Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Imaging ; 49: 12-16, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29120811

RESUMEN

Few reports in literature describe triple negative breast cancer (TNBC) imaging findings. Aim of the study is to determine MR-features of TNBC compared to receptor positive cancer (nTNBC). From May 2014 to May 2015, we retrospectively enrolled 31 consecutive patients with histological diagnosis of TNBC and a control group of 31 consecutive nTNBC observed in the same period, out of 602 cancer, diagnosed in our department in the same year. Histopathological analysis and MR-features of TNBC (31 patients) were compared to nTNBC (31 patients). MR-features included dimension, fibroglandular tissue (FGT), background parenchimal enhancement (BPE), mass shape, margins, presence of rim, intratumoral signal intensity in T2w, uni-multifocality, kinetic curves. All patients were examined with MR 1,5T (Magnetom Simphony Tim, Siemens Healthcare) performing T2w fat-sat and contrast enhanced high temporal and spatial resolution T1w before and after injection of Gadolinium. 62 staging MR were reviewed. Median age was 50 (30-78ys) with a standard deviation of 10,9. TNBC showed 3 MR features in concordance with current literature: rim enhancement, hyperintensity in T2 sequence and unifocality. Rim enhancement was shown in 67.7% of TNBC (21/31) and 29% of nTNBC (9/31). Higher T2w values were shown in 83.9% of TNBC (26/31) and 58.1% of nTNBC (18/31). Cancer was multifocal in 7/31 (22.6%) of TNBC and 19/31 (61.3%) nTNBC. No correlation was found for dimension (p=0.12), FGT (p=0.959), BPE (p=0.596), homogeneity of enhancement (p=0.43), margins (p=0.671) and kinetic (p=0.37). Multivariate analysis demonstrated that rim enhancement and unifocality correlated independently with TNBC group. Area under ROC curve of our model is 0.835. Furthermore, we evaluated the clinical outcome of all 31 TNBC patients in a follow-up time ranging from 24months to 36months separating them in a free-survival group (23 women) and a recurrence group (8 women with local recurrence or distant metastasis): only kinetic curves resulted to be significantly higher in recurrence group (p=0.042).


Asunto(s)
Neoplasias de la Mama/patología , Receptores de Estrógenos/metabolismo , Receptores de Progesterona/metabolismo , Adulto , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Curva ROC , Receptor ErbB-2/metabolismo , Estudios Retrospectivos , Neoplasias de la Mama Triple Negativas
2.
Eur J Radiol ; 81(2): 250-6, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21353421

RESUMEN

PURPOSE: To evaluate feasibility and image quality of time-resolved contrast-enhanced magnetic resonance angiography (CEMRA) of the left atrium-pulmonary veins (LA-PV) complex with half dose of intravenous gadolinium-based contrast agent (GBCA) in patients candidate to percutaneous radiofrequency ablation of atrial fibrillation. METHODS AND MATERIALS: Fifty-seven patients underwent CEMRA of the LA-PV complex on a 1.5T MRI scanner. On 24/57 patients, a conventional fast-spoiled gradient-echo (FSPGR) CEMRA acquisition was run using 0.2 mL/kg of 0.5M GBCA at 2 mL/s flow rate (protocol A), while in 33/57 patients a time-resolved multiphase CEMRA sequence (Time-Resolved Imaging of Contrast KineticS, TRICKS) was performed after intravenous injection of 0.1 mL/kg of the same GBCA at 3 mL/s flow rate (protocol B). Contrast enhancement was measured in the LA (LAe) and in the PA (PAe), and the LAe/PAe ratio was calculated. Diagnostic quality of Maximum Intensity Projection (MIP), Volume Rendering (VR), and Virtual Endoscopy (VE) reconstructions was also assessed visually using a semiquantitative score. RESULTS: LAe was comparable with both protocols, while PAe was lower with protocol B than with protocol A (p = 0.0217). Moreover, the LAe/PAe ratio was significantly higher with protocol B than with protocol A (p = 0.0044). Finally, image quality of MIP, VR, and VE reconstructions was significantly better with protocol B than with protocol A (p = 0.0005, p = 0.0001, and p = 0.005, respectively). CONCLUSIONS: CEMRA of the LA-PV complex is feasible with TRICKS and half-dose GBCA and yields better separation between the LA-PV complex and the PA, as well as better image quality of MIP, VR, and VE reconstructions than a conventional FSPGR sequence performed with full GBCA dose.


Asunto(s)
Atrios Cardíacos/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Meglumina/análogos & derivados , Compuestos Organometálicos , Venas Pulmonares/patología , Adulto , Anciano , Medios de Contraste/administración & dosificación , Estudios de Factibilidad , Humanos , Inyecciones Intravenosas , Meglumina/administración & dosificación , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Eur J Radiol ; 80(2): 303-9, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20832219

RESUMEN

PURPOSE: To evaluate the influence of CAD for the evaluation of CT colonography (CTC) datasets by inexperienced readers during the attendance of a dedicated hands-on training course. METHOD AND MATERIALS: Twenty-seven radiologists inexperienced in CTC (11 with no CTC training at all, 16 having previously reviewed no more than 10 CTC cases overall) attended a hands-on training course based on direct teaching on fifteen workstations (four Advantage Windows 4.4 with Colon VCAR software, GE; six CADCOLON, Im3D; five ColonScreen (Toshiba/Voxar) with ColonCAD™ API, Medicsight). During the course, readers were instructed to analyze 26 CTC cases including 38 colonic lesions obtained through low-dose MDCT acquisitions, consisting of 12 polyps sized less than 6 mm, 9 polyps sized between 6 and 10 mm, 12 polyps sized between 11 mm and 30 mm, and 5 colonic masses sized>3 cm. CTC images were reviewed by each reader both in 2D and 3D mode, respectively by direct evaluation of native axial images and MPR reconstructions, and virtual endoscopy or dissected views. Each reader had 15 min time for assessing each dataset without CAD, after which results were compared with those provided by CAD software. Global rater sensitivity for each lesion size before and after CAD usage was compared by means of two-tailed Student's t test, while sensitivity of each single reader before and after CAD usage was assessed with the McNemar test. RESULTS: For lesions sized<6 mm, global rater sensitivity was 0.1852±0.1656 (mean±SD) before CAD-assisted reading and 0.2345±0.1761 after CAD (p=0.0018). For lesions sized 6-9 mm, sensitivity was 0.2870±0.1016 before CAD-assisted reading and 0.3117±0.1099 after CAD (p=0.0027). For lesions sized 10-30 mm, sensitivity was 0.5308±0.2120 before CAD-assisted reading and 0.5637±0.2133 after CAD (p=0.0086), while for lesions sized>30 mm, sensitivity before CAD-assisted reading was 0.3556±0.3105 and did not change after CAD usage (p=1). Sensitivity of each single rater did not significantly differ before and after CAD for any lesion size category (McNemar test, p>0.05). Specificity was not significantly different before and after CAD for any lesion size (>96% for all size categories). CONCLUSION: CAD usage led to increased overall sensitivity of inexperienced readers for all polyps sizes, except for lesions>30 mm, but sensitivity of individual raters was not significantly higher compared with CAD-unassisted reading.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Radiología/educación , Medios de Contraste , Diagnóstico por Computador/métodos , Diatrizoato de Meglumina , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad , Programas Informáticos
4.
Abdom Imaging ; 36(6): 713-7, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21161217

RESUMEN

PURPOSE: To evaluate patients' preferences regarding follow-up of medium size polyps detected at screening CT colonography (CTC). METHODS AND MATERIALS: 193 C-RADS2 asymptomatic patients were asked to fill in a form explaining the indications, technique and potential complications of CTC, and were invited to choose their preferred examination technique (CTC or optical colonoscopy: OC) and their follow-up interval by repeated consultations at 3-month intervals. The follow-up interval for CTC and OC was recorded. RESULTS: 87/193 C-RADS2 patients (45.1%) accepted follow-up. Average time interval for follow-up was comparable between CTC and OC (9.00 ± 4.24 vs. 9.00 ± 4.39 months, respectively; P = 0.7188). No patients chose to undergo a 3-year follow-up with either CTC or OC. Most patients elected to have follow-up with either CTC or OC before 18 months rather than later (P = 0.0004). CONCLUSIONS: A substantial fraction of C-RADS2 patients prefer to undergo immediate OC and polyp removal rather than follow-up, and the majority of those accepting follow-up are willing to wait for less than 18 months. Such findings may suggest a revision of the proposed C-RADS2 category.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Prioridad del Paciente , Anciano , Sulfato de Bario/administración & dosificación , Catárticos/administración & dosificación , Colonoscopía , Medios de Contraste/administración & dosificación , Diatrizoato de Meglumina/administración & dosificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polietilenglicoles/administración & dosificación , Estudios Prospectivos , Estadísticas no Paramétricas
5.
Eur Radiol ; 21(1): 113-21, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20652255

RESUMEN

OBJECTIVES: To evaluate the technical feasibility of 64-row computed tomography (CT) quantitative perfusion imaging of head and neck squamous cell carcinoma (SCC). METHODS: Twenty-nine patients with a total of 29 pathologically proven SCC underwent a cine-mode CT perfusion acquisition covering the lesion site. The acquisition started 10 s after intravenous injection of iodinated contrast material and lasted 50 s. On a dedicated workstation, regions of interest (ROI) were traced within the SCC, on a healthy portion of tissue (H), and on the ipsilateral sternocleidomastoid muscle (M). Blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability-surface product (PS) were calculated. RESULTS: In SCC, BF, BV and PS were higher compared with H (p<0.0001, p=0.002 and p=0.004, respectively) and M (p<0.0001). Conversely, MTT was lower in SCC than in H (p=0.0009) and M (p=0.0003). All datasets were free from substantial motion artefacts and ROI misregistration phenomena. No substantial discomfort or adverse events were experienced by any of the patients. CONCLUSION: 64-row CT quantitative perfusion imaging allows head and neck SCC to be distinguished from normal tissues.


Asunto(s)
Carcinoma de Células Escamosas/patología , Medios de Contraste , Neoplasias de Cabeza y Cuello/patología , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Estudios de Factibilidad , Femenino , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad
6.
Eur Radiol ; 20(2): 303-8, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19760422

RESUMEN

OBJECTIVE: To evaluate the role of mean diffusivity (MD) as a predictive index of the response to chemotherapy in locally advanced breast cancer. METHODS: Twenty-one women referred to our institution with a diagnosis of locally advanced breast cancer underwent magnetic resonance imaging (MRI) studies at 1.5 T before beginning and after completing combined neoadjuvant chemotherapy. The examination protocol included an EPI sequence sensitised to diffusion (b-value 1,000 s/mm(2)) and three-dimensional (3D) coronal T1 sequences before and after intravenous contrast medium. Tumours were delineated by using dynamic MR acquisition before and after chemotherapy. The percentage of tumour volume reduction (PVR) and pre-(MD(pre)) and post-therapy (MD(post)) MD values were computed for each lesion. RESULTS: PVR >or= 65% was observed in 17/21 patients (responders). MD(pre) of responders (0.99 +/- 0.27 10(-3) mm(2)/s) was significantly (p = 0.025) lower than MD(pre) of non-responders (1.46 +/- 0.33 10(-3) mm(2)/s). Moreover, in patients as a whole PVR significantly correlated (p = 0.01, r = -0.54) with MD(pre). MD(post) (1.26 +/- 0.39 10(-3) mm(2)/s) of responders was significantly(p = 0.024) higher than MD(pre) (0.99 +/- 0.27 mm(2) 10(-3) mm(2)/s), whereas non-responders MD(post) (1.00 +/- 0.14 10(-3) mm(2)/s)did not increase compared with MD(pre) (1.46 +/- 0.33 10(-3) mm(2)/s). CONCLUSIONS: This preliminary study seems to indicate that low values of pre-chemotherapy MD may identify, before starting treatment, the patients with higher probability of response in terms of percentage of volume reduction of the lesion. MD may represent a complementary parameter useful to correctly select patients for neoadjuvant chemotherapy.


Asunto(s)
Algoritmos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/tratamiento farmacológico , Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Anciano , Ciclofosfamida/uso terapéutico , Epirrubicina/uso terapéutico , Femenino , Fluorouracilo/uso terapéutico , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Proyectos Piloto , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...