Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 29
1.
Vet J ; 293: 105966, 2023 Mar.
Article En | MEDLINE | ID: mdl-36801487

Left atrial (LA) volumes using a monoplane Simpson's Method of Discs (SMOD) can be obtained from the right parasternal long axis four-chamber (RPLA) or from the left apical four-chamber (LA4C) views in dogs; however, little information exists regarding the agreement of LA volume estimates using a SMOD on images obtained from LA4C and RPLA views. Therefore, we sought to examine the agreement between the two methods of obtaining LA volumes in a heterogenous population of healthy and diseased dogs. Additionally, we compared the LA volumes obtained by SMOD with estimates obtained from simple cube or sphere volume formulae. Archived echocardiographic examinations were retrieved and, where both RPLA and LA4C views were adequately recorded, included in the study. We obtained measurements from 194 dogs that were either apparently healthy (n = 80) or had various cardiac diseases (n = 114). The LA volumes of each dog was measured using a SMOD, from both views, in systole and diastole. Estimates of LA volumes obtained from simple cube or sphere volume formulae from RPLA-derived LA diameters were also calculated. We then used Limits of Agreement analysis to determine agreement between the estimates obtained with each view, and those calculated from linear dimensions. The two methods obtained by SMOD provided similar estimates for both systolic and diastolic volumes but did not agree sufficiently to be interchangeable. The LA4C view often slightly underestimated the LA volumes at small LA sizes and overestimated the LA volumes at large LA sizes compared to RPLA method, with increasing disagreement as the LA size increased. Estimates based on cube method overestimated volumes compared to both SMOD methods, whereas those based on sphere method performed reasonably. Our study suggests that monoplane volume estimates from the RPLA and LA4C views are similar but not interchangeable. Clinicians can also perform a rough estimate of LA volumes using RPLA-derived LA diameters to calculate the sphere volume.


Dog Diseases , Heart Diseases , Dogs , Animals , Heart Atria/diagnostic imaging , Echocardiography/veterinary , Heart Diseases/veterinary , Systole , Physical Examination
2.
Vet J ; 277: 105762, 2021 Nov.
Article En | MEDLINE | ID: mdl-34655788

Echocardiographic guidance provides an alternative method when fluoroscopy is unavailable, equipment or power failure of fluoroscopic equipment during a procedure occurs or to decrease radiation risk. Recently, transthoracic (TTE) and transesophageal echocardiography were reported as an alternative method to guide interventional procedures in dogs. Therefore, we hypothesized that TTE could be used as an alternative method to visualize endocardial leads during pacemaker implantation in dogs, largely avoiding the use of fluoroscopy. A prospective consecutive case series of pacemaker implantation was performed using TTE guidance. The endocardial lead was imaged by TTE during its intracardiac advancement until the lead tip was positioned at the right ventricular apex. Echocardiographic right parasternal views, optimized to visualize the pacing lead, were used, starting with a short axis image of the right atrium and ending with a long axis view of the right ventricle (RV) optimized to image the RV apex. Proper lead placement was confirmed by both capture threshold, impedance and fluoroscopy. Twenty-one pacemaker implantation procedures by TTE monitoring were successfully performed. The TTE guidance provided images of a quality sufficient to clearly monitor implantation in real-time and allowed for immediate corrections to pacing lead malpositioning or excessive looping. Fluoroscopy was used to confirm the correct placement of the lead that was guided echocardiographically in the initial three procedures, after which a single radiographic image (no cine-mode) was used to identify lead placement and redundancy in the remaining eighteen cases. Static imaging (radiography using the fluoroscope) was used to assess the proper lead redundancy in all procedures because this cannot be evaluated echocardiographically. Pacemaker leads were successfully implanted in the RV of dogs using TTE monitoring. A larger cases series is needed for validation of safety and effectiveness of TTE during this interventional procedure in dogs.


Pacemaker, Artificial , Animals , Cardiac Pacing, Artificial/veterinary , Dogs , Echocardiography/veterinary , Fluoroscopy/veterinary , Pacemaker, Artificial/veterinary , Prospective Studies
3.
J Vet Cardiol ; 36: 77-88, 2021 Aug.
Article En | MEDLINE | ID: mdl-34118562

OBJECTIVES: To identify the predictive value on time to onset of heart failure (HF) or cardiac death of clinical, radiographic, and echocardiographic variables, as well as cardiac biomarkers N-terminal pro brain natriuretic peptide (NT-proBNP) and cardiac troponin I in dogs with preclinical myxomatous mitral valve disease (MMVD). ANIMALS: One hundred sixty-eight dogs with preclinical MMVD and left atrium to aortic root ratio ≥1.6 (LA:Ao) and normalized left ventricular end-diastolic diameter ≥1.7 were included. METHODS: Prospective, randomized, multicenter, single-blinded, placebo-controlled study. Clinical, radiographic, echocardiographic variables and plasma cardiac biomarkers concentrations were compared at different time points. Using receiving operating curves analysis, best cutoff for selected variables was identified and the risk to develop the study endpoint at six-month intervals was calculated. RESULTS: Left atrial to aortic root ratio >2.1 (hazard ratio [HR] 3.2, 95% confidence interval [95% CI] 1.9-5.6), normalized left ventricular end-diastolic diameter > 1.9 (HR: 6.3; 95% CI: 3.3-11.8), early transmitral peak velocity (E peak) > 1 m/sec (HR: 3.9; 95% CI: 2.3-6.7), and NT-proBNP > 1500 ρmol/L (HR: 5.7; 95% CI: 3.3-9.5) were associated with increased risk of HF or cardiac death. The best fit model to predict the risk to reach the endpoint was represented by the plasma NT-proBNP concentrations adjusted for LA:Ao and E peak. CONCLUSIONS: Logistic and survival models including echocardiographic variables and NT-proBNP can be used to identify dogs with preclinical MMVD at higher risk to develop HF or cardiac death.


Dog Diseases , Heart Failure , Animals , Biomarkers , Death , Dog Diseases/diagnostic imaging , Dogs , Echocardiography/veterinary , Heart Failure/diagnostic imaging , Heart Failure/veterinary , Mitral Valve/diagnostic imaging , Natriuretic Peptide, Brain , Peptide Fragments , Prospective Studies
4.
J Appl Microbiol ; 131(1): 499-512, 2021 Jul.
Article En | MEDLINE | ID: mdl-33325600

AIMS: To develop a protocol for environmental sampling to detect parvoviruses of dogs and cats in the environment. METHODS AND RESULTS: Environmental contamination was carried out using different dilutions of parvovirus-contaminated materials; further field samplings were performed in areas in which clinical cases of parvovirus infections were present. Sterile cotton swabs and sponges for microbial surface sampling were used. Viruses were detected in these samples with different methods: conventional PCR, nested PCR and real-time PCR, detecting viral DNA; virus isolation, detecting infectious virus; and a commercial rapid enzyme immunoassay, detecting viral antigen. No substantial differences were observed in the two sampling methods, although the sponge was more convenient for sampling rough surfaces. Molecular assays were the most sensitive methods, identifying even very low amounts of viral DNA (up to 10 copies of viral DNA/10 µl of sample). Virus isolation and the rapid test detected the viruses only at the highest viral concentrations, both in the experimental setting and field conditions. CONCLUSIONS: Environmental sampling and molecular protocols were effective in detecting environmental contamination with parvoviruses. SIGNIFICANCE AND IMPACT OF THE STUDY: The protocol will be useful to identify possible sources of infection and to assess the efficacy of disinfection protocols in the environment.


Cat Diseases/virology , Dog Diseases/virology , Environmental Microbiology , Parvoviridae Infections/veterinary , Parvovirus/isolation & purification , Animals , Antigens, Viral/immunology , Cats , DNA, Viral/genetics , Dogs , Enzyme-Linked Immunosorbent Assay , Parvoviridae Infections/virology , Parvovirus/genetics , Parvovirus/immunology , Polymerase Chain Reaction
5.
J Small Anim Pract ; 62(2): 150-155, 2021 02.
Article En | MEDLINE | ID: mdl-31512264

This case series describes a novel mini coeliotomy approach using a radial, atraumatic self-retaining retractor for the retrieval of migrant plant foreign bodies from the iliopsoas muscles of six male dogs under intra-operative ultrasonographic guidance. Four dogs had a history of pulmonary disease potentially compatible with inhalation of a foreign body approximately 2-4 months before presentation. Under ultrasonographic guidance, the grass awns were identified in the iliopsoas muscle and were completely removed. In this case series, the annular ring device provided an excellent view of the surgical field for intra-abdominal manipulations. Patient follow-up at 15 days and 6 to 12 months after surgery indicated a full recovery, and no grass awn fragment residues were identified.


Dog Diseases , Foreign Bodies , Foreign-Body Migration , Animals , Dog Diseases/surgery , Dogs , Foreign Bodies/diagnostic imaging , Foreign Bodies/surgery , Foreign Bodies/veterinary , Foreign-Body Migration/veterinary , Male , Poaceae , Ultrasonography
6.
J Vet Cardiol ; 27: 34-53, 2020 Feb.
Article En | MEDLINE | ID: mdl-32032923

INTRODUCTION: Efficacy of renin-angiotensin-aldosterone system (RAAS) blockade using angiotensin-converting enzyme inhibitors (ACEi) in dogs with preclinical myxomatous mitral valve disease (MMVD) is controversial. HYPOTHESIS: Administration of spironolactone (2-4 mg q 24 h) and benazepril (0.25-0.5 mg q 24 h) in dogs with preclinical MMVD, not receiving any other cardiac medications, delays the onset of heart failure (HF) and cardiac-related death. Moreover, it reduces the progression of the disease as indicated by echocardiographic parameters and level of cardiac biomarkers N-terminal pro brain natriuretic peptide (NT-proBNP) and cardiac troponin I (cTnI). ANIMALS: 184 dogs with pre-clinical MMVD and left atrium-to-aortic root ratio (LA:Ao) ≥1.6 and normalized left ventricular end-diastolic diameter (LVEDDn) ≥1.7. METHODS: This is a prospective, randomized, multicenter, single-blinded, placebo-controlled study. Primary outcome variable was time-to-onset of first occurrence of HF or cardiac death. Secondary end points included effect of treatment on progression of the disease based on echocardiographic and radiographic parameters, as well as variations of NT-proBNP and cTnI concentrations. RESULTS: The median time to primary end point was 902 days (95% confidence interval (CI) 682-not available) for the treatment group and 1139 days (95% CI 732-NA) for the control group (p = 0.45). Vertebral heart score (p = 0.05), LA:Ao (p < 0.001), LVEDDn (p < 0.001), trans-mitral E peak velocity (p = 0.011), and NT-proBNP (p = 0.037) were lower at the end of study in the treatment group. CONCLUSIONS: This study failed in demonstrating that combined administration of spironolactone and benazepril delays onset of HF in dogs with preclinical MMVD. However, such treatment induces beneficial effects on cardiac remodeling and these results could be of clinical relevance.


Benzazepines/therapeutic use , Dog Diseases/drug therapy , Heart Valve Diseases/veterinary , Spironolactone/therapeutic use , Angiotensin-Converting Enzyme Inhibitors , Animals , Dogs , Echocardiography/veterinary , Female , Heart Valve Diseases/drug therapy , Male , Mitral Valve , Natriuretic Peptide, Brain , Peptide Fragments , Prospective Studies , Troponin I
7.
J Vet Cardiol ; 27: 23-33, 2020 Feb.
Article En | MEDLINE | ID: mdl-31931390

INTRODUCTION/OBJECTIVES: Recognition of congestive heart failure (CHF) in dyspnoeic cats is crucial for correct intervention. The pulmonary vein (PV) to pulmonary artery (PA) ratio (PV/PA) has been proposed as an index that might help discriminate dogs suffering from CHF but has never been studied in cats. We sought to determine reference intervals for various PV and PA variables in healthy cats. We then examined these variables in cats with subclinical and clinical cardiomyopathies to determine their diagnostic utility in identifying CHF. ANIMALS, MATERIALS AND METHODS: We took a sample of 114 cats: 51 healthy cats, 32 subclinical cardiomyopathy affected cats and 31 cardiomyopathic cats with CHF. PV and PA were measured at the minimal and maximal diameters using M-mode images obtained from a modified right parasternal long axis view. The aorta (Ao) and left atrium were measured using two-dimensional imaging employing the right parasternal short axis view. RESULTS: median PVmin/PAmin value in healthy cats was approximately 0.51 and the PVmax/PAmax value was 0.67. The median distensibility value of the vessels was 23% for ΔPA and 41% for ΔPV. Cats with CHF had higher PVmin/PAmin, PVmax/PAmax, PVmin/Ao, PVmax/Ao values and a smaller ΔPV value compared to subclinical and healthy cats (p < 0.0001). When evaluating the diagnostic performance of these variables (in cardiomyopathic cats), PVmin/PAmin and PVmin/Ao values had higher accuracy compared to the LA:Ao value when identifying cats with CHF. CONCLUSIONS: Our study provides reference values for PV and PA variables in cats. Moreover, PV/PA variables were better factors than LA:Ao for discriminating cardiomyopathic cats with and without CHF.


Cardiomyopathies/veterinary , Cat Diseases/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Pulmonary Veins/diagnostic imaging , Animals , Cardiomyopathies/diagnostic imaging , Cat Diseases/pathology , Cats , Dyspnea/veterinary , Echocardiography/veterinary , Female , Heart Failure/diagnostic imaging , Heart Failure/veterinary , Male
8.
J Vet Cardiol ; 20(5): 354-363, 2018 Oct.
Article En | MEDLINE | ID: mdl-30145181

OBJECTIVES: To create reference intervals for right ventricular outflow tract fractional shortening (RVOT-FS) in healthy dogs and examine diagnostic performance of this index in dogs with pulmonary hypertension (PH). In addition, we examine the impact of myxomatous mitral valve disease (MMVD) without PH on RVOT-FS. ANIMALS, MATERIALS AND METHODS: The study population included 52 healthy adult dogs, 51 dogs with MMVD but without PH, and 51 dogs with PH. This is a prospective study. Complete echocardiographic evaluations were performed on all dogs. Right ventricular outflow tract fractional shortening was obtained by two-dimensional guided M-mode recordings from the right parasternal short axis view. Right ventricular outflow tract fractional shortening was evaluated in healthy dogs of various breeds, and reference intervals were generated. We examined the effect of PH on RVOT-FS with receiver operating characteristic analysis and evaluated the effect of MMVD on RVOT-FS in dogs without PH. Intraobserver and interobserver reproducibility was calculated. RESULTS: Healthy dogs had RVOT-FS > 44%. Right ventricular outflow tract fractional shortening values of healthy dogs and MMVD dogs without PH did not differ (p=0.84). In dogs with PH, RVOT-FS decreased with increasing tricuspid regurgitation velocity (p<0.0001). Pimobendan use in dogs with PH increased RVOT-FS as PH worsened. Right ventricular outflow tract fractional shortening was acquired with clinically acceptable intraobserver and interobserver reproducibility. CONCLUSIONS: Right ventricular outflow tract fractional shortening is a novel, easy applicable, and repeatable index for evaluating RV systolic function. Studies comparing this index with common echocardiographic indices used to assess RV function in dogs are needed.


Dog Diseases/physiopathology , Hypertension, Pulmonary/veterinary , Ventricular Dysfunction, Right/veterinary , Age Factors , Animals , Body Weight , Dogs , Echocardiography/veterinary , Female , Hypertension, Pulmonary/physiopathology , Male , Sex Factors , Ventricular Dysfunction, Right/physiopathology
9.
J Vet Cardiol ; 20(4): 285-293, 2018 Aug.
Article En | MEDLINE | ID: mdl-29859723

In humans, accessory pathways (APs) in an anteroseptal and midseptal position are often challenging to ablate because of their close proximity with the conduction pathways of the atrioventricular junction. The use of low-energy ablation techniques can be useful to reduce the risk of permanently damaging the atrioventricular node and the His bundle. This report describes the use of low-energy radiofrequency catheter ablation to successfully and permanently ablate anteroseptal APs in two dogs with orthodromic atrioventricular reciprocating tachycardia. In the first dog, a transient first degree atrioventricular block persisted for 30 s after radiofrequency energy delivery. In the second dog, transient paroxysmal atrioventricular conduction block was observed during the procedure but resolved within 3 days. First degree atrioventricular block was again identified 2 months later. In conclusion, anteroseptal APs can be effectively treated by low-energy radiofrequency catheter ablation with minimal and transient damage to the atrioventricular junction.


Catheter Ablation/veterinary , Dog Diseases/surgery , Tachycardia/veterinary , Ventricular Septum/surgery , Animals , Atrioventricular Block/veterinary , Dogs , Male , Tachycardia/surgery
10.
J Vet Cardiol ; 20(2): 102-114, 2018 Apr.
Article En | MEDLINE | ID: mdl-29459124

INTRODUCTION: Left atrial (LA) function can provide useful information in dogs with myxomatous mitral valve disease (MMVD). Recently, we have demonstrated the feasibility of measuring LA longitudinal deformation using speckle-tracking echocardiography (STE) to estimate LA function in healthy dogs. Whether LA strain and strain rate variables provide additional information about LA function and clinical cardiac status in dogs with MMVD remains unexplored. ANIMALS: Ninety-six client-owned dogs of different breeds with MMVD were prospectively enrolled. METHODS: LA longitudinal deformation was evaluated in each dog by STE and different STE variables were used to assess LA function. RESULTS: No STE variables differed between American College of Veterinary Internal Medicine Stage B1 and B2 dogs but were lower in Stage C dogs. Peak atrial longitudinal average strain < 27.9%, left-atrial-to-aortic ratio > 2.2 and peak atrial contraction average strain < 7.25% discriminated symptomatic MMVD dogs by receiver operating characteristic analysis with sensitivity and specificity of 100% and 100% (95% confidence interval [CI] 91-100%), 92% (95% CI 78-98%) and 98% (95% CI 87-100%), 100% (95% CI 91-100%) and 95% (95% CI 83-99%), respectively. In 12 dogs with similar left-atrial-to-aortic ratio, peak atrial longitudinal average strain and peak atrial contraction average strain differentiated dogs with subclinical disease from those with congestive heart failure (CHF). CONCLUSION: Dogs with MMVD in CHF appear to have lower LA longitudinal strain and strain rate variables compared with dogs with subclinical disease. Further studies are needed to establish if our initial findings can provide useful information for the diagnosis, treatment, and prognosis of dogs with MMVD.


Dog Diseases/diagnostic imaging , Echocardiography/veterinary , Mitral Valve Insufficiency/veterinary , Animals , Atrial Function, Left , Dogs , Heart Atria/diagnostic imaging , Heart Failure/diagnostic imaging , Heart Failure/pathology , Heart Failure/veterinary , Male , Mitral Valve/diagnostic imaging , Mitral Valve/pathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/pathology
11.
J Vet Cardiol ; 18(4): 326-335, 2016 Dec.
Article En | MEDLINE | ID: mdl-27670068

OBJECTIVES: The size of the pulmonary veins (PVs) and pulmonary arteries (PAs) changes in response to hemodynamic alterations caused by physiological events and disease. We sought to create standardized echocardiographic methods for imaging the right ostium of the pulmonary veins (RPVs) and the right pulmonary artery (RPA) using specific landmarks and timing to quantify vessel diameters and phasic changes during the cardiac cycle. ANIMALS: Fifty client-owned healthy dogs prospectively recruited. METHODS: M-mode and 2-dimensional images were obtained from modified right parasternal long and short axis views. Right ostium of the pulmonary veins and RPA measurements were timed with electrical [peak of the QRS complex (RPVQRS and RPAQRS) and end of T wave (RPVT and RPAT)] or mechanical events [RPV and RPA vessels at their respective maximal (RPVMAX; RPAMAX) and minimal (RPVMIN; RPAMIN) diameters]. Right ostium of the pulmonary veins and RPA measurements were also indexed to the aorta. RESULTS: In normal dogs regardless of the echocardiographic view or time in the cardiac cycle, the RPV/RPA ratio approximated 1.0. Mechanically timed fractional changes (distensibility indices) in RPV and RPA diameters did not differ (p=0.99; 36.9% and 36.8%, respectively). ECG-timed fractional changes (distensibility indices) in RPV and RPA diameter were at least 50% smaller than mechanically timed changes (p<0.05). RPV:Ao and RPA:Ao ranged between 0.3 and 0.6, with lower values obtained in diastole and larger values in systole (p<0.0001). Multiple positive and negative deflections were identified on the RPV and RPA M-mode tracings. CONCLUSION: This study provides detailed methodology and 2D and M-mode reference intervals for the RPV and RPA dimensions and the phasic changes during the cardiac cycle of the dog using echocardiography.


Dogs/anatomy & histology , Echocardiography/veterinary , Pulmonary Artery/anatomy & histology , Pulmonary Veins/anatomy & histology , Animals , Echocardiography/methods , Female , Male , Prospective Studies , Reference Values
12.
J Vet Cardiol ; 18(4): 385-390, 2016 Dec.
Article En | MEDLINE | ID: mdl-27524307

Balloon dilation was performed in two Rottweiler puppies with cor triatriatum dexter and clinical signs of ascites using transthoracic echocardiographic guidance. The dogs were positioned on a standard echocardiography table in right lateral recumbency, and guide wires and balloon catheters were imaged by echocardiographic views optimized to allow visualization of the defect. The procedures were performed successfully without complications and clinical signs were resolved completely in both cases. Guide wires and balloon catheters appeared hyperechoic on transthoracic echocardiography image and could be clearly monitored and guided in real-time. These two cases demonstrate that it is possible to perform balloon catheter dilation of cor triatriatum dexter under transthoracic guidance alone.


Cardiac Catheterization/veterinary , Cor Triatriatum/veterinary , Dog Diseases/therapy , Echocardiography/veterinary , Animals , Cardiac Catheterization/methods , Cor Triatriatum/therapy , Dogs , Male
13.
J Vet Cardiol ; 18(2): 146-55, 2016 Jun.
Article En | MEDLINE | ID: mdl-26993761

INTRODUCTION: Feasibility, intra- and inter-observer variability of measuring left atrial (LA) longitudinal strain and strain rate (SR) variables using speckle tracking echocardiography (STE) have not been reported in the dog. Reference intervals for these variables which can be useful to estimate LA function have been provided. ANIMALS: Forty-eight healthy adult dogs. MATERIALS AND METHODS: Left atrial longitudinal deformation was evaluated in each dog by STE, and different combinations of STE variables were used to describe the 3 phases (reservoir, conduit and booster pump phase) of the LA function. RESULTS: Left atrial STE was possible in 40/48 dogs (83%). Strain and SR curves in healthy dogs were characterized, and reference intervals for several strain and SR variables are provided. Intra- and inter-observer variability, expressed as percent difference between observations or observers, was 3.58%-10.8% for indices of the LA reservoir function, 10.48%-15.82% for indices of the LA conduit function and 14.1%-34% for indices of the LA contractile function. Strain rate in early diastole and strain rate at atrial contraction variables were correlated significantly with age. No other relationships (body weight, heart rate or LA size) with any STE variables could be identified. CONCLUSION: Speckle tracking echocardiography provides quantitative measurements of LA longitudinal deformation and can be used to assess LA phasic function in healthy dogs. Further studies of these variables in dogs with cardiac diseases are needed to determine the clinical applicability and utility.


Atrial Function, Left , Dogs/anatomy & histology , Echocardiography/veterinary , Heart Atria/diagnostic imaging , Animals , Feasibility Studies , Female , Male , Observer Variation , Reference Values
14.
Vet J ; 207: 164-168, 2016 Jan.
Article En | MEDLINE | ID: mdl-26639825

Sleeping and resting respiratory rates (SRR and RRR, respectively) are commonly used to monitor dogs and cats with left-sided cardiac disease and to identify animals with left-sided congestive heart failure (L-CHF). Dogs and cats with subclinical heart disease have SRRmean values <30 breaths/min. However, little is known about SRR and RRR in dogs and cats with CHF that is well controlled with medical therapy. In this study, SRR and RRR were measured by the owners of 51 dogs and 22 cats with stable, well-controlled CHF. Median canine SRRmean was 20 breaths/min (7-39 breaths/min); eight dogs were ≥25 breaths/min and one dog only was ≥30 breaths/min. Canine SRRmean was unrelated to pulmonary hypertension or diuretic dose. Median feline SRRmean was 20 breaths/min (13-31 breaths/min); four cats were ≥25 breaths/min and only one cat was ≥30 breaths/min. Feline SRRmean was unrelated to diuretic dose. SRR remained stable during collection in both species with little day-to-day variability. The median canine RRRmean was 24 breaths/min (12-44 breaths/min), 17 were ≥25 breaths/min, seven were ≥30 breaths/min, two were >40 breaths/min. Median feline RRRmean was 24 breaths/min (15-45 breaths/min); five cats had RRRmean ≥25 breaths/min; one had ≥30 breaths/min, and two had ≥40 breaths/min. These data suggest that most dogs and cats with CHF that is medically well-controlled and stable have SRRmean and RRRmean <30 breaths/min at home. Clinicians can use these data to help determine how best to control CHF in dogs and cats.


Cat Diseases/physiopathology , Dog Diseases/physiopathology , Heart Failure/veterinary , Animals , Cats , Dogs , Echocardiography/veterinary , Female , Heart Failure/physiopathology , Male , Prospective Studies , Respiratory Rate , Rest , Sleep
15.
J Small Anim Pract ; 55(11): 545-50, 2014 Nov.
Article En | MEDLINE | ID: mdl-25213440

OBJECTIVES: To determine whether murmur intensity in small-breed dogs with myxomatous mitral valve disease reflects clinical and echocardiographic disease severity. METHODS: Retrospective multi-investigator study. Records of adult dogs Ä20 kg with myxomatous mitral valve disease were examined. Murmur intensity and location were recorded and compared with echocardiographic variables and functional disease status. Murmur intensities in consecutive categories were compared for prevalences of congestive heart failure, pulmonary hypertension and cardiac remodelling. RESULTS: 578 dogs [107 with "soft" (30 Grade I/VI and 77 II/VI), 161 with "moderate" (Grade III/VI), 160 with "loud" (Grade IV/VI) and 150 with "thrilling" (Grade V/VI or VI/VI) murmurs] were studied. No dogs with soft murmurs had congestive heart failure, and 90% had no remodelling. However, 56% of dogs with "moderate", 29% of dogs with "loud" and 8% of dogs with "thrilling" murmurs and subclinical myxomatous mitral valve disease also had no remodelling. Probability of a dog having congestive heart failure or pulmonary hypertension increased with increasing murmur intensity. CLINICAL SIGNIFICANCE: A 4-level murmur grading scheme separated clinically meaningful outcomes in small-breed dogs with myxomatous mitral valve disease. Soft murmurs in small-breed dogs are strongly indicative of subclinical heart disease. Thrilling murmurs are associated with more severe disease. Other murmurs are less informative on an individual basis.


Dog Diseases/diagnostic imaging , Heart Murmurs/veterinary , Mitral Valve Insufficiency/veterinary , Animals , Atrial Remodeling , Dogs , Echocardiography/veterinary , Female , Heart Murmurs/diagnostic imaging , Heart Murmurs/etiology , Hypertension, Pulmonary/diagnostic imaging , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/veterinary , Male , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Retrospective Studies , Severity of Illness Index
16.
J Vet Intern Med ; 28(5): 1504-12, 2014.
Article En | MEDLINE | ID: mdl-25041218

BACKGROUND: Transcatheter occlusion of patent ductus arteriosus (PDA) is usually performed by fluoroscopy alone or together with transesophageal echocardiography (TEE). Transthoracic echocardiography (TTE) guidance has been used for deployment of Amplatz Canine Ductal Occluder (ACDO), but sometimes is limited by suboptimal acoustic windows. Transesophageal echocardiography can overcome such issues and provides higher image resolution at the level of the great vessels. OBJECTIVES: To determine if TEE without fluoroscopy could be used to successfully perform ductal occlusion for the treatment of PDA in dogs. ANIMALS: Twenty client-owned dogs with PDA. METHODS: A prospective consecutive case series of PDA occlusion was performed using only TEE guidance. Dogs were positioned in right lateral recumbency and the TEE probe was positioned to visualize the descending aorta, PDA, and pulmonary artery. The guide wire, long introducer sheath, and ACDO were imaged by TEE to direct deployment. RESULTS: Ductal occlusion was performed successfully without need for fluoroscopy and without complications in 19 dogs. One dog required a second larger ACDO because of embolization of the first device 18 hours after positioning. CONCLUSIONS AND CLINICAL IMPORTANCE: We have demonstrated that TEE monitoring without concurrent fluoroscopy can guide each step of transcatheter ACDO embolization thereby providing an alternate method of visualization for this procedure. Use of TEE alone can reduce radiation exposure or is an option when fluoroscopy is not available, and, therefore, should be evaluated in a larger case series to better assess procedural failure rates.


Catheter Ablation/veterinary , Dog Diseases/diagnostic imaging , Ductus Arteriosus, Patent/veterinary , Echocardiography, Transesophageal/veterinary , Animals , Dog Diseases/surgery , Dogs , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Female , Male , Ultrasonography, Interventional/methods , Ultrasonography, Interventional/veterinary
17.
J Vet Intern Med ; 27(2): 275-85, 2013.
Article En | MEDLINE | ID: mdl-23323744

BACKGROUND: Two mutations in the MYBPC3 gene have been identified in Maine Coon (MCO) and Ragdoll (RD) cats with hypertrophic cardiomyopathy (HCM). OBJECTIVE: This study examined the frequency of these mutations and of the A74T polymorphism to describe their worldwide distribution and correlation with echocardiography. ANIMALS: 1855 cats representing 28 breeds and random-bred cats worldwide, of which 446 underwent echocardiographic examination. METHODS: This is a prospective cross-sectional study. Polymorphisms were genotyped by Illumina VeraCode GoldenGate or by direct sequencing. The disease status was defined by echocardiography according to established guidelines. Odds ratios for the joint probability of having HCM and the alleles were calculated by meta-analysis. Functional analysis was simulated. RESULTS: The MYBPC3 A31P and R820W were restricted to MCO and RD, respectively. Both purebred and random-bred cats had HCM and the incidence increased with age. The A74T polymorphism was not associated with any phenotype. HCM was most prevalent in MCO homozygote for the A31P mutation and the penetrance increased with age. The penetrance of the heterozygote genotype was lower (0.08) compared with the P/P genotype (0.58) in MCO. CONCLUSIONS AND CLINICAL IMPORTANCE: A31P mutation occurs frequently in MCO cats. The high incidence of HCM in homozygotes for the mutation supports the causal nature of the A31P mutation. Penetrance is incomplete for heterozygotes at A31P locus, at least at a young age. The A74T variant does not appear to be correlated with HCM.


Cardiomyopathy, Hypertrophic/veterinary , Carrier Proteins/genetics , Cat Diseases/genetics , DNA/genetics , Alleles , Animals , Cardiomyopathy, Hypertrophic/diagnostic imaging , Cardiomyopathy, Hypertrophic/genetics , Cat Diseases/diagnostic imaging , Cats , Cross-Sectional Studies , DNA/chemistry , Echocardiography/veterinary , Female , Genetic Predisposition to Disease , Genetic Variation , Genotype , Male , Odds Ratio , Polymerase Chain Reaction/veterinary , Polymorphism, Single Nucleotide , Prospective Studies , Sex Factors
18.
Res Vet Sci ; 93(2): 965-9, 2012 Oct.
Article En | MEDLINE | ID: mdl-22240295

Respiratory rate monitoring of cardiac patients is recommended by many cardiologists. However, little objective data exist about respiratory rates in apparently healthy dogs when collected in the home environment. We measured sleeping respiratory rates (SRR) in apparently healthy dogs and compared sleeping and resting respiratory rates (RRR) with a cross-sectional prospective study. Participants collected 12-14 one-minute SRR over a period ranging from 1 week to 2 months on 114 privately owned adult dogs. Selected participants simultaneously collected RRR. Mean within-dog average SRR (SRR(mean)) was 13breaths per minute (breaths/min). No dog had SRR(mean) >23 breaths/min; three dogs had instantaneous SRR measurements >30 breaths/min. Dogs had higher RRR(mean) (19 breaths/min) than SRR(mean) (15 breaths/min) (P<0.05). Canine SRR(mean) was unaffected by age, bodyweight or geographic location. Data acquisition was considered relatively simple by most participants. This study shows that apparently healthy adult dogs generally have SRR(mean) <30 breaths/min and rarely exceed this rate at any time.


Dogs/physiology , Respiratory Physiological Phenomena , Sleep/physiology , Animals , Body Weight , Female , Male
19.
Vet Res Commun ; 34 Suppl 1: S97-101, 2010 Jun.
Article En | MEDLINE | ID: mdl-20461463

The term monoclonal gammopathy (MG) suggests the presence of clonal immunoglobulins in blood serum that are recognized as narrow spikes in the beta and/or gamma region of the electrophoretic pattern of serum. In the dog, MG is rare and is associated with a heterogeneous group of diseases that include multiple myeloma (the most common source of MG) as well as infectious and chronic inflammatory diseases such as Leishmaniasis. In this paper, two cases of MG are described: the first case is associated with multiple myeloma of monoclonal component type IgA/lambda, with the latter rare in dogs, and the second case involves MG that developed 3 years after an initial diagnosis of Leishmaniasis.


Dog Diseases/etiology , Leishmaniasis, Visceral/veterinary , Multiple Myeloma/veterinary , Paraproteinemias/veterinary , Animals , Dogs , Female , Immunoglobulin A/blood , Immunoglobulin A/classification , Immunoglobulin A/isolation & purification , Male , Multiple Myeloma/complications , Paraproteinemias/complications
20.
Aust Vet J ; 86(10): 390-4, 2008 Oct.
Article En | MEDLINE | ID: mdl-18826510

OBJECTIVE: To determine if dogs and cats with renal failure, or other severe non-cardiac disease, and no antemortem evidence of cardiac disease on basic clinical evaluation, have elevated levels of cardiac troponin I (cTnI). DESIGN: Cross-sectional study using 56 dogs and 14 cats with primary non-cardiac disease (39 dogs with azotaemic renal failure, 14 cats with azotaemic renal failure, 17 dogs with non-cardiac systemic disease); 7/25 dogs and 6/14 cats had murmurs detected on physical examination. Serum or heparinised plasma was collected and analysed for cTnI. RESULTS: Cardiac troponin I concentrations were elevated above reference intervals in 70% of dogs and 70% of cats with azotaemic renal failure and in 70% of dogs with a variety of systemic non-cardiac diseases. Cardiac troponin I concentrations did not correlate with the degree of azotaemia, presence of murmurs, hypertension or type of non-cardiac illness. CONCLUSIONS: Cardiac troponin I concentration is often elevated in dogs and cats with azotaemic renal failure and in dogs with other systemic non-cardiac illness, suggesting that these conditions often result in clinically inapparent myocardial injury or possibly altered elimination of cTnI.


Azotemia/veterinary , Cat Diseases/blood , Dog Diseases/blood , Renal Insufficiency/veterinary , Troponin I/blood , Animals , Azotemia/blood , Azotemia/pathology , Biomarkers/blood , Cat Diseases/pathology , Cats , Dog Diseases/pathology , Dogs , Female , Male , Myocardial Infarction/blood , Myocardial Infarction/pathology , Myocardial Infarction/veterinary , Myocardium/metabolism , Myocardium/pathology , Renal Insufficiency/blood , Renal Insufficiency/pathology
...