1.
Radiography (Lond) ; 28(3): 746-750, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35397956

RESUMEN

INTRODUCTION: In response to advice from The National Institute for Health and Care Excellence (1) to reduce hospital visits during COVID-19, standard headrests were introduced for head and neck radiotherapy within Northern Centre for Cancer Care (NCCC). The standard headrest requires one mould room appointment compared to 3 appointments with customised headrests. METHODS: Two groups of 10 patients treated between December 2019 and June 2020 were retrospectively analysed by 1 observer. Groups were stratified according to age, sex and tumour site. One group had customised headrest and the other had standard headrest. Five hundred and forty seven cone beam computed tomography images were reviewed. A 6 Degree of Freedom match was performed then chin, shoulder and spine position were assessed using dosimetrist drawn structures. Structures out of the tolerance were recorded. A chi-squared test was used for statistical analysis. RESULTS: The out of tolerance chin position count recorded was 21 for customised headrest and 36 for standard headrest, p-value 0.046. The shoulder position count was 13 for customised headrest and 77 for standard headrest p-value <0.001. The spine position count was 3 for CHR and 21 for standard headrest, p-value <0.001. This means the headrests compared are not equivalent in terms of set up reproducibility. Overall the standard headrest group had 10 set-up re-scans and no set up re-scans were recorded in the customised headrest group. CONCLUSION: Fewer hospital visits with SHR reduce patient exposure to COVID-19. However, CHR provided a more reliable level of immobilisation in this study. IMPLICATIONS FOR PRACTICE: The radiotherapy service will be reviewed in line with these findings.


Asunto(s)
COVID-19 , Cabeza , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
Br J Radiol ; 85(1014): 819-23, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22665927

RESUMEN

Stereotactic body radiotherapy for early stage non-small cell lung cancer is an emerging treatment option in the UK. Since relatively few high-dose ablative fractions are delivered to a small target volume, the consequences of a geometric miss are potentially severe. This paper presents the results of treatment delivery set-up data collected using Elekta Synergy (Elekta, Crawley, UK) cone-beam CT imaging for 17 patients immobilised using the Bodyfix system (Medical Intelligence, Schwabmuenchen, Germany). Images were acquired on the linear accelerator at initial patient treatment set-up, following any position correction adjustments, and post-treatment. These were matched to the localisation CT scan using the Elekta XVI software. In total, 71 fractions were analysed for patient set-up errors. The mean vector error at initial set-up was calculated as 5.3 ± 2.7 mm, which was significantly reduced to 1.4 ± 0.7 mm following image guided correction. Post-treatment the corresponding value was 2.1 ± 1.2 mm. The use of the Bodyfix abdominal compression plate on 5 patients to reduce the range of tumour excursion during respiration produced mean longitudinal set-up corrections of -4.4 ± 4.5 mm compared with -0.7 ± 2.6 mm without compression for the remaining 12 patients. The use of abdominal compression led to a greater variation in set-up errors and a shift in the mean value.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/cirugía , Tomografía Computarizada de Haz Cónico , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/cirugía , Posicionamiento del Paciente/normas , Radiocirugia/métodos , Humanos
6.
Occup Med (Lond) ; 43(3): 119-20, 1993 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8400202
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...