Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Magn Reson ; 353: 107496, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37320959

RESUMEN

We present an apparatus that applies Ramsey's method of separated oscillatory fields to proton spins in water molecules. The setup consists of a water circuit, a spin polarizer, a magnetically shielded interaction region with various radio frequency elements, and a nuclear magnetic resonance system to measure the spin polarization. We show that this apparatus can be used for Rabi resonance measurements and to investigate magnetic and pseudomagnetic field effects in Ramsey-type precision measurements with a sensitivity below 100 pT.

2.
Phys Rev Lett ; 129(19): 191801, 2022 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-36399752

RESUMEN

We report on a search for dark matter axionlike particles (ALPs) using a Ramsey-type apparatus for cold neutrons. A hypothetical ALP-gluon coupling would manifest in a neutron electric dipole moment signal oscillating in time. Twenty-four hours of data have been analyzed in a frequency range from 23 µHz to 1 kHz, and no significant oscillating signal has been found. The usage of present dark-matter models allows one to constrain the coupling of ALPs to gluons in the mass range from 10^{-19} to 4×10^{-12} eV. The best limit of C_{G}/f_{a}m_{a}=2.7×10^{13} GeV^{-2} (95% C.L.) is reached in the mass range from 2×10^{-17} to 2×10^{-14} eV.

3.
Phys Rev Lett ; 126(7): 070401, 2021 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-33666459

RESUMEN

We have recently shown how a polarized beam in Talbot-Lau interferometric imaging can be used to analyze strong magnetic fields through the spin dependent differential phase effect at field gradients. While in that case an adiabatic spin coupling with the sample field is required, here we investigate a nonadiabatic coupling causing a spatial splitting of the neutron spin states with respect to the external magnetic field. This subsequently leads to no phase contrast signal but a loss of interferometer visibility referred to as dark-field contrast. We demonstrate how the implementation of spin analysis to the Talbot-Lau interferometer setup enables one to recover the differential phase induced to a single spin state. Thus, we show that the dark-field contrast is a measure of the quantum mechanical spin split analogous to the Stern-Gerlach experiment without, however, spatial beam separation. In addition, the spin analyzed dark-field contrast imaging introduced here bears the potential to probe polarization dependent small-angle scattering and thus magnetic microstructures.

4.
Nat Commun ; 10(1): 3788, 2019 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-31439848

RESUMEN

The intrinsic magnetic moment of a neutron, combined with its charge neutrality, is a unique property which allows the investigation of magnetic phenomena in matter. Here we present how the utilization of a cold polarized neutron beam in neutron grating interferometry enables the visualization and characterization of magnetic properties on a microscopic scale in macroscopic samples. The measured signal originates from the phase shift induced by the magnetic potential. Our method enables the detection of previously inaccessible magnetic field gradients, in the order of T cm-1, extending the probed range by an order of magnitude. We visualize and quantify the phase shift induced by a well-defined square shaped uniaxial magnetic field and validate our experimental findings with theoretical calculations based on Hall probe measurements of the magnetic field distribution. This allows us to further extend our studies to investigations of inhomogeneous and anisotropic magnetic field distribution.

5.
Phys Rev Lett ; 112(22): 224801, 2014 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-24949772

RESUMEN

A 10 MeV/c positive muon beam was stopped in helium gas of a few mbar in a magnetic field of 5 T. The muon "swarm" has been efficiently compressed from a length of 16 cm down to a few mm along the magnetic field axis (longitudinal compression) using electrostatic fields. The simulation reproduces the low energy interactions of slow muons in helium gas. Phase space compression occurs on the order of microseconds, compatible with the muon lifetime of 2 µs. This paves the way for the preparation of a high-quality low-energy muon beam, with an increase in phase space density relative to a standard surface muon beam of 10^{7}. The achievable phase space compression by using only the longitudinal stage presented here is of the order of 10^{4}.

6.
Phys Rev Lett ; 108(18): 181801, 2012 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-22681056

RESUMEN

We report on a neutron particle physics experiment, which provides for the first time an upper limit on the strength of an axial coupling constant for a new light spin 1 boson in the millimeter range. Such a new boson would mediate a new force between ordinary fermions, like neutrons and protons. The experiment was set up at the cold neutron reflectometer Narziss at the Paul Scherrer Institute and uses Ramsey's technique of separated oscillating fields to search for a pseudomagnetic neutron spin precession induced by this new interaction. For the axial coupling constant g(A)(2), an upper limit of 6×10(-13) (95% C.L.) was determined for an interaction range of 1 mm.

7.
Phys Rev Lett ; 107(13): 134801, 2011 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-22026860

RESUMEN

Ultracold neutrons (UCNs) play an important role for precise measurements of the properties of the neutron and its interactions. During the past 25 years, a neutron turbine coupled to a liquid deuterium cold neutron source at a high-flux reactor has defined the state of the art for UCN production, despite a long history of efforts towards a new generation of UCN sources. This Letter reports a world-best UCN density available for users, achieved with a new source based on conversion of cold neutrons in superfluid helium. A conversion volume of 5 liters provides at least 274,000 UCN in a single accumulation run. Cyclically repeated operation of the source has been demonstrated, as well.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...