OBJECTIVE: An increasing number of commercial deep learning computer-aided detection (DL-CAD) systems are available but their cost-saving potential is largely unknown. This study aimed to gain insight into appropriate pricing for DL-CAD in different reading modes to be cost-saving and to determine the potentially most cost-effective reading mode for lung cancer screening. METHODS: In three representative settings, DL-CAD was evaluated as a concurrent, pre-screening, and second reader. Scoping review was performed to estimate radiologist reading time with and without DL-CAD. Hourly cost of radiologist time was collected for the USA (€196), UK (€127), and Poland (€45), and monetary equivalence of saved time was calculated. The minimum number of screening CTs to reach break-even was calculated for one-time investment of €51,616 for DL-CAD. RESULTS: Mean reading time was 162 (95% CI: 111-212) seconds per case without DL-CAD, which decreased by 77 (95% CI: 47-107) and 104 (95% CI: 71-136) seconds for DL-CAD as concurrent and pre-screening reader, respectively, and increased by 33-41 s for DL-CAD as second reader. This translates into €1.0-4.3 per-case cost for concurrent reading and €0.8-5.7 for pre-screening reading in the USA, UK, and Poland. To achieve break-even with a one-time investment, the minimum number of CT scans was 12,300-53,600 for concurrent reader, and 9400-65,000 for pre-screening reader in the three countries. CONCLUSIONS: Given current pricing, DL-CAD must be priced substantially below €6 in a pay-per-case setting or used in a high-workload environment to reach break-even in lung cancer screening. DL-CAD as pre-screening reader shows the largest potential to be cost-saving. CRITICAL RELEVANCE STATEMENT: Deep-learning computer-aided lung nodule detection (DL-CAD) software must be priced substantially below 6 euro in a pay-per-case setting or must be used in high-workload environments with one-time investment in order to achieve break-even. DL-CAD as a pre-screening reader has the greatest cost savings potential. KEY POINTS: • DL-CAD must be substantially below €6 in a pay-per-case setting to reach break-even. • DL-CAD must be used in a high-workload screening environment to achieve break-even. • DL-CAD as a pre-screening reader shows the largest potential to be cost-saving.

2.
Ann Surg ; 272(6): 919-924, 2020 12.
Article En | MEDLINE | ID: mdl-33021367

OBJECTIVE: To determine the yield of preoperative screening for COVID-19 with chest CT and RT-PCR in patients without COVID-19 symptoms. SUMMARY OF BACKGROUND DATA: Many centers are currently screening surgical patients for COVID-19 using either chest CT, RT-PCR or both, due to the risk for worsened surgical outcomes and nosocomial spread. The optimal design and yield of such a strategy are currently unknown. METHODS: This multicenter study included consecutive adult patients without COVID-19 symptoms who underwent preoperative screening using chest CT and RT-PCR before elective or emergency surgery under general anesthesia. RESULTS: A total of 2093 patients without COVID-19 symptoms were included in 14 participating centers; 1224 were screened by CT and RT-PCR and 869 by chest CT only. The positive yield of screening using a combination of chest CT and RT-PCR was 1.5% [95% confidence interval (CI): 0.8-2.1]. Individual yields were 0.7% (95% CI: 0.2-1.1) for chest CT and 1.1% (95% CI: 0.6-1.7) for RT-PCR; the incremental yield of chest CT was 0.4%. In relation to COVID-19 community prevalence, up to ∼6% positive RT-PCR was found for a daily hospital admission rate >1.5 per 100,000 inhabitants, and around 1.0% for lower prevalence. CONCLUSIONS: One in every 100 patients without COVID-19 symptoms tested positive for SARS-CoV-2 with RT-PCR; this yield increased in conjunction with community prevalence. The added value of chest CT was limited. Preoperative screening allowed us to take adequate precautions for SARS-CoV-2 positive patients in a surgical population, whereas negative patients needed only routine procedures.


Asymptomatic Infections , COVID-19/diagnosis , Emergency Treatment , Mass Screening/statistics & numerical data , Preoperative Care/methods , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2 , Surgical Procedures, Operative , Thorax/diagnostic imaging , Tomography, X-Ray Computed , Elective Surgical Procedures , Humans , Retrospective Studies
3.
Forensic Sci Med Pathol ; 12(3): 248-56, 2016 Sep.
Article En | MEDLINE | ID: mdl-27117292

PURPOSE: After death, a series of changes occur naturally in the human body in a fairly regular pattern. These postmortem changes are detectable on postmortem CT scans (PMCT) and may be useful in estimating the postmortem interval (PMI). The purpose of our study is to correlate the PMCT radiodensities of the cerebrospinal fluid (CSF) and vitreous humor (VH) to the PMI. METHODS: Three patient groups were included: group A consisted of 5 donated cadavers, group B, 100 in-hospital deceased patients, and group C, 12 out-of-hospital forensic cadavers. Group A were scanned every hour for a maximum of 36 h postmortem, and the tympanic temperature was measured prior to each scan. Groups B and C were scanned once after death (PMI range 0.2-63.8 h). Radiodensities of the VH and CSF were measured in Hounsfield units. Correlation between density and PMI was determined using linear regression and the influence of temperature was assessed by a multivariate regression model. Results from group A were validated in groups B and C. RESULTS: Group A showed increasing radiodensity of the CSF and VH over time (r (2) CSF, 0.65). PMI overruled the influence of temperature (r = 0.99 and p = 0.000). Groups B and C showed more diversity, with CSF and VH radiodensities below the mean regression line of Group A. The formula of this upper limit indicated the maximum PMI and was correct for >95 % of the cadavers. CONCLUSION: The results of group A showed a significant correlation between CSF radiodensity and PMI. The radiodensities in groups B and C were higher than in group A, therefore the maximum PMI can be estimated with the upper 95 % confidence interval of the correlation line of group A.


Cerebrospinal Fluid/diagnostic imaging , Postmortem Changes , Vitreous Body/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Body Temperature , Child , Child, Preschool , Female , Humans , Infant , Linear Models , Male , Middle Aged , Tomography, X-Ray Computed , Young Adult
...