Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Cureus ; 16(2): e53930, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38465074

RESUMEN

Gastric antral vascular ectasia (GAVE) is an uncommon cause of upper gastrointestinal (GI) bleeds. Due to the high vascularity of the region, transient bacteremia due to manipulation of the GI tract can very rarely cause the translocation of bacteria. We present a rare case in which endoscopic manipulation to treat GAVE led to native valve infective endocarditis (IE). Our patient had a prior history of GAVE and presented with worsening dizziness and shortness of breath (SOB). After an esophagogastroduodenoscopy (EGD) and subsequent argon plasma coagulation (APC) for active preantral bleeding, the patient was noted to have repeated fevers, a new cardiac murmur, and positive blood cultures for Staphylococcus epidermidis, leading to a diagnosis of native infective endocarditis. With high clinical suspicion and early recognition of a new cardiac murmur, a transesophageal echocardiogram (TEE) was key in identifying vegetation. This case highlights the importance of combining history, a physical exam, and diagnostic lab tests and imaging to identify endocarditis. Management included two months of intravenous (IV) vancomycin and repeat TEE for close monitoring of vegetation improvement.

2.
J Am Coll Cardiol ; 76(18): 2043-2055, 2020 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-33121710

RESUMEN

BACKGROUND: Myocardial injury is frequent among patients hospitalized with coronavirus disease-2019 (COVID-19) and is associated with a poor prognosis. However, the mechanisms of myocardial injury remain unclear and prior studies have not reported cardiovascular imaging data. OBJECTIVES: This study sought to characterize the echocardiographic abnormalities associated with myocardial injury and their prognostic impact in patients with COVID-19. METHODS: We conducted an international, multicenter cohort study including 7 hospitals in New York City and Milan of hospitalized patients with laboratory-confirmed COVID-19 who had undergone transthoracic echocardiographic (TTE) and electrocardiographic evaluation during their index hospitalization. Myocardial injury was defined as any elevation in cardiac troponin at the time of clinical presentation or during the hospitalization. RESULTS: A total of 305 patients were included. Mean age was 63 years and 205 patients (67.2%) were male. Overall, myocardial injury was observed in 190 patients (62.3%). Compared with patients without myocardial injury, those with myocardial injury had more electrocardiographic abnormalities, higher inflammatory biomarkers and an increased prevalence of major echocardiographic abnormalities that included left ventricular wall motion abnormalities, global left ventricular dysfunction, left ventricular diastolic dysfunction grade II or III, right ventricular dysfunction and pericardial effusions. Rates of in-hospital mortality were 5.2%, 18.6%, and 31.7% in patients without myocardial injury, with myocardial injury without TTE abnormalities, and with myocardial injury and TTE abnormalities. Following multivariable adjustment, myocardial injury with TTE abnormalities was associated with higher risk of death but not myocardial injury without TTE abnormalities. CONCLUSIONS: Among patients with COVID-19 who underwent TTE, cardiac structural abnormalities were present in nearly two-thirds of patients with myocardial injury. Myocardial injury was associated with increased in-hospital mortality particularly if echocardiographic abnormalities were present.


Asunto(s)
Infecciones por Coronavirus/diagnóstico por imagen , Corazón/diagnóstico por imagen , Miocardio/patología , Neumonía Viral/diagnóstico por imagen , Disfunción Ventricular/virología , Anciano , Betacoronavirus , Biomarcadores/sangre , COVID-19 , Angiografía Coronaria , Infecciones por Coronavirus/sangre , Infecciones por Coronavirus/complicaciones , Infecciones por Coronavirus/tratamiento farmacológico , Infecciones por Coronavirus/mortalidad , Ecocardiografía , Electrocardiografía , Femenino , Corazón/fisiopatología , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Ciudad de Nueva York/epidemiología , Pandemias , Neumonía Viral/sangre , Neumonía Viral/complicaciones , Neumonía Viral/mortalidad , Estudios Retrospectivos , SARS-CoV-2 , Tratamiento Farmacológico de COVID-19
3.
Echocardiography ; 36(6): 1165-1172, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31148272

RESUMEN

Left ventricular outflow tract obstruction is a serious complication of mitral valve surgery (repair and replacement) and transcatheter mitral valve replacement. An appreciation of the various mechanisms which cause outflow obstruction in these settings is critical to avoiding this complication and to initiating appropriate treatment. This article discusses the mechanisms, pathophysiology, and imaging of left ventricular outflow tract obstruction which can arise following insertion of a variety of mitral valve prosthetics.


Asunto(s)
Ecocardiografía/métodos , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Complicaciones Posoperatorias/fisiopatología
5.
J Invasive Cardiol ; 28(5): 196-201, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27145051

RESUMEN

BACKGROUND: Right heart thrombus in the absence of structural heart disease, atrial fibrillation, or intracardiac catheter is rare. It typically represents a thrombus migrating from the venous system to the lung, known as thrombi-in-transit, and can lead to a life-threatening pulmonary embolism. The optimal therapy for thrombi-in-transit remains controversial. We report our experience using percutaneous removal of right heart thrombus using vacuum aspiration. METHODS: Patients with right atrial mass who were hemodynamically stable and underwent vacuum thombectomy using the AngioVac system (AngioDynamics) at our institution were included in this analysis. Between December 2012 and August 2014, a total of 7 patients (2 men, 5 women) with a mean age of 51.5 years (range, 20-83 years) underwent right atrial thrombectomy. Data during the procedure and follow-up period were collected and analyzed. RESULTS: All patients were hemodynamically stable before the procedure. The procedure was considered successful in 6 patients. All patients survived through hospitalization. No periprocedural bleeding, stroke, or myocardial infarction occurred. One patient developed cardiogenic shock after the procedure that required extracorporeal membrane oxygenation support for <24 hours. There was no recurrent venous thromboembolism at a mean follow-up of 9 months. CONCLUSION: Vacuum-assisted thrombectomy can be a potential treatment option for hemodynamically stable patients with large right-sided intracardiac thrombus who are not surgical candidates.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías/terapia , Trombectomía/métodos , Trombosis/terapia , Adulto , Anciano , Anciano de 80 o más Años , Ecocardiografía , Femenino , Estudios de Seguimiento , Atrios Cardíacos/diagnóstico por imagen , Cardiopatías/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis/diagnóstico , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Vacio , Adulto Joven
6.
J Am Coll Cardiol ; 66(2): 169-83, 2015 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-26160633

RESUMEN

Transcatheter therapies in structural heart disease have evolved tremendously over the past 15 years. Since the introduction of the first balloon-expandable valves for stenotic lesions with implantation in the pulmonic position in 2000, treatment for valvular heart disease in the outflow position has become more refined, with newer-generation devices, alternative techniques, and novel access approaches. Recent efforts into the inflow position and regurgitant lesions, with transcatheter repair and replacement technologies, have expanded our potential to treat a broader, more heterogeneous patient population. The evolution of multimodality imaging has paralleled these developments. Three- and 4-dimensional visualization and concomitant use of novel technologies, such as fusion imaging, have supported technical growth, from pre-procedural planning and intraprocedural guidance, to assessment of acute results and follow-up. A multimodality approach has allowed operators to overcome many limitations of each modality and facilitated integration of a multidisciplinary team for treatment of this complex patient population.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/terapia , Insuficiencia de la Válvula Aórtica/terapia , Cateterismo Cardíaco , Diagnóstico por Imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Humanos , Insuficiencia de la Válvula Mitral/terapia , Insuficiencia de la Válvula Pulmonar/terapia , Insuficiencia de la Válvula Tricúspide/terapia
8.
EuroIntervention ; 10(11): 1336-45, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24800978

RESUMEN

AIMS: Structural deterioration and paravalvular leak (PVL) are complications associated with surgically implanted prosthetic valves, historically requiring reoperation. We present our experience of complete transcatheter repair of a degenerated mitral bioprosthesis. METHODS AND RESULTS: From March 2012 to October 2012, we reviewed consecutive, high-risk surgical patients (n=5) who underwent transcatheter repair of a failed mitral bioprosthesis with severe paravalvular regurgitation (PVR). Manufacturer valve sizes ranged from 27 to 33 mm, regurgitation (n=1), stenosis (n=1), or both (n=3). Percutaneous transapical and transseptal access were achieved with PVL closure performed transapically. An arteriovenous rail was created for transseptal delivery of a Melody valve. All patients had successful PVL closure with no residual PVR. Valve-in-valve (ViV) implantation was successful in four patients. Overall, mean transvalvular mitral gradient was 11.2 mmHg pre-procedure which improved to 5 mmHg post-procedure. Improvement of NYHA Class ≥2 was achieved in all patients (19±3 months). One patient had controlled Melody valve embolisation which required emergent surgical replacement. Inner valve diameter was 26 mm, too large for Melody valve implantation. CONCLUSIONS: Complete transcatheter repair of a degenerated mitral bioprosthesis with PVR can be performed in the high-risk patient. Accurate measurement is necessary prior to intervention, with concern for embolisation among the larger valve sizes (>31 mm).


Asunto(s)
Bioprótesis , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Falla de Prótesis/efectos adversos , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/etiología , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
9.
EuroIntervention ; 10(8): 968-74, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25540082

RESUMEN

AIMS: Transcatheter techniques can theoretically be applied to the treatment of para-annular ring (PAR) leaks. Little is known about their potential application and resultant complications in such cases. We describe the first-in-man percutaneous transapical-transseptal Melody valve-in-ring (ViR) implantation after a complication from percutaneous PAR leak closure. METHODS AND RESULTS: A 49-year-old woman, at high operative risk, presented with congestive heart failure secondary to severe para-ring/extravalvular regurgitation two months after bypass surgery and mitral ring annuloplasty. Successful percutaneous closure of the leak was performed using an AMPLATZER Vascular Plug IV. One month later, she developed haemolysis with severe PAR regurgitation, through and around the device. After device retrieval and placement of an AMPLATZER Muscular VSD occluder, the patient developed severe intravalvular regurgitation. Completely percutaneous, transseptal delivery of a Melody ViR was performed over a transapical-transseptal, arteriovenous rail. Echocardiography revealed trivial residual regurgitation through the implanted valve with mild transvalvular gradients. CONCLUSIONS: Percutaneous closure of mitral PAR leaks after ring annuloplasty in the high-risk patient is feasible (proof-of-concept), particularly when the leak is para-ring/extravalvular. Potential complications include severe intravalvular mitral regurgitation caused by disruption of the mitral apparatus and/or ring deformation during device deployment, which can be successfully treated via percutaneous transapical-transseptal ViR implantation.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Falla de Prótesis , Dispositivo Oclusor Septal , Femenino , Humanos , Persona de Mediana Edad
10.
Curr Cardiol Rep ; 16(3): 456, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24473966

RESUMEN

Left ventricular pseudoaneurysm and ventricular septal defect are rare but devastating complications of myocardial infarction. With medical treatment alone, the majority of patients will die from these complications. Until recently, the recommended treatment was surgical closure. These surgeries carried extreme risk due to abnormal hemodynamics, necrotic substrates and the comorbidities of these patients. Recently, trans-catheter closure was shown to be an acceptable alternative to open surgical intervention. 3D echocardiography identifies the location, size, and shape of the defect and can assess, guide, and follow up the closure procedure.


Asunto(s)
Aneurisma Falso/cirugía , Defectos del Tabique Interventricular/cirugía , Infarto del Miocardio/complicaciones , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Cateterismo Cardíaco/métodos , Ecocardiografía Tridimensional/métodos , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/etiología , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Dispositivo Oclusor Septal , Ultrasonografía Intervencional/métodos
11.
JACC Cardiovasc Imaging ; 7(2): 169-77, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24412189

RESUMEN

OBJECTIVES: The aim of this proof-of-principle study is to validate the accuracy of fusion imaging for percutaneous transapical access (TA). BACKGROUND: Structural heart disease interventions, including TA, are commonly obtained under fluoroscopic guidance, which lacks important spatial information. Computed tomographic angiography (CTA)-fluoroscopy fusion imaging can provide the 3-dimensional information necessary for improved accuracy in planning and guidance of these interventions. METHODS: Twenty consecutive patients scheduled for percutaneous left ventricular puncture and device closure using CTA-fluoroscopy fusion guidance were prospectively recruited. The HeartNavigator software (Philips Healthcare, Best, the Netherlands) was used to landmark the left ventricular epicardium for TA (planned puncture site [PPS]). The PPS landmark was compared with the position of the TA closure device on post-procedure CTA (actual puncture site). The distance between the PPS and actual puncture site was calculated from 2 fixed reference points (left main ostium and mitral prosthesis center) in 3 planes (x, y, and z). The distance from the left anterior descending artery at the same z-plane was also assessed. TA-related complications associated with fusion imaging were recorded. RESULTS: The median (interquartile range [IQR]) TA distance difference between the PPS and actual puncture site from the referenced left main ostium and mitral prosthesis center was 5.00 mm (IQR: 1.98 to 12.64 mm) and 3.27 mm (IQR: 1.88 to 11.24 mm) in the x-plane, 4.48 mm (IQR: 1.98 to 13.08 mm) and 4.00 mm (IQR: 1.62 to 11.86 mm) in the y-plane, and 5.57 mm (IQR: 3.89 to 13.62 mm) and 4.96 mm (IQR: 1.92 to 11.76 mm) in the z-plane. The mean TA distance to the left anterior descending artery was 15.5 ± 7.8 mm and 22.7 ± 13.7 mm in the x- and y-planes. No TA-related complications were identified, including evidence of coronary artery laceration. CONCLUSIONS: With the use of CTA-fluoroscopy fusion imaging to guide TA, the actual puncture site can be approximated near the PPS. Moreover, fusion imaging can help maintain an adequate access distance from the left anterior descending artery, thereby, potentially reducing TA-related complications.


Asunto(s)
Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Cardiopatías/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Tomografía Computarizada Multidetector , Imagen Multimodal/métodos , Radiografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Femenino , Fluoroscopía , Cardiopatías/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Punciones , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados
12.
Curr Cardiol Rep ; 15(3): 338, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23338720

RESUMEN

Over the past decade, catheter based treatments of an increasing variety of cardiac diseases have expanded dramatically. These advancements became available through new developments and improvements in available devices, as well as increasing expertise of operators. However, arguably it is the innovation and progress in imaging techniques, and in particular in echocardiography, that allowed for such a surge in available percutaneous procedures. In this paper, current echocardiographic techniques, imaging protocols and recommendations will be reviewed and clinical examples will be shown to illustrate the use and importance of echocardiographic imaging in catheter based procedures for structural heart disease.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Ablación por Catéter/métodos , Ecocardiografía Tridimensional/métodos , Cardiopatías/cirugía , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Atención Perioperativa/métodos
13.
Eur Heart J ; 34(9): 638-49, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23117162

RESUMEN

Paravalvular leak (PVL) is an uncommon yet serious complication associated with surgical prosthetic valve implantation. Paravalvular leak can have significant clinical consequence such as congestive heart failure, haemolytic anaemia, and infective endocarditis. Recently, transcatheter therapy has been applied to the treatment of this disorder with reasonable procedural and clinical success. This review discusses the current state of PVLs, the utilization of multi-modality imaging in their diagnosis and treatment, and the available therapeutic options. Further aim of this review is to examine transcatheter therapy of PVLs including the principles, outcomes, and procedural-related complications.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis/efectos adversos , Anemia Hemolítica/diagnóstico , Anemia Hemolítica/etiología , Anemia Hemolítica/cirugía , Angiografía/métodos , Biomarcadores/metabolismo , Ecocardiografía/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Tomografía Computarizada por Rayos X/métodos
14.
J Am Soc Echocardiogr ; 25(9): 969-74, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22795199

RESUMEN

BACKGROUND: Assessing left ventricular function is a common indication for echocardiography. It generally requires expert echocardiographer estimation and is somewhat subjective and prone to reader discordance. Mitral annular plane systolic excursion (MAPSE) has been suggested as a surrogate measurement for left ventricular function. The aim of this study was to examine the accuracy of MAPSE for predicting left ventricular ejection fraction (EF) on the basis of a large cohort of consecutive echocardiograms. METHODS: The study design was a retrospective analysis of 600 two-dimensional echocardiographic studies performed in a single laboratory. MAPSE measurement was performed by an untrained observer and compared with the EF as determined by an expert echocardiographer. The first 300 studies served as a calibration cohort to establish an algorithm for predicting EF on the basis of MAPSE measurement. The following 300 studies served as a verification cohort to test the accuracy of the established algorithm. RESULTS: Using the first 300 studies, an algorithm was developed to predict EF. Cutoff values for normal EF (≥11 mm for women and ≥13 mm for men) and severely reduced EF (<6 mm for men and women) were identified. For the intermediate-range MAPSE values, a gender-specific regression equation was calculated to generate a predicted EF. Using this algorithm, predicted EFs were determined for the 300 patients in the verification cohort. By comparing the predicted EF and the expert-reported EF, positive and negative predictive values, sensitivity (73%-92%), specificity (81%-100%), and accuracy (82%-86%) of MAPSE for predicting EF were calculated. CONCLUSIONS: MAPSE measurement by an untrained observer was found to be a highly accurate predictor of EF.


Asunto(s)
Algoritmos , Ecocardiografía/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Análisis de Regresión , Estudios Retrospectivos , Sensibilidad y Especificidad , Volumen Sistólico/fisiología , Sístole/fisiología , Disfunción Ventricular Izquierda/fisiopatología
17.
Eur Heart J Cardiovasc Imaging ; 13(2): 132-8, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21903725

RESUMEN

Atrial fibrillation is a common, clinically significant arrhythmic disorder that results in increased risk of morbidity and mortality in affected patients. Atrial fibrillation is more prevalent among men compared with women and the risk for developing atrial fibrillation increases with advancing age. Ischaemic stroke is the most common clinical manifestation of embolic events from atrial fibrillation. While anticoagulation treatment is the preferred treatment, unfortunately, many patients have contraindications for anticoagulation treatment making this option unavailable to them. Previous data have shown that most thrombi that form in association with non-valvular atrial fibrillation occur in the left atrial appendage (LAA). It has been suggested that isolating the LAA from the body of the left atrium might reduce the risk of embolic events and that LAA obliteration may be a treatment option for patients with atrial fibrillation who are not candidates for anticoagulation treatment. Several procedures have been developed for isolation of the LAA, including surgical procedures as well as catheter-based ones. In this paper, we will review the currently available techniques, emphasizing the catheter-based ones. We will examine the increasing role of real-time three-dimensional transoesophageal echocardiography for appropriate screening and patient selection for these procedures, intra-procedural guidance, and follow-up care.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Fibrilación Atrial/epidemiología , Estudios de Seguimiento , Humanos , Tamizaje Masivo , Selección de Paciente , Politetrafluoroetileno , Prevalencia , Prótesis e Implantes , Diseño de Prótesis , Factores de Riesgo , Distribución por Sexo , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
J Am Soc Echocardiogr ; 24(6): 611-7, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21435839

RESUMEN

BACKGROUND: Catheter-based mitral valve clip repair (CBMCR) is feasible for selected patients with mitral regurgitation (MR). Two-dimensional (2D) transesophageal echocardiography (TEE) is the standard modality for evaluating MR and procedural guidance. Recently, real-time three-dimensional TEE became available. The aim of this study was to evaluate the value of combined 2D and three-dimensional TEE for CBMCR. In evaluating MR for CBMCR, the confidence of interpretation of 2D TEE was compared with that of combined imaging for the localization of major valve pathology. In patients who underwent CBMCR, the outcomes and the duration of CBMCR were compared. METHODS: In this retrospective study, MR evaluation was performed by 2D TEE alone and by combined imaging in 80 and 57 patients, respectively. CBMCR was guided by 2D TEE alone in 20 patients and by combined imaging in 39 patients. RESULTS: Examination by combined imaging allowed en face visualization of mitral valve anatomy and MR jet origin. The confidence of interpretation by combined imaging was higher than for 2D TEE (1.1 ± 0.3 vs 1.8 ± 0.7, P < .001).The guidance of CBMCR by combined imaging facilitated alignment of the catheter trajectory, clip positioning, and orientation of clip arms. The procedural success and final MR grade were not different between the two study groups. However, the procedural time of CBMCR using combined imaging compared with that using 2D TEE guidance alone was shorter (241 ± 58 vs 201 ± 68 min, P = .035). CONCLUSIONS: The use of combined imaging compared with 2D TEE alone appears to enhance the confidence of interpretation concerning mitral pathology and catheter-clip system location and may also reduce CBMCR time.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Sistema de Registros , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA