Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Intervalo de año de publicación
1.
Acta Ortop Bras ; 32(3): e276755, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39086845

RESUMEN

Objective: The objective of the research was to carry out a comparative study between Smith & Nephew ® or Zimmer ® prostheses with thick versus thin polyethylene, in patients undergoing primary total knee arthroplasty, during a short-term follow-up. Thus, the objective was to analyze the survival of the implants in question under the clinical and radiographic aspect. Methods: The sample was divided into two groups: Group 1 with thick polyethylene and group 2 with thin polyethylene. A clinical analysis of the patients was carried out and the implants were checked for loosening. Results: The groups were similar when compared. According to the Ahlbäck classification, 83% of the patients were in groups IV and V. The median functional score in the postoperative period was similar between the two groups. Postoperatively, the tibiofemoral angle fluctuated between 5 and 6 0 valgus on average. Two complications were observed in each group. None of the evaluated patients presented implant loosening. Conclusion: Patients treated with thick polyethylene had the same functional score as the control group, as well as the absence of radiographic changes in this short-term follow-up, with implant survival and a similar rate of complications between both groups. Level of evidence III, Retrospective study.


Objetivo: O objetivo desta pesquisa foi realizar um estudo comparativo entre as próteses Smith & Nephew ® e Zimmer ®, com polietileno espesso versus o fino, em pacientes submetidos à artroplastia total primária do joelho, durante um seguimento de curto prazo. Dessa forma, foi analisada a sobrevida dos implantes em questão sob o aspecto clínico e radiográfico. Métodos: A amostra foi dividida em dois grupos: grupo 1 com polietileno espesso e grupo 2 com polietileno fino. Foi realizada análise clínica dos pacientes e verificado se ocorreu soltura dos implantes. Resultados: Os grupos tiveram resultados semelhantes quando comparados. Segundo a classificação de Ahlbäck, 83% dos pacientes eram dos grupos IV e V. A mediana do escore funcional no pós-operatório foi similar entre os grupos. No pós-operatório o ângulo tíbio-femoral oscilou na média entre 5 e 6 0 de valgo. Foram observadas duas complicações em cada grupo. Nenhum dos pacientes avaliados apresentou soltura do implante. Conclusão: Os pacientes tratados com o polietileno espesso apresentaram o mesmo escore funcional do grupo controle, assim como ausência de alterações radiográficas nesse seguimento de curto prazo, com sobrevida do implante e índice de complicações similar entre ambos os grupos. Nível de evidência III, Estudo retrospectivo.

2.
Arch Orthop Trauma Surg ; 144(7): 3053-3061, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38960933

RESUMEN

INTRODUCTION: Iliac crest autograft is frequently used to fill in bone defects after osteotomies. Nonetheless, surgery for bone autograft procurement is associated with morbidity and pain at the donor site. Alternatives to it have been explored, but there is no consensus to guide their application as a routine practice in several orthopedic procedures. Thus, this study was designed to compare the efficacy and safety between iliac crest autograft and allograft in medial opening wedge high tibial osteotomy. MATERIALS AND METHODS: Forty-seven patients with a symptomatic unilateral genu varum and an indication for high tibial osteotomy were randomly assigned to receive either autograft or allograft to fill the osteotomy site. Operative time, bone healing, and complication rates (delayed union, nonunion, superficial and deep infection, loss of correction, and hardware failure) were recorded after a one-year follow-up. Data were expressed as Mean ± Standard Deviation and considered statistically significant when p < 0.05. RESULTS: The time to radiologic union was similar between both groups (Allograft: 2.38 ± 0.97 months vs. Autograft: 2.45 ± 0.91 months; p = 0.79). Complication rates were also similar in both groups, with one infection in the allograft group and two in the autograft group, two delayed unions in the allograft group, and three in the autograft group. The operative time differed by 11 min between the groups, being lower in the allograft group (Allograft: 65.4 ± 15.1 min vs. Autograft: 76.3 ± 15.2 min; p = 0.02). CONCLUSION: Iliac crest allografts can be safely and effectively used in medial opening wedge high tibial osteotomy as it promotes the same rates of bone union as those achieved by autologous grafts, with the benefits of a shorter operative time. TRIAL REGISTRATION NUMBER: U1111-1280-0637 1 December 2022, retrospectively registered.


Asunto(s)
Trasplante Óseo , Ilion , Tempo Operativo , Osteotomía , Tibia , Humanos , Ilion/trasplante , Osteotomía/métodos , Masculino , Femenino , Tibia/cirugía , Adulto , Trasplante Óseo/métodos , Persona de Mediana Edad , Aloinjertos , Autoinjertos , Trasplante Autólogo/métodos , Genu Varum/cirugía , Trasplante Homólogo/métodos , Cicatrización de Heridas
3.
Acta ortop. bras ; 32(3): e276755, 2024. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1563679

RESUMEN

ABSTRACT Objective: The objective of the research was to carry out a comparative study between Smith & Nephew ® or Zimmer ® prostheses with thick versus thin polyethylene, in patients undergoing primary total knee arthroplasty, during a short-term follow-up. Thus, the objective was to analyze the survival of the implants in question under the clinical and radiographic aspect. Methods: The sample was divided into two groups: Group 1 with thick polyethylene and group 2 with thin polyethylene. A clinical analysis of the patients was carried out and the implants were checked for loosening. Results: The groups were similar when compared. According to the Ahlbäck classification, 83% of the patients were in groups IV and V. The median functional score in the postoperative period was similar between the two groups. Postoperatively, the tibiofemoral angle fluctuated between 5 and 6 0 valgus on average. Two complications were observed in each group. None of the evaluated patients presented implant loosening Conclusion: Patients treated with thick polyethylene had the same functional score as the control group, as well as the absence of radiographic changes in this short-term follow-up, with implant survival and a similar rate of complications between both groups. Level of evidence III, Retrospective study.


RESUMO Objetivo: O objetivo desta pesquisa foi realizar um estudo comparativo entre as próteses Smith & Nephew ® e Zimmer ®, com polietileno espesso versus o fino, em pacientes submetidos à artroplastia total primária do joelho, durante um seguimento de curto prazo. Dessa forma, foi analisada a sobrevida dos implantes em questão sob o aspecto clínico e radiográfico. Métodos: A amostra foi dividida em dois grupos: grupo 1 com polietileno espesso e grupo 2 com polietileno fino. Foi realizada análise clínica dos pacientes e verificado se ocorreu soltura dos implantes. Resultados: Os grupos tiveram resultados semelhantes quando comparados. Segundo a classificação de Ahlbäck, 83% dos pacientes eram dos grupos IV e V. A mediana do escore funcional no pós-operatório foi similar entre os grupos. No pós-operatório o ângulo tíbio-femoral oscilou na média entre 5 e 6 0 de valgo. Foram observadas duas complicações em cada grupo. Nenhum dos pacientes avaliados apresentou soltura do implante. Conclusão: Os pacientes tratados com o polietileno espesso apresentaram o mesmo escore funcional do grupo controle, assim como ausência de alterações radiográficas nesse seguimento de curto prazo, com sobrevida do implante e índice de complicações similar entre ambos os grupos. Nível de evidência III, Estudo retrospectivo.

4.
J Orthop ; 40: 29-33, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37159823

RESUMEN

Background: This study aimed to identify the predictive and protective factors of blood transfusion in patients undergoing total knee arthroplasty (TKA) and therefore determine the profile of patients with low and high risk of blood transfusion after arthroplasty. Methods: We conducted a retrospective study with all patients who underwent primary TKA between January 2017 and December 2019 (n = 1.028 patients) in our institution. Information about allogenic transfusion was collected from medical records to determine the incidence, the predictive and protective factors of blood transfusion. All cases of blood transfusions were documented as well the number of units and the moment of each transfusion. We performed univariate and multivariate logistic regression analyses to identify the independent risk and protective factors. Results: The total transfusion rate was 11%, 1.1% at intraoperative and 9,9% at postoperative period. The independent risk factors for transfusion were female gender (OR 1.64), older age (>55yo, OR > 2) higher surgical risk (ASA III, OR 3.07), lower preoperative hemoglobin levels (p = 0.024), post-traumatic arthritis (OR 4.11) and use of postoperative drains (OR 1.81) The protective factors for transfusion were male gender (OR 0.60), obesity (IMC >30, OR 0.60) and use of intravenous tranexamic acid intraoperatively (OR 0.40). Conclusions: We conclude that in addition to the well-established risk factors for blood transfusion such as advanced age, low hemoglobin levels and high surgical risk, we can add post-fracture arthroplasty, non-use of tranexamic acid and the use of postoperative joint drain.

5.
Acta Ortop Bras ; 30(4): e250492, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36092171

RESUMEN

Objective: This research sought to carry out a comparative study observing the clinical and radiographic analysis of primary prostheses of the type TC3 Depuy Johnson® with or without a stem during a short-term follow-up. Methods: The sample was divided into three groups: Group 1 (with stem), Group 2 (without stem) and Group 3 (mixed). Patients were evaluated to assess whether the implants were loosening and a clinical analysis was performed. Results: Preoperative deformities were predominantly considered severe. The total range of motion in the postoperative period was above 96.7° in the three groups. In the postoperative period, the femoral-tibial angle oscillated on average between 5 to 6° valgus. There was no record of implant loosening for cases treated with stem, and the incidence of loosening was 14.3% for the group without stem and 16.7% among cases in the mixed group. Conclusion: In general, preoperative deformities were considered severe. In the postoperative period, the total range of motion was above 96.7°. The postoperative femoral-tibial angle obtained an average of 5 to 6° valgus. There is no significant difference in implants loosening in the three groups. Level of Evidence III, Retrospective Comparative Study.


Objetivo: Realizar um estudo comparativo observando a análise clínica e radiográfica das próteses primárias do tipo TC3 Johnson ® com ou sem haste durante um seguimento de curto prazo. Métodos: A amostra foi dividida em três grupos: Grupo 1 com haste, Grupo 2 sem haste e Grupo 3 misto. Foi realizada a análise clínica dos pacientes e verificado se ocorreu soltura dos implantes. Resultados: As deformidades pré-operatórias foram predominantemente graves. O arco de movimento total no pós-operatório foi acima de 96,7° nos três grupos. No pós-operatório o ângulo tíbio-femoral oscilou na média entre 5 e 6° de valgo. Não houve registro de soltura do implante para os casos tratados com haste; a incidência de soltura foi de 14,3% entre os casos do grupo sem haste e de 16,7% entre os casos do grupo misto. Conclusão: Em geral, as deformidades pré-operatórias foram consideradas graves. No pós-operatório a amplitude total do arco de movimento foi acima de 96,7°. O ângulo tíbio-femoral pós-operatório obteve uma média entre 5 e 6° de valgo. Não há diferença significativa na soltura dos implantes nos três grupos. Nível de Evidência III, Estudo Retrospectivo Comparativo.

6.
Acta ortop. bras ; 30(4): e250492, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1393784

RESUMEN

ABSTRACT Objective: This research sought to carry out a comparative study observing the clinical and radiographic analysis of primary prostheses of the type TC3 Depuy Johnson® with or without a stem during a short-term follow-up. Methods: The sample was divided into three groups: Group 1 (with stem), Group 2 (without stem) and Group 3 (mixed). Patients were evaluated to assess whether the implants were loosening and a clinical analysis was performed. Results: Preoperative deformities were predominantly considered severe. The total range of motion in the postoperative period was above 96.7° in the three groups. In the postoperative period, the femoral-tibial angle oscillated on average between 5 to 6° valgus. There was no record of implant loosening for cases treated with stem, and the incidence of loosening was 14.3% for the group without stem and 16.7% among cases in the mixed group. Conclusion: In general, preoperative deformities were considered severe. In the postoperative period, the total range of motion was above 96.7°. The postoperative femoral-tibial angle obtained an average of 5 to 6° valgus. There is no significant difference in implants loosening in the three groups. Level of Evidence III, Retrospective Comparative Study.


RESUMO Objetivo: Realizar um estudo comparativo observando a análise clínica e radiográfica das próteses primárias do tipo TC3 Johnson ® com ou sem haste durante um seguimento de curto prazo. Métodos: A amostra foi dividida em três grupos: Grupo 1 com haste, Grupo 2 sem haste e Grupo 3 misto. Foi realizada a análise clínica dos pacientes e verificado se ocorreu soltura dos implantes. Resultados: As deformidades pré-operatórias foram predominantemente graves. O arco de movimento total no pós-operatório foi acima de 96,7° nos três grupos. No pós-operatório o ângulo tíbio-femoral oscilou na média entre 5 e 6° de valgo. Não houve registro de soltura do implante para os casos tratados com haste; a incidência de soltura foi de 14,3% entre os casos do grupo sem haste e de 16,7% entre os casos do grupo misto. Conclusão: Em geral, as deformidades pré-operatórias foram consideradas graves. No pós-operatório a amplitude total do arco de movimento foi acima de 96,7°. O ângulo tíbio-femoral pós-operatório obteve uma média entre 5 e 6° de valgo. Não há diferença significativa na soltura dos implantes nos três grupos. Nível de Evidência III, Estudo Retrospectivo Comparativo.

7.
Arthrosc Tech ; 10(7): e1763-e1772, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34336574

RESUMEN

The key to preventing early knee osteoarthritis is meniscal preservation. The main functions of the meniscus are impact absorption, mechanical load transmission, lubrication, joint stability, and proprioception. Radial lesions that extend to the joint capsule are called complete radial tears. This type of injury compromises 2 of the main meniscal functions, which are impact absorption and load distribution, which is equivalent, from a biomechanical perspective, to a total meniscectomy. In the recent past, the treatment of choice for this type of injury was partial meniscectomy. However, several studies have observed progressive joint degeneration after this type of treatment. Recently, different types of meniscal sutures involving radial lesions of the meniscus have been developed. It is believed that such repairs may bring a decrease in future osteoarthritis in this patient profile. The purpose of this article is to describe the steps of continuous meniscal suture for the treatment of radial tears of the medial and lateral menisci.

8.
Int Orthop ; 43(9): 2065-2070, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30215100

RESUMEN

PURPOSE: To assess functional outcomes in patients undergoing total knee arthroplasty (TKA) without previous corrective osteotomy for treatment of knee osteoarthritis associated with extra-articular deformity. METHODS: From January to December 2016, patients with knee osteoarthritis with extra-articular deformities who presented for preoperative assessment before TKA were evaluated prospectively. Physical and radiological characteristics were documented pre- and postoperatively. RESULTS: TKA was performed in 33 knees; 25 were considered for analysis. The mean age was 65.2 years (range, 48-79 years). Sixteen deformities were secondary to fractures and nine to failed osteotomies. The mean Knee Society Score (KSS) improved from 27.1 pre-operatively to 68.7 post-operatively (p = 0.000). Pre-operative mechanical axis ranged from 32° varus (negative) to 26° valgus. After correction, 20 knees were within 3° (varus or valgus) of mechanical alignment. CONCLUSION: In patients with extra-articular deformities, TKA with asymmetric intra-articular resection and ligament balancing can relieve pain and realign the mechanical axis of the lower limb.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Enfermedades Óseas/cirugía , Articulación de la Rodilla/cirugía , Extremidad Inferior/cirugía , Osteoartritis de la Rodilla/cirugía , Anciano , Enfermedades Óseas/etiología , Femenino , Fracturas Óseas/complicaciones , Humanos , Ligamentos/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/complicaciones , Osteotomía/efectos adversos
9.
Eur J Orthop Surg Traumatol ; 25(6): 1013-7, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26050234

RESUMEN

OBJECTIVE: The present study aimed to evaluate whether patient education level interferes in the percentage of pain relief or increase using visual analogue scale (VAS) and subjective pain perception. PATIENTS AND METHODS: Ninety-five patients presenting acute shoulder pain due to enthesitis were evaluated. They were asked to quantify the pain using VAS before steroid articular infiltration. One week later, patients reevaluated the pain using VAS and orally stated the percentage of perceived pain increase or relief. The information gathered was then compared among three patient educational levels (elementary, high school, and university). RESULTS: Percentages of improvement stated orally and utilizing VAS presented no statistically significant differences among the three educational status levels (p = 0.804). CONCLUSION: Patient educational status caused no impact in the results of acute pain self-assessment with VAS and oral evaluation.


Asunto(s)
Dolor Agudo/diagnóstico , Autoevaluación Diagnóstica , Dolor de Hombro/diagnóstico , Dolor Agudo/prevención & control , Adulto , Anciano , Escolaridad , Femenino , Humanos , Inyecciones Intraarticulares , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Reinserción al Trabajo , Distribución por Sexo , Dolor de Hombro/prevención & control , Esteroides/administración & dosificación
10.
BMJ Case Rep ; 20152015 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-25743861

RESUMEN

Rupture of the patellar tendon is a well-known injury in the orthopaedic literature. However, it is unusual and rarely reported in adolescent children. On the one hand, in the immature skeleton, the most frequent lesion above the kneecap is the sleeve fracture. On the other hand, in the distal region, avulsion of the tibial tuberosity is more common. Patellar tendon rupture in an adolescent is a rare lesion. We report a case in which an adolescent sustained a fall when jumping. No predisposing factors have been found. The injury was treated with surgical repair with transosseous suturing and reinforcement with semitendinosus tendon. The aim of this study is to present a case of traumatic rupture of the extensor mechanism of the knee in an adolescent and the therapy used.


Asunto(s)
Fijación Interna de Fracturas , Ligamento Rotuliano/cirugía , Traumatismos de los Tendones/cirugía , Accidentes por Caídas , Adolescente , Humanos , Masculino , Ligamento Rotuliano/lesiones , Ligamento Rotuliano/fisiopatología , Rango del Movimiento Articular , Rotura , Traumatismos de los Tendones/fisiopatología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA