Phys Eng Sci Med ; 47(2): 531-538, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38206532

RESUMEN

With the rising use of Computed Tomography (CT) in diagnostic radiology, there are concerns regarding radiation exposure to sensitive groups, including pregnant patients. Accurately determining the radiation dose to the fetus during CT scans is essential to balance diagnostic efficacy with patient safety. This study assessed the accuracy of using the female uterus as a surrogate for fetal radiation dose during CT imaging. The study used common CT protocols to encompass various scenarios, including primary beam, scatter, and partial exposure. The computational program NCICT was used to calculate radiation doses for an adult female and a fetus phantom. The study highlighted that using the uterus for dose estimation can result in consistent underestimations of the effective dose, particularly when the fetus lies within the primary radiation beam. These discrepancies may influence clinical decisions, affecting care strategies and perceptions of associated risks. In conclusion, while the female uterus can indicate fetal radiation dose if the fetus is outside the primary beam, it is unreliable when the fetus is within the primary beam. More reliable abdomen/pelvic organs were recommended.


Asunto(s)
Feto , Fantasmas de Imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , Femenino , Embarazo , Feto/diagnóstico por imagen , Feto/efectos de la radiación , Útero/diagnóstico por imagen , Adulto , Exposición a la Radiación
2.
Phys Med ; 114: 103142, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37748357

RESUMEN

PURPOSE: This study aimed to compare the average Water Equivalent Diameter (WED) values obtained from CTContour, an open-source program for Size-Specific Dose Estimate (SSDE) and WED calculation, and vendor-specific values provided by Philips scanners. METHODS: A random sample of 50 adult and 50 paediatric abdomen-pelvis protocol CT images from Philips scanners were chosen at our Hospital and analysed using CTContour, and extracting average WED values from Philips from the images DICOM headers. The average WED values from the two methods were compared via Bland-Altman analysis to assess their agreement and reliability. RESULTS: The average WED values obtained from CTContour were found to be slightly lower than those obtained from the vendor-specific calculations, with mean disagreements of -5.62% and -2.88% for the adult and paediatric datasets, respectively, with both methods providing clinically acceptable estimations of average WED. There was no statistically significant correlation between body habitus and the level of disagreement between methods. CONCLUSIONS: This study demonstrates that CTContour can provide average WED measurements comparable to the vendor-specific calculations for SSDE and WED in CT dosimetry. Differences between programs are likely due to inherent differences in the methods employed to estimate WED automatically. Further research is warranted to validate these results for additional CT protocols beyond abdomen-pelvis studies.


Asunto(s)
Radiometría , Agua , Adulto , Humanos , Niño , Dosis de Radiación , Reproducibilidad de los Resultados , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen