Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Nutr Metab Cardiovasc Dis ; 33(12): 2398-2405, 2023 Dec.
Article En | MEDLINE | ID: mdl-37788956

BACKGROUND AND AIM: Elevated triglyceride (TG) levels seem to identify subjects at increased cardiovascular risk, independent of LDL-C levels. We sought to evaluate the predictive role of hypertriglyceridemia, defined as TG levels ≥150 mg/dl, in very high risk (VHR) patients with chronic coronary syndromes (CCS) treated with statins. METHODS AND RESULTS: Using the data from the STable Coronary Artery Diseases RegisTry (START) study, an Italian nationwide registry, we assessed the association between the TG levels and baseline clinical characteristics, pharmacological treatment and major adverse cardio-cerebrovascular events (MACCE) at 1 year in a large cohort of statin-treated patients at VHR. Of the 4751 consecutive patients with CCS enrolled in the registry and classified as VHR, 2652 (55.8%) had TG values available (mean 120.6 ± 54.9) and were treated with at least a statin at baseline: 2019 (76.1%) with TG < 150 and 633 (23.9%) with TG ≥ 150 mg/dl. At 1 year from enrolment, MACCE occurred in 168 (6.3%) patients, without differences between the two groups of TG (5.9 vs 7.6%; p = 0.14). At multivariable analysis, hypertriglyceridemia did not result as independent predictor of the MACCE (hazard ratio: 1.16; 95% confidence intervals: 0.82-1.64; p = 0.42). CONCLUSIONS: In the present large, nationwide cohort of consecutive CCS patients at VHR with statin-controlled LDL-C levels, hypertriglyceridemia was present in around 24% of cases and did not result as predictor of MACCE at 1 year. Further studies with a longer follow-up and larger sample size are needed to better define the prognostic role of TG levels when intensive LDL lowering therapies are used.


Hydroxymethylglutaryl-CoA Reductase Inhibitors , Hypertriglyceridemia , Humans , Hydroxymethylglutaryl-CoA Reductase Inhibitors/adverse effects , Cholesterol, LDL , Prevalence , Triglycerides , Hypertriglyceridemia/diagnosis , Hypertriglyceridemia/drug therapy , Hypertriglyceridemia/epidemiology
2.
J Hypertens ; 27(8): 1697-704, 2009 Aug.
Article En | MEDLINE | ID: mdl-19424088

OBJECTIVES: We tested the hypothesis that the voltages of QRS on ECG improve risk stratification in hypertensive patients without left ventricular hypertrophy on ECG. METHODS AND RESULTS: We studied 2042 initially untreated patients with hypertension (mean age 49 years, 46% women) without left ventricular hypertrophy on ECG and no history of cardiovascular disease. At entry, all patients underwent diagnostic tests, including 24-h ambulatory blood pressure monitoring and echocardiography. Among the different ECG voltages, the R wave in lead aVL showed the closest association with left ventricle (LV) mass (r = 0.31; P < 0.001), followed by the R wave in D1 (r = 0.25) and the S wave in V3 (r = 0.22). Patients were followed up for a mean of 7.7 years (range 1-22 years), and treatment was tailored individually. During follow-up, there were 188 major cardiovascular events. The relationship between LV voltage and outcome was assessed using a Cox model with adjustment for age, sex, diabetes, smoking, total cholesterol, serum creatinine, LV mass on echocardiography and average 24-h ambulatory blood pressure. A 0.1 mV higher R wave voltage in lead aVL was associated with a 9% higher risk of cardiovascular disease (95% confidence interval = 0.04-0.15%; P < 0.001). Other ECG voltages and minor repolarization changes were not related to clinical outcome. CONCLUSION: Our results show for the first time that the voltage of the R wave in lead aVL improves cardiovascular risk stratification in hypertensive patients without left ventricular hypertrophy on ECG. Its prognostic value is independent of LV mass on echocardiography and 24-h ambulatory blood pressure.


Electrocardiography , Hypertension/physiopathology , Hypertrophy, Left Ventricular/physiopathology , Adult , Aged , Cardiovascular Diseases/etiology , Female , Humans , Male , Middle Aged , Proportional Hazards Models , Risk Factors
3.
Blood Press Monit ; 11(4): 223-7, 2006 Aug.
Article En | MEDLINE | ID: mdl-16810033

OBJECTIVES: We tested the accuracy of the UA-705 blood pressure semi-automatic monitor. METHODS: Device evaluation was performed according to the modified British Hypertension Society protocol released in 1993. Eighty-five patients with characteristics outlined in the British Hypertension Society protocol were recruited among those attending our out-patient clinic. Sequential readings were taken for the main validation test. Outcome was classified according to the British Hypertension Society criteria, which are based on four zones of accuracy differing from the mercury standard by 5, 10 and 15 mmHg, or more. RESULTS: The mean blood pressure difference (+ or -1 SD) between device and observers was 0.4 mmHg (SD 7.7) for systolic blood pressure and 0.3 mmHg (SD 8.2) for diastolic blood pressure. Overall, 96% (observer 1) and 95% (observer 2) of readings between device and observers differed by 15 mmHg or less for both systolic and diastolic blood pressure. The device achieved a grade A for both systolic and diastolic blood pressure. CONCLUSIONS: This study shows that the A&D UA-705 device satisfies the British Hypertension Society standard for accuracy by achieving a grade A for both systolic and diastolic blood pressure.


Blood Pressure Monitoring, Ambulatory/standards , Adult , Automation , Diastole , Female , Humans , Male , Middle Aged , Sphygmomanometers , Systole
...