Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
BMJ Mil Health ; 168(4): 292-298, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34131066

RESUMEN

INTRODUCTION: Chronic low back pain (CLBP) is a leading cause of disability in the UK Military. Pain and psychological comorbidities have been reported to influence the rating of perceived exertion (RPE). Exercise rehabilitation can be monitored using RPE; however, the accuracy of RPE in inpatient CLBP rehabilitation is unknown. METHODS: A prospective cohort correlation study of 40 UK Military inpatients with CLBP was completed. Disability (ODI), kinesiophobia (TSK), anxiety (GAD-7) and depression (PHQ-9) were subjectively reported at the beginning and end of a 3 week intervention. Pain (VAS) and HR were recorded in the first aerobic exercise (AE) session (T1) and the final aerobic exercise session (T2). RPE was reported for each AE session. RESULTS: At T1, a positive correlation was observed between RPE accuracy (-7.2±20.9), and pre-exercise pain (2.7 mm ±1.6 mm) (p>0.001) and ODI (31.0±16.9) (p>0.05), and a negative relationship between RPE accuracy and average HR (135 bpm ±22 bpm) (p>0.001) was observed. At T2, there was no significant correlation between RPE accuracy (-4.4±22.6) and pre-exercise pain (2.8 mm ±1.6 mm) or ODI (34.0±16.5) (p>0.05). The strong negative relationship between RPE accuracy and average HR (137 bpm ±20 bpm) remained at T2. Improved RPE accuracy over the 3-week rehabilitation programme was correlated to the change in average HR (r=-0.314, p<0.05). CONCLUSIONS: Comorbidities may negatively affect RPE accuracy in CLBP, but the magnitude of the influence reduces over intensive rehabilitation.


Asunto(s)
Dolor de la Región Lumbar , Personal Militar , Humanos , Dolor de la Región Lumbar/rehabilitación , Esfuerzo Físico , Estudios Prospectivos , Reino Unido/epidemiología
2.
Scand J Med Sci Sports ; 28(7): 1757-1765, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29630752

RESUMEN

This study examined the cuff to limb interface pressure during blood flow restriction (BFR), and the perceptual and mean arterial pressure responses, in different BFR systems. Eighteen participants attended three experimental sessions in a randomised, crossover, counterbalanced design. Participants underwent inflations at 40% and 80% limb occlusive pressure (LOP) at rest and completed 4 sets of unilateral leg press exercise at 30% of one repetition maximum with BFR at 80% LOP. Different BFR systems were used each session: an automatic rapid-inflation (RI), automatic personalized tourniquet (PT) and manual handheld pump and sphygmomanometer (HS) system. Interface pressure was measured using a universal interface device with pressure sensors. Perceived exertion and pain were measured after each set, mean arterial pressure (MAP) was measured pre-, 1-minute post- and 5-minutes post-exercise. Interface pressure was lower than the set pressure in all BFR systems at rest (P < .05). Interface pressure was, on average, 10 ± 8 and 48 ± 36 mm Hg higher than the set pressure in the RI and HS system (P < .01), with no differences observed in the PT system (P > .05), during exercise. Pain and exertion were greater in sets 3 and 4 in the RI and HS system compared to the PT system (P < .05). MAP was higher in the RI and HS system compared to the PT system at 1-minute and 5-minutes post-exercise (P < .05). BFR systems applying higher pressures amplify mean arterial pressure and perceptual responses. Automatic BFR systems appear to regulate pressure effectively within an acceptable range during BFR exercise.


Asunto(s)
Presión Arterial , Ejercicio Físico , Flujo Sanguíneo Regional , Torniquetes , Adulto , Constricción , Humanos , Masculino , Presión , Esfigmomanometros , Adulto Joven
3.
Clin Pharmacol Ther ; 88(2): 161-3, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20648033

RESUMEN

Since the 1997 landmark article by Dr. Lewis Sheiner in Clinical Pharmacology & Therapeutics, biopharmaceutical development in phases I-IIA has become more targeted toward learning (i.e., establishing proof of concept), then subsequently confirming that regulated standards are met. The purpose and importance of the learning-proof-of-concept phase is subjective but typically uses traditional statistics (which were developed for use in confirming). Two examples from development are presented to illustrate learning in practice. Suggestions for how to improve and embed the learn-confirm concept and how to enhance the contributions of clinical pharmacology and statistics are considered.


Asunto(s)
Bioestadística , Descubrimiento de Drogas/tendencias , Farmacología Clínica/tendencias , Ensayos Clínicos Fase I como Asunto , Ensayos Clínicos Fase II como Asunto , Ensayos Clínicos Fase III como Asunto , Descubrimiento de Drogas/estadística & datos numéricos , Electrocardiografía/efectos de los fármacos , Humanos , Modelos Lineales , Farmacocinética , Farmacología Clínica/estadística & datos numéricos , Proyectos de Investigación , Serotipificación , Vacunas/uso terapéutico
4.
Artículo en Inglés | MEDLINE | ID: mdl-17249495

RESUMEN

There is a significant need for markers that are diagnostic of disease, particularly cancer. For these biomarkers to be useful they would need to be able to detect disease early in its progression with high sensitivity and specificity. Many approaches are being undertaken to attempt to find such biomarkers using the tools of systems biology, i.e., parallel measurement techniques including proteomics (parallel protein measurements). Often the premise behind such an approach was to cast a wide net and then design an assay for specific elements that were found to be diagnostic. One such approach has utilized matrix-assisted laser desorption/ionization-mass spectrometry to interrogate the low-molecular-weight component of serum (the fluid component of blood following clotting), the serum peptidome. This approach has the appealing characteristic of speed of analysis but has a number of shortcomings mostly due to signal:noise and mass resolution in some instruments, making peak analysis difficult. Of course, experimental design and statistical analysis have to be conducted with the system limitations in mind. These points have been addressed by others, but few have focused on a potentially larger issue with serum peptidome analysis - are the signals being measured informing us about the disease state directly or indirectly through measurement of another physiological process such as hemostatic dysregulation? This article will present evidence that points to careful measures of the serum peptidome revealing differences in clotting time in disease states and not direct measures of tumor proteolytic activity on blood proteins.


Asunto(s)
Proteínas Sanguíneas/química , Hemostasis , Péptidos/química , Proteómica/métodos , Coagulación Sanguínea , Cromatografía Liquida , Humanos , Espectrometría de Masas , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Factores de Tiempo
5.
J Bone Joint Surg Br ; 87(5): 684-6, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15855372

RESUMEN

Our aim was to determine the clinical value of MRI and CT arthrography in predicting the presence of loose bodies in the elbow. A series of 26 patients with mechanical symptoms in the elbow had plain radiography, MRI and CT arthrography, followed by routine arthroscopy of the elbow. The location and number of loose bodies determined by MRI and CT arthrography were recorded. Pre-operative plain radiography, MRI and CT arthrography were compared with arthroscopy. Both MRI and CT arthrography had excellent sensitivity (92% to 100%) but low to moderate specificity (15% to 77%) in identifying posteriorly-based loose bodies. Neither MRI nor CT arthrography was consistently sensitive (46% to 91%) or specific (13% to 73%) in predicting the presence or absence of loose bodies anteriorly. The overall sensitivity for the detection of loose bodies in either compartment was 88% to 100% and the specificity 20% to 70%. Pre-operative radiography had a similar sensitivity and specificity of 84% and 71%, respectively. Our results suggest that neither CT arthrography nor MRI is reliable or accurate enough to be any more effective than plain radiography alone in patients presenting with mechanical symptoms in the elbow.


Asunto(s)
Articulación del Codo , Artropatías/diagnóstico , Adolescente , Adulto , Artrografía/métodos , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/patología , Femenino , Humanos , Artropatías/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
6.
J South Orthop Assoc ; 12(2): 66-70, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12882242

RESUMEN

A 14-year-old female with a 1-year history of a painful clavicle mass underwent resection and reconstruction with an intercalated autograft and rigid plate fixation. The histopathology was diagnostic for osteoblastoma. Although a clavicle mass is a common entity following clavicle trauma, less common disorders such as bone tumors need to be considered in the differential diagnosis. Osteoblastoma is an uncommon, benign bone tumor representing 1% of all primary bone tumors. An extensive review of the literature reveals only one reported case of clavicular osteoblastoma.


Asunto(s)
Neoplasias Óseas/diagnóstico , Clavícula , Osteoblastoma/diagnóstico , Adolescente , Neoplasias Óseas/patología , Neoplasias Óseas/cirugía , Clavícula/diagnóstico por imagen , Clavícula/patología , Femenino , Humanos , Osteoblastoma/patología , Osteoblastoma/cirugía , Cintigrafía , Tomografía Computarizada por Rayos X
7.
J Bone Joint Surg Am ; 83(12): 1823-8, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11741061

RESUMEN

BACKGROUND: The lateral ulnar collateral ligament, the entire lateral collateral ligament complex, and the overlying extensor muscles have all been suggested as key stabilizers against posterolateral rotatory instability of the elbow. The purpose of this investigation was to determine whether either an intact radial collateral ligament alone or an intact lateral ulnar collateral ligament alone is sufficient to prevent posterolateral rotatory instability when the annular ligament is intact. METHODS: Sequential sectioning of the radial collateral and lateral ulnar collateral ligaments was performed in twelve fresh-frozen cadaveric upper extremities. At each stage of the sectioning protocol, a pivot shift test was performed with the arm in a vertical position. Passive elbow flexion was performed with the forearm maintained in either pronation or supination and the arm in the varus and valgus gravity-loaded orientations. An electromagnetic tracking device was used to quantify the internal-external rotation and varus-valgus angulation of the ulna with respect to the humerus. RESULTS: Compared with the intact elbow, no differences in the magnitude of internal-external rotation or maximum varus-valgus laxity of the ulna were detected with only the radial collateral or lateral ulnar collateral ligament intact (p > 0.05). However, once the entire lateral collateral ligament was transected, significant increases in internal-external rotation (p = 0.0007) and maximum varus-valgus laxity (p < 0.0001) were measured. None of the pivot shift tests had a clinically positive result until the entire lateral collateral ligament was sectioned. CONCLUSIONS: This study suggests that, when the annular ligament is intact, either the radial collateral ligament or the lateral ulnar collateral ligament can be transected without inducing posterolateral rotatory instability of the elbow.


Asunto(s)
Ligamentos Colaterales , Articulación del Codo , Inestabilidad de la Articulación/patología , Radio (Anatomía) , Cúbito , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Humanos , Persona de Mediana Edad
8.
J Orthop Trauma ; 15(8): 542-8, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11733669

RESUMEN

OBJECTIVES: To evaluate the functional outcome of plate fixation for displaced olecranon fractures, both simple and comminuted. DESIGN: Retrospective patient, chart, and radiographic review. SETTING: Academic teaching hospital. PATIENTS: Twenty-five patients who underwent plate fixation of displaced olecranon fractures by two surgeons were independently reviewed at an average follow-up of thirty-four months (range, 15-69 months). MAIN OUTCOME MEASUREMENTS: Physical capability was assessed by measuring range of motion and isometric elbow strength. Patient-rated outcomes were evaluated using the SF-36, DASH, Mayo Elbow Performance Index (MEPI), and visual analogue scales for patient satisfaction and pain. Radiographs were evaluated preoperatively, postoperatively, and at the time of final review. RESULTS: The average patient age was fifty-four years (range, 14-81 years). The Mayo classification of fractures was fourteen Type II and eleven Type III. An adequate reduction was maintained in all elbows until union. Physical capability measures indicated nonsignificant side-to-side differences in motion or strength, except for supination motion, which was reduced in the injured arm (p = 0.003). The MEPI-rated outcome was twenty-two excellent or good. Patient satisfaction was high (9.7/10), with a low pain rating (1/10). The mean DASH score was consistent with almost normal upper extremity function. The SF-36 showed no difference in physical health as compared with the average American population. Twenty percent of patients required plate removal because of prominence of the internal fixation. The outcome was not influenced by fracture pattern. CONCLUSION: Plate fixation is an effective treatment option for displaced olecranon fractures with a good functional outcome and a low incidence of complications.


Asunto(s)
Lesiones de Codo , Fijación Interna de Fracturas/instrumentación , Fracturas del Cúbito/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas , Articulación del Codo/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas/métodos , Curación de Fractura/fisiología , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Persona de Mediana Edad , Radiografía , Rango del Movimiento Articular , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas del Cúbito/diagnóstico por imagen
10.
Proteomics ; 1(1): 108-17, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11680890

RESUMEN

With an emphasis on obtaining a multitude of high quality tandem mass spectrometry spectra for protein identification, instrumental parameters are described for the liquid chromatography-tandem mass spectrometry analysis of trypsin digested unfractionated urine using a hybrid quadrupole-time-of-flight (Q-TOF) mass spectrometer. Precursor acquisition rates of up to 20 distinct precursors/minute in a single analysis were obtained through the use of parallel precursor selection (four precursors/survey period) and variable collision induced dissociation integration time (1 to 6 periods summed). Maximal exploitation of the gas phase fractionated ions was obtained through the use of narrow survey scans and iterative data-dependent analyses incorporating dynamic exclusion. The impact on data fidelity as a product of data-dependent selection of precursor ions from a dynamically excluded field is discussed with regards to sample complexity, precursor selection rates, survey scan range and facile chemical modifications. Operational and post-analysis strategies are presented to restore data confidence and reconcile the greatest number of matched spectra.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Proteoma/aislamiento & purificación , Secuencia de Aminoácidos , Humanos , Datos de Secuencia Molecular , Fragmentos de Péptidos/genética , Fragmentos de Péptidos/aislamiento & purificación , Proteoma/genética , Orina/química
11.
Proteomics ; 1(1): 93-107, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11680902

RESUMEN

The proteome of normal male urine from a commercial pooled source has been examined using direct liquid chromatography-tandem mass spectrometry (LC-MS/MS). The entire urinary protein mixture was denatured, reduced and enzymatically digested prior to LC-MS/MS analysis using a hybrid-quadrupole time-of-flight mass spectrometer (Q-TOF) to perform data-dependent ion selection and fragmentation. To fragment as many peptides as possible, the mixture was analyzed four separate times, with the mass spectrometer selecting ions for fragmentation from a subset of the entire mass range for each run. This approach requires only an autosampler on the HPLC for automation (i.e, unattended operation). Across these four analyses, 1.450 peptide MS/MS spectra were matched to 751 sequences to identify 124 gene products (proteins and translations of expressed sequence tags). Interestingly, the experimental time for these analyses was less than that required to run a single two-dimensional gel.


Asunto(s)
Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Proteoma/aislamiento & purificación , Secuencia de Aminoácidos , Western Blotting , Electroforesis en Gel Bidimensional , Genoma Humano , Humanos , Masculino , Datos de Secuencia Molecular , Fragmentos de Péptidos/genética , Fragmentos de Péptidos/aislamiento & purificación , Proteoma/genética , Tripsina , Orina/química
12.
Proteomics ; 1(1): 79-92, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11680901

RESUMEN

In an attempt to identify peptides that may be involved in the obese phenotype observed in CpEfat/CpEfat mice (deficient in Carboxypeptidase E, CpE) samples from fourteen neuroendocrine tissues in wild-type and CpEfat/CpEfat mice were obtained. Peptides were purified from these tissues and potential CpE substrate peptides were enriched using an anhydrotrypsin column that captures peptides with basic C-termini. Bound peptides were subjected to tryptic digestion and followed by liquid chromatography-mass spectrometry analysis. The relative levels of CpEfat/CpEfat versus wild-type peptides were determined by comparison of the ion intensities. Peptide ions elevated in the CpEfat/CpEfat samples were identified by targeted liquid chromatography-tandem mass spectrometry. From those ions, 27 peptides derived from known neuropeptides (including CpE substrates) were identified, together with another 25 peptides from proteins not known to be components of the neuropeptide processing pathway. The known CpE substrates identified included the recently discovered proSAAS, granin-like neuroendocrine peptide precursor that inhibits prohormone processing. The approach demonstrated the feasibility of using an affinity-based method for identifying differences in specific classes of peptides between normal and mutant mice.


Asunto(s)
Carboxipeptidasas/genética , Carboxipeptidasas/metabolismo , Obesidad/enzimología , Obesidad/genética , Secuencia de Aminoácidos , Animales , Carboxipeptidasa H , Cromatografía Liquida , Espectrometría de Masas , Ratones , Ratones Mutantes , Datos de Secuencia Molecular , Neuropéptidos/genética , Neuropéptidos/metabolismo , Sistemas Neurosecretores/metabolismo , Obesidad/metabolismo , Precursores de Proteínas/genética , Precursores de Proteínas/metabolismo , Procesamiento Proteico-Postraduccional , Proteoma , Especificidad por Sustrato , Distribución Tisular
13.
J Bone Joint Surg Am ; 83(8): 1201-11, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11507129

RESUMEN

BACKGROUND: Treatment of unreconstructible comminuted fractures of the radial head remains controversial. There is limited information on the outcome of management of these injuries with arthroplasty with a metal radial head implant. METHODS: The functional outcomes of arthroplasties with a metal radial head implant for the treatment of twenty-five displaced, unreconstructible fractures of the radial head in twenty-four consecutive patients (mean age, fifty-four years) were evaluated at a mean of thirty-nine months (minimum, two years). There were ten Mason type-III and fifteen Mason-Johnston type-IV injuries. Two of these injuries were isolated, and twenty-three were associated with other elbow fractures and/or ligamentous injuries. RESULTS: At the time of follow-up, Short Form-36 (SF-36) summary scores suggested that overall health-related quality of life was within the normal range (physical component = 47 +/- 10, and mental component = 49 +/- 13). Other outcome scales indicated mild disability of the upper extremity (Disabilities of the Arm, Shoulder and Hand score = 17 +/- 19), wrist (Patient-Rated Wrist Evaluation score = 17 +/- 21 and Wrist Outcome Score = 60 +/- 10), and elbow (Mayo Elbow Performance Index = 80 +/- 16). According to the Mayo Elbow Performance Index, three results were graded as poor; five, as fair; and seventeen, as good or excellent. The poor and fair outcomes were associated with concomitant injury in two patients, a history of a psychiatric disorder in three, comorbidity in two, a Workers' Compensation claim in two, and litigation in one. Subjective patient satisfaction averaged 9.2 on a scale of 1 to 10. Elbow flexion of the injured extremity averaged 140 degrees +/- 9 degrees; extension, -8 degrees +/- 7 degrees; pronation, 78 degrees +/- 9 degrees; and supination, 68 degrees +/- 10 degrees. A significant loss of elbow flexion and extension and of forearm supination occurred in the affected extremity, which also had significantly less strength of isometric forearm pronation (17%) and supination (18%) as well as significantly less grip strength (p < 0.05). Asymptomatic bone lucencies surrounded the stem of the implant in seventeen of the twenty-five elbows. Valgus stability was restored, and proximal radial migration did not occur. Complications, all of which resolved, included one complex regional pain syndrome, one ulnar neuropathy, one posterior interosseous nerve palsy, one episode of elbow stiffness, and one wound infection. CONCLUSIONS: Patients treated with a metal radial head implant for a severely comminuted radial head fracture will have mild-to-moderate impairment of the physical capability of the elbow and wrist. At the time of short-term follow-up, arthroplasty with a metal radial head implant was found to have been a safe and effective treatment option for patients with an unreconstructible radial head fracture; however, long-term follow-up is still needed.


Asunto(s)
Artroplastia , Lesiones de Codo , Fracturas Conminutas/cirugía , Prótesis e Implantes , Fracturas del Radio/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Codo/diagnóstico por imagen , Codo/cirugía , Femenino , Fracturas Conminutas/diagnóstico por imagen , Humanos , Masculino , Metales , Persona de Mediana Edad , Diseño de Prótesis , Radiografía , Fracturas del Radio/diagnóstico por imagen , Estudios Retrospectivos
14.
J Clin Pharmacol ; 41(8): 811-22, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11504268

RESUMEN

The Food and Drug Administration (FDA) has proposed replacing the 1992 average bioequivalence (ABE) with population and individual bioequivalence (PBE & IBE), as outlined in the preliminary draft guidance of December 1997, which was subsequently replaced by the draft guidances of August 1999 and resolved in the final guidance of October 2000. This has led to considerable public debate among regulatory, academic, and industry experts at numerous conferences (e.g., FDA/AAPS March 1998, FDA/AAPS August-September 1999, FDA Pharmaceutical Sciences Advisory Committee September 1999) and in the literature. The final guidance calls for ABE to remain as the primary criterion by which new formulations may be judged ready for access to the marketplace. In addition, the FDA recommends the use of replicate study designs for the specific drug classes of controlled-release formulations and highly variable drugs. The final guidance also alludes to the possibility of a sponsor requesting alternative criteria such as PBE and IBE following consultation with the FDA. This procedure amounts to a data collection period during which data suitable to evaluate the operating characteristics of PBE and IBE would be generated, analyzed, and discussed among interested parties. A comprehensive review of currently available databases is useful in determining the ultimate value of this data collection period. This report provides an update to the previous publication by the authors. In all, 28 data sets from 20 replicate cross-over bioequivalence studies have been analyzed (n = 12-96) using the statistical methodology in the most recent FDA draft guidance. The results are presented below. ABE Pass: ABE Fail: Total: AUC/Cmax AUC/Cmax AUC/Cmax AUC/Cmax Pass PBE & IBE 20/14 1/3 21/17 Pass IBE only 1/0 0/0 1/0 Fail PBE and IBE 0/2 0/1 0/3 Fail IBE only 2/3 4/5 6/8 Total 23/19 5/9 28/28 Review of the database reveals many interesting features, most notably the lack of consistent results within a given data set across all three criteria. The sensitivity of subject-by-formulation interaction to sample size and inherent variability of the compounds is further explored through simulation studies. It is concluded that additional simulation assessments must be considered when evaluating the value of a data collection period for PBE and IBE assessment. It will be shown that definitive conclusions regarding some of the operating characteristics of PBE and IBE can be achieved through a combination of data-driven hypotheses followed by simulation studies to further evaluate the hypotheses. Some recommendations for further data collection will be made.


Asunto(s)
Equivalencia Terapéutica , Recolección de Datos , Humanos , Estados Unidos , United States Food and Drug Administration
15.
Clin Orthop Relat Res ; (388): 118-24, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11451110

RESUMEN

The influence of muscle activity and forearm position on the stability of the lateral collateral ligament deficient elbow was investigated in vitro, using a custom testing apparatus to simulate active and passive elbow flexion. Rotation of the ulna relative to the humerus was measured before and after sectioning of the joint capsule, and the radial and lateral ulnar collateral ligaments from the lateral epicondyle. Gross instability was present after lateral collateral ligament transection during passive elbow flexion with the arm in the varus orientation. In the vertical orientation during passive elbow flexion, stability of the lateral collateral ligament deficient elbow was similar to the intact elbow with the forearm held in pronation, but not similar to the intact elbow when maintained in supination. This instability with the forearm supinated was reduced significantly when simulated active flexion was done. The stabilizing effect of muscle activity suggests physical therapy of the lateral collateral ligament deficient elbow should focus on active rather than passive mobilization, while avoiding shoulder abduction to minimize varus elbow stress. Passive mobilization should be done with the forearm maintained in pronation.


Asunto(s)
Ligamentos Colaterales/fisiología , Articulación del Codo/fisiología , Músculo Esquelético/fisiología , Pronación , Electromiografía , Humanos
16.
J Clin Pharmacol ; 41(6): 683-90, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11402638

RESUMEN

The effect of rosiglitazone (Avandia [BRL 49653C]) on the pharmacokinetics of ethinylestradiol and norethindrone was evaluated after repeat dosing of rosiglitazone with an oral contraceptive (OC; Ortho-Novum 1/35 containing norethindrone 1 mg and ethinylestradiol 0.035 mg) in a randomized, double-blind, placebo-controlled crossover study. Thirty-four healthy female volunteers received oral rosiglitazone (RSG) 8 mg + OC or matched placebo (P) + OC daily on days 1 to 14 of a 28-day OC dosing cycle; the alternate regimen was administered during a second cycle. Ethinylestradiol and norethindrone pharmacokinetics were determined from plasma concentrations on day 14. Lack of pharmacokinetic effect was prospectively defined as 90% CI for the point estimate (PE) of the ratio (RSG + OC):(P + OC) contained within a 20% equivalence range for both ethinylestradiol and norethindrone (analyzed by ANOVA). For RSG + OC and P + OC, respectively, mean ethinylestradiol AUC(0-24) was 1126 and 1208 pg.h/mL (PE: 0.92; 90% CI: 0.88-0.97), and mean norethindrone AUC(0-24) was 178 and 171 ng.h/mL (PE: 1.04; 90% CI: 1.00-1.07). Thus, rosiglitazone had no significant effects on the pharmacokinetics of ethinylestradiol or norethindrone. Coadministration of rosiglitazone with OCs does not induce metabolism of these synthetic sex steroids and is not expected to impair the efficacy of OCs or hormone replacement therapy.


Asunto(s)
Hidrocarburo de Aril Hidroxilasas , Anticonceptivos Orales Combinados/farmacocinética , Etinilestradiol/farmacocinética , Hipoglucemiantes/farmacología , Noretindrona/farmacocinética , Tiazoles/farmacología , Tiazolidinedionas , Adulto , Anticonceptivos Orales Combinados/farmacología , Anticonceptivos Sintéticos Orales/farmacocinética , Estudios Cruzados , Citocromo P-450 CYP3A , Sistema Enzimático del Citocromo P-450/metabolismo , Método Doble Ciego , Interacciones Farmacológicas , Congéneres del Estradiol/farmacocinética , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Oxidorreductasas N-Desmetilantes/metabolismo , Placebos , Rosiglitazona , Tiazoles/administración & dosificación
17.
J Hand Surg Am ; 26(2): 218-27, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11279567

RESUMEN

The in vitro stability of an Ilizarov hybrid external fixator was compared with that of a dorsal 3.5-mm AO T-plate in 8 unpaired, fresh-frozen upper extremities. A specially designed testing device that used computer-controlled pneumatic actuators was used to simulate active finger, wrist, and forearm motions by applying loads to relevant tendons. A comminuted extra-articular distal radius fracture was modelled using a dorsally based wedge osteotomy. Fracture stability was assessed using an electromagnetic tracking device to measure motion across the fracture site after randomized application of the plate and the hybrid fixator. During simulated finger and wrist motions with the forearm pronated or supinated, motion of the distal fragment with the hybrid fixator applied was comparable to or statistically less than with the AO plate applied. During simulated forearm rotation, the stability provided by the 2 fixation types was similar, although the plate allowed statistically less radial-ulnar deviation of the fragment. In this model of a 2-part extra-articular distal radius fracture, the clinically meaningful stability of the Ilizarov hybrid external fixator was comparable to that of the dorsal AO plate.


Asunto(s)
Fijación Interna de Fracturas/métodos , Técnica de Ilizarov , Fracturas del Radio/fisiopatología , Fracturas del Radio/cirugía , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Fenómenos Electromagnéticos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular
18.
Neurology ; 56(10): 1403-4, 2001 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-11376199

RESUMEN

Bilateral locked posterior fracture dislocation of the shoulders is one of the least common injuries of the shoulder, and this injury has been suggested to be pathognomonic of seizures when diagnosed in the absence of trauma. The authors present a case of idiopathic bilateral locked posterior fracture dislocations of the shoulder, along with a review of the medical literature. The authors also present the "triple E syndrome," describing the possible etiologies of this injury: epilepsy (or any convulsive seizure), electrocution, or extreme trauma.


Asunto(s)
Convulsiones/complicaciones , Luxación del Hombro/fisiopatología , Fracturas del Hombro/etiología , Adulto , Traumatismos por Electricidad/complicaciones , Traumatismos por Electricidad/patología , Traumatismos por Electricidad/fisiopatología , Lateralidad Funcional/fisiología , Humanos , Masculino , Convulsiones/fisiopatología , Luxación del Hombro/etiología , Luxación del Hombro/patología , Fracturas del Hombro/patología , Fracturas del Hombro/fisiopatología , Heridas y Lesiones/complicaciones , Heridas y Lesiones/patología , Heridas y Lesiones/fisiopatología
19.
J Hand Surg Am ; 26(2): 210-7, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11279566

RESUMEN

The advantages of Ilizarov external fixation, allowing early motion of adjacent joints during fixation of periarticular fractures, have not yet been applied to distal radius fractures. A magnetic resonance imaging study of 10 normal volunteers evaluated the safety of passing percutaneous transfixion pins across the distal radius in 3 forearm positions. Even in the optimal forearm position, the safe zones between the transfixion pin, vessel, nerve, or tendon was small, suggesting that open placement would be required. A cadaver study in 8 specimens demonstrated that the pins could be placed with an open technique using an aiming device and that the pins could be placed without limiting forearm rotation. The proximity of vital structures to transfixion pins dictates open placement to safely apply Ilizarov fixation to distal radius fractures.


Asunto(s)
Clavos Ortopédicos , Técnica de Ilizarov/instrumentación , Fracturas del Radio/cirugía , Adulto , Análisis de Varianza , Cadáver , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Articulación de la Muñeca/anatomía & histología
20.
J Chromatogr B Biomed Sci Appl ; 752(2): 281-91, 2001 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-11270867

RESUMEN

A simple multidimensional liquid chromatography system utilizing an isocratic pump and a HPLC system is described for the comprehensive proteomic analysis of complex peptide digest mixtures by coupled LC-LC-MS-MS techniques. A binary ion-exchange separation was achieved through the use of a strong cation-exchange column followed by a reversed-phase column for data-dependent LC-MS-MS analysis of the unbound analytes, and following salt elution (and concomitant column reequilibration), the bound analytes. Off-line validation of the platform showed near quantitative recovery of fractionated peptides and essentially complete ion-exchange partitioning. In comparative analyses of a highly complex peptide digest mixture a >40% increase in the number of peptide and protein identifications was achieved using this multidimensional platform compared to an unfractionated control.


Asunto(s)
Cromatografía por Intercambio Iónico/métodos , Espectrometría de Masas/métodos , Proteoma/química , Secuencia de Aminoácidos , Automatización , Datos de Secuencia Molecular , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA