Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 9 de 9
1.
Heart Rhythm ; 2024 Feb 08.
Article En | MEDLINE | ID: mdl-38336193

BACKGROUND: The PRAETORIAN score estimates the risk of failure of subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy by using generator and lead positioning on bidirectional chest radiographs. The PRospective randomized compArative trial of subcutanEous implanTable cardiOverter-defibrillatoR ImplANtation with and without DeFibrillation Testing (PRAETORIAN-DFT) investigates whether PRAETORIAN score calculation is noninferior to defibrillation testing (DFT) with regard to first shock efficacy in spontaneous events. OBJECTIVE: This prespecified subanalysis assessed the predictive value of the PRAETORIAN score for defibrillation success in induced ventricular arrhythmias. METHODS: This multicenter investigator-initiated trial randomized 965 patients between DFT and PRAETORIAN score calculation after de novo S-ICD implantation. Successful DFT was defined as conversion of induced ventricular arrhythmia in <5 seconds from shock delivery within 2 attempts. Bidirectional chest radiographs were obtained after implantation. The predictive value of the PRAETORIAN score for DFT success was calculated for patients in the DFT arm. RESULTS: In total, 482 patients were randomized to undergo DFT. Of these patients, 457 (95%) underwent DFT according to protocol, of whom 445 (97%) had successful DFT and 12 (3%) had failed DFT. A PRAETORIAN score of ≥90 had a positive predictive value of 25% for failed DFT, and a PRAETORIAN score of <90 had a negative predictive value of 99% for successful DFT. A PRAETORIAN score of ≥90 was the strongest independent predictor for failed DFT (odds ratio 33.77; confidence interval 6.13-279.95; P < .001). CONCLUSION: A PRAETORIAN score of <90 serves as a reliable indicator for DFT success in patients with S-ICD, and a PRAETORIAN score of ≥90 is a strong predictor for DFT failure.

2.
BJOG ; 2024 Feb 07.
Article En | MEDLINE | ID: mdl-38326282

OBJECTIVE: Data and guidelines are lacking, so implantable cardioverter-defibrillators (ICDs) are often deactivated during labour to prevent inappropriate shocks. This study aimed to ascertain the safety of an activated ICD during labour. DESIGN: An observational study was performed. SETTING: Dutch hospitals. POPULATION OR SAMPLE: A total of 41 childbirths were included of 26 patients who gave birth between February 2009 and November 2018 after receiving an ICD in our tertiary hospital. Five of these childbirths were attended by the research team between December 2018 and August 2020, during which the ICD remained active. METHODS: Groups were made based on ICD status during labour. Patients who gave birth with an activated ICD at least once were stratified to the activated ICD group. Patients' files were checked and patients received a questionnaire about childbirth perceptions and treatment preferences. The differences in ordinal data resulting from the questionnaire were calculated using a chi-square or Fisher's exact test. MAIN OUTCOME MEASURES: Primary outcome was inappropriate ICD therapy and occurrence of ventricular arrhythmias requiring treatment. RESULTS: During the 41 childbirths, no inappropriate shocks or ventricular arrhythmias occurred during labour. All patients in the activated ICD group (n = 13) preferred this setting, while 8 of the 13 patients in the deactivated ICD group preferred activation (p = 0.002). Reasons included avoiding hemodynamic monitoring, magnet placement, or labour induction to facilitate technician availability. CONCLUSIONS: This study shows no evidence that labour and birth in women with an activated ICD are unsafe, as there were no ventricular arrhythmias or inappropriate therapy. In addition, most patients prefer an activated ICD during labour.

3.
Circ Arrhythm Electrophysiol ; 16(8): 421-432, 2023 08.
Article En | MEDLINE | ID: mdl-37582163

BACKGROUND: This study assessed safety and feasibility of a novel extravascular implantable cardioverter defibrillator (ICD) lead when inserted anteriorly through a rib space and connected to various commercially available ICD pulse generators (PGs) placed in either a left mid-axillary or left pectoral pocket. Currently available or investigational, extravascular-ICDs include a subcutaneous or subxiphoid lead connected to customized extravascular-ICD PGs. METHODS: This novel extravascular-ICD (AtaCor Medical Inc, San Clemente, CA) employs a unique intercostal implant technique and is designed to function with commercial DF-4 ICD PGs. In this nonrandomized, single-center, acute study, 36 de novo or replacement ICD (transvenous ICD) patients enrolled to receive a concomitant extravascular-ICD lead inserted through an intercostal space along the left parasternal margin. extravascular-ICD leads were connected to DF-4 compatible ICD PGs positioned in either a left mid-axillary or pectoral pocket for acute sensing and defibrillation testing. Defibrillation testing started at 30 Joules (J) and stepped up or down in 5 to 10 joule increments depending on the success and limitations of the generator used. RESULTS: Successful acute defibrillation using ≤35 J was noted in 100% of left mid-axillary PG subjects (n=27, mean 16.3±8.6 J) and 83% of left pectoral PG subjects (n=6, mean 21.0±8.4 J). Furthermore, 24 of 27 (89%) of patients tested with a left, mid-axillary intermuscular PG had successful VF conversion with defibrillation energies at least 10 J below the maximum delivered output of the device. All evaluable episodes (n=93) were automatically sensed, detected, and shocked. No serious device-related intraoperative adverse events were observed. CONCLUSIONS: This first-in-human study documented the safe and reliable placement of a novel extravascular ICD lead with effective sensing and defibrillation of induced ventricular fibrillation using commercial DF-4 ICD PGs.


Defibrillators, Implantable , Humans , Ventricular Fibrillation , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy
4.
Pulm Circ ; 13(2): e12246, 2023 Apr.
Article En | MEDLINE | ID: mdl-37284521

Muscle strength is decreased in adults with pulmonary arterial hypertension (PAH). We aim to investigate muscle strength in children with PAH in relation to a cohort of healthy children, and investigate correlations with disease severity markers. This prospective study included children with PAH aged 4-18 years, who visited the Dutch National Referral Center for Pulmonary Hypertension in Childhood between October 2015 and March 2016. Muscle strength was assessed using handgrip strength and maximum voluntary isometric contractility (MVIC) of four peripheral muscles. Dynamic muscle function was evaluated with the Bruininks-Oseretsky test of motor proficiency (BOT-2). These measurements were compared with those in two cohorts of healthy children and correlated with 6-minute walk distance (6MWD), World Health Organization functional class (WHO-FC), N-terminal pro-brain natriuretic peptide (NT-proBNP), and time since diagnosis. Eighteen children with PAH aged 14.0 [interquartile range: 9.9-16.0] years showed reduced muscle strength. Handgrip strength z-score -2.4 ± 1.2, p < 0.001, total MVIC z-score -2.9 ± 1.2, p < 0.001, and BOT-2 z-score -1.0 ± 0.9, p < 0.001. 6MWD (67 ± 11% predicted) correlated with most muscle measurements (r = 0.49-0.71, p = 0.001). Dynamic muscle function (BOT-2) differed between WHO-FC, whereas handgrip strength and MVIC did not. NT-proBNP and time since diagnosis did not show significant correlations with muscle strength measurements. Muscle strength was significantly reduced in children with PAH and correlated with 6MWD, but not with disease severity markers WHO-FC and NT-pro-BNP. The nature of this reduced muscle strength is yet unclear, but its occurrence in children with seemingly mild or well-controlled PAH supports the concept of PAH being a systemic syndrome involving peripheral skeletal muscles.

5.
Europace ; 25(7)2023 07 04.
Article En | MEDLINE | ID: mdl-37379530

AIMS: After implantation of a subcutaneous implantable cardioverter-defibrillator (S-ICD), a defibrillation test (DFT) is performed to ensure that the device can effectively detect and terminate the induced ventricular arrhythmia. Data on DFT efficacy at generator replacement are scarce with a limited number of patients and conflicting results. This study evaluates conversion efficacy during DFT at elective S-ICD generator replacement in a large cohort from our tertiary centre. METHODS AND RESULTS: Retrospective data of patients who underwent an S-ICD generator replacement for battery depletion with subsequent DFT between February 2015 and June 2022 were collected. Defibrillation test data were collected from both implant and replacement procedures. PRAETORIAN scores at implant were calculated. Defibrillation test was defined unsuccessful when two conversions at 65 J failed. A total of 121 patients were included. The defibrillation test was successful in 95% after the first and 98% after two consecutive tests. This was comparable with success rates at implant, despite a significant rise in shock impedance (73 ± 23 vs. 83 ± 24 Ω, P < 0.001). Both patients with an unsuccessful DFT at 65 J successfully converted with 80 J. CONCLUSION: This study shows a high DFT conversion rate at elective S-ICD generator replacement, which is comparable to conversion rates at implant, despite a rise in shock impedance. Evaluating device position before generator replacement may be recommended to optimize defibrillation success at generator replacement.


Defibrillators, Implantable , Humans , Retrospective Studies , Arrhythmias, Cardiac , Electric Countershock/adverse effects , Electric Impedance , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/therapy
6.
Eur Heart J ; 43(47): 4872-4883, 2022 12 14.
Article En | MEDLINE | ID: mdl-36030464

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) is developed to overcome lead-related complications and systemic infections, inherent to transvenous ICD (TV-ICD) therapy. The PRAETORIAN trial demonstrated that the S-ICD is non-inferior to the TV-ICD with regard to the combined primary endpoint of inappropriate shocks and complications. This prespecified secondary analysis evaluates all complications in the PRAETORIAN trial. METHODS AND RESULTS: The PRAETORIAN trial is an international, multicentre, randomized trial in which 849 patients with an indication for ICD therapy were randomized to receive an S- ICD (N = 426) or TV-ICD (N = 423) and followed for a median of 49 months. Endpoints were device-related complications, lead-related complications, systemic infections, and the need for invasive interventions. Thirty-six device-related complications occurred in 31 patients in the S-ICD group of which bleedings were the most frequent. In the TV-ICD group, 49 complications occurred in 44 patients of which lead dysfunction was most frequent (HR: 0.69; P = 0.11). In both groups, half of all complications were within 30 days after implantation. Lead-related complications and systemic infections occurred significantly less in the S-ICD group compared with the TV-ICD group (P < 0.001, P = 0.03, respectively). Significantly more complications required invasive interventions in the TV-ICD group compared with the S-ICD group (8.3% vs. 4.3%, HR: 0.59; P = 0.047). CONCLUSION: This secondary analysis shows that lead-related complications and systemic infections are more prevalent in the TV-ICD group compared with the S-ICD group. In addition, complications in the TV-ICD group were more severe as they required significantly more invasive interventions. This data contributes to shared decision-making in clinical practice.


Death, Sudden, Cardiac , Defibrillators, Implantable , Humans , Treatment Outcome , Defibrillators, Implantable/adverse effects
7.
Cardiovasc Digit Health J ; 3(6 Suppl): S17-S22, 2022 Dec.
Article En | MEDLINE | ID: mdl-36589758

Background: The Apple Watch (AW) is the first commercially available wearable device with built-in electrocardiogram (ECG) electrodes to perform a single-lead ECG to detect atrial fibrillation (AF). Methods: Patients with AF who were scheduled for electrical cardioversion (ECV) were included in this study. The AW ECGs were obtained pre-ECV and post-ECV. In case of an unclassified recording, the AW ECG was obtained up to 3 times. The 12-lead ECG was used as the reference standard. Sensitivity, specificity, and kappa coefficient were calculated. Results: In total, 74 patients were included. Mean age was 67.1 ± 12.3 years and 20.3% were female. In total 65 AF and 64 sinus rhythm measurements were obtained. The first measurement with the AW showed a sensitivity of 93.5% and specificity of 100% (κ = 0.94). A second measurement resulted in a sensitivity of 94.6% and specificity of 100% (κ = 0.95). A third measurement resulted in a sensitivity of 93% and a specificity of 96.5% (κ = 0.90). Adjudication of unclassified recordings by a physician reduced the total unclassified recordings from 27.9% to 1.6%, but also reduced the accuracy. The kappa coefficient for unclassified single-lead ECGs was 0.58. Conclusion: The single-lead ECG of the AW shows a high accuracy for identifying AF in a clinical setting. Repeating the recording once decreases the total of unclassified recordings; however, a third recording resulted in a lower accuracy and the occurrence of false-positive measurements. Unclassified results of the AW can be reduced by physicians' interpretation of the single-lead ECG; however, the interrater agreement is only moderate.

8.
Atherosclerosis ; 310: 83-87, 2020 10.
Article En | MEDLINE | ID: mdl-32927124

BACKGROUND AND AIMS: Familial hypercholesterolemia (FH) is an inherited disorder associated with increased risk of coronary heart disease as a result of high LDL-cholesterol (LDL-C). The clinical diagnosis can be made with the Dutch Lipid Clinic Network criteria (DLCN criteria). FH is an underdiagnosed disorder, possibly due to false negative LDL-C interpretation during lipid lowering therapy (LLT). We hypothesized that automated health record-based integration of data can provide a signal to facilitate identification of FH patients. METHODS: We included patients with LDL-C ≥6.5 mmol/l after correction for LLT in all patients testing LDL-C in Northwest Clinics, The Netherlands. Patients previously diagnosed with FH were excluded. The primary endpoint was the additional number of patients with DLCN criteria ≥6 points after correction for LLT. Secondary endpoints were the additional number of patients with DLCN criteria ≥6 points after also adding data on patient- and family history, and LDL-C before and after correction for LLT. Analysis was performed in a daily automated routine (HiX ChipSoft). RESULTS: In a total of 41,937 individual LDL-C measurements during 26 weeks, we found 351 patients with LDL-C ≥6.5 mmol/l after automated correction for LLT. FH had previously been diagnosed in 42 patients. In the remaining 309 patients (58.3% female; age: 66 ± 11 yrs (mean ± SD); 85.8% on LLT), the number of patients with DLCN criteria ≥6 points increased from 9 to 95 after correction for LLT, and to 127 after also adding patient and family history. The mean LDL-C before and after correction for LLT was 4.69 ± 1.42 mmol/l and 8.16 ± 1.68 mmol/l, respectively (mean ± SD; p < 0.001). CONCLUSIONS: We conclude that automated medical record-based integration of LDL-C, LLT and patient- and family history can provide a crucial signal to facilitate identification of FH. Whether this signal results in subsequent genetic identification of FH patients and their relatives requires further study.


Hyperlipoproteinemia Type II , Aged , Cholesterol, LDL , Electronic Health Records , Female , Humans , Hyperlipoproteinemia Type II/diagnosis , Hyperlipoproteinemia Type II/epidemiology , Hyperlipoproteinemia Type II/genetics , Male , Middle Aged , Netherlands/epidemiology
9.
Heart ; 103(16): 1244-1249, 2017 08.
Article En | MEDLINE | ID: mdl-28115472

OBJECTIVES: Paediatric pulmonary arterial hypertension (PAH) after neonatal arterial switch operation (ASO) for transposition of the great arteries (TGA) is a clinically recognised entity with an estimated incidence of 0.6%-1.0%. Nevertheless, a clinical characterisation is lacking. We present an international cohort of children with PAH after neonatal ASO for TGA and describe epidemiology and clinical course. METHODS: Data were collected of children with PAH after neonatal ASO (≤6 weeks after birth) for simple TGA without residual shunt defects, identified in four national paediatric PAH networks in Europe and one US referral centre. RESULTS: Twenty-five children were identified between 1989 and 2014. In 17 children (68%), PAH was detected <1 year after ASO. In the remaining children, PAH was detected after median 64 months (IQR 19.5, 94.5). Nineteen children (96%) received PAH-targeted therapies. During follow-up after ASO (median 5.2 years), eight children died, four underwent lung transplantation and two received a Potts shunt. 1-year and 5-year Potts shunt- and transplantation-free survival after ASO was 100% and 73%. From first PAH detection, this was 100% and 58%, respectively, which did not differ between children with early (<1 year after ASO) or late PAH detection. CONCLUSIONS: The occurrence of PAH after ASO for TGA represents a specific association. PAH onset may be early or late after ASO, with similar fatal course from first PAH detection. Mechanisms leading to PAH in this association are unknown, but may include abnormal prenatal pulmonary haemodynamics and/or genetic susceptibility. Routine, lifelong follow-up for children who undergo ASO for TGA should include screening for PAH.


Arterial Switch Operation/adverse effects , Hypertension, Pulmonary/etiology , Transposition of Great Vessels/surgery , Child, Preschool , Europe/epidemiology , Female , Follow-Up Studies , Humans , Hypertension, Pulmonary/epidemiology , Hypertension, Pulmonary/physiopathology , Incidence , Infant , Male , Retrospective Studies , Time Factors , United States/epidemiology
...