Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 51
1.
Am J Trop Med Hyg ; 109(6): 1329-1332, 2023 12 06.
Article En | MEDLINE | ID: mdl-37972332

Jamestown Canyon virus (JCV) (Peribunyavirdae; Orthobunyavirus) is a mosquito-borne pathogen endemic to North America. The genome is composed of three segmented negative-sense RNA fragments designated as small, medium, and large. Jamestown Canyon virus is an emerging threat to public health, and infection in humans can cause severe neurological diseases, including encephalitis and meningitis. We report JCV mosquito surveillance data from 2001 to 2022 in New York state. Jamestown Canyon virus was detected in 12 mosquito species, with the greatest prevalence in Aedes canadensis and Anopheles punctipennis. Detection fluctuated annually, with the highest levels recorded in 2020. Overall, JCV infection rates were significantly greater from 2012 to 2022 compared with 2001 to 2011. Full-genome sequencing and phylogenetic analysis were also performed with representative JCV isolates collected from 2003 to 2022. These data demonstrated the circulation of numerous genetic variants, broad geographic separation, and the first identification of lineage B JCV in New York state in 2022.


Anopheles , Encephalitis Virus, California , Encephalitis, California , Animals , Humans , Encephalitis Virus, California/genetics , New York/epidemiology , Phylogeny
2.
iScience ; 26(8): 107468, 2023 Aug 18.
Article En | MEDLINE | ID: mdl-37593454

West Nile virus (WNV), the most prevalent arthropod-borne virus (arbovirus) in the United States, is maintained in a cycle between Culex spp. mosquitoes and birds. Arboviruses exist within hosts and vectors as a diverse set of closely related genotypes. In theory, this genetic diversity can facilitate adaptation to distinct environments during host cycling, yet host-specific fitness of minority genotypes has not been assessed. Utilizing WNV deep-sequencing data, we previously identified a naturally occurring, mosquito-biased substitution, NS3 P319L. Using both cell culture and experimental infection in natural hosts, we demonstrated that this substitution confers attenuation in vertebrate hosts and increased transmissibility by mosquitoes. Biochemical assays demonstrated temperature-sensitive ATPase activity consistent with host-specific phenotypes. Together these data confirm the maintenance of host-specific minority variants in arbovirus mutant swarms, suggest a unique role for NS3 in viral fitness, and demonstrate that intrahost sequence data can inform mechanisms of host-specific adaptation.

3.
J Pharm Sci ; 112(3): 779-789, 2023 03.
Article En | MEDLINE | ID: mdl-36252652

Polysorbate-80 (PS-80) is a common surfactant used in biologics formulations. However, the tendency of oxidation to PS-80 when exposed to stainless steel surfaces brings various challenges during manufacturing processes, such as inconsistent shelf-life of PS-80 solutions, which can further impact the biologics and vaccines production. In this work, the root causes of PS-80 oxidation when in contact with stainless steel conditions were thoroughly investigated through the use of various complementary analytical techniques including U/HPLC-CAD, LC-MS, ICP-MS, peroxide assay, and EPR spectroscopy. The analytical tool kit used in this work successfully revealed a PS-80 degradation mechanism from the perspective of PS-80 content, PS-80 profile, iron content, peroxide production, and radical species. The combined datasets reveal that PS-80 oxidative degradation occurs in the presence of histidine and iron in addition to being combined with the hydroperoxides in PS-80 material. The oxidative pathway and potential degradants were identified by LC-MS. The PS-80 profile based on the U/HPLC-CAD assay provided an effective way to identify early-signs of PS-80 degradation. The results from a peroxide assay observed increased hydroperoxide along with PS-80 degradation. EPR spectra confirmed the presence of histidine-related radicals during PS-80 oxidation identifying how histidine is involved in the oxidation. All assays and findings introduced in this work will provide insight into how PS-80 oxidative degradation can be avoided, controlled, or detected. It will also provide valuable evaluations on techniques that can be used to identify PS-80 degradation related events that occur during the manufacturing process.


Polysorbates , Stainless Steel , Polysorbates/chemistry , Stainless Steel/chemistry , Histidine/chemistry , Oxidation-Reduction , Iron , Peroxides , Hydrogen Peroxide , Oxidative Stress
4.
J Assoc Med Microbiol Infect Dis Can ; 7(3): 186-195, 2022 Sep.
Article En | MEDLINE | ID: mdl-36337598

BACKGROUND: Serological assays designed to detect SARS-CoV-2 antibodies are being used in serological surveys and other specialized applications. As a result, and to ensure that the outcomes of serological testing meet high quality standards, evaluations are required to assess the performance of these assays and the proficiency of laboratories performing them. METHODS: A panel of 60 plasma/serum samples from blood donors who had reverse transcriptase-polymerase chain reaction (RT-PCR) confirmed SARS-CoV-2 infections and 21 SARS-CoV-2 negative samples were secured and distributed to interested laboratories within Canada (n = 30) and the United States (n = 1). Participating laboratories were asked to provide details on the diagnostic assays used, the platforms the assays were performed on, and the results obtained for each panel sample. Laboratories were blinded with respect to the expected outcomes. RESULTS: The performance of the different assays evaluated was excellent, with the high-throughput platforms of Roche, Ortho, and Siemens demonstrating 100% sensitivity. Most other high-throughput platforms had sensitivities of >93%, with the exception of the IgG assay using the Abbott ARCHITECT which had an average sensitivity of only 87%. The majority of the high-throughput platforms also demonstrated very good specificities (>97%). CONCLUSION: This proficiency study demonstrates that most of the SARS-CoV-2 serological assays utilized by provincial public health or hospital laboratories in Canada have acceptable sensitivity and excellent specificity.


HISTORIQUE: Les dosages sérologiques conçus pour dépister les anticorps anti-SRAS-CoV-2 sont utilisés dans les études sérologiques et d'autres applications spécialisées. Par conséquent, et pour s'assurer que leurs résultats respectent des normes de qualité, il faut procéder à des évaluations de leur performance et de la compétence des laboratoires à les effectuer. MÉTHODOLOGIE: Les chercheurs ont obtenu une batterie de 60 prélèvements de plasma et de sérum chez des donneurs dont l'amplification en chaîne par polymérase après transcription inverse (RT-PCR) avait confirmé des infections par le SRAS-CoV-2 et de 21 prélèvements dont les résultats étaient négatifs au SRAS-CoV-2 et les ont distribués aux laboratoires intéressés du Canada (n = 30) et des États-Unis (n = 1). Ils ont invité les laboratoires participants à fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages étaient exécutés et les résultats obtenus pour chaque échantillon. Les chercheurs ont demandé aux laboratoires participants de fournir de l'information détaillée sur les dosages diagnostiques utilisés, les plateformes sur lesquelles les dosages ont été effectués, et les résultats obtenus à l'égard de chaque échantillon. Les laboratoires ont mené les études à l'insu des résultats escomptés. RÉSULTATS: Les divers dosages avaient une excellente exécution, les plateformes à haut débit de Roche, d'Ortho et de Siemens démontrant une sensibilité de 100 %. La plupart des autres plateformes à haut débit avaient des sensibilités de plus de 93 %, à l'exception des dosages des IgG faisant appel à l'analyseur ARCHITECT d'Abbott, dont la sensibilité moyenne était de seulement 87 %. La majorité des plateformes à haut débit avaient également une très bonne spécificité (plus de 97 %). CONCLUSION: La présente étude de compétence démontre que la plupart des dosages sérologiques du SRAS-CoV-2 évalués dans des laboratoires sanitaires provinciaux ou les laboratoires hospitaliers du Canada possèdent une sensibilité acceptable et une excellente spécificité.

5.
Nutrients ; 14(20)2022 Oct 13.
Article En | MEDLINE | ID: mdl-36296952

Fruits and vegetables containing phenylalanine ≤ 75 mg/100 g (except potatoes) have little impact on blood phenylalanine in phenylketonuria (PKU). In a randomized, controlled, crossover intervention trial, we examined the effect of increasing phenylalanine intake from fruits and vegetables, containing phenylalanine 76−100 mg /100 g, compared with milk protein sources on blood phenylalanine control. This was a five-phase study (4 weeks each phase). In Phase A, patients remained on their usual diet and then were randomly allocated to start Phase B and C (an additional phenylalanine intake of 50 mg/day, then 100 mg from fruits and vegetables containing phenylalanine 76−100 mg/100 g) or Phase D and E (an additional phenylalanine intake of 50 mg/day then 100 mg/day from milk sources). There was a 7-day washout with the usual phenylalanine-restricted diet between Phase B/C and D/E. Blood phenylalanine was measured on the last 3 days of each week. If four out of six consecutive blood phenylalanine levels were >360 µmol/L in one arm, this intervention was stopped. Sixteen patients (median age 10.5 y; range 6−12 y) were recruited. At baseline, a median of 6 g/day (range: 3−25) natural protein and 60 g/day (range: 60−80) protein equivalent from protein substitute were prescribed. Median phenylalanine levels were: Phase A­240 µmol/L; Phase B­260 µmol/L; Phase C­280 µmol/L; Phase D­270 µmol/L and Phase E­280 µmol/L. All patients tolerated an extra 50 mg/day of phenylalanine from fruit and vegetables, containing phenylalanine 76−100 mg/100 g, but only 11/16 (69%) tolerated an additional 100 mg /day. With milk protein, only 8/16 (50%) tolerated an extra 50 mg/day and only 5/16 (31%) tolerated an additional 100 mg/day of phenylalanine. Tolerance was defined as maintaining consistent blood phenylalanine levels < 360 µmol/L throughout each study arm. There was a trend that vegetable protein had less impact on blood phenylalanine control than milk protein, but overall, the differences were not statistically significant (p = 0.152). This evidence supports the PKU European Guidelines cutoff that fruit and vegetables containing 76−100 mg phenylalanine/100 g should be calculated as part of the phenylalanine exchange system. Tolerance of the 'free use' of these fruits and vegetables depends on inter-patient variability but cannot be recommended for all patients with PKU.


Fruit , Phenylketonurias , Child , Humans , Plant Proteins, Dietary , Milk Proteins , Vegetables , Phenylalanine
6.
J Chromatogr A ; 1682: 463453, 2022 Oct 25.
Article En | MEDLINE | ID: mdl-36162253

The purpose of this review is to highlight noteworthy advancements in the field of capillary gel electrophoresis for the separation and analysis of proteins from the period of 2015-2021. This review will provide an overview of the historical perspective and principles of the technique, introduce the challenges and limitations commonly faced, and highlight the advancements made to overcome these issues and broaden our knowledge of the method. Finally, applications of capillary gel electrophoresis and future directions for the technique will be presented.


Electrophoresis, Capillary , Proteins , Electrophoresis, Capillary/methods
7.
Front Immunol ; 13: 995412, 2022.
Article En | MEDLINE | ID: mdl-36172366

Anti-COVID antibody therapeutics have been developed but not widely used due to their high cost and escape of neutralization from the emerging variants. Here, we describe the development of VHH-IgA1.1, a nanobody IgA fusion molecule as an inhalable, affordable and less invasive prophylactic and therapeutic treatment against SARS-CoV-2 Omicron variants. VHH-IgA1.1 recognizes a conserved epitope of SARS-CoV-2 spike protein Receptor Binding Domain (RBD) and potently neutralizes major global SARS-CoV-2 variants of concern (VOC) including the Omicron variant and its sub lineages BA.1.1, BA.2 and BA.2.12.1. VHH-IgA1.1 is also much more potent against Omicron variants as compared to an IgG Fc fusion construct, demonstrating the importance of IgA mediated mucosal protection for Omicron infection. Intranasal administration of VHH-IgA1.1 prior to or after challenge conferred significant protection from severe respiratory disease in K18-ACE2 transgenic mice infected with SARS-CoV-2 VOC. More importantly, for cost-effective production, VHH-IgA1.1 produced in Pichia pastoris had comparable potency to mammalian produced antibodies. Our study demonstrates that intranasal administration of affordably produced VHH-IgA fusion protein provides effective mucosal immunity against infection of SARS-CoV-2 including emerging variants.


COVID-19 , Immunoglobulin A , SARS-CoV-2 , Single-Domain Antibodies , Angiotensin-Converting Enzyme 2 , Animals , Antibodies, Viral/pharmacology , Epitopes/chemistry , Humans , Immunoglobulin A/pharmacology , Immunoglobulin G , Mice , Single-Domain Antibodies/pharmacology , Spike Glycoprotein, Coronavirus
8.
mSphere ; 7(4): e0019322, 2022 08 31.
Article En | MEDLINE | ID: mdl-35703544

In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies" (https://www.cancer.gov/research/key-initiatives/covid-19/coronavirus-research-initiatives/serological-sciences-network). SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology standard reference material and first WHO international standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. SeroNet institutions reported development of a total of 27 enzyme-linked immunosorbent assay (ELISA) methods, 13 multiplex assays, and 9 neutralization assays and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. In conclusion, SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons. IMPORTANCE SeroNet institutions have developed or implemented 61 diverse COVID-19 serological assays and are collaboratively working to harmonize these assays using reference materials to establish standardized reporting units. This will facilitate clinical interpretation of serology results and cross-comparison of research data.


COVID-19 , Antibodies, Viral , COVID-19/diagnosis , COVID-19 Testing , Humans , SARS-CoV-2 , Serologic Tests/methods
10.
Viruses ; 14(4)2022 03 29.
Article En | MEDLINE | ID: mdl-35458446

Surface plasmon resonance and biolayer interferometry are two common real-time and label-free assays that quantify binding events by providing kinetic parameters. There is increased interest in using these techniques to characterize whole virus-ligand interactions, as the methods allow for more accurate characterization than that of a viral subunit-ligand interaction. This review aims to summarize and evaluate the uses of these technologies specifically in virus-ligand and virus-like particle-ligand binding cases to guide the field towards studies that apply these robust methods for whole virus-based studies.


Biosensing Techniques , Surface Plasmon Resonance , Biological Assay , Interferometry/methods , Kinetics , Ligands
11.
medRxiv ; 2022 Mar 14.
Article En | MEDLINE | ID: mdl-35262095

Background: In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies." SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. Methods: To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. SARS-CoV-2 serology standard reference material and First WHO International Standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. Results: SeroNet institutions reported development of a total of 27 ELISA methods, 13 multiplex assays, 9 neutralization assays, and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. Conclusions: SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 virus and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons.

12.
Emerg Infect Dis ; 28(2): 303-313, 2022 02.
Article En | MEDLINE | ID: mdl-35075998

Cache Valley virus (CVV) is a mosquitoborne virus that infects livestock and humans. We report results of surveillance for CVV in New York, USA, during 2000-2016; full-genome analysis of selected CVV isolates from sheep, horse, humans, and mosquitoes from New York and Canada; and phenotypic characterization of selected strains. We calculated infection rates by using the maximum-likelihood estimation method by year, region, month, and mosquito species. The highest maximum-likelihood estimations were for Anopheles spp. mosquitoes. Our phylogenetic analysis identified 2 lineages and found evidence of segment reassortment. Furthermore, our data suggest displacement of CVV lineage 1 by lineage 2 in New York and Canada. Finally, we showed increased vector competence of An. quadrimaculatus mosquitoes for lineage 2 strains of CVV compared with lineage 1 strains.


Anopheles , Bunyamwera virus , Animals , Bunyamwera virus/genetics , Horses , Mosquito Vectors , New York/epidemiology , Phylogeny , Sheep
13.
Disabil Health J ; 15(1): 101215, 2022 01.
Article En | MEDLINE | ID: mdl-34556445

BACKGROUND: Children with disabilities present with high obesity rates. OBJECTIVE: This study explored the parental experience of adopting healthy lifestyle choices, for children with disabilities, who received dietetic weight management advice. METHODS: Semi-structured qualitative interviews were carried out with eight parents/carers in their own homes or healthcare setting in an inner London locality, or by telephone. Data was analyzed using an interpretative phenomenological analysis (IPA) approach. RESULTS: Five superordinate themes emerged: 1. Strategies to promote healthy lifestyles: encouraging physical activity, limiting access to food and taking a gradual approach to making lifestyle changes. 2. Challenges to adopting healthy lifestyles: selective eating patterns, the high cost of healthy foods and parental/carer lack of time. 3. The role of healthcare professionals (HCPs): revealed that not all parents/carers received advice or support, prior to dietetic referral, when managing their child's weight. Feeling reassured by HCPs was valued. Parents/carers reported a positive experience of seeing the dietitian, as they appreciated receiving practical and individualized advice. 4. Support needs: family support and support from families with children with disabilities was explored. 5. Parent/carer wellbeing: such as stress was found to have a detrimental impact on parents making healthy lifestyle changes. CONCLUSIONS: Adopting a healthy lifestyle involved a variety of strategies and challenges, some of which are specific to this population group and should be considered by HCPs, when having weight-related discussions and offering advice. Parental/carer support needs and wellbeing should also be taken into consideration when planning weight management services for this population group.


Disabled Children , Overweight , Child , Healthy Lifestyle , Humans , Obesity , Parents , Qualitative Research
14.
Microbiol Spectr ; 9(3): e0088621, 2021 12 22.
Article En | MEDLINE | ID: mdl-34787495

The evaluation of humoral protective immunity against SARS-CoV-2 remains crucial in understanding both natural immunity and protective immunity conferred by the several vaccines implemented in the fight against COVID-19. The reference standard for the quantification of antibodies capable of neutralizing SARS-CoV-2 is the plaque-reduction neutralization test (PRNT). However, given that it is a laboratory-developed assay, validation is crucial in order to ensure sufficient specificity and intra- and interassay precision. In addition, a multitude of other serological assays have been developed, including enzyme-linked immunosorbent assay (ELISA), flow cytometry-based assays, luciferase-based lentiviral pseudotype assays, and commercially available human ACE2 receptor-blocking antibody tests, which offer practical advantages in the evaluation of the protective humoral response against SARS-CoV-2. In this study, we validated a SARS-CoV-2 PRNT to assess both 50% and 90% neutralization of SARS-CoV-2 according to guidelines outlined by the World Health Organization. Upon validation, the reference-standard PRNT demonstrated excellent specificity and both intra- and interassay precision. Using the validated assay as a reference standard, we characterized the neutralizing antibody response in specimens from patients with laboratory-confirmed COVID-19. Finally, we conducted a small-scale multilaboratory comparison of alternate SARS-CoV-2 PRNTs and surrogate neutralization tests. These assays demonstrated substantial to perfect interrater agreement with the reference-standard PRNT and offer useful alternatives to assess humoral immunity against SARS-CoV-2. IMPORTANCE SARS-CoV-2, the causal agent of COVID-19, has infected over 246 million people and led to over 5 million deaths as of October 2021. With the approval of several efficacious COVID-19 vaccines, methods to evaluate protective immune responses will be crucial for the understanding of long-term immunity in the rapidly growing vaccinated population. The PRNT, which quantifies SARS-CoV-2-neutralizing antibodies, is used widely as a reference standard to validate new platforms but has not undergone substantial validation to ensure excellent inter- and intraassay precision and specificity. Our work is significant, as it describes the thorough validation of a PRNT, which we then used as a reference standard for the comparison of several alternative serological methods to measure SARS-CoV-2-neutralizing antibodies. These assays demonstrated excellent agreement with the reference-standard PRNT and include high-throughput platforms, which can greatly enhance capacity to assess both natural and vaccine-induced protective immunity against SARS-CoV-2.


COVID-19 Serological Testing/methods , COVID-19/diagnosis , COVID-19/immunology , Immunity, Humoral/immunology , Neutralization Tests/methods , SARS-CoV-2/immunology , Angiotensin-Converting Enzyme 2 , Animals , Antibodies, Neutralizing , Antibodies, Viral/immunology , COVID-19 Vaccines/immunology , Chlorocebus aethiops , Diagnostic Tests, Routine , Enzyme-Linked Immunosorbent Assay/methods , HEK293 Cells , Humans , Immunity , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Vero Cells
15.
Parasit Vectors ; 14(1): 573, 2021 Nov 12.
Article En | MEDLINE | ID: mdl-34772442

BACKGROUND: Vector-borne pathogens must survive and replicate in the hostile environment of an insect's midgut before successful dissemination. Midgut microbiota interfere with pathogen infection by activating the basal immunity of the mosquito and by synthesizing pathogen-inhibitory metabolites. METHODS: The goal of this study was to assess the influence of Zika virus (ZIKV) infection and increased temperature on Aedes albopictus midgut microbiota. Aedes albopictus were reared at diurnal temperatures of day 28 °C/night 24 °C (L) or day 30 °C/night 26 °C (M). The mosquitoes were given infectious blood meals with 2.0 × 108 PFU/ml ZIKV, and 16S rRNA sequencing was performed on midguts at 7 days post-infectious blood meal exposure. RESULTS: Our findings demonstrate that Elizabethkingia anophelis albopictus was associated with Ae. albopictus midguts exposed to ZIKV infectious blood meal. We observed a negative correlation between ZIKV and E. anophelis albopictus in the midguts of Ae. albopictus. Supplemental feeding of Ae. albopictus with E. anophelis aegypti and ZIKV resulted in reduced ZIKV infection rates. Reduced viral loads were detected in Vero cells that were sequentially infected with E. anophelis aegypti and ZIKV, dengue virus (DENV), or chikungunya virus (CHIKV). CONCLUSIONS: Our findings demonstrate the influence of ZIKV infection and temperature on the Ae. albopictus microbiome along with a negative correlation between ZIKV and E. anophelis albopictus. Our results have important implications for controlling vector-borne pathogens.


Aedes/microbiology , Aedes/virology , Flavobacteriaceae/physiology , Mosquito Vectors/microbiology , Mosquito Vectors/virology , Zika Virus/physiology , Animals , Flavobacteriaceae/genetics , Humans , Temperature , Zika Virus/genetics , Zika Virus Infection/transmission , Zika Virus Infection/virology
16.
Cell Rep Med ; 2(7): 100329, 2021 07 20.
Article En | MEDLINE | ID: mdl-34151306

Coronavirus disease 2019 (COVID-19) is associated with a wide spectrum of disease presentation, ranging from asymptomatic infection to acute respiratory distress syndrome (ARDS). Paradoxically, a direct relationship has been suggested between COVID-19 disease severity and the levels of circulating severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-specific antibodies, including virus-neutralizing titers. A serological analysis of 536 convalescent healthcare workers reveals that SARS-CoV-2-specific and virus-neutralizing antibody levels are elevated in individuals that experience severe disease. The severity-associated increase in SARS-CoV-2-specific antibody is dominated by immunoglobulin G (IgG), with an IgG subclass ratio skewed toward elevated receptor binding domain (RBD)- and S1-specific IgG3. In addition, individuals that experience severe disease show elevated SARS-CoV-2-specific antibody binding to the inflammatory receptor FcÉ£RIIIa. Based on these correlational studies, we propose that spike-specific IgG subclass utilization may contribute to COVID-19 disease severity through potent Fc-mediated effector functions. These results may have significant implications for SARS-CoV-2 vaccine design and convalescent plasma therapy.


Antibodies, Viral/blood , COVID-19/blood , Immunoglobulin G/blood , Adult , Female , Humans , Male , Middle Aged , SARS-CoV-2/immunology , Severity of Illness Index
17.
Virology ; 561: 58-64, 2021 09.
Article En | MEDLINE | ID: mdl-34147955

Pathogens are transmitted from one host to another either by vertical transmission (VT) or horizontal transmission (HT). Mosquito-borne arboviruses (arthropod-borne viruses), including several clinically important viruses such as dengue, Zika, West Nile and chikungunya viruses persist in nature by both VT and HT. VT may also serve as an essential link in the transmission cycle during adverse environmental conditions. VT rates (VTRs) vary between virus families and even among viruses within the same genus. The mechanism behind these differences in VTRs among viruses is poorly understood. For efficient VT to occur, viruses must infect the mosquito germline. Here, we show that Zika virus infects mosquito ovaries and is transmitted vertically at a low rate. The infected progeny derive from mosquitoes with infected ovaries. The prevalence of ovary infection increases after a second non-infectious blood meal following an infectious blood meal.


Aedes/virology , Zika Virus/physiology , Animals , Cell Line , Female , Ovary/virology , Viral Plaque Assay
18.
J Clin Endocrinol Metab ; 106(5): e2025-e2034, 2021 04 23.
Article En | MEDLINE | ID: mdl-33524125

PURPOSE: Comorbidities making up metabolic syndrome (MetS), such as obesity, type 2 diabetes, and chronic cardiovascular disease can lead to increased risk of coronavirus disease-2019 (COVID-19) with a higher morbidity and mortality. SARS-CoV-2 antibodies are higher in severely or critically ill COVID-19 patients, but studies have not focused on levels in convalescent patients with MetS, which this study aimed to assess. METHODS: This retrospective study focused on adult convalescent outpatients with SARS-CoV-2 positive serology during the COVID-19 pandemic at NewYork Presbyterian/Weill Cornell. Data collected for descriptive and correlative analysis included SARS-COV-2 immunoglobin G (IgG) levels and history of MetS comorbidities from April 17, 2020 to May 20, 2020. Additional data, including SARS-CoV-2 IgG levels, body mass index (BMI), hemoglobin A1c (HbA1c) and lipid levels were collected and analyzed for a second cohort from May 21, 2020 to June 21, 2020. SARS-CoV-2 neutralizing antibodies were measured in a subset of the study cohort. RESULTS: SARS-CoV-2 IgG levels were significantly higher in convalescent individuals with MetS comorbidities. When adjusted for age, sex, race, and time duration from symptom onset to testing, increased SARS-CoV-2 IgG levels remained significantly associated with obesity (P < 0.0001). SARS-CoV-2 IgG levels were significantly higher in patients with HbA1c ≥6.5% compared to those with HbA1c <5.7% (P = 0.0197) and remained significant on multivariable analysis (P = 0.0104). A positive correlation was noted between BMI and antibody levels [95% confidence interval: 0.37 (0.20-0.52) P < 0.0001]. Neutralizing antibody titers were higher in COVID-19 individuals with BMI ≥ 30 (P = 0.0055). CONCLUSION: Postconvalescent SARS-CoV-2 IgG and neutralizing antibodies are elevated in obese patients, and a positive correlation exists between BMI and antibody levels.


Antibodies, Neutralizing/immunology , COVID-19/immunology , Immunoglobulin G/immunology , Metabolic Syndrome/immunology , Adult , Antibodies, Neutralizing/blood , COVID-19/blood , COVID-19/complications , Diabetes Mellitus, Type 2/blood , Diabetes Mellitus, Type 2/immunology , Diabetes Mellitus, Type 2/virology , Female , Humans , Immunoglobulin G/blood , Male , Metabolic Syndrome/blood , Metabolic Syndrome/virology , Middle Aged , Obesity/blood , Obesity/immunology , Obesity/virology , Retrospective Studies
19.
J Infect Dis ; 223(5): 743-751, 2021 03 03.
Article En | MEDLINE | ID: mdl-33417696

BACKGROUND: Coronavirus disease 2019 (COVID-19) convalescent plasma (CCP) received an Emergency Use Authorization by the US Food and Drug Administration (FDA). CCP with a signal-to-cutoff ratio of ≥12 using the Ortho VITROS severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) immunoglobulin G (IgG) test (OVSARS2IgG) is permitted to be labeled "high titer." Little is known about the relationship between OVSARS2IgG ratio and neutralizing capacity of plasma/sera against genuine SARS-CoV-2. METHODS: Nine hundred eighty-one samples from 196 repeat CCP donors 0-119 days post-initial donation (DPID) were analyzed. Neutralizing capacity was assessed for 50% (PRNT50) and 90% (PRNT90) reduction of infectious virus using the gold standard plaque reduction neutralization test (PRNT). A subset of 91 donations was evaluated by OVSARS2IgG and compared to PRNT titers for diagnostic accuracy. RESULTS: Of donations, 32.7%/79.5% (PRNT90/PRNT50) met a 1:80 titer initially but only 14.0%/48.8% (PRNT90/PRNT50) met this cutoff ≥85 DPID. Correlation of OVSARS2IgG results to neutralizing capacity allowed extrapolation to CCP therapy results. CCP with OVSARS2IgG ratios equivalent to a therapeutically beneficial group had neutralizing titers of ≥1:640 (PRNT50) and/or ≥1:80 (PRNT90). Specificity and positive predictive value of the OVSARS2IgG for qualifying highly neutralizing CCP was optimal using ratios significantly greater than the FDA cutoff. CONCLUSIONS: This information provides a basis for refining the recommended properties of CCP used to treat COVID-19.


COVID-19/immunology , COVID-19/therapy , SARS-CoV-2/immunology , Cohort Studies , Female , Humans , Immunization, Passive/standards , Male , Middle Aged , Neutralization Tests , Retrospective Studies , Sensitivity and Specificity , Time Factors , COVID-19 Serotherapy
20.
Biosens Bioelectron ; 178: 113008, 2021 Apr 15.
Article En | MEDLINE | ID: mdl-33515984

The association of mortality with the early humoral response to SARS-CoV-2 infection within the first few days after onset of symptoms (DAOS) has not been thoroughly investigated partly due to a lack of sufficiently sensitive antibody testing methods. Here we report two sensitive and automated testing-on-a-probe (TOP) biosensor assays for SARS-CoV-2 viral specific total antibodies (TAb) and surrogate neutralizing antibodies (SNAb), which are suitable for clinical use. The TOP assays employ an RBD-coated quartz probe using a Cy5-Streptavidin-polysacharide conjugate to improve sensitivity and minimize interference. Disposable cartridges containing pre-dispensed reagents require no liquid manipulation or fluidics during testing. The TOP-TAb assay exhibited higher sensitivity in the 0-7 DAOS window than a widely used FDA-EUA assay. The rapid and automated TOP-SNAb correlated well with two well-established SARS-CoV-2 virus neutralization tests. The clinical utility of the TOP assays was demonstrated by evaluating early antibody responses in 120 SARS-CoV-2 RT-PCR positive adult hospitalized patients. Higher TAb and SNAb positivity rates and more robust antibody responses at patient's initial hospital presentation were seen in inpatients who survived COVID-19 than those who died in the hospital. Survival analysis using the Cox Proportional Hazards Model showed that patients who had negative TAb and/or SNAb at initial hospital presentation were at a higher risk of in-hospital mortality. Furthermore, TAb and SNAb levels at presentation were inversely associated with SARS-CoV-2 viral load based on concurrent RT-PCR testing. Overall, the sensitive and automated TAb and SNAb assays allow the detection of early SARS-CoV-2 antibodies which associate with mortality.


Antibodies, Viral/blood , Biosensing Techniques/instrumentation , COVID-19 Serological Testing/instrumentation , COVID-19/immunology , COVID-19/mortality , SARS-CoV-2/immunology , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/blood , Biosensing Techniques/statistics & numerical data , COVID-19/virology , COVID-19 Nucleic Acid Testing/statistics & numerical data , COVID-19 Serological Testing/statistics & numerical data , Cohort Studies , Equipment Design , Female , Humans , Male , Middle Aged , Neutralization Tests/statistics & numerical data , New York City/epidemiology , Pandemics , Proportional Hazards Models , Retrospective Studies , Risk Factors , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Young Adult
...