Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Card Surg ; 33(11): 759-761, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30259583

RESUMEN

We present two patients who required extracorporeal membrane oxygenation (ECMO) support after bioprosthetic mitral valve replacement, who developed early structural valve failure due to leaflet fusion. Percutaneous balloon valvuloplasty restored normal leaflet motion and allowed discontinuation of ECMO support.


Asunto(s)
Bioprótesis/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Mitral/métodos , Válvula Mitral/cirugía , Falla de Prótesis/etiología , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Resultado del Tratamiento
2.
Soud Lek ; 60(4): 57-65, 2015.
Artículo en Checo | MEDLINE | ID: mdl-26585307

RESUMEN

The bloodstain pattern analysis (BPA) is useful in the forensic medicine. In Czechoslovakian criminology is this method not commonly used. The objective of this work is to calculate the impact length, height and distance splashing of blood drops. The results are compared with the real values for specific cases. It is also compared to calculate the angle of incidence of blood drops, using sinα with a form using tgα. For this purposes we used two different character cases from practice with well-preserved condition and readable blood stains. Selected blood stains were documented in order to calculate the angle of incidence of blood drops and to calculateorigin splashes. For this drop of blood, the distance of impact of the drops of blood (x), the height of the sprayed blood drops (y) and the length of the flight path the drop of blood (l). The obtained data was retrospectively analysed for the two models. The first straight line is represented by the triangle (M1) and the other is the parabolic model (M2). The formulae were derived using the Euler substitution. The results show that the angle of incidence of the drop of blood can be calculated as sinα and the tgα. When applying, the triangle is appropriate to consider the application and sinα parabolic requires the calculation of the angle of incidence drops of blood tgα. Parabola is useful for the BPA. In Czechoslovakian should be providing workplace training seminars BPA primarily intended for forensic investigators.We recommend the use of this method during investigations, verification of acts in forensic practice.


Asunto(s)
Manchas de Sangre , Medicina Legal/métodos , Humanos
3.
Soud Lek ; 58(2): 20-5, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23641723

RESUMEN

Bloodstain pattern analysis (BPA) is a valid forensic method which belongs to the category of biological methods using trigonomic models. Despite its development through the years, the method has been re-formulated a standard one and globally used, recognized in standard sheets. This method permits exact analysis of the dynamic and characteristic properties of bloodstains after impact on surfaces such as floors, walls, and ceilings, various exterior and interior items, and clothes. It is also possible to determine the characteristics of blood from the outer part of the body. According to the presence of blood and its quantity, it is also possible to use this method for verification of reconstruction of criminal acts, while being tested for its validity with primary conditions of preserved and readable traces of blood. Even though this method is not considered as the major one or the only one information obtained in this way can be used for judicial. In our research, we tested the validity of this method in an experimental model using firearms. We compared measurements of the lengths of trajectory of impact and the height of the blood sprayed upwards from a distance of 1, 3, 5 and 10 meters. The experiment was based on two main presumptions. The first was the knowledge of the value of the distance and the angle of impact of the bloodstain, the second, the ability of the blood to reach a certain height and the angle of its impact. In accordance with trigonometric formulas, both the impact of the selected distance of drops of blood, and the height of the selected bloodstain could be determined without any verification of the flight trajectory and the distance of bloodstains. The results indicate that the method for these requirements differs from the real values, while increasing the measurements with the indicated spot of the shot. Aside from the unique values which were calculated, other results of the impact of the distance of drops of bloodstain were considered of lower value, and the values concerning the height of the bloods stains after the shot higher than real values. In spite of the lack of total accuracy, we recommend using this method widely and more often for investigation and verification of individual acts in criminal and forensic practice.


Asunto(s)
Manchas de Sangre , Balística Forense , Animales , Bovinos , Medicina Legal/métodos , Técnicas In Vitro , Matemática
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA