Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Ann Vasc Surg ; 96: 166-175, 2023 Oct.
Article En | MEDLINE | ID: mdl-37169247

BACKGROUND: Cardiovascular complications are a major cause of morbidity and mortality in the postoperative period after major vascular surgery. Depending on the study population, up to 25% of patients have troponin elevation after noncardiac surgery, yet many do not meet the diagnosis of myocardial infarction (MI). Although outcomes of routine troponin elevation in patients undergoing mixed major vascular surgery have been evaluated, this has not been studied exclusively in elective, open abdominal aortic aneurysm repair (oAAA), especially regarding perioperative and overall mortality. METHODS: We conducted a single-center, retrospective review of routine troponin surveillance for consecutive, oAAA from 2014 to 2019. A total of 319 patients were identified and analyzed for management patterns and interventions. The cohort was stratified into groups for comparison based on those in whom troponin was routinely checked (RC) as part of a care strategy during the study period, not routinely checked (NRC), elevated troponin (ET) >0.001 ng/mL, and not elevated. The median follow-up was 21.5 ± 23.8 months. Groups were compared on demographic data, cardiac comorbidities, 30-day and 3-year outcomes for MI and death using two-sample t-tests, Wilcoxon rank sum tests, Pearson chi-square tests, and Fisher exact tests when appropriate. RESULTS: Troponin was measured in 83.7% (267/319) of patients who underwent elective oAAA repair. Routine troponin checks were obtained in 79.9% (255/319) of patients. ET was identified in 16.5% of those with RC (42/255) and 4.7% of those with NRC (3/64). Of patients with ET, 37.8% (17/45) had a cardiology consultation, 4.4% (2/45) had a percutaneous coronary intervention (PCI), and 4.4% (2/45) had another cardiac intervention. All 4 patients undergoing PCI or other cardiac intervention had received routine troponin checks. Patients with ET were older (71.2 vs. 68.6; P = 0.04), more likely to receive intraoperative blood products (P = 0.003), had longer operative times (P = 0.011), higher length of stay (9 vs. 7 days; P < 0.01), and higher 30-day MI rate (3 vs. 0; P = 0.04). They had neither longer aortic clamp times nor worse preoperative cardiac function, and the proximal clamp position during oAAA repair did not impact troponin detection. Additionally, 3-year overall mortality was increased in patients who had ET but there was not a significant difference in 3-year mortality between groups receiving routine troponin checks versus not. CONCLUSIONS: ET, identified after elective oAAA repair, was associated with a higher risk of 30-day MI and lower overall survival. However, it was not demonstrated that routine assessment of troponin levels postoperatively leads to decreased 3-year mortality in this setting.


Aortic Aneurysm, Abdominal , Myocardial Infarction , Percutaneous Coronary Intervention , Plastic Surgery Procedures , Humans , Treatment Outcome , Vascular Surgical Procedures/adverse effects , Myocardial Infarction/diagnosis , Myocardial Infarction/etiology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery
2.
J Vasc Surg ; 77(3): 778-784, 2023 03.
Article En | MEDLINE | ID: mdl-37221895

OBJECTIVE: The Society for Vascular Surgery published abdominal aortic aneurysm (AAA) practice guidelines in 2003, 2009, and 2018 to improve the management and treatment of AAAs. In 2014, our vascular surgery department implemented a quarterly AAA dashboard (AAAdb) to record the perioperative outcomes and guideline compliance with a focus on intervention appropriateness and procedural follow-up, which supplemented our Vascular Quality Initiative data. From the available reported evidence and expert consensus opinions, nine additional criteria for the appropriate treatment of AAAs <5 cm in women and <5.5 cm in men were noted, when applicable. The purpose of our study was to assess the effects of AAAdb implementation on adherence to society and institutional guidelines, documentation of treatment rationale, and the quality of follow-up. METHODS: We performed a retrospective review of elective open and endovascular AAA repair at a single institution from 2010 to 2018. The AAAdb was implemented in the middle of this period in 2014. The patient demographics, aortic size, repair indication, repair type, 30-day mortality, and postoperative and 1-year follow-up imaging findings were analyzed. The primary outcome was adherence to intervention appropriateness and the follow-up guidelines. The categorical factors were summarized using frequencies and percentages and compared using the Pearson χ2 test or Fisher exact test. Continuous measures were summarized using the mean ± standard deviation and compared between study periods using two-sample t tests. RESULTS: From 2010 to 2018, 1549 patients had undergone elective AAA repair: 657 before and 892 after AAAdb implementation. No differences were found in AAA size after AAAdb (5.6 ± 1.2 cm vs 5.6 ± 1.1 cm; P = .88). However, the proportion of size-appropriate repairs increased (64.1% vs 71.3%; P = .003). The proportion of small AAA repairs with a documented rationale had increased (64.4% vs 80.5%; P < .001), with rapid disease progression cited most often. No difference was found in 30-day mortality (1.2% vs 1.5%; P = .69). Follow-up imaging after endovascular abdominal aortic aneurysm repair increased at <60 days postoperatively (76% vs 84%; P = .004) and at 1 year of follow-up (78% vs 86%; P = .0005). The proportion of patients with endoleak at <60 days postoperatively had increased in the post-AAAdb cohort (21% vs 29%; P = .012). CONCLUSIONS: The AAAdb served as a centerpiece for improving the appropriateness of care and compliance with national and institutional guidelines, including treatment of small AAAs in special circumstances. Its implementation was associated with higher quality follow-up and surveillance in a high-volume, regional aortic center. Consideration should be given to adding additional criteria to the Society for Vascular Surgery guidelines and Vascular Quality Initiative reporting.


Aortic Aneurysm, Abdominal , Male , Humans , Female , Aorta , Consensus , Data Accuracy
3.
J Vasc Surg ; 76(3): 733-740.e2, 2022 09.
Article En | MEDLINE | ID: mdl-35278651

OBJECTIVE: The Gore Excluder iliac branch endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, AZ) is the only iliac branch device approved in the United States to preserve blood flow to the external and internal iliac arteries (IIAs). Some surgeons have used the Gore Viabahn VBX balloon expandable endoprosthesis (VBX; W.L. Gore & Associates) in the IIA rather than the self-expanding endograft designed for the IBE, the internal iliac component (IIC). The objective of the present study was to examine the outcomes for patients treated for aortoiliac artery aneurysms using the IBE with either the IIC or VBX stent. METHODS: We performed a retrospective, single-center review of patients treated for aortoiliac artery aneurysms using the Gore IBE device, with either the IIC or VBX stent into the IIA, from February 2016 to March 2021. The patient demographics, procedure details, 30-day morbidity and mortality, and 6-month and 1-year outcomes and mortality were analyzed. The categorical factors are summarized using frequencies and proportions. Continuous measures are summarized as the mean ± standard deviation. A significance level of P = .05 was assumed for all test results. The analyses were performed using SAS software, version 9.4 (SAS Institute, Cary, NC). RESULTS: A total of 62 patients (64 arteries) had undergone elective aortoiliac artery aneurysm repair with the IBE. The IIC was used exclusively in 35 cases (55%) and the VBX in 29 (45%). The patients who had received the VBX had had a higher American Society of Anesthesiologists class (P = .006). Upper extremity access was used for VBX delivery in 24.1% of the procedures. No return to the operating room was required in either group. No differences were found in technical success (IIC, 97.1%; VBX, 93.1%; P = .59), the presence of endoleak on completion (20.0% vs 6.9%; P = .17), readmission (97.1% vs 93.1%; P = .59), or mortality (1.6% vs 0%; P = .45) at 30 days. No differences were found in the requirement for any IBE reintervention after 30 days. No type Ia, Ib, or III endoleaks had occurred in either group at any follow-up point. No significant difference was found in internal iliac limb primary patency (IIC, 100%; VBX, 96.3%) between groups. A nonstatistically significant trend was found toward fewer trunk-ipsilateral leg type II endoleaks in the VBX group during follow-up. CONCLUSIONS: These data suggest that the VBX is a reasonable substitute for the IIC, with a comparable safety and efficacy profile. Given its inherent conformability, greater range of diameters, and longer working length, the VBX stent offers expanded IIA branch options with the IBE.


Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/etiology , Iliac Aneurysm/surgery , Prosthesis Design , Retrospective Studies , Time Factors , Treatment Outcome , Vascular Patency
...