Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Card Surg ; 36(12): 4770-4772, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34547128

RESUMEN

Patients with severely calcified aorta undergoing conventional cardiac surgery are at increased risk for postoperative neurologic deficits. Implementation of cerebroprotective devices may substantially reduce or even eliminate the risk of the adverse neurologic events, thus enabling surgical therapy, especially when interventional treatment cannot be considered an alternative option.


Asunto(s)
Enfermedades de la Aorta , Procedimientos Quirúrgicos Cardíacos , Aorta , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Puente de Arteria Coronaria , Humanos
2.
J Invasive Cardiol ; 33(5): E356-E364, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33932281

RESUMEN

OBJECTIVES: Both balloon-expandable and self-expanding transcatheter aortic valves are used for transcatheter aortic valve implantation (TAVI). We compared procedural and clinical outcome variables of Sapien 3 and Evolut R/Pro in an all-comers collective. METHODS: In this single-center registry, patients were consecutively treated with the Sapien 3 from November 2014 to March 2017 (n = 129) and from April 2017 to December 2018 mainly (>95%) with the Evolut R/Pro (n = 124), due to a switch in the main TAVI supplier driven by hospital management. Data were retrospectively analyzed before and after the switch. RESULTS: One-year follow-up data were available for 122 (94%) of the Sapien and 112 (90%) of the Evolut patients. Baseline characteristics were comparable (EuroSCORE: Sapien 21.8 ± 0.9% vs Evolut 22.5 ± 0.8%; P=.20). Evolut implantation was associated with a higher radiation dose (Sapien 35770 ± 2345 mGy•cm² vs Evolut 85072 ± 8202 mGy•cm²; P<.001), more postimplantation balloon dilations (Sapien 17.1% vs Evolut 37.1%; P<.001), but similar procedure time (Sapien 75.2 ± 3.8 min vs Evolut 74.6 ± 3 min; P=.30). In-hospital mortality (Sapien 3.1% vs Evolut 4.0%; P=.70), all-cause mortality (Sapien 13.2% vs Evolut 15.3%; P=.70), all-stroke rate (Sapien 1.5% vs Evolut 6.5%; P=.05), and pacemaker implantation rate (Sapien 13.2% vs Evolut 18.5%; P=.30) were similar at 1 year. Permanent pacemaker rate was numerically higher in the first 6 months with Evolut (<6 months 26.7% vs >6 months 16%; P=.62); furthermore, radiation dose and balloon dilations also suggest a learning curve with Evolut. CONCLUSIONS: Switching from Sapien 3 to Evolut R/Pro was not associated with a difference regarding periprocedural or 1-year clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Eur Heart J Acute Cardiovasc Care ; 5(6): 419-427, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26460326

RESUMEN

AIMS: To evaluate the diagnostic performance of high-sensitivity troponin I (hsTnI) and other novel biomarkers for diagnosing non-ST-segment elevation myocardial infarction (NSTEMI) in patients with atrial fibrillation. METHODS: In an acute chest pain cohort (N=1673), mean age 61.4±13.6 (34% female), we measured hsTnI and 13 established and novel biomarkers reflecting ischaemia, necrosis, inflammation, myocardial stress, angiogenesis on admission and after three hours in order to investigate their diagnostic accuracy for NSTEMI. RESULTS: In atrial fibrillation patients (N=299) hsTnI on admission had the best discriminatory ability for NSTEMI (area under the curve 0.97) with only two novel biomarkers, copeptin and heart-type fatty acid binding protein, having area under the curve >0.70. Measured biomarkers showed comparable discriminatory ability in atrial fibrillation and non-atrial fibrillation patients. The combination of hsTnI on admission with additional biomarkers did not clinically significantly improve diagnostic performance. In atrial fibrillation patients, hsTnI concentrations ⩽21.7 ng/L (99th percentile in a healthy German cohort) on admission gave a negative predictive value of ~100% (95% confidence interval 97-100%). The combination of hsTnI on admission and absolute change of hsTnI concentration after three hours of ⩾40 ng/L resulted in a positive predictive value of 81.2% and sensitivity of 88.6%. Diagnostic accuracy was validated in an independent cohort (N=1076). CONCLUSION: The diagnostic accuracy of hsTnI in patients with acute chest pain and atrial fibrillation is high and comparable to those without atrial fibrillation. Absolute change in hsTnI concentration enhanced diagnostic performance. No clinically relevant improvement was achieved by adding other biomarkers.


Asunto(s)
Fibrilación Atrial/complicaciones , Infarto del Miocardio sin Elevación del ST/diagnóstico , Troponina T/sangre , Anciano , Angina de Pecho/etiología , Área Bajo la Curva , Fibrilación Atrial/sangre , Biomarcadores Farmacológicos/sangre , Diagnóstico Precoz , Proteína 3 de Unión a Ácidos Grasos , Proteínas de Unión a Ácidos Grasos/sangre , Femenino , Glicopéptidos/sangre , Humanos , Masculino , Estudios Prospectivos , Sensibilidad y Especificidad
4.
Clin Chem Lab Med ; 53(5): 699-706, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25283141

RESUMEN

BACKGROUND: The 99th percentile of cardiac troponin levels, determined in a reference population, is accepted as threshold for diagnosis of acute myocardial infarction (AMI). However, there is no common consensus of how to define the reference population. The aim of the present study was to determine 99th percentile reference values, determined by a high-sensitivity assay (hsTnI), according to different health status and cardiovascular risk factor prevalence in a large population-based sample. METHODS: Troponin I was determined using the Abbott ARCHITECT STAT highly sensitive troponin I immunoassay in 4138 participants of the Gutenberg Health Study. RESULTS: hsTnI was detectable in 81.6% of all individuals. The 99th percentile of the overall population was 27 ng/L. Age and gender had a prominent influence on these values. Exclusion of individuals with elevated natriuretic peptide levels or cardiac abnormalities resulted in lower 99th percentile values, whereas exclusion of individuals with an impaired estimated glomerular filtration rate (eGFR) or with prevalent coronary artery disease/myocardial infarction (CAD/MI) did not result in a meaningful change. CONCLUSIONS: Troponin I, measured by a high-sensitivity assay, can be reliably detected in the vast majority of the general population. hsTnI values were dependent on age, gender as well as structural and functional cardiac abnormalities.


Asunto(s)
Análisis Químico de la Sangre/normas , Límite de Detección , Miocardio/metabolismo , Salud Pública , Troponina I/sangre , Europa (Continente) , Femenino , Estado de Salud , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia
5.
Eur Heart J ; 36(6): 369-76, 2015 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-24786301

RESUMEN

AIMS: This randomized controlled trial (RCT) evaluated whether a process with single combined testing of copeptin and troponin at admission in patients with low-to-intermediate risk and suspected acute coronary syndrome (ACS) does not lead to a higher proportion of major adverse cardiac events (MACE) than the current standard process (non-inferiority design). METHODS AND RESULTS: A total of 902 patients were randomly assigned to either standard care or the copeptin group where patients with negative troponin and copeptin values at admission were eligible for discharge after final clinical assessment. The proportion of MACE (death, survived sudden cardiac death, acute myocardial infarction (AMI), re-hospitalization for ACS, acute unplanned percutaneous coronary intervention, coronary artery bypass grafting, or documented life threatening arrhythmias) was assessed after 30 days. Intention to treat analysis showed a MACE proportion of 5.17% [95% confidence intervals (CI) 3.30-7.65%; 23/445] in the standard group and 5.19% (95% CI 3.32-7.69%; 23/443) in the copeptin group. In the per protocol analysis, the MACE proportion was 5.34% (95% CI 3.38-7.97%) in the standard group, and 3.01% (95% CI 1.51-5.33%) in the copeptin group. These results were also corroborated by sensitivity analyses. In the copeptin group, discharged copeptin negative patients had an event rate of 0.6% (2/362). CONCLUSION: After clinical work-up and single combined testing of troponin and copeptin to rule-out AMI, early discharge of low- to intermediate risk patients with suspected ACS seems to be safe and has the potential to shorten length of stay in the ED. However, our results need to be confirmed in larger clinical trials or registries, before a clinical directive can be propagated.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Glicopéptidos/metabolismo , Troponina T/metabolismo , Arritmias Cardíacas , Biomarcadores/metabolismo , Puente de Arteria Coronaria , Muerte Súbita Cardíaca/etiología , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Alta del Paciente , Readmisión del Paciente , Intervención Coronaria Percutánea , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...