Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JCO Precis Oncol ; 5: 953-973, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34136742

RESUMEN

Four programmed death ligand 1 (PD-L1) immunohistochemistry assays (28-8, 22C3, SP263, and SP142) have been approved for use by the US Food and Drug Administration (FDA). Analytical concordance between these assays has been evaluated in multiple studies. This systematic review included studies that investigated the analytical concordance of immunohistochemistry assays utilizing two or more PD-L1 antibodies from FDA-approved diagnostics for evaluation of PD-L1 expression on tumor or immune cells across a range of tumor types and algorithms. METHODS: Literature searches were conducted in MEDLINE (via PubMed) and EMBASE to identify studies published between January 1, 2010, and March 31, 2019, that evaluated analytical concordance between two or more assays based on antibodies from FDA-approved assays. Proceedings of key oncology and pathology congresses that took place between January 2016 and March 2019 were searched for abstracts of studies evaluating PD-L1 assay concordance. RESULTS: A total of 42 studies across a range of tumor types met the selection criteria. Concordance between 28-8-, 22C3-, and SP263-based assays in lung cancer, urothelial carcinoma, and squamous cell carcinoma of the head and neck was high when used to assess PD-L1 expression on tumor cells (TCs). SP142-based assays had overall low concordance with other approved assays when used to assess PD-L1 expression on TCs. Analytical concordance for assessment of PD-L1 expression on immune cells was variable and generally lower than for PD-L1 expression on TCs. CONCLUSION: A large body of evidence supports the potential interchangeability of 28-8-, 22C3-, and SP263-based assays for the assessment of PD-L1 expression on TCs in lung cancer. Further studies are required in tumor types for which less evidence is available.


Asunto(s)
Anticuerpos/análisis , Antígeno B7-H1/inmunología , Neoplasias/diagnóstico , Neoplasias/inmunología , Humanos , Inmunohistoquímica , Estadificación de Neoplasias , Estados Unidos , United States Food and Drug Administration
2.
J Clin Pathol ; 73(10): 656-664, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32591352

RESUMEN

AIMS: Programmed death-1/programmed death ligand 1 (PD-1/PD-L1) inhibitor therapy is accompanied by companion or complementary PD-L1 testing in some tumour types. We investigated utilisation of the Dako PD-L1 IHC 28-8 and 22C3 pharmDx assays and the Ventana PD-L1 (SP142) assay and evaluated concordance between the 28-8 and 22C3 assays in a real-world cohort of patients tested at a single US national reference laboratory. METHODS: NeoGenomics Laboratories performed PD-L1 testing on tumour samples between October 2015 and March 2018. PD-L1 test results were matched with patient characteristics using unique identifiers. Concordance between the 28-8 and 22C3 assays was evaluated in matched tumour samples. Data were evaluated across multiple tumour types and in subgroups of patients with lung cancer, melanoma, squamous cell carcinoma of the head and neck, and urothelial carcinoma. RESULTS: 62 180 individual PD-L1 tests were conducted on samples from 55 652 patients. PD-L1 test volume increased ~10-fold over the period evaluated. Test failure rates were typically low, and test turnaround time (TAT) ranged between 2 and 4 days. Concordance between the 28-8 and 22C3 assays was strong in the overall population and across tumour type subgroups (Kendall's tau correlations of 0.94 and 0.92-0.98, respectively). CONCLUSIONS: Test failure rates for PD-L1 tests were low and TAT remained reasonable despite marked increases in test volume. Concordance was high between the 28-8 and 22C3 assays across a range of tumour types and biopsy locations. These findings add to the literature showing high concordance between the 28-8 and 22C3 assays.


Asunto(s)
Antígeno B7-H1/análisis , Biomarcadores de Tumor/análisis , Inmunohistoquímica , Humanos , Inmunohistoquímica/métodos , Inmunohistoquímica/normas , Inmunohistoquímica/estadística & datos numéricos , Neoplasias/metabolismo , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...