Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Child Orthop ; 17(2): 97-104, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37034193

RESUMEN

Purpose: This study evaluated and quantified femoral anteversion and femoral head sphericity in healthy and dysplastic hips of post-mortem infant specimens from Ortolani's collection. Methods: Healthy hips and hips with cases of dysplasia, with a large variety of severity, were preserved. Morphological measurements were taken on 14 specimens (28 hips), with a mean age of 4.68 months. The degree of dysplasia was classified as mild (A) to severe (D); 11 hips were Grade A, 6 hips were Grade B, 7 hips were Grade C, and 4 hips were Grade D. The femoral anteversion angle, the minimum femoral head diameter, and the maximum femoral head diameter were measured. The minimum and maximum femoral head diameters were used to estimate femoral head sphericity. Results: The mean femoral anteversion angle was 30.81 degrees ± 11.07 degrees in cases and 29.69 degrees ± 12.69 degrees in controls. There were no significant differences between the normal-to-mild group and moderate-to-severe group when comparing the femoral anteversion angle (p = 0.836). The mean estimated sphericity was 1.08 mm ± 0.50 mm in cases and 0.81 mm ± 0.65 mm in controls, with no statistically significant difference between the groups (p = 0.269). Conclusion: Ortolani's collection showed no significant differences between healthy and dysplastic hips in specimens under 1 year of age. While the femoral head appeared slightly more flattened in dysplastic hips, it was not statistically significant. The findings in the unique collection add to the knowledge of the pathoanatomy of infantile hip dysplasia. Clinical Relevance: Femoral anteversion may not play a role in the etiology and pathogenesis of DDH.

2.
J Pediatr Orthop ; 42(1): e59-e64, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34889834

RESUMEN

BACKGROUND: Avascular necrosis (AVN) of the femoral head is a concerning complication that can result from treatments for developmental dysplasia of the hip (DDH). AVN can lead to degenerative osteoarthritis, persistent acetabular dysplasia, reduced function, and continuing hip pain. The incidence of AVN reported in the DDH literature is widely varied (0% to 73%). This variability may arise from lack of consensus on what constitutes true AVN in this patient population, and lack of clear criteria provided in studies reporting incidence rates. METHODS: A multicentre, prospective database of infants diagnosed with DDH between 2010 and 2014 from 0 to 18 months of age was analyzed for patients treated by closed reduction (CR). Twelve pediatric orthopaedic surgeons completed 2 rounds of AVN assessments. Deidentified anteroposterior radiographs at most recent follow-up were provided to surgeons along with patient age at radiographic assessment, length of follow-up, ands affected hip. Ten of 12 surgeons completed a third round of assessments where they were provided with 1 to 2 additional radiographs within the follow-up period. Radiographic criteria for total AVN described by Salter and colleagues were used. Surgeons rated the presence of AVN as "yes" or "no" and kappa values were calculated within and between rounds. RESULTS: A total of 69 hips in 60 patients were assessed for AVN a median of 22 months (range: 12 to 36) post-CR. Interobserver kappa values for rounds 1, 2, and 3 were 0.52 (range: 0.11 to 0.90), 0.61 (range: 0.21 to 0.90), and 0.53 (range: 0.10 to 0.79), respectively. Intraobserver agreement for AVN diagnosis was an average of 0.72 (range: 0.31 to 0.96). CONCLUSIONS: Despite using the most commonly referenced diagnostic criteria, radiographic diagnosis of AVN following CR in DDH patients demonstrated only moderate agreement across surgeons. The addition of sequential radiographs did not improve cross-observer reliability, and while substantial agreement was seen within observers, the range of intraobserver kappa values was large. LEVEL OF EVIDENCE: Level I-diagnostic study.


Asunto(s)
Displasia del Desarrollo de la Cadera , Necrosis de la Cabeza Femoral , Luxación de la Cadera , Niño , Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/epidemiología , Necrosis de la Cabeza Femoral/etiología , Luxación de la Cadera/diagnóstico por imagen , Luxación de la Cadera/epidemiología , Luxación de la Cadera/etiología , Humanos , Lactante , Reproducibilidad de los Resultados
3.
4.
J Pediatr Orthop ; 39(9): 453-457, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31503230

RESUMEN

BACKGROUND: Although ultrasound (US) is frequently used in diagnosis and management of infantile developmental dysplasia of the hip, precise ultrasonographic parameters of what constitutes a dislocation, subluxation etc remain poorly defined. The purpose of this study was (1) to describe the ultrasonographic characteristics of a large cohort of clinically dislocated but reducible hips and (2) to begin to develop ultrasonographic definitions for what constitutes a hip dislocation. METHODS: A retrospective review of prospectively collected data from an international multicenter study group on developmental dysplasia of the hip was conducted on all patients under 6 months of age with hip(s) that were dislocated at rest but reducible based on initial physical examination (ie, Ortolani positive). Femoral head coverage (FHC), alpha angle (α), and beta angle (ß) were measured on pretreatment US by the individual treating surgeon, and were recorded directly into the database. RESULTS: Based on 325 Ortolani positive hips, the median FHC on presentation was 10% with an interquartile range of 0% to 23%. A total of 126 of the 327 hips (39%) demonstrated 0% FHC. The 90th percentile was found to be at 33% FHC. Of 264 hips with sufficient α data, the median α was 43 degrees with an interquartile range from 37 to 49 degrees. The 90th percentile for α was at 54 degrees. A total of 164 hips had documented ß with a median of 66 degrees and an interquartile range of 57 to 79 degrees; the 90th percentile was at 94 degrees. CONCLUSIONS: Analysis of a large cohort of patients with dislocated but reducible hips reveals a median percent FHC of 10%, a median α of 43 degrees, and a median ß of 66 degrees on initial US. Using a threshold at the 90th percentile, a sensible ultrasonographic definition of a dislocated hip seems to be FHC≤33%, implying that FHC between 34% and 50% may be reasonably termed a subluxation. Although these findings are consistent with previous, smaller reports, further prospective research is necessary to validate these thresholds. LEVEL OF EVIDENCE: Level IV-diagnostic study.


Asunto(s)
Cabeza Femoral/diagnóstico por imagen , Luxación Congénita de la Cadera/diagnóstico por imagen , Ultrasonografía , Femenino , Luxación Congénita de la Cadera/terapia , Humanos , Lactante , Masculino , Examen Físico , Estudios Retrospectivos
5.
J Pediatr Orthop ; 39(3): 111-118, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30730414

RESUMEN

BACKGROUND: Closed reduction (CR) is a common treatment for infantile developmental dysplasia of the hip. The purpose of this observational, prospective, multicenter study was to determine the early outcomes following CR. METHODS: Prospectively collected data from an international multicenter study group was analyzed for patients treated from 2010 to 2014. Baseline demographics, clinical exam, radiographic/ultrasonographic data, and history of previous orthotic treatment were assessed. At minimum 1-year follow-up, failure was defined as an IHDI grade 3 or 4 hip and/or need for open reduction. The incidence of avascular necrosis (AVN), residual dysplasia, and need for further surgery was assessed. RESULTS: A total of 78 patients undergoing CR for 87 hips were evaluated with a median age at initial reduction of 8 months (range, 1 to 20 mo). Of these, 8 hips (9%) were unable to be closed reduced initially. At most recent follow-up (median 22 mo; range, 12 to 36 mo), 72/79 initially successful CRs (91%) remained stable. The likelihood of failure was unaffected by initial clinical reducibility of the hip (P=0.434), age at initial CR (P=0.897), or previous treatment in brace (P=0.222). Excluding those hips that failed initial CR, 18/72 hips (25%) developed AVN, and the risk of osteonecrosis was unaffected by prereduction reducibility of the hip (P=0.586), age at CR (P=0.745), presence of an ossific nucleus (P=0.496), or previous treatment in brace (P=0.662). Mean acetabular index on most recent radiographs was 25 degrees (±6 degrees), and was also unaffected by any of the above variables. During the follow-up period, 8/72 successfully closed reduced hips (11%) underwent acetabular and/or femoral osteotomy for residual dysplasia. CONCLUSIONS: Following an initially successful CR, 9% of hips failed reduction and 25% developed radiographic AVN at early-term follow-up. History of femoral head reducibility, previous orthotic bracing, and age at CR did not correlate with success or chances of developing AVN. Further follow-up of this prospective, multicenter cohort will be necessary to establish definitive success and complication rates following CR for infantile developmental dysplasia of the hip. LEVEL OF EVIDENCE: Level II-prospective observational cohort.


Asunto(s)
Necrosis de la Cabeza Femoral , Fémur , Luxación Congénita de la Cadera , Procedimientos Ortopédicos , Osteotomía , Cuidados Posteriores/métodos , Cuidados Posteriores/estadística & datos numéricos , Femenino , Fémur/anomalías , Fémur/diagnóstico por imagen , Fémur/cirugía , Necrosis de la Cabeza Femoral/epidemiología , Necrosis de la Cabeza Femoral/etiología , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/cirugía , Humanos , Incidencia , Lactante , Masculino , Procedimientos Ortopédicos/efectos adversos , Procedimientos Ortopédicos/instrumentación , Procedimientos Ortopédicos/métodos , Procedimientos Ortopédicos/estadística & datos numéricos , Osteotomía/métodos , Osteotomía/estadística & datos numéricos , Estudios Prospectivos , Radiografía/métodos , Reoperación/métodos , Reoperación/estadística & datos numéricos , Resultado del Tratamiento
6.
J Pediatr Orthop ; 39(1): e39-e43, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30212414

RESUMEN

BACKGROUND: Infants with dislocated irreducible (D/I) hips can be substantially harder to treat than infants with dislocated but reducible hips. The purpose of this study was to compare treatment methods and outcomes for infants with D/I hips in order to optimize management of this difficult patient cohort. METHODS: A multicenter prospective hip dysplasia study database was analyzed from 2010 to 2016. Infants aged below 6 months with clinically and radiologically confirmed D/I hips were included in the study. Teratological hips (syndromic/neuromuscular) were excluded. RESULTS: In total, 59 hips in 52 patients were included. All hips were clinically Ortolani negative and radiologically dislocated but irreducible on presentation and had at least 20 months of follow-up. Mean age at diagnosis was 1.9 months (range, 0.1 to 5.9 mo). There were 33 left hips, 12 right hips, and 14 bilateral hips (7 patients). In total, 48 of 59 hips were treated in Pavlik harness. The remainder were treated by alternative braces or primary closed or open reductions. Pavlik treatment was successful in 27 of 48 hips. Pavlik treatment was abandoned in 21 D/I hips, 3 due to femoral nerve palsy and the remainder due to failure to achieve reduction. There was no statistical correlation between Pavlik success and age at diagnosis (P=0.22), patient sex (P=0.61), or bilateral compared with unilateral D/I hips (P=0.07). Left hips were more likely to be successfully reduced in Pavlik harness than right hips (P=0.01). Five complications occurred: 3 patients developed femoral nerve palsy in Pavlik harness, while 2 patients developed avascular necrosis, both after failed Pavlik treatment and subsequent surgery. CONCLUSIONS: Pavlik harness treatment has been demonstrated to be a safe and sensible first-line treatment for infants with D/I hips. Left hips were more likely to be successfully reduced in Pavlik harness than right hips, but age, sex, and bilaterality were not correlated. The outcomes demonstrated from this multicentre prospective database inform management of this complex patient cohort. LEVEL OF EVIDENCE: Level II-prognostic study: less-quality prospective study.


Asunto(s)
Luxación Congénita de la Cadera/terapia , Tirantes , Femenino , Neuropatía Femoral/etiología , Neuropatía Femoral/cirugía , Necrosis de la Cabeza Femoral/etiología , Necrosis de la Cabeza Femoral/cirugía , Humanos , Lactante , Recién Nacido , Masculino , Manipulación Ortopédica , Aparatos Ortopédicos , Estudios Prospectivos
7.
Orthopedics ; 41(5): e705-e712, 2018 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-30092111

RESUMEN

Unicameral/aneurysmal bone cysts can lead to pain, fracture, and limb deformity. In this study, the authors evaluated the outcome of triphasic bone graft to treat unicameral/aneurysmal bone cysts. They retrospectively evaluated 41 immature patients from a prospectively enrolled cohort from 2 institutions treated from May 9, 2007, to November 1, 2014. Medical record review and evaluation of radiographs and computed tomography scans were performed. The authors characterized replacement of the material by normal bone or recurrent cyst at final follow-up. They recorded rates of fractures and complications after treatment. Twenty-nine patients were treated in Wisconsin, and 12 patients were treated in Florida. Average follow-up was 2.8 years. At follow-up, 13 of 41 patients had cyst recurrence. Three patients had fracture after initial treatment; 2 were treated surgically. Two of 9 patients with extraosseous bone graft had soft tissue swelling, and 1 required debridement. Complications did not differ by cyst type, location, sex, age, or use of internal fixation. For 27 patients with at least 2-year follow-up, percent fill of triphasic bone graft at initial surgery correlated with rate of recurrence at final follow-up: 15 of 27 patients with no cyst recurrence at final follow-up had a mean of 100% initial fill, and 12 of 27 with cyst recurrence at final follow-up had a mean of 90% initial fill (P=.048). Using triphasic bone graft for the treatment of unicameral/aneurysmal bone cysts, the authors observed a 7% rate of clinical recurrence (3 of 41 had fracture). Because this material has the potential to be locally inflammatory, efforts are needed to keep it within the bone. [Orthopedics. 2018; 41(5):e705-e712.].


Asunto(s)
Quistes Óseos/cirugía , Sustitutos de Huesos/administración & dosificación , Fosfatos de Calcio/administración & dosificación , Sulfato de Calcio/administración & dosificación , Adolescente , Quistes Óseos/diagnóstico por imagen , Niño , Preescolar , Femenino , Estudios de Seguimiento , Fracturas Óseas/etiología , Humanos , Lactante , Masculino , Complicaciones Posoperatorias , Recurrencia , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
8.
J Pediatr Orthop ; 38(6): 297-304, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28140383

RESUMEN

BACKGROUND: Current dogma contends that prolonged treatment of a dislocated hip in Pavlik harness beyond 3 weeks will cause "Pavlik harness disease." To our knowledge, however, no previous studies have documented objective morphologic changes to the acetabulum from continued treatment of a persistently dislocated hip. METHODS: We retrospectively reviewed a consecutive series of infants with developmental dysplasia of the hip, below 6 months old, who failed Pavlik treatment from a single, tertiary-care pediatric hospital and a multicenter, international study group. Inclusion criteria were dislocated hips confirmed by ultrasound (both initially and at Pavlik termination) and a minimum of 2 ultrasounds during harness treatment at least 3 weeks apart. As a global measure of acetabular morphology, α angle (AA) was compared between initial and final ultrasound. The final means of obtaining successful hip reduction was recorded from the medical records. RESULTS: Forty-nine hips in 38 patients were identified. Median age at Pavlik initiation was 4 weeks (range, 0 to 18 wk); median time in harness was 6 weeks (range, 3 to 14 wk). Surprisingly, a mean of 4 degrees improvement in AA (95% CI, 2-6 degrees; P=0.001) was observed between first and final ultrasound. We found no difference in AA change between those in harness 3 to 5 weeks and those with prolonged wear >5 weeks (P=0.817). There was no significant association between change in AA and time in harness (P=0.545), age at Pavlik initiation (P=0.199), clinical reducibility of the hip (P=0.202), or initial percent femoral head coverage (P=0.956). Following harness failure, 22/49 hips (45%) were successfully treated with rigid abduction bracing, 16 (33%) by closed reduction/spica casting, and 10 (20%) by open reduction; 1 hip (2%) spontaneously reduced and required no further treatment. CONCLUSIONS: On the basis of the lengths of harness treatment in our series, most hips did not exhibit negative changes in the acetabular AA in response to prolonged treatment of a dislocated hip in harness. Furthermore, 80% of hips failing Pavlik treatment were successfully reduced through closed means, indicating that subsequent treatment was not compromised. LEVEL OF EVIDENCE: Level IV-retrospective case series.


Asunto(s)
Luxación Congénita de la Cadera/terapia , Aparatos Ortopédicos , Acetábulo/diagnóstico por imagen , Tirantes , Femenino , Cabeza Femoral/diagnóstico por imagen , Luxación Congénita de la Cadera/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Factores de Tiempo , Insuficiencia del Tratamiento , Resultado del Tratamiento , Ultrasonografía
9.
J Orthop Res ; 35(8): 1799-1805, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-27764890

RESUMEN

This study utilized a computational biomechanical model and applied the least energy path principle to investigate two pathways for closed reduction of high grade infantile hip dislocation. The principle of least energy when applied to moving the femoral head from an initial to a final position considers all possible paths that connect them and identifies the path of least resistance. Clinical reports of severe hip dysplasia have concluded that reduction of the femoral head into the acetabulum may occur by a direct pathway over the posterior rim of the acetabulum when using the Pavlik harness, or by an indirect pathway with reduction through the acetabular notch when using the modified Hoffman-Daimler method. This computational study also compared the energy requirements for both pathways. The anatomical and muscular aspects of the model were derived using a combination of MRI and OpenSim data. Results of this study indicate that the path of least energy closely approximates the indirect pathway of the modified Hoffman-Daimler method. The direct pathway over the posterior rim of the acetabulum required more energy for reduction. This biomechanical analysis confirms the clinical observations of the two pathways for closed reduction of severe hip dysplasia. The path of least energy closely approximated the modified Hoffman-Daimler method. Further study of the modified Hoffman-Daimler method for reduction of severe hip dysplasia may be warranted based on this computational biomechanical analysis. © 2016 The Authors. Journal of Orthopaedic Research Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:1799-1805, 2017.


Asunto(s)
Luxación Congénita de la Cadera/terapia , Modelos Biológicos , Humanos , Recién Nacido
11.
J Bone Joint Surg Am ; 98(14): 1215-21, 2016 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-27440570

RESUMEN

BACKGROUND: The use of a brace has been shown to be an effective treatment for hip dislocation in infants; however, previous studies of such treatment have been single-center or retrospective. The purpose of the current study was to evaluate the success rate for brace use in the treatment of infant hip dislocation in an international, multicenter, prospective cohort, and to identify the variables associated with brace failure. METHODS: All dislocations were verified with use of ultrasound or radiography prior to the initiation of treatment, and patients were followed prospectively for a minimum of 18 months. Successful treatment was defined as the use of a brace that resulted in a clinically and radiographically reduced hip, without surgical intervention. The Mann-Whitney test, chi-square analysis, and Fisher exact test were used to identify risk factors for brace failure. A multivariate logistic regression model was used to determine the probability of brace failure according to the risk factors identified. RESULTS: Brace treatment was successful in 162 (79%) of the 204 dislocated hips in this series. Six variables were found to be significant risk factors for failure: developing femoral nerve palsy during brace treatment (p = 0.001), treatment with a static brace (p < 0.001), an initially irreducible hip (p < 0.001), treatment initiated after the age of 7 weeks (p = 0.005), a right hip dislocation (p = 0.006), and a Graf-IV hip (p = 0.02). Hips with no risk factors had a 3% probability of failure, whereas hips with 4 or 5 risk factors had a 100% probability of failure. CONCLUSIONS: These data provide valuable information for patient families and their providers regarding the important variables that influence successful brace treatment for dislocated hips in infants. LEVEL OF EVIDENCE: Prognostic Level I. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Tirantes , Luxación Congénita de la Cadera/terapia , Articulación de la Cadera/diagnóstico por imagen , Femenino , Luxación Congénita de la Cadera/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Masculino , Pronóstico , Estudios Prospectivos , Radiografía , Insuficiencia del Tratamiento , Resultado del Tratamiento , Ultrasonografía
12.
Clin Orthop Relat Res ; 474(5): 1138-45, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26891895

RESUMEN

BACKGROUND: Little information exists concerning the variability of presentation and differences in treatment methods for developmental dysplasia of the hip (DDH) in children < 18 months. The inherent advantages of prospective multicenter studies are well documented, but data from different centers may differ in terms of important variables such as patient demographics, diagnoses, and treatment or management decisions. The purpose of this study was to determine whether there is a difference in baseline data among the nine centers in five countries affiliated with the International Hip Dysplasia Institute to establish the need to consider the center as a key variable in multicenter studies. QUESTIONS/PURPOSES: (1) How do patient demographics differ across participating centers at presentation? (2) How do patient diagnoses (severity and laterality) differ across centers? (3) How do initial treatment approaches differ across participating centers? METHODS: A multicenter prospective hip dysplasia study database was analyzed from 2010 to April 2015. Patients younger than 6 months of age at diagnosis were included if at least one hip was completely dislocated, whereas patients between 6 and 18 months of age at diagnosis were included with any form of DDH. Participating centers (academic, urban, tertiary care hospitals) span five countries across three continents. Baseline data (patient demographics, diagnosis, swaddling history, baseline International Hip Dysplasia Institute classification, and initial treatment) were compared among all nine centers. A total of 496 patients were enrolled with site enrolment ranging from 10 to 117. The proportion of eligible patients who were enrolled and followed at the nine participating centers was 98%. Patient enrollment rates were similar across all sites, and data collection/completeness for relevant variables at initial presentation was comparable. RESULTS: In total, 83% of all patients were female (410 of 496), and the median age at presentation was 2.2 months (range, 0-18 months). Breech presentation occurred more often in younger (< 6 months) than in older (6-18 months at diagnosis) patients (30% [96 of 318] versus 9% [15 of 161]; odds ratio [OR], 4.2; 95% confidence interval [CI], 2.3-7.5; p < 0.001). The Australia site was underrepresented in breech presentation in comparison to the other centers (8% [five of 66] versus 23% [111 of 479]; OR, 0.3, 95% CI, 0.1-0.7; p = 0.034). The largest diagnostic category was < 6 months, dislocated reducible (51% [253 of 496 patients]); however, the Australia and Boston sites had more irreducible dislocations compared with the other sites (ORs, 2.1 and 1.9; 95% CIs, 1.2-3.6 and 1.1-3.4; p = 0.02 and 0.015, respectively). Bilaterality was seen less often in older compared with younger patients (8% [seven of 93] versus 26% [85 of 328]; p < 0.001). The most common diagnostic group was Grade 3 (by International Hip Dysplasia Institute classification), which included 58% (51 of 88) of all classified dislocated hips. Splintage was the primary initial treatment of choice at 80% (395 of 496), but was far more likely in younger compared with older patients (94% [309 of 328] versus 18% [17 of 93]; p < 0.001). CONCLUSIONS: With the lack of strong prognostic indicators for DDH identified to date, the center is an important variable to include as a potential predictor of treatment success or failure.


Asunto(s)
Disparidades en Atención de Salud , Luxación Congénita de la Cadera/epidemiología , Articulación de la Cadera/anomalías , Pautas de la Práctica en Medicina , Proyectos de Investigación , Factores de Edad , Australia/epidemiología , Presentación de Nalgas , Canadá/epidemiología , Distribución de Chi-Cuadrado , Femenino , Luxación Congénita de la Cadera/diagnóstico , Luxación Congénita de la Cadera/fisiopatología , Luxación Congénita de la Cadera/terapia , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Lactante , Recién Nacido , Masculino , México/epidemiología , Oportunidad Relativa , Selección de Paciente , Valor Predictivo de las Pruebas , Embarazo , Estudios Prospectivos , Radiografía , Factores de Riesgo , Tamaño de la Muestra , Índice de Severidad de la Enfermedad , Férulas (Fijadores) , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía , Reino Unido/epidemiología , Estados Unidos/epidemiología
13.
Clin Orthop Relat Res ; 474(5): 1131-7, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26728512

RESUMEN

BACKGROUND: Most infants with developmental dysplasia of the hip (DDH) are diagnosed within the first 3 months of life. However, late-presenting DDH (defined as a diagnosis after 3 months of age) does occur and often results in more complex treatment and increased long-term complications. Specific risk factors involved in late-presenting DDH are poorly understood, and clearly defining an associated set of factors will aid in screening, detection, and prevention of this condition. QUESTIONS/PURPOSES: Using a multicenter database of patients with DDH, we sought to determine whether there were differences in (1) risk factors or (2) the nature of the dislocation (laterality and joint laxity) when comparing patients with early versus late presentation. METHODS: A retrospective review of prospectively collected data from a multicenter database of patients with dislocated hips was conducted from 2010 to 2014. Baseline demographics for fetal presentation (cephalic/breech), birth presentation (vaginal/cesarean), birth weight, maternal age, maternal parity, gestational age, family history, and swaddling history of patients were compared among nine different sites for patients who were enrolled at age younger than 3 months and those enrolled between 3 and 18 months of age. A total of 392 patients were enrolled at baseline between 0 and 18 months of age with at least one dislocated hip. Of that group, 259 patients were younger than 3 months of age and 133 were 3 to 18 months of age. The proportion of patients with DDH who were enrolled and followed at the nine participating centers was 98%. RESULTS: A univariate/multivariate analysis was performed comparing key baseline demographics between early- and late-presenting patients. After controlling for relevant confounding variables, two variables were identified as risk factors for late-presenting DDH as compared with early-presenting: cephalic presentation at birth and swaddling history. Late-presenting patients were more likely to have had a cephalic presentation than early-presenting patients (88% [117 of 133] versus 65% [169 or 259]; odds ratio [OR], 5.366; 95% confidence interval [CI], 2.44-11.78; p < 0.001). Additionally, late-presenting patients were more likely to have had a history of swaddling (40% [53 of 133] versus 25% [64 of 259]; OR, 2.053; 95% CI, 1.22-3.45; p = 0.0016). No difference was seen for sex (p = 0.63), birth presentation (p = 0.088), birth weight (p = 0.90), maternal age (p = 0.39), maternal parity (p = 0.54), gestational age (p = 0.42), or family history (p = 0.11) between the two groups. Late presenters were more likely to present with an irreducible dislocation than early presenters (56% [82 of 147 hips] versus 19% [63 of 333 hips]; OR, 5.407; 95% CI, 3.532-8.275; p < 0.001) and were less likely to have a bilateral dislocation (11% [14 of 133] versus 28% [73 of 259]; OR, 0.300; 95% CI, 0.162-0.555; p = 0.002). CONCLUSIONS: Those presenting with DDH after 3 months of age have fewer of the traditional risk factors for DDH (such as breech birth), which may explain the reason for a missed diagnosis at a younger age. In addition, swaddling history was more common in late-presenting infants. A high index of suspicion for DDH should be maintained for all infants, not just those with traditional risk factors for DDH. Further investigation is required to determine if swaddling is a risk factor for the development of hip dislocations in older infants. More rigorous examination into traditional screening methods should also be performed to determine whether current screening is sufficient and whether late-presenting dislocations are present early and missed or whether they develop over time. LEVEL OF EVIDENCE: Level III, retrospective study.


Asunto(s)
Diagnóstico Tardío , Luxación Congénita de la Cadera/diagnóstico , Articulación de la Cadera/fisiopatología , Factores de Edad , Ropa de Cama y Ropa Blanca , Bases de Datos Factuales , Femenino , Luxación Congénita de la Cadera/fisiopatología , Luxación Congénita de la Cadera/terapia , Humanos , Lactante , Cuidado del Lactante/métodos , Presentación en Trabajo de Parto , Modelos Logísticos , Masculino , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Embarazo , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
15.
J Biomech ; 48(10): 2026-33, 2015 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-25957995

RESUMEN

A physics-based computational model of neonatal Developmental Dysplasia of the Hip (DDH) following treatment with the Pavlik Harness (PV) was developed to obtain muscle force contribution in order to elucidate biomechanical factors influencing the reduction of dislocated hips. Clinical observation suggests that reduction occurs in deep sleep involving passive muscle action. Consequently, a set of five (5) adductor muscles were identified as mediators of reduction using the PV. A Fung/Hill-type model was used to characterize muscle response. Four grades (1-4) of dislocation were considered, with one (1) being a low subluxation and four (4) a severe dislocation. A three-dimensional model of the pelvis-femur lower limb of a representative 10 week-old female was generated based on CT-scans with the aid of anthropomorphic scaling of anatomical landmarks. The model was calibrated to achieve equilibrium at 90° flexion and 80° abduction. The hip was computationally dislocated according to the grade under investigation, the femur was restrained to move in an envelope consistent with PV restraints, and the dynamic response under passive muscle action and the effect of gravity was resolved. Model results with an anteversion angle of 50° show successful reduction Grades 1-3, while Grade 4 failed to reduce with the PV. These results are consistent with a previous study based on a simplified anatomically-consistent synthetic model and clinical reports of very low success of the PV for Grade 4. However our model indicated that it is possible to achieve reduction of Grade 4 dislocation by hyperflexion and the resultant external rotation.


Asunto(s)
Luxación Congénita de la Cadera/patología , Cadera/patología , Fenómenos Mecánicos , Modelación Específica para el Paciente , Fenómenos Biomecánicos , Femenino , Fémur/diagnóstico por imagen , Cadera/diagnóstico por imagen , Cadera/fisiopatología , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/fisiopatología , Humanos , Lactante , Recién Nacido , Extremidad Inferior/diagnóstico por imagen , Músculo Esquelético/diagnóstico por imagen , Rango del Movimiento Articular , Tomografía Computarizada por Rayos X
16.
J Pediatr Orthop ; 35(5): 478-84, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25264556

RESUMEN

BACKGROUND: Existing radiographic classification schemes (eg, Tönnis criteria) for DDH quantify the severity of disease based on the position of the ossific nucleus relative to Hilgenreiner's and Perkin's lines. By definition, this method requires the presence of an ossification centre, which can be delayed in appearance and eccentric in location within the femoral head. A new radiographic classification system has been developed by the International Hip Dysplasia Institute (IHDI), which uses the mid-point of the proximal femoral metaphysis as a reference landmark, and can therefore be applied to children of all ages. The purpose of this study was to compare the reliability of this new method with that of Tönnis, as the first step in establishing its validity and clinical utility. METHODS: Twenty standardized anteroposterior pelvic radiographs of children with untreated DDH were selected purposefully to capture the spectrum of age (range, 3 to 32 mo) at presentation and disease severity. Each of the hips was classified separately by the IHDI and Tönnis methods by 6 experienced pediatric orthopaedists from the United States, Canada, Mexico, United Kingdom, and by 2 orthopaedic senior residents. The inter-rater reliability was tested using the Intra Class Correlation coefficient (ICC) to measure concordance between raters. RESULTS: All 40 hips were classifiable by the IHDI method by all raters. Ten of the 40 hips could not be classified by the Tönnis method because of the absence of the ossific nucleus on one or both sides. The ICC (95% confidence interval) for the IHDI method for all raters was 0.90 (0.83-0.95) and 0.95 (0.91-0.98) for the right and left hips, respectively. The corresponding ICCs for the Tönnis method were 0.63 (0.46-0.80) and 0.60 (0.43-0.78), respectively. There was no significant difference between the ICCs of the 6 experts and 2 trainees. CONCLUSIONS: The IHDI method of classification has excellent inter-rater reliability, both among experts and novices, and is more widely applicable than the Tönnis method as it can be applied even when the ossification centre is absent. LEVEL OF EVIDENCE: Level II (diagnostic).


Asunto(s)
Clasificación/métodos , Luxación Congénita de la Cadera , Cadera/diagnóstico por imagen , Femenino , Luxación Congénita de la Cadera/clasificación , Luxación Congénita de la Cadera/diagnóstico por imagen , Humanos , Lactante , Masculino , Radiografía , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
17.
J Child Orthop ; 8(6): 451-5, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25374058

RESUMEN

PURPOSE: One goal of neonatal screening for developmental dysplasia of the hip (DDH) is the prevention of late surgery. However, the majority of patients with acetabular dysplasia at skeletal maturity are not diagnosed with DDH during infancy. Selective ultrasound screening may identify patients with neonatal hip instability, but may be ineffective for the prevention of dysplasia presenting in adulthood. The purpose of this study is to identify the prevalence of risk factors for DDH that would have warranted selective ultrasound screening in patients with symptomatic acetabular dysplasia after skeletal maturity. METHODS: A prospective hip specialty center registry was used to identify 68 consecutive skeletally mature patients undergoing corrective osteotomy for symptomatic acetabular dysplasia. Risk factors for DDH evaluated in all patients included sex, family history of hip osteoarthritis or DDH, breech, method of delivery, previous hip treatments, and birth order. Radiographs [lateral center edge angle (CEA), anterior CEA, Tönnis grade, and Tönnis angle] were measured preoperatively. RESULTS: Sixty-seven females and one male were identified. No patients were previously diagnosed with DDH or received treatment for their hips. The majority of patients (85.3 %) did not meet selective ultrasound screening guidelines following a stable neonatal hip exam and, therefore, would not have been screened in a selective screening program. Of the findings outside of screening guidelines, 98.5 % were females, 52.9 % were first born, and 36.8 % had a family history of hip osteoarthritis. CONCLUSIONS: The majority (85.3 %) of patients with symptomatic acetabular dysplasia at skeletal maturity would not have met current recommendations for selective ultrasound screening in the USA had they been born today.

18.
J Pediatr Orthop ; 34(6): 603-6, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24840659

RESUMEN

BACKGROUND: Spinal bracing is widely utilized in patients with moderate severity adolescent idiopathic scoliosis with the goal of preventing curve progression and therefore preventing the need for surgical correction. Bracing is typically initiated in patients with a primary curve angle between 25 and 40 degrees, who are Risser sign 0 to 2 and <1-year postmenarchal. The purpose of this study is to determine whether nighttime bracing using a Charleston bending brace is effective in preventing progression of smaller curves (15 to 25 degrees) in skeletally immature, premenarchal female patients relative to current standard of care (observation for curves <25 degrees). METHODS: Premenarchal, Risser 0 female patients presenting to 2 pediatric orthopaedic specialty practices for evaluation of idiopathic scoliosis with Cobb angle measurements between 15 and 25 degrees were selected. They were randomized by location to receive nighttime bending brace treatment or observation. Patients in the observation group were converted to fulltime TLSO wear if they progressed to >25 degrees primary curve Cobb angle. Curve progression was monitored with minimum 2-year follow-up. RESULTS: Sixteen patients in the observation group and 21 patients in the bracing group completed 2-year follow-up. All patients in the observation group progressed to fulltime bracing threshold. In the nighttime bracing group, 29% of the patients did not progress to 25 degrees primary curve magnitude. Rate of progression to surgical magnitude was similar in the 2 groups. CONCLUSIONS: Risser 0 patients presenting with mild idiopathic scoliosis are at high risk for progression to >25 degrees primary curve magnitude. Treatment with the Charleston nighttime bending brace may reduce progression to full-time bracing threshold. No difference in progression to surgical intervention was shown between nighttime bracing and observation for small curves. LEVEL OF EVIDENCE: Level II--therapeutic study (prospective comparative study).


Asunto(s)
Tirantes , Escoliosis/terapia , Adolescente , Niño , Progresión de la Enfermedad , Diseño de Equipo , Femenino , Humanos , Estudios Prospectivos , Escoliosis/clasificación , Índice de Severidad de la Enfermedad
19.
Int J Endocrinol ; 2013: 316783, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23762049

RESUMEN

Physicians are aware of the benefits of calcium and vitamin D supplementation. However, additional nutritional components may also be important for bone health. There is a growing body of the scientific literature which recognizes that silicon plays an essential role in bone formation and maintenance. Silicon improves bone matrix quality and facilitates bone mineralization. Increased intake of bioavailable silicon has been associated with increased bone mineral density. Silicon supplementation in animals and humans has been shown to increase bone mineral density and improve bone strength. Dietary sources of bioavailable silicon include whole grains, cereals, beer, and some vegetables such as green beans. Silicon in the form of silica, or silicon dioxide (SiO2), is a common food additive but has limited intestinal absorption. More attention to this important mineral by the academic community may lead to improved nutrition, dietary supplements, and better understanding of the role of silicon in the management of postmenopausal osteoporosis.

20.
J Biomech ; 46(9): 1501-7, 2013 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-23631856

RESUMEN

Biomechanical factors influencing the reduction of dislocated hips with the Pavlik harness in patients of Developmental Dysplasia of the Hip (DDH) were studied using a three-dimensional computer model simulating hip reduction dynamics in (1) subluxated and (2) fully dislocated hip joints. Five hip adductor muscles were identified as key mediators of DDH prognosis, and the non-dimensional force contribution of each in the direction necessary to achieve concentric hip reductions was determined. Results point to the adductor muscles as mediators of subluxated hip reductions, as their mechanical action is a function of the degree of hip dislocation. For subluxated hips in abduction and flexion, the Pectineus, Adductor Brevis, Adductor Longus, and proximal Adductor Magnus contribute positively to reduction, while the rest of the Adductor Magnus contributes negatively. In full dislocations all muscles contribute detrimentally to reduction, elucidating the need for traction to reduce Graf IV type dislocations. Reduction of dysplastic hips was found to occur in two distinct phases: (a) release phase and (b) reduction phase.


Asunto(s)
Luxación Congénita de la Cadera/terapia , Modelos Teóricos , Restricción Física/instrumentación , Simulación por Computador , Femenino , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/fisiopatología , Humanos , Lactante , Extremidad Inferior/fisiopatología , Músculo Esquelético/fisiopatología , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA