Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Invasive Cardiol ; 31(5): E76-E82, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31034438

RESUMEN

BACKGROUND: In transcatheter aortic valve implantation (TAVI), prosthesis over-sizing prevents paravalvular leak (PVL). Strategies of over-sizing for self-expanding bioprostheses are not well established at present. METHODS: Patients with aortic valve stenosis scheduled for TAVI underwent preprocedural multislice computed tomography. Based on the degree of over-sizing, a ROC curve was drawn to define the optimal value of valve sizing for reducing PVL after TAVI. RESULTS: A total of 152 consecutive patients were included in the study (mean age, 79.95 ± 7.71 years; log EuroScore: 23.87 ± 8.93%). Based on the ROC curve, sizing of 14% was the optimal that would lead to less moderate/severe PVL (P<.01). Group 1 was defined as sizing <14% (n = 49 patients) and group 2 was defined as sizing ≥14% (n = 103 patients). During a follow-up period of 36 ± 14 months, a total of 9 patients died from group 1 vs 4 patients from group 2 (P<.01). Two of the patients who died had moderate/severe PVL and 11 had no/mild PVL (P=.27). From the population, a total of 49 patients (32%) were found to be in the "borderline" zone. Patients who received the smaller valve had lower mean left ventricular outflow tract diameter (P=.048), higher rate of calcium load (mild: 10 [32%] vs 13 [72%]; moderate: 16 [52%] vs 3 [17%]; severe: 5 [16%] vs 2 [11%]; P=.02) and lower mean of sinus of Valsalva diameter (P=.046) compared with patients who received the bigger valve. CONCLUSIONS: In patients undergoing TAVI, over-sizing the prosthesis at least 14% reduces PVL. In borderline cases, taking into consideration additional anatomical parameters may result in low rates of PVL.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/prevención & control , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Femenino , Grecia , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/normas , Humanos , Masculino , Tomografía Computarizada Multidetector/métodos , Tomografía Computarizada Multidetector/estadística & datos numéricos , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Cuidados Preoperatorios/métodos , Falla de Prótesis/etiología , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos
2.
Curr Med Chem ; 26(5): 864-872, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-28748765

RESUMEN

Aortic valve stenosis is one of the most common valvular heart disorders and the prevalence will rise as the population ages. Once symptomatic patients with aortic valve stenosis tend to fare worse with high mortality rates. Aortic valve replacement is indicated in these patients and besides the standard surgical replacement, a less invasive approach, transcatheter aortic valve implantation, has gained momentum and has showed promising and solid results in patients with high surgical risk. An important aspect of evaluating patients with aortic valve stenosis is the ability to choose the best possible candidate for the procedure. In addition, predicting the short and long-term clinical outcomes after the valve replacement could offer the treating physicians a better insight and provide information for optimal therapy. Biomarkers are biological parameters that can be objectively measured and evaluated as indicators of normal biological processes and are easily monitored. The aim of this review is to critically assess some of the most widely used biomarkers at present (natriuretic peptides, troponins, C-reactive protein) and provide an insight in novel biomarkers that are currently being investigated (galectin-3, growth differentiation factor-15, microRNAs) for possible diagnostic and prognostic use in aortic valve stenosis and transcatheter aortic valve implantation respectively.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Animales , Biomarcadores/análisis , Proteína C-Reactiva/análisis , Galectina 3/análisis , Factor 15 de Diferenciación de Crecimiento/análisis , Humanos , MicroARNs/análisis , Péptidos Natriuréticos/análisis , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Troponina/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA