Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
JAMA Intern Med ; 177(3): 399-406, 2017 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-28135352

RESUMEN

Importance: The US Preventive Services Task Force recommends annual lung cancer screening (LCS) with low-dose computed tomography for current and former heavy smokers aged 55 to 80 years. There is little published experience regarding implementing this recommendation in clinical practice. Objectives: To describe organizational- and patient-level experiences with implementing an LCS program in selected Veterans Health Administration (VHA) hospitals and to estimate the number of VHA patients who may be candidates for LCS. Design, Setting, and Participants: This clinical demonstration project was conducted at 8 academic VHA hospitals among 93 033 primary care patients who were assessed on screening criteria; 2106 patients underwent LCS between July 1, 2013, and June 30, 2015. Interventions: Implementation Guide and support, full-time LCS coordinators, electronic tools, tracking database, patient education materials, and radiologic and nodule follow-up guidelines. Main Outcomes and Measures: Description of implementation processes; percentages of patients who agreed to undergo LCS, had positive findings on results of low-dose computed tomographic scans (nodules to be tracked or suspicious findings), were found to have lung cancer, or had incidental findings; and estimated number of VHA patients who met the criteria for LCS. Results: Of the 4246 patients who met the criteria for LCS, 2452 (57.7%) agreed to undergo screening and 2106 (2028 men and 78 women; mean [SD] age, 64.9 [5.1] years) underwent LCS. Wide variation in processes and patient experiences occurred among the 8 sites. Of the 2106 patients screened, 1257 (59.7%) had nodules; 1184 of these patients (56.2%) required tracking, 42 (2.0%) required further evaluation but the findings were not cancer, and 31 (1.5%) had lung cancer. A variety of incidental findings, such as emphysema, other pulmonary abnormalities, and coronary artery calcification, were noted on the scans of 857 patients (40.7%). Conclusions and Relevance: It is estimated that nearly 900 000 of a population of 6.7 million VHA patients met the criteria for LCS. Implementation of LCS in the VHA will likely lead to large numbers of patients eligible for LCS and will require substantial clinical effort for both patients and staff.


Asunto(s)
Detección Precoz del Cáncer/métodos , Neoplasias Pulmonares , Servicios Preventivos de Salud , Anciano , Determinación de la Elegibilidad , Femenino , Humanos , Hallazgos Incidentales , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/epidemiología , Masculino , Persona de Mediana Edad , Innovación Organizacional , Medición de Resultados Informados por el Paciente , Selección de Paciente , Servicios Preventivos de Salud/métodos , Servicios Preventivos de Salud/organización & administración , Servicios Preventivos de Salud/normas , Atención Primaria de Salud/métodos , Atención Primaria de Salud/organización & administración , Evaluación de Programas y Proyectos de Salud , Mejoramiento de la Calidad , Tomografía Computarizada por Rayos X/métodos , Estados Unidos/epidemiología , Salud de los Veteranos/estadística & datos numéricos
2.
J Gen Intern Med ; 31 Suppl 1: 53-60, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26951277

RESUMEN

BACKGROUND: Most existing performance measures focus on underuse of care, but there is growing interest in identifying and reducing overuse. OBJECTIVE: We aimed to develop a valid and reliable electronic performance measure of overuse of screening colonoscopy in the Veterans Affairs Health Care System (VA), and to quantify overuse in VA. DESIGN: This was a cross-sectional study with multiple cross-sections. SUBJECTS: U.S. Veterans who underwent screening colonoscopy between 2011 and 2013. MAIN MEASURES: Overuse of screening colonoscopy, using a validated electronic measure developed by an expert workgroup. KEY RESULTS: Compared to results obtained from manual record review, the electronic measure was highly specific (97 %) for overuse, but not sensitive (20 %). After exclusion of diagnostic and high-risk screening or surveillance procedures, the validated electronic measure identified 88,754 average-risk screening colonoscopies performed in VA during 2013. Of these, 20,530 (23 %) met the definition for probable (17 %) or possible (6 %) overuse. Substantial variation in colonoscopy overuse was noted between Veterans Integrated Care Networks (VISNs) and between facilities, with a nearly twofold difference between the maximum and minimum rates of overuse at the VISN level and a nearly eightfold difference at the facility level. Overuse at the VISN and facility level was relatively stable over time. CONCLUSIONS: Overuse of screening colonoscopy can be measured reliably and with high specificity using electronic data, and is common in a large integrated healthcare system. Overuse measures, such as those we have specified through a consensus workgroup process, could be combined with underuse measures to improve the appropriateness of colorectal cancer screening.


Asunto(s)
Colonoscopía/tendencias , Prestación Integrada de Atención de Salud/tendencias , Detección Precoz del Cáncer/tendencias , Registros Electrónicos de Salud/tendencias , United States Department of Veterans Affairs/tendencias , Salud de los Veteranos/tendencias , Adulto , Anciano , Anciano de 80 o más Años , Colonoscopía/métodos , Estudios Transversales , Prestación Integrada de Atención de Salud/métodos , Detección Precoz del Cáncer/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA