Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Idioma
Intervalo de año de publicación
1.
Biofizika ; 59(6): 1101-7, 2014.
Artículo en Ruso | MEDLINE | ID: mdl-25715616

RESUMEN

Blood lymphocytes of children with oncology diseases were studied in smears compared with healthy ones examined from the closely selected group. The following two methods were used: the traditional in hematology method of smear staining for detection of blood formula and lymphocyte indices and the staining with novel cytobiochemical method including 60-min incubation in biochemical medium for estimation of the activity of succinate dehydrogenase, lactate dehydrogenase and their ratio, that can serve as a measure of respiration and glycolysis--Warburg effect, typical of tumor. The great increase in lymphocyte size by addition of lactate was found in blood smears of patients with tumors. This effect was not pronounced by addition of succinate and in cells of healthy persons. Changes in the structure of the cells in patients were also related to the changes in the activity of enzymes studied. These changes can be considered as transition of metabolism and the structure of cells to the state in tumor. Cytobiochemical method allows for higher diagnostic sensitivity of patient examination and efficiency of medical care of patients with oncological diseases.


Asunto(s)
Glucólisis/efectos de los fármacos , Hidroliasas/metabolismo , Ácido Láctico/farmacología , Linfocitos/enzimología , Consumo de Oxígeno/efectos de los fármacos , Succinato Deshidrogenasa/metabolismo , Ácido Succínico/farmacología , Niño , Preescolar , Femenino , Humanos , Linfocitos/patología , Masculino , Neoplasias/metabolismo , Neoplasias/patología , Adulto Joven
2.
Klin Lab Diagn ; (10): 22-4, 33-9, 2006 Oct.
Artículo en Ruso | MEDLINE | ID: mdl-17144542

RESUMEN

The paper presents the results of medical tests of a group of computer-aided procedures for microscopic analysis by means of a MECOS-Ts2 complex (ZAO "MECOS", Russia), which have been conducted at the Republican Children's Clinical Hospital, the Research Institute of Emergency Pediatric Surgery and Traumatology, and Moscow City Clinical Hospital No. 23. Computer-aided procedures for calculating the differential count and for analyzing the morphology of red blood cells were tested on blood smears from a total of 443 patients and donors, computer-aided calculation of the count of reticulocytes was tested on 318 smears. The tests were carried out under the US standard NCCLS-H20A. Manual microscopy (443 smears) and flow blood analysis on a Coulter GEN*S (125 smears) were used as reference methods. The quality of collection of samples and laboriousness were additionally assessed. The certified MECOS-Ts2 subsystems were additionally used as reference tools. The tests indicated the advantage of computer-aided MECOS-Tsl2 complex microscopy over manual microscopy.


Asunto(s)
Pruebas Hematológicas/instrumentación , Adolescente , Adulto , Anciano , Autoanálisis , Recuento de Células Sanguíneas , Niño , Preescolar , Humanos , Microscopía , Persona de Mediana Edad , Telemedicina/instrumentación
4.
Klin Lab Diagn ; (6): 39-42, 2003 Jun.
Artículo en Ruso | MEDLINE | ID: mdl-12910642

RESUMEN

Measurements of the form and size of erythrocytes are needed in the diagnosis of a number of diseases. However, such measurements, if made manually, are a labor-consuming and often inaccurate method, which ensures the determination of a very limited number of parameters. Hardware/software unit MEKOS-C1 enables an automated examination of blood smear, thus speeding up significantly the analysis and ensuring a more complete and accurate information. The possibilities of unit MEKOS-C1 were evaluated for the diagnosis of ovalocytosis. Blood smears of 19 patients from the Russian Pediatric Clinical Hospital, including 8 patients with inherited ovalocytosis, 1 patient with spherocytic ovalocytosis and 10 patients without the disease, were made use of Erythrocytes were isolated in the images of preparations and the contour of each cell was approximated by ellipse. The ratio between ellipse semi-axes served as a measure of erythrocytes' ovality. The mean ratio of semi-axes (RS) and the index of ovalocytosis (IO), i.e. a ratio of the mean maximum diameter to the mean minimal diameter, were calculated for each smear. Manual IO measurements were made in all preparations as a control. Since an additional error can enter the result because of the irregular smear nature and impossibility to standardize completely the technology of smear preparation, the data, obtained from two different smear parts and from parallel preparations, were compared. The reliability, stability and good reproducibility of the automated measurement results were demonstrated. The mean erythrocytes' RS correlated well with IO, obtained manually, and did not virtually differ from RS, measured in the automated manner. The mean RS value of erythrocytes, obtained from patients with inherited ovalocytosis, significantly differed from the control values, which is indicative of a high information density of the discussed parameter. Therefore, RS, when measured automatically, is a reliable and convenient characteristic of erythrocytes' ovality under the conditions of using the ordinary technique of smear preparation.


Asunto(s)
Técnicas Citológicas/instrumentación , Eliptocitosis Hereditaria/sangre , Eritrocitos/patología , Pruebas Hematológicas/instrumentación , Microscopía/instrumentación , Adolescente , Autoanálisis , Tamaño de la Célula , Niño , Femenino , Humanos , Masculino , Robótica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA