study was to assess the long-term efficacy and outcomes of retrograde venous ethanol ablation in treating ventricular arrhythmias (VAs). BACKGROUND: Retrograde coronary venous ethanol ablation (RCVEA) can be effective for radiofrequency ablation (RFA)-refractory VAs, particularly those arising in the LV summit (LVS). METHODS: Patients with drug and RFA-refractory VAs were considered for RCVEA after RF failure attempts. Intramural coronary veins (tributaries of the great cardiac, anterior interventricular, lateral cardiac, posterolateral, and middle cardiac) were mapped using an angioplasty wire. Ethanol infusion was delivered in veins with appropriate signals. RESULTS: Of 63 patients (age 63 ± 14 years; 60% men) with VAs (71% extrasystole, 29% ventricular tachycardia, 76% LVS origin), RCVEA was performed in 56 patients who had suitable vein branches. These were defined as those amenable to cannulation and with intramural signals that preceded those mapped in the epicardium or endocardium and had better matching pace maps or entrainment responses. Seven patients had no suitable veins and underwent RFA. In 38 of 56 (68%) patients, the VAs were successfully terminated exclusively with ethanol infusion. In 17 of 56 (30%) patients, successful ablation was achieved using ethanol with adjunctive RFA in the vicinity of the infused vein due to acute recurrence or ethanol-induced change in VA morphology. Overall, isolated or adjuvant RCVEA was successful in 55 of 56 (98%) patients. At 1-year follow-up, 77% of patients were free of recurrent arrhythmias. Procedural complications included 2 venous dissections that led to pericardial effusions. CONCLUSIONS: RCVEA offers a significant long-term effective treatment for patients with drug and RF-refractory VAs.


Asunto(s)
Etanol , Taquicardia Ventricular , Arritmias Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardio , Taquicardia Ventricular/tratamiento farmacológico , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 31(10): 2668-2676, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32618396

RESUMEN

BACKGROUND: Idiopathic ventricular arrhythmias (IVAs) from the left ventricular (LV) summit may be successfully ablated from the distal great cardiac vein (dGCV). Using a 12-lead electrocardiogram (ECG) to localize IVAs that can be ablated from the dGCV is valuable for ablation planning. OBJECTIVE: To determine if a "w" wave, a notch in the Q wave in lead I, and other ECG features can identify IVAs that can be successfully ablated from the dGCV. METHODS: We reviewed outflow tract premature ventricular contraction (PVC) ablations performed at two centers between September 2010 and June 2018. Successful PVC ablations, in which the PVCs were mapped from the right ventricular outflow tract, coronary cusps, commissures, endocardial LV, and the coronary venous system including the dGCV were included. ECG characteristics were compared between patients with successful ablations in the dGCV and non-dGCV sites. RESULTS: Of the 120 patients (age 56.8 ± 13.8 years, 45% female) that met the inclusion criteria, the dGCV was the successful ablation site in 18 patients (15%). Multivariate analysis with binary logistic regression showed that a "w" in lead I in combination with an early precordial pattern break and a maximum deflection index (MDI) ≥ 0.5 had sensitivity and specificity for a successful ablation in the dGCV of 94.4% and 96.1%, respectively. CONCLUSION: Combining a "w" wave in lead I with an early precordial pattern break and an MDI ≥ 0.5 is highly sensitive and specific for identifying the dGCV as a successful ablation site for PVCs.


Asunto(s)
Ablación por Catéter , Seno Coronario , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Ablación por Catéter/efectos adversos , Electrocardiografía , Femenino , Ventrículos Cardíacos/cirugía , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
17.
Heart Rhythm ; 17(9): 1545-1553, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32464184

RESUMEN

BACKGROUND: Experience with retrieval of a Watchman left atrial (LA) appendage (LAA) closure device (WD) is limited. An embolized or grossly malpositioned WD warrants retrieval to minimize the risk of thromboembolic complications and vascular occlusion. OBJECTIVE: The purpose of this study was to report approaches for percutaneous retrieval of a WD from multicenter experience. METHODS: Data on successful WD retrievals were obtained from high-volume operators. Data included clinical characteristics; structural characteristics of the LA and LAA; and procedural details of the deployment and retrieval procedure, type of retrieval (immediate: during the same procedure; delayed: during a separate procedure after the successful deployment), equipment used, complications, and postretrieval management. RESULTS: Ten successful percutaneous and 1 surgical retrievals comprised this study. Seven patients had immediate retrieval, while 4 had delayed retrieval. The median duration before delayed retrieval was 45 days (range 1-45 days). The median LAA diameter and size of a successfully deployed WD was 16 mm (range 14-24 mm) and 21 mm (range 21-30 mm), respectively. A WD was retrieved from the LA (n = 1), LAA (n = 2), left ventricle (n = 2), and aorta (n = 6). The reason for retrieval from the LAA was inadequate deployment, resulting in a significant peri-device leak. Retrieval from the LA or LAA was successfully performed using snares (n = 2) and a Raptor grasping device (n = 1). Retrieval from the left ventricle was achieved with a snare (n = 1) and surgery (n = 1). Retrieval from the aorta required snares (n = 5) and retrieval forceps (n = 1). Five patients were successfully reimplanted with a larger size WD. The only complication during percutaneous retrieval was a pseudoaneurysm. CONCLUSION: Retrieval of an embolized or malpositioned WD is feasible, and familiarity with snares and grasping tools can facilitate a successful removal.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Remoción de Dispositivos/métodos , Migración de Cuerpo Extraño/cirugía , Dispositivo Oclusor Septal/efectos adversos , Tromboembolia/cirugía , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Estudios de Seguimiento , Migración de Cuerpo Extraño/complicaciones , Migración de Cuerpo Extraño/diagnóstico , Humanos , Masculino , Tromboembolia/diagnóstico , Tromboembolia/etiología , Resultado del Tratamiento
20.
Pacing Clin Electrophysiol ; 42(4): 470-473, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30430590

RESUMEN

Escape mapping is a novel technique that can be used to locate sites of persistent conduction and achieve exit block during an atrial fibrillation ablation. This method allows for mapping solely with the ablation catheter in the left atrium by annotating to a catheter in the coronary sinus. We illustrate the utility escape mapping during an atrial fibrillation ablation where entrance block is achieved without exit block. We further expand upon this technique by describing the first reported case of escape mapping being used to achieve bidirectional block during an atrial flutter ablation.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Aleteo Atrial/fisiopatología , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Mapeo Epicárdico , Sistema de Conducción Cardíaco/fisiopatología , Anciano , Seno Coronario/fisiopatología , Seno Coronario/cirugía , Ecocardiografía , Electrocardiografía , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...