J Appl Clin Med Phys ; : e14386, 2024 May 13.
Article En | MEDLINE | ID: mdl-38739330

PURPOSE: Photon counting CT (PCCT) holds promise for mitigating metal artifacts and can produce virtual mono-energetic images (VMI), while maintaining temporal resolution, making it a valuable tool for characterizing the heart. This study aimed to evaluate and optimize PCCT for cardiac imaging in patients during left ventricular assistance device (LVAD) therapy by conducting an in-depth objective assessment of metal artifacts and visual grading. METHODS: Various scan and reconstruction settings were tested on a phantom and further evaluated on a patient acquisition to identify the optimal protocol settings. The phantom comprised an empty thoracic cavity, supplemented with heart and lungs from a cadaveric lamb. The heart was implanted with an LVAD (HeartMate 3) and iodine contrast. Scans were performed on a PCCT (NAEOTOM Alpha, Siemens Healthcare). Metal artifacts were assessed by three objective methods: Hounsfield units (HU)/SD measurements (DiffHU and SDARTIFACT), Fourier analysis (AmplitudeLowFreq), and depicted LVAD volume in the images (BloomVol). Radiologists graded metal artifacts and the diagnostic interpretability in the LVAD lumen, cardiac tissue, lung tissue, and spinal cord using a 5-point rating scale. Regression and correlation analysis were conducted to determine the assessment method most closely associated with acquisition and reconstruction parameters, as well as the objective method demonstrating the highest correlation with visual grading. RESULTS: Due to blooming artifacts, the LVAD volume fluctuated between 27.0 and 92.7 cm3. This variance was primarily influenced by kVp, kernel, keV, and iMAR (R2 = 0.989). Radiologists favored pacemaker iMAR, 3 mm slice thickness, and T3D keV and kernel Bv56f for minimal metal artifacts in cardiac tissue assessment, and 110 keV and Qr40f for lung tissue interpretation. The model adequacy for DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was 0.28, 0.76, 0.29, and 0.99 respectively for phantom data, and 0.95, 0.98, 1.00, and 0.99 for in-vivo data. For in-vivo data, the correlation between visual grading (VGSUM) and DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was -0.16, -0.01, -0.48, and -0.40 respectively. CONCLUSION: We found that optimal scan settings for LVAD imaging involved using 120 kVp and IQ level 80. Employing T3D with pacemaker iMAR, the sharpest allowed vascular kernel (Bv56f), and VMI at 110 keV with kernel Qr40 yields images suitable for cardiac imaging during LVAD-therapy. Volumetric measurements of the LVAD for determination of the extent of blooming artifacts was shown to be the best objective method to assess metal artifacts.

2.
Heart ; 2024 Apr 05.
Article En | MEDLINE | ID: mdl-38580434

BACKGROUND: Elevated heart rate (HR) predicts cardiovascular disease and mortality, but there are no established normal limits for ambulatory HR. We used data from the Swedish CArdioPulmonary Imaging Study to determine reference ranges for ambulatory HR in a middle-aged population. We also studied clinical correlates of ambulatory HR. METHODS: A 24-hour ECG was registered in 5809 atrial fibrillation-free individuals, aged 50-65 years. A healthy subset (n=3942) was used to establish reference values (excluding persons with beta-blockers, cardiovascular disease, hypertension, heart failure, anaemia, diabetes, sleep apnoea or chronic obstructive pulmonary disease).Minimum HR was defined as the lowest 1-minute HR. Reference ranges are reported as means±SDs and 2.5th-97.5th percentiles. Clinical correlates of ambulatory HR were analysed with multivariable linear regression. RESULTS: The average mean and minimum HRs were 73±9 and 48±7 beats per minute (bpm) in men and 76±8 and 51±7 bpm in women; the reference range for mean ambulatory HR was 57-90 bpm in men and 61-92 bpm in women. Average daytime and night-time HRs are also reported. Clinical correlates, including age, sex, height, body mass index, physical activity, smoking, alcohol intake, diabetes, hypertension, haemoglobin level, use of beta-blockers, estimated glomerular filtration rate, per cent of predicted forced expiratory volume in 1 s and coronary artery calcium score, explained <15% of the interindividual differences in HR. CONCLUSION: Ambulatory HR varies widely in healthy middle-aged individuals, a finding with relevance for the management of patients with a perception of tachycardia. Differences in ambulatory HR between individuals are largely independent of common clinical correlates.

3.
Eur J Radiol ; 173: 111383, 2024 Apr.
Article En | MEDLINE | ID: mdl-38377892

PURPOSE: Scaphoid fractures in patients and assessment of healing using PCD-CT have, as far as we know, not yet been studied. Therefore, the aim was to compare photon counting detector CT (PCD-CT) with energy integrating detector CT (EID-CT) in terms of fracture visibility and evaluation of fracture healing. METHOD: Eight patients with scaphoid fracture were examined with EID-CT and PCD-CT within the first week post-trauma, and with additional scans at 4, 6 and 8 weeks. Our clinical protocol for wrist examination with EID-CT was used (CTDIvol 3.1 ± 0.1 mGy, UHR kernel Ur77). For PCD-CT matched radiation dose, reconstruction kernel Br89. Quantitative analyses of noise, CNR, trabecular and cortical sharpness, and bone volume fraction were conducted. Five radiologists evaluated the images for fracture visibility, fracture gap consolidation and image quality, and rated their confidence in the diagnosis. RESULTS: The trabecular and cortical sharpness were superior in images obtained with PCD-CT compared with EID-CT. A successive reduction in trabecular bone volume fraction during the immobilized periods was found with both systems. Despite higher noise and lower CNR with PCD-CT, radiologists rated the image quality of PCD-CT as superior. The visibility of the fracture line within 1-week post-trauma was rated higher with PCD-CT as was diagnostic confidence, but the subsequent assessments of fracture gap consolidation during healing process and the confidence in diagnosis were found equivalent between both systems. CONCLUSION: PCD-CT offers superior visibility of bone microstructure compared with EID-CT. The evaluation of fracture healing and confidence in diagnosis were rated equally with both systems, but the radiologists found primary fracture visibility and overall image quality superior with PCD-CT.


Fractures, Bone , Scaphoid Bone , Humans , Fractures, Bone/diagnostic imaging , Follow-Up Studies , Scaphoid Bone/diagnostic imaging , Tomography, X-Ray Computed/methods , Photons , Phantoms, Imaging
4.
Eur J Epidemiol ; 39(1): 35-49, 2024 Jan.
Article En | MEDLINE | ID: mdl-38165527

Reduced lung function is associated with cardiovascular mortality, but the relationships with atherosclerosis are unclear. The population-based Swedish CArdioPulmonary BioImage study measured lung function, emphysema, coronary CT angiography, coronary calcium, carotid plaques and ankle-brachial index in 29,593 men and women aged 50-64 years. The results were confirmed using 2-sample Mendelian randomization. Lower lung function and emphysema were associated with more atherosclerosis, but these relationships were attenuated after adjustment for cardiovascular risk factors. Lung function was not associated with coronary atherosclerosis in 14,524 never-smokers. No potentially causal effect of lung function on atherosclerosis, or vice versa, was found in the 2-sample Mendelian randomization analysis. Here we show that reduced lung function and atherosclerosis are correlated in the population, but probably not causally related. Assessing lung function in addition to conventional cardiovascular risk factors to gauge risk of subclinical atherosclerosis is probably not meaningful, but low lung function found by chance should alert for atherosclerosis.


Atherosclerosis , Carotid Artery Diseases , Coronary Artery Disease , Emphysema , Male , Humans , Female , Risk Factors , Carotid Artery Diseases/epidemiology , Atherosclerosis/epidemiology , Coronary Artery Disease/epidemiology , Lung
5.
Am J Physiol Heart Circ Physiol ; 326(3): H511-H521, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38133621

Left atrial (LA) blood flow plays an important role in diseases such as atrial fibrillation (AF) and atrial cardiomyopathy since alterations in the blood flow might lead to thrombus formation and stroke. Using traditional techniques, such as echocardiography, atrial flow velocities can be measured at the pulmonary veins and the mitral valve, but a comprehensive understanding of the three-dimensional atrial flow field is missing. Previously, ventricular flow has been analyzed using flow component analysis, revealing new insights into ventricular flow and function. Thus, the aim of this project was to develop a comprehensive flow component analysis method for the LA and explore its utility in 21 patients with paroxysmal atrial fibrillation compared with a control group of 8 participants. The flow field was derived from time-resolved CT acquired during sinus rhythm using computational fluid dynamics. Flow components were computed from particle tracking. We identified six atrial flow components: conduit, reservoir, delayed ejection, retained inflow, residual volume, and pulmonary vein backflow. It was shown that conduit flow, defined as blood entering and leaving the LA within the same diastolic phase, exists in most subjects. Although the volume of conduit and reservoir is similar in patients with paroxysmal AF in sinus rhythm and controls, the volume of the other components is increased in paroxysmal AF. Comprehensive quantification of LA flow using flow component analysis makes atrial blood flow quantifiable, thus facilitating investigation of mechanisms underlying atrial dysfunction and can increase understanding of atrial blood flow in disease progression and stroke risk.NEW & NOTEWORTHY We developed a new comprehensive approach to atrial blood component analysis that includes both conduit flow and residual volume and compared the flow components of atrial fibrillation (AF) patients in sinus rhythm with controls. Conduit and reservoir flow were similar between the groups, whereas components with longer residence time in the left atrium were increased in the AF group. This could add to the pathophysiological understanding of atrial diseases and possibly clinical management.


Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/diagnostic imaging , Heart Atria/diagnostic imaging , Echocardiography , Hemodynamics
6.
BMJ Open ; 13(11): e073380, 2023 11 23.
Article En | MEDLINE | ID: mdl-37996228

OBJECTIVES: The aim included investigation of the associations between sedentary (SED), low-intensity physical activity (LIPA), moderate-to-vigorous intensity PA (MVPA) and the prevalence of subclinical atherosclerosis in both coronaries and carotids and the estimated difference in prevalence by theoretical reallocation of time in different PA behaviours. DESIGN: Cross-sectional. SETTING: Multisite study at university hospitals. PARTICIPANTS: A total of 22 670 participants without cardiovascular disease (51% women, 57.4 years, SD 4.3) from the population-based Swedish CArdioPulmonary bioImage study were included. SED, LIPA and MVPA were assessed by hip-worn accelerometer. PRIMARY AND SECONDARY OUTCOMES: Any and significant subclinical coronary atherosclerosis (CA), Coronary Artery Calcium Score (CACS) and carotid atherosclerosis (CarA) were derived from imaging data from coronary CT angiography and carotid ultrasound. RESULTS: High daily SED (>70% ≈10.5 hours/day) associated with a higher OR 1.44 (95% CI 1.09 to 1.91), for significant CA, and with lower OR 0.77 (95% CI 0.63 to 0.95), for significant CarA. High LIPA (>55% ≈8 hours/day) associated with lower OR for significant CA 0.70 (95% CI 0.51 to 0.96), and CACS, 0.71 (95% CI 0.51 to 0.97), but with higher OR for CarA 1.41 (95% CI 1.12 to 1.76). MVPA above reference level, >2% ≈20 min/day, associated with lower OR for significant CA (OR range 0.61-0.67), CACS (OR range 0.71-0.75) and CarA (OR range 0.72-0.79). Theoretical replacement of 30 min of SED into an equal amount of MVPA associated with lower OR for significant CA, especially in participants with high SED 0.84 (95% CI 0.76 to 0.96) or low MVPA 0.51 (0.36 to 0.73). CONCLUSIONS: MVPA was associated with a lower risk for significant atherosclerosis in both coronaries and carotids, while the association varied in strength and direction for SED and LIPA, respectively. If causal, clinical implications include avoiding high levels of daily SED and low levels of MVPA to reduce the risk of developing significant subclinical atherosclerosis.


Atherosclerosis , Carotid Artery Diseases , Coronary Artery Disease , Female , Humans , Male , Middle Aged , Accelerometry/methods , Carotid Artery Diseases/diagnostic imaging , Carotid Artery Diseases/epidemiology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Cross-Sectional Studies , Exercise
7.
Eur J Radiol ; 168: 111110, 2023 Nov.
Article En | MEDLINE | ID: mdl-37788519

PURPOSE: To find the optimal imaging parameters for a photon-counting detector CT (PCD-CT) and to compare it to an energy-integrating detector CT (EID-CT) in terms of image quality and metal artefact severity using a metal-containing bovine knee specimen. METHODS: A bovine knee with a stainless-steel plate and screws was imaged in a whole-body research PCD-CT at 120 kV and 140 kV and in an EID dual-source CT (DSCT) at Sn150 kV and 80/Sn150 kV. PCD-CT virtual monoenergetic 72 and 150 keV images and EID-CT images processed with and without metal artefact reduction algorithms (iMAR) were compared. Four radiologists rated the visualisation of bony structures and metal artefact severity. The Friedman test and Wilcoxon signed-rank test with Bonferroni's correction were used. P-values of ≤ 0.0001 were considered statistically significant. Distributions of HU values of regions of interest (ROIs) in artefact-affected areas were analysed. RESULTS: PCD-CT 140 kV 150 keV images received the highest scores and were significantly better than EID-CT Sn150 kV images. PCD-CT 72 keV images were rated significantly lower than all the others. HU-value variation was larger in the 120 kV and the 72 keV images. The ROI analysis revealed no large difference between scanners regarding artefact severity. CONCLUSION: PCD-CT 140 kV 150 keV images of a metal-containing bovine knee specimen provided the best image quality. They were superior to, or as good as, the best EID-CT images; even without the presumed advantage of tin filter and metal artefact reduction algorithms. PCD-CT is a promising method for reducing metal artefacts.


Metals , Tomography, X-Ray Computed , Humans , Cattle , Animals , Tomography, X-Ray Computed/methods , Algorithms , Phantoms, Imaging , Image Processing, Computer-Assisted/methods
9.
Cardiovasc Diabetol ; 22(1): 261, 2023 09 27.
Article En | MEDLINE | ID: mdl-37759237

BACKGROUND: Patients with type 2 diabetes have an increased risk of death and cardiovascular events and people with diabetes or prediabetes have been found to have increased atherosclerotic burden in the coronary and carotid arteries. This study will estimate the cross-sectional prevalence of atherosclerosis in the coronary and carotid arteries in individuals with prediabetes and diabetes, compared with normoglycaemic individuals in a large population-based cohort. METHODS: The 30,154 study participants, 50-64 years, were categorized according to their fasting glycaemic status or self-reported data as normoglycaemic, prediabetes, and previously undetected or known diabetes. Prevalence of affected coronary artery segments, severity of stenosis and coronary artery calcium score (CACS) were determined by coronary computed tomography angiography. Total atherosclerotic burden was assessed in the 11 clinically most relevant segments using the Segment Involvement Score and as the presence of any coronary atherosclerosis. The presence of atherosclerotic plaque in the carotid arteries was determined by ultrasound examination. RESULTS: Study participants with prediabetes (n = 4804, 16.0%) or diabetes (n = 2282, 7.6%) had greater coronary artery plaque burden, more coronary stenosis and higher CACS than normoglycaemic participants (all, p < 0.01). Among male participants with diabetes 35.3% had CACS ≥ 100 compared to 16.1% among normoglycaemic participants. For women, the corresponding figures were 8.9% vs 6.1%. The prevalence of atherosclerosis in the coronary arteries was higher in participants with previously undetected diabetes than prediabetes, but lower than in patients with known diabetes. The prevalence of any plaque in the carotid arteries was higher in participants with prediabetes or diabetes than in normoglycaemic participants. CONCLUSIONS: In this large population-based cohort of currently asymptomatic people, the atherosclerotic burden in the coronary and carotid arteries increased with increasing degree of dysglycaemia. The finding that the atherosclerotic burden in the coronary arteries in the undetected diabetes category was midway between the prediabetes category and patients with known diabetes may have implications for screening strategies and tailored prevention interventions for people with dysglycaemia in the future.


Atherosclerosis , Diabetes Mellitus, Type 2 , Plaque, Atherosclerotic , Prediabetic State , Humans , Female , Male , Prediabetic State/diagnosis , Prediabetic State/epidemiology , Diabetes Mellitus, Type 2/diagnosis , Diabetes Mellitus, Type 2/epidemiology , Cross-Sectional Studies , Prevalence , Sweden/epidemiology
10.
Acta Orthop ; 94: 484-489, 2023 Sep 26.
Article En | MEDLINE | ID: mdl-37753559

BACKGROUND AND PURPOSE: Periprosthetic joint infection (PJI) is a feared complication of arthroplasty surgery. There is controversy as to whether PJI also correlates with increased mortality. Our aim was to investigate in a nationwide cohort if PJI is an independent risk factor for dying. PATIENTS AND METHODS: We performed a retrospective cohort study based on data from the Swedish Hip Arthroplasty Register (SHAR). All patients with a revision THA performed between 1998 and 2017 were included. The outcome is mortality; exposure is PJI according to SHAR. The control group was study participants who underwent aseptic revision. Confounders were age, sex, diagnosis, and comorbidity according to the Elixhauser index. The outcome was analyzed with a Cox proportional hazards model. RESULTS: 4,943 PJI revisions and 12,529 non-infected revisions were included in the analysis. The median follow-up time was 4.1 years. In the PJI group, 1,972 patients died and in the control group, 4,512. The incidence rate ratio was 1.19 (95% confidence interval [CI] 1.13-1.25), the crude hazard ratio (HR) 1.19 (CI 1.13-1.25), and the adjusted HR 1.05 (CI 0.99-1.12) for the exposed versus the unexposed group. The strongest confounder was comorbidity. CONCLUSION: The increased mortality risk after revision due to PJI is mainly caused by the comorbidity of the patient, rather than by the infection itself.

11.
Acta Radiol ; 64(11): 2957-2966, 2023 Nov.
Article En | MEDLINE | ID: mdl-37735891

BACKGROUND: As guidelines endorse the use of computed tomography (CT) for examining coronary artery disease (CAD), it is important to compare the advantages and disadvantages of the novel photon counting detector CT (PCD-CT) technology with the established energy integrating detector CT (EID-CT). PURPOSE: To compare the image quality of coronary computed tomography angiography (CCTA) and the Agatston scores (AS) derived from EID-CT and PCD-CT. MATERIAL AND METHODS: In this prospective observational study, 28 patients underwent clinical calcium score and CCTA scans on an EID-CT and a PCD-CT scanner. CCTA images were qualitatively analyzed by five observers using visual grading characteristics. The correlation and agreement of the AS were assessed using Spearman's rank correlation and Bland-Altman plots. RESULTS: This qualitative analyses demonstrated a high fraction of "good" or "excellent" ratings for the image criteria in both CT systems. The sharpness of the distal lumen and image quality regarding motion artifacts were rated significantly higher for EID-CT (P < 0.05). However, the sharpness of coronary calcification was rated significantly higher for PCD-CT (P < 0.05). Spearman's rank correlation and Bland-Altman plots showed good correlation (P = 0.95) and agreement regarding the AS between EID-CT and PCD-CT. CONCLUSION: Both CT systems exhibited high CCTA image quality. The sharpness of calcifications was rated significantly higher for PCD-CT. A good correlation was observed between the AS derived from the two systems.


Calcinosis , Coronary Artery Disease , Humans , Computed Tomography Angiography/methods , Prospective Studies , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Coronary Artery Disease/diagnostic imaging
12.
Heart Rhythm O2 ; 4(8): 500-505, 2023 Aug.
Article En | MEDLINE | ID: mdl-37645265

Background: Ventricular tachycardia (VT) occurs intermittently, unpredictably, and has potentially lethal consequences. Objective: Our aim was to derive a risk prediction model for VT episodes ≥10 beats detected on 30-day mobile cardiac telemetry based on the first 24 hours of the recording. Methods: We included patients who were monitored for 2 to 30 days in the United States using full-disclosure mobile cardiac telemetry, without any VT episode ≥10 beats on the first full recording day. An elastic net prediction model was derived for the outcome of VT ≥10 beats on monitoring days 2 to 30. Potential predictors included age, sex, and electrocardiographic data from the first 24 hours: heart rate; premature atrial and ventricular complexes occurring as singlets, couplets, triplets, and runs; and the fastest rate for each event. The population was randomly split into training (70%) and testing (30%) samples. Results: In a population of 19,781 patients (mean age 65.3 ± 17.1 years, 43.5% men), with a median recording time of 18.6 ± 9.6 days, 1510 patients had at least 1 VT ≥10 beats. The prediction model had good discrimination in the testing sample (area under the receiver-operating characteristic curve 0.7584, 95% confidence interval 0.7340-0.7829). A model excluding age and sex had an equally good discrimination (area under the receiver-operating characteristic curve 0.7579, 95% confidence interval 0.7332-0.7825). In the top quintile of the score, more than 1 in 5 patients had a VT ≥10 beats, while the bottom quintile had a 98.2% negative predictive value. Conclusion: Our model can predict risk of VT ≥10 beats in the near term using variables derived from 24-hour electrocardiography, and could be used to triage patients to extended monitoring.

13.
Front Cardiovasc Med ; 10: 1219021, 2023.
Article En | MEDLINE | ID: mdl-37649669

Introduction: Atrial fibrillation (AF) is associated with an increased risk of stroke, often caused by thrombi that form in the left atrium (LA), and especially in the left atrial appendage (LAA). The underlying mechanism is not fully understood but is thought to be related to stagnant blood flow, which might be present despite sinus rhythm. However, measuring blood flow and stasis in the LAA is challenging due to its small size and low velocities. We aimed to compare the blood flow and stasis in the left atrium of paroxysmal AF patients with controls using computational fluid dynamics (CFD) simulations. Methods: The CFD simulations were based on time-resolved computed tomography including the patient-specific cardiac motion. The pipeline allowed for analysis of 21 patients with paroxysmal AF and 8 controls. Stasis was estimated by computing the blood residence time. Results and Discussion: Residence time was elevated in the AF group (p < 0.001). Linear regression analysis revealed that stasis was strongest associated with LA ejection ratio (p < 0.001, R2 = 0.68) and the ratio of LA volume and left ventricular stroke volume (p < 0.001, R2 = 0.81). Stroke risk due to LA thrombi could already be elevated in AF patients during sinus rhythm. In the future, patient specific CFD simulations may add to the assessment of this risk and support diagnosis and treatment.

14.
Nephrol Dial Transplant ; 38(12): 2826-2834, 2023 Nov 30.
Article En | MEDLINE | ID: mdl-37349951

BACKGROUND: Immunoglobulin A nephropathy (IgAN) frequently leads to kidney failure. The urinary proteomics-based classifier IgAN237 may predict disease progression at the time of kidney biopsy. We studied whether IgAN237 also predicts progression later in the course of IgAN. METHODS: Urine from patients with biopsy-proven IgAN was analyzed using capillary electrophoresis-mass spectrometry at baseline (IgAN237-1, n = 103) and at follow-up (IgAN237-2, n = 89). Patients were categorized as "non-progressors" (IgAN237 ≤0.38) and "progressors" (IgAN237 >0.38). Estimated glomerular filtration rate (eGFR) and urinary albumin-creatinine ratio slopes were calculated. RESULTS: Median age at biopsy was 44 years, interval between biopsy and IgAN237-1 was 65 months and interval between IgAN237-1 and IgAN237-2 was 258 days (interquartile range 71-531). IgAN237-1 and IgAN237-2 values did not differ significantly and were correlated (rho = 0.44, P < .001). Twenty-eight percent and 26% of patients were progressors based on IgAN237-1 and IgAN237-2, respectively. IgAN237 inversely correlated with chronic eGFR slopes (rho = -0.278, P = .02 for score-1; rho = -0.409, P = .002 for score-2) and with ±180 days eGFR slopes (rho = -0.31, P = .009 and rho = -0.439, P = .001, respectively). The ±180 days eGFR slopes were worse for progressors than for non-progressors (median -5.98 versus -1.22 mL/min/1.73 m2 per year for IgAN237-1, P < .001; -3.02 vs 1.08 mL/min/1.73 m2 per year for IgAN237-2, P = .0047). In multiple regression analysis baseline progressor/non-progressor according to IgAN237 was an independent predictor of eGFR180days-slope (P = .001). CONCLUSION: The urinary IgAN237 classifier represents a risk stratification tool in IgAN also later in the course of the dynamic disease. It may guide patient management in an individualized manner.


Glomerulonephritis, IGA , Humans , Adult , Glomerulonephritis, IGA/pathology , Prognosis , Proteomics , Disease Progression , Biomarkers/urine , Glomerular Filtration Rate
15.
IEEE Trans Biomed Eng ; 70(11): 3178-3186, 2023 Nov.
Article En | MEDLINE | ID: mdl-37224374

OBJECTIVE: Current methods for transcutaneous blood gas monitoring (TBM) - a common health monitoring method in neonatal care - comes with a suite of challenges like limited attachment opportunities, and risks of infections from burning and tearing of the skin, which limits its use. This study presents a novel system and method for rate-based transcutaneous CO2 measurements with a soft, unheated skin-interface that can address many of these problems. Additionally, a theoretical model for the gas transport from the blood to the system's sensor is derived. METHODS: By simulating CO2 advection and diffusion through the cutaneous microvasculature and epidermis to the system's skin interface, the effect of a wide range of physiological properties on the measurement has been modeled. Following these simulations, a theoretical model for the relationship between the measured CO2 concentration and that in the blood was derived and compared to empirical data. RESULTS: Applying the model on measured blood gas levels, even when the theory was based solely on the simulations, produced blood CO2 concentrations within ∼35% of empirical measurements from a state-of-the-art device. Further calibration of the framework, also using the empirical data, yielded an output with a Pearson correlation of 0.84 between the two methods. CONCLUSION: Compared to the state-of-the-art device the proposed system measured the partial CO2 pressure in the blood with an average deviation of 0.04 kPa and 1.97σ of ±1.1 kPa. However, the model indicated that this performance could be hampered by different skin properties. SIGNIFICANCE: Given its soft and gentle skin interface and lack of heating, the proposed system could significantly decrease health risks like, burns, tears, and pain, currently associated with TBM on premature neonates.

17.
Commun Med (Lond) ; 3(1): 22, 2023 Feb 11.
Article En | MEDLINE | ID: mdl-36774374

BACKGROUND: Cardiac time-resolved CT (4D-CT) acquisitions provide high quality anatomical images of the heart. However, some cardiac diseases require assessment of blood flow in the heart. Diastolic dysfunction, for instance, is diagnosed by measuring the flow through the mitral valve (MV), while in atrial fibrillation, the flow through the left atrial appendage (LAA) indicates the risk for thrombus formation. Accurate validated techniques to extract this information from 4D-CT have been lacking, however. METHODS: To measure the flow rate though the MV and the LAA from 4D-CT, we developed a motion tracking algorithm that performs a nonrigid deformation of the surface separating the blood pool from the myocardium. To improve the tracking of the LAA, this region was deformed separately from the left atrium and left ventricle. We compared the CT based flow with 4D flow and short axis MRI data from the same individual in 9 patients. RESULTS: For the mitral valve flow, good agreement was found for the time span between the early and late diastolic peak flow (bias: <0.1 s). The ventricular stroke volume is similar compared to short-axis MRI (bias 3 ml). There are larger differences in the diastolic peak flow rates, with a larger bias for the early flow rate than the late flow rate. The peak LAA outflow rate measured with both modalities matches well (bias: -6 ml/s). CONCLUSIONS: Overall, the developed algorithm provides accurate tracking of dynamic cardiac geometries resulting in similar flow rates at the MV and LAA compared to 4D flow MRI.


Assessing the blood flow inside the heart is important in diagnosis and treatment of various cardiovascular diseases, such as atrial fibrillation or heart failure. We developed a method to accurately track the motion of the heart walls over the course of a heartbeat in three-dimensional Computed Tomography (CT) images. Based on the motion, we calculated the amount of blood passing through the mitral valve and the left atrial appendage orifice, which are markers used in the diagnostic of heart failure and assessment of stroke risk in atrial fibrillation. The results agreed well with measurements from 4D flow MRI, an imaging technique that measures blood velocities. Our method could broaden the use of CT and make additional exams redundant. It can even be used to calculate the blood flow inside the heart.

18.
Atherosclerosis ; 373: 46-54, 2023 05.
Article En | MEDLINE | ID: mdl-36813601

BACKGROUND AND AIMS: Elevated body weight in adolescence is associated with early cardiovascular disease, but whether this association is traceable to weight in early adulthood, weight in midlife or to weight gain is not known. The aim of this study is to assess the risk of midlife coronary atherosclerosis being associated with body weight at age 20, body weight in midlife and body weight change. METHODS: We used data from 25,181 participants with no previous myocardial infarction or cardiac procedure in the Swedish CArdioPulmonary bioImage Study (SCAPIS, mean age 57 years, 51% women). Data on coronary atherosclerosis, self-reported body weight at age 20 and measured midlife weight were recorded together with potential confounders and mediators. Coronary atherosclerosis was assessed using coronary computed tomography angiography (CCTA) and expressed as segment involvement score (SIS). RESULTS: The probability of having coronary atherosclerosis was markedly higher with increasing weight at age 20 and with mid-life weight (p < 0.001 for both sexes). However, weight increase from age 20 until mid-life was only modestly associated with coronary atherosclerosis. The association between weight gain and coronary atherosclerosis was mainly seen in men. However, no significant sex difference could be detected when adjusting for the 10-year delay in disease development in women. CONCLUSIONS: Similar in men and women, weight at age 20 and weight in midlife are strongly related to coronary atherosclerosis while weight increase from age 20 until midlife is only modestly related to coronary atherosclerosis.


Coronary Artery Disease , Myocardial Infarction , Adolescent , Humans , Female , Male , Adult , Middle Aged , Young Adult , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Coronary Artery Disease/complications , Coronary Angiography/methods , Myocardial Infarction/complications , Weight Gain , Body Weight , Risk Factors
19.
Clin Anat ; 36(3): 542-549, 2023 Apr.
Article En | MEDLINE | ID: mdl-36695446

Difficulties in achieving knowledge about physiology and anatomy of the beating heart highlight the challenges with more traditional pedagogical methods. Recent research regarding anatomy education has mainly focused on digital three-dimensional models. However, these pedagogical improvements may not be entirely applicable to cardiac anatomy and physiology due to the multidimensional complexity with moving anatomy and complex blood flow. The aim of this study was therefore to evaluate whether high quality time-resolved anatomical images combined with realistic blood flow simulations improve the understanding of cardiac structures and function. Three time-resolved datasets were acquired using time-resolved computed tomography and blood flow was computed using Computational Fluid Dynamics. The anatomical and blood flow information was combined and interactively visualized using volume rendering on an advanced stereo projection system. The setup was tested in interactive lectures for medical students. Ninety-seven students participated. Summative assessment of examinations showed significantly improved mean score (18.1 ± 4.5 vs 20.3 ± 4.9, p = 0.002). This improvement was driven by knowledge regarding myocardial hypertrophy and pressure-velocity differences over a stenotic valve. Additionally, a supplementary formative assessment showed significantly more agreeing answers than disagreeing answers (p < 0.001) when the participants subjectively evaluated the contribution of the visualizations to their education and knowledge. In conclusion, the use of simultaneous visualization of time-resolved anatomy data and simulated blood flow improved medical students' results, with a particular effect on understanding of cardiac physiology and these simulations may be useful educational tools for teaching complex anatomical and physiological concepts.


Anatomy , Education, Medical, Undergraduate , Physiology , Students, Medical , Humans , Education, Medical, Undergraduate/methods , Educational Measurement , Tomography, X-Ray Computed , Hemodynamics , Anatomy/education , Curriculum , Physiology/education
20.
Eur J Radiol ; 159: 110662, 2023 Feb.
Article En | MEDLINE | ID: mdl-36565594

PURPOSE: To quantitatively and qualitatively assess the visibility of bone structures in the wrist on photon-counting detector computed tomography (PCD-CT) images compared to state-of-the-art energy-integrating detector CT (EID-CT). METHOD: Four human cadaveric wrist specimens were scanned with EID-CT and PCD-CT at identical CTDIvol of 12.2 mGy and with 6.1 mGy (half dose PCD-CT). Axial images were reconstructed using the thinnest possible slice thickness, i.e. 0.4 mm on EID-CT and 0.2 mm on PCD-CT, with the largest image matrix size possible using reconstruction kernels optimized for bone (EID-CT: Ur68, PCD-CT: Br92). Quantitative evaluation was performed to determine contrast-noise ratio (CNR) of bone/ fat, cortical and trabecular sharpness. An observer study using visual grading characteristics (VGC) analysis was performed by six observers to assess the visibility of nutrient canals, trabecular architecture, cortical bone and the general image quality. RESULTS: At equal dose, images obtained with PCD-CT had 39 ± 6 % lower CNR (p = 0.001), 71 ± 57 % higher trabecular sharpness in the radius (p = 0.02) and 42 ± 8 % (p < 0.05) sharper cortical edges than those obtained with EID-CT. This was confirmed by VGC analysis showing a superior visibility of nutrient canals, trabeculae and cortical bone area under the curve (AUC) > 0.89) for PCD-CT, even at half dose. CONCLUSIONS: Despite a lower CNR and increased noise, the trabecular and cortical sharpness were twofold higher with PCD-CT. Visual grading analysis demonstrated superior visibility of cortical bone, trabeculae, nutrient canals and an overall improved image quality with PCD-CT over EID-CT. At half dose, PCD-CT also yielded superior image quality, both in quantitative measures and as evaluated by radiologists.


Photons , Wrist , Humans , Wrist/diagnostic imaging , Tomography, X-Ray Computed/methods , Bone and Bones/diagnostic imaging , Radiation Dosage , Phantoms, Imaging
...