1.
Cureus ; 15(11): e48519, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38073942

RESUMEN

Infectious aortitis is a rare disease process that presents with mortality varying from 60% to 90%, even with aggressive treatment. This is a case involving a 69-year-old male who initially presented for acute encephalopathy. The patient's past medical history included coronary disease status post coronary bypass graft, abdominal aortic aneurysm status post endograft repair, prurigo nodularis, Tangier's disease, type 2 diabetes mellitus, and stage 3b chronic kidney disease. Initially, the work-up was unrevealing for a cause of the patient's acute encephalopathy. However, astute clinical evaluation led to the diagnosis of methicillin-sensitive Staphylococcus aureus (MSSA) bacteremia and abdominal infectious aortitis. Prurigo nodularis is a chronic dermatologic condition characterized by the development of intensely pruritic, firm nodules or bumps on the skin associated with itching and scratching. Prurigo nodularis itself does not directly result in bacteremia. However, in rare cases, severe and persistent scratching due to prurigo nodularis can lead to breaks in the skin, creating an entry point for bacteria to spread by the hematogenous route. Certainly, it is highly unusual to have a combination of prurigo nodularis, MSSA bacteremia, and abdominal aortic aneurysm endograft infection. Given the severity of these conditions individually, the combination presents a unique and challenging clinical scenario that requires prompt and coordinated management by a multidisciplinary team. This case report aims to provide new insights into the potential risk factors, clinical course, and management strategies for these combined conditions.

2.
PLoS One ; 17(2): e0262713, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35113908

RESUMEN

Cone beam computed tomography (CBCT) is now widely used in dentistry and growing areas of medical imaging. The presence of strong metal artifacts is however a major concern of using CBCT especially in dentistry due to the presence of highly attenuating dental restorations, fixed appliances, and implants. Virtual monoenergetic images (VMIs) synthesized from dual energy CT (DECT) datasets are known to reduce metal artifacts. Although several techniques exist for DECT imaging, they in general come with significantly increased equipment cost and not available in dental clinics. The objectives of this study were to investigate the feasibility of developing a low-cost dual energy CBCT (DE-CBCT) by retrofitting a regular CBCT scanner with a carbon nanotube (CNT) x-ray source with dual focal spots and corresponding low-energy (LE) and high-energy (HE) spectral filters. A testbed with a CNT field emission x-ray source (NuRay Technology, Chang Zhou, China), a flat panel detector (Teledyne, Waterloo, Canada), and a rotating object stage was used for this feasibility study. Two distinct polychromatic x-ray spectra with the mean photon energies of 66.7keV and 86.3keV were produced at a fixed 120kVp x-ray tube voltage by using Al+Au and Al+Sn foils as the respective LE and HE filters attached to the exist window of the x-ray source. The HE filter attenuated the x-ray photons more than the LE filter. The calculated post-object air kerma rate of the HE beam was 31.7% of the LE beam. An anthropomorphic head phantom (RANDO, Nuclear Associates, Hicksville, NY) with metal beads was imaged using the testbed and the images were reconstructed using an iterative volumetric CT reconstruction algorithm. The VMIs were synthesized using an image-domain basis materials decomposition method with energy ranging from 30 to 150keV. The results were compared to the reconstructed images from a single energy clinical dental CBCT scanner (CS9300, Carestream Dental, Atlanta, GA). A significant reduction of the metal artifacts was observed in the VMI images synthesized at high energies compared to those from the same object imaged by the clinical dental CBCT scanner. The ability of the CNT x-ray source to generate the output needed to compensate the reduction of photon flux due to attenuation from the spectral filters and to maintain the CT imaging time was evaluated. The results demonstrated the feasibility of DE-CBCT imaging using the proposed approach. Metal artifact reduction was achieved in VMIs synthesized. The x-ray output needed for the proposed DE-CBCT can be generated by a fixed-anode CNT x-ray source.


Asunto(s)
Nanotubos de Carbono
3.
Am J Vet Res ; 82(11): 872-879, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34669497

RESUMEN

OBJECTIVE: To describe the technique and assess the diagnostic potential and limitations of tomosynthesis for imaging of the metacarpophalangeal joint (MCPJ) of equine cadavers; compare the tomosynthesis appearance of pathological lesions with their conventional radiographic, CT, and MRI appearances; and evaluate all imaging findings with gross lesions of a given MCPJ. SAMPLE: Distal portions of 4 forelimbs from 4 equine cadavers. PROCEDURES: The MCPJs underwent radiography, tomosynthesis (with a purpose-built benchtop unit), CT, and MRI; thereafter, MCPJs were disarticulated and evaluated for the presence of gross lesions. The ability to identify pathological lesions on all images was assessed, followed by semiobjective scoring for quality of the overall image and appearance of the subchondral bone, articular cartilage, periarticular margins, and adjacent trabecular bone of the third metacarpal bone, proximal phalanx, and proximal sesamoid bones of each MCPJ. RESULTS: Some pathological lesions in the subchondral bone of the third metacarpal bone were detectable with tomosynthesis but not with radiography. Overall, tomosynthesis was comparable to radiography, but volumetric imaging modalities were superior to tomosynthesis and radiography for imaging of subchondral bone, articular cartilage, periarticular margins, and adjacent bone. CONCLUSIONS AND CLINICAL RELEVANCE: With regard to the diagnostic characterization of equine MCPJs, tomosynthesis may be more accurate than radiography for identification of lesions within subchondral bone because, in part, of its ability to reduce superimposition of regional anatomic features. Tomosynthesis may be useful as an adjunctive imaging technique, highlighting subtle lesions within bone, compared with standard radiographic findings.


Asunto(s)
Enfermedades de los Caballos , Huesos del Metacarpo , Animales , Cadáver , Enfermedades de los Caballos/diagnóstico por imagen , Caballos , Articulaciones/diagnóstico por imagen , Imagen por Resonancia Magnética/veterinaria , Huesos del Metacarpo/diagnóstico por imagen , Articulación Metacarpofalángica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/veterinaria
4.
Mil Med ; 186(Suppl 1): 745-750, 2021 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-33499472

RESUMEN

INTRODUCTION: Musculoskeletal injury to extremities is a common issue for both stateside and deployed military personnel, as well as the general public. Superposition of anatomy can make diagnosis difficult using standard clinical techniques. There is a need for increased diagnostic accuracy at the point-of-care for military personnel in both training and operational environments, as well as assessment during follow-up treatment to optimize care and expedite return to service. Orthopedic tomosynthesis is rapidly emerging as an alternative to digital radiography (DR), exhibiting an increase in sensitivity for some clinical tasks, including diagnosis and follow-up of fracture and arthritis. Commercially available digital tomosynthesis systems are large complex devices. A compact device for extremity tomosynthesis (TomoE) was previously demonstrated using carbon nanotube X-ray source array technology. The purpose of this study was to prepare and evaluate the prototype device for an Institutional Review Board-approved patient wrist imaging study and provide initial patient imaging results. MATERIALS AND METHODS: A benchtop device was constructed using a carbon nanotube X-ray source array and a flat panel digital detector. Twenty-one X-ray projection images of cadaveric specimens and human subjects were acquired at incident angles from -20 to +20 degrees in various clinical orientations, with entrance dose calibrated to commercial digital tomosynthesis wrist scans. The projection images were processed with an iterative reconstruction algorithm in 1 mm slices. Reconstruction slice images were evaluated by a radiologist for feature conspicuity and diagnostic accuracy. RESULTS: The TomoE image quality was found to provide more diagnostic information than DR, with reconstruction slices exhibiting delineation of joint space, visual conspicuity of trabecular bone, bone erosions, fractures, and clear depiction of normal anatomical features. The scan time was 15 seconds and the skin entrance dose was verified to be 0.2 mGy. CONCLUSIONS: The TomoE device image quality has been evaluated using cadaveric specimens. Dose was calibrated for a patient imaging study. Initial patient images depict a high level of anatomical detail and an increase in diagnostic value compared to DR.


Asunto(s)
Sistemas de Atención de Punto , Muñeca , Humanos , Imagenología Tridimensional , Intensificación de Imagen Radiográfica , Tomografía Computarizada por Rayos X
5.
Dentomaxillofac Radiol ; 50(2): 20200159, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32666823

RESUMEN

OBJECTIVES: A practical approach to three-dimensional (3D) intraoral imaging would have many potential applications in clinical dentistry. Stationary intraoral tomosynthesis (sIOT) is an experimental 3D imaging technology that holds promise. The purpose of this study was to explore synthetic radiography as a tool to improve the clinical utility of the images generated by an sIOT scan. METHODS: Extracted tooth specimens containing either caries adjacent to restorations (CAR) or vertical root fractures (VRF) were imaged by sIOT and standard dental radiography devices. Qualitative assessments were used to compare the conspicuity of these pathologies in the standard radiographs and in a set of multi-view synthetic radiographs generated from the information collected by sIOT. RESULTS: The sIOT-based synthetic 2D radiographs contained less artefact than the image slices in the reconstructed 3D stack, which is the conventional approach to displaying information from a tomosynthesis scan. As a single sIOT scan can be used to generate synthetic radiographs from multiple viewing angles, the interproximal space was less likely to be obscured in the synthetic images compared to the standard radiograph. Additionally, the multi-view synthetic radiographs can potentially improve the display of CAR and VRFs as compared to a single standard radiograph. CONCLUSIONS: This preliminary experience combining synthetic radiography and sIOT in extracted tooth models is encouraging and supports the ongoing study of this promising approach to 3D intraoral imaging with many potential applications.


Asunto(s)
Caries Dental , Imagenología Tridimensional , Caries Dental/diagnóstico por imagen , Clínicas Odontológicas , Humanos , Intensificación de Imagen Radiográfica , Radiografía , Radiografía Dental
6.
Acad Radiol ; 26(10): 1363-1372, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30660473

RESUMEN

RATIONALE AND OBJECTIVES: A linear array of carbon nanotube-enabled x-ray sources allows for stationary digital breast tomosynthesis (sDBT), during which projection views are collected without the need to move the x-ray tube. This work presents our initial clinical experience with a first-generation sDBT device. MATERIALS AND METHODS: Following informed consent, women with a "suspicious abnormality" (Breast Imaging Reporting and Data System 4), discovered by digital mammography and awaiting biopsy, were also imaged by the first generation sDBT. Four radiologists participated in this paired-image study, completing questionnaires while interpreting the mammograms and sDBT image stacks. Areas under the receiver operating characteristic curve were used to measure reader performance (likelihood of correctly identifying malignancy based on pathology as ground truth), while a multivariate analysis assessed preference, as readers compared one modality to the next when interpreting diagnostically important image features. RESULTS: Findings from 43 women were available for analysis, in whom 12 cases of malignancy were identified by pathology. The mean areas under the receiver operating characteristic curve was significantly higher (p < 0.05) for sDBT than mammography for all breast density categories and breast thicknesses. Additionally, readers preferred sDBT over mammography when evaluating mass margins and shape, architectural distortion, and asymmetry, but preferred mammography when characterizing microcalcifications. CONCLUSION: Readers preferred sDBT over mammography when interpreting soft-tissue breast features and were diagnostically more accurate using images generated by sDBT in a Breast Imaging Reporting and Data System 4 population. However, the findings also demonstrated the need to improve microcalcification conspicuity, which is guiding both technological and image-processing design changes in future sDBT devices.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Mama , Procesamiento de Imagen Asistido por Computador/métodos , Mamografía , Intensificación de Imagen Radiográfica/métodos , Adulto , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Femenino , Humanos , Mamografía/instrumentación , Mamografía/métodos , Persona de Mediana Edad , Imagen Multimodal , Nanotubos de Carbono
7.
Artículo en Inglés | MEDLINE | ID: mdl-33304617

RESUMEN

PURPOSE: To assess the visibility of microcalcifications in images generated by a first-generation carbon-nanotube (CNT)-enabled stationary digital breast tomosynthesis (sDBT) device, using magnified 2D mammography and conventional, moving-source DBT as references for comparison. METHODS: Lumpectomy specimens were imaged by magnified mammography and two 3D mammography approaches, including sDBT and moving-source DBT. The planar size of individual microcalcifications was measured in the reconstructed image stacks of sDBT and moving-source DBT and compared to the magnified mammography image. An artifact spread function (ASF) was used to assess the depth dimensions of the microcalcifications displayed through the reconstructed image stacks. Breast-imaging specialists rated their preference for one imaging modality over another when interpreting microcalcifications in the magnified mammography image and synthetic slab images from sDBT and moving-source DBT. RESULTS: The planar size of individual microcalcifications was similar in images generated by sDBT and moving-source DBT when the sDBT projections were binned to match the pixel size used by the moving-source DBT system. However, the unique structure of sDBT allowed for a wider-angle span of projection views and operation of the detector in full-resolution mode without significantly compromising the scan time. In this configuration, the planar sizes of individual microcalcifications displayed by sDBT was more similar to magnified mammography than moving-source DBT, and the microcalcifications had a narrower ASF through depth. Readers preferred sDBT over moving-source DBT when assessing microcalcifications in synthetic slab images, although magnified mammography was rated highest overall. CONCLUSIONS: The sDBT system displayed microcalcifications as well as conventional, moving-source DBT when the effective pixel size of the detector was matched. However, with the detector in its full-resolution mode, sDBT displayed microcalcifications with greater clarity. Readers still preferred images generated by magnified mammography over both 3D mammography approaches. This finding is guiding continued hardware and software development to optimize the sDBT technology.

8.
Med Phys ; 45(11): 5172-5185, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30259988

RESUMEN

PURPOSE: Technological advancements in dental radiography have improved oral care on many fronts, yet diagnostic efficacy for some of the most common oral conditions, such as caries, dental cracks and fractures, and periodontal disease, remains relatively low. Driven by the clinical need for a better diagnostic yield for these and other dental conditions, we initiated the development of a stationary intraoral tomosynthesis (s-IOT) imaging system using carbon nanotube (CNT) x-ray source array technology. Here, we report the system characterization and preliminary imaging evaluation of a clinical prototype s-IOT system approved for human use. METHODS: The clinical prototype s-IOT system is comprised of a multibeam CNT x-ray source array, high voltage generator, control electronics, collimator cone, and dynamic digital intraoral detector. During a tomosynthesis scan, each x-ray source is operated sequentially at fixed, nominal tube current of 7 mA and user-specified pulse width. Images are acquired by a digital intraoral detector and the reconstruction algorithm generates slice information in real time for operator review. In this study, the s-IOT system was characterized for tube output, dosimetry, and spatial resolution. Manufacturer specifications were validated, such as tube current, kVp, and pulse width. Tube current was measured with an oscilloscope on the analog output of the anode power supply. Pulse width, kVp, and peak skin dose were measured with a dosimeter with ion chamber and high voltage accessory. In-plane spatial resolution was evaluated via measurement of MTF and imaging of a line pair phantom. Spatial resolution in the depth direction was evaluated via artifact spread measurement. The size of the collimated radiation field was evaluated for compliance with FDA regulations. A dental phantom and human specimens of varying pathologies were imaged on a clinical 2D intraoral imaging system as well as s-IOT for comparison and to explore potential clinical applications. RESULTS: The measured tube current, kVp, and pulse width values were within 3% of the set values. A cumulative peak skin dose of 1.12 mGy was measured for one complete tomosynthesis scan using a 50-ms pulse per projection view. Projection images and reconstruction slices revealed MTF values ranging from 8.1 to 9.3 cycles/mm. Line pair imaging verified this result. The radiation field was found to meet the FDA requirements for intraoral imaging devices. Tomosynthesis reconstruction slice images of the dental phantom and human specimens provided depth resolution, allowing visibility of anatomical features that cannot be seen in the 2D intraoral images. CONCLUSIONS: The clinical prototype s-IOT device was evaluated and found to meet all manufacturer specifications. Though the system capability is higher, initial investigations are targeting a low-dose range comparable to a single 2D radiograph. Preliminary studies indicated that s-IOT provides increased image quality and feature conspicuity at a dose comparable to a single 2D intraoral radiograph.


Asunto(s)
Boca/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Artefactos , Calibración , Diseño de Equipo , Humanos , Procesamiento de Imagen Asistido por Computador , Nanotubos de Carbono , Fantasmas de Imagen , Diente/diagnóstico por imagen
9.
J Med Imaging (Bellingham) ; 5(1): 013502, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29430472

RESUMEN

Stationary digital breast tomosynthesis (sDBT) is an emerging technology in which the single rotating x-ray tube is replaced by a fixed array of multiple carbon nanotube-enabled sources, providing a higher spatial and temporal resolution. As such, sDBT offers a promising platform for contrast-enhanced (CE) imaging. However, given the minimal enhancement above background with standard operational tube settings and iodine dosing, CE breast imaging requires additional acquisition steps to isolate the iodine signal, using either temporal or dual energy subtraction (TS or DES) protocols. Also, correcting for factors that limit contrast is critical, and scatter and noise pose unique challenges during tomosynthesis. This phantom-based study of CE sDBT compared different postacquisition scatter correction approaches on the quality of the reconstructed image slices. Beam-pass collimation was used to sample scatter indirectly, from which an interpolated scatter map was obtained for each projection image. Scatter-corrected projections provided the information for reconstruction. Comparison between the application of different scatter maps demonstrated the significant effect that processing has on the contrast-to-noise ratio and feature detectability ([Formula: see text]) in the final displayed images and emphasized the critical importance of scatter correction during DES.

10.
Artículo en Inglés | MEDLINE | ID: mdl-28398001

RESUMEN

A new imaging technology has emerged that uses carbon nanotubes (CNT) as the electron emitter (cathode) for the X-ray tube. Since the performance of the CNT cathode is controlled by simple voltage manipulation, CNT-enabled X-ray sources are ideal for the repetitive imaging steps needed to capture three-dimensional information. As such, they have allowed the development of a gated micro-computed tomography (CT) scanner for small animal research as well as stationary tomosynthesis, an experimental technology for large field-of-view human imaging. The small animal CT can acquire images at specific points in the respiratory and cardiac cycles. Longitudinal imaging therefore becomes possible and has been applied to many research questions, ranging from tumor response to the noninvasive assessment of cardiac output. Digital tomosynthesis (DT) is a low-dose and low-cost human imaging tool that captures some depth information. Known as three-dimensional mammography, DT is now used clinically for breast imaging. However, the resolution of currently-approved DT is limited by the need to swing the X-ray source through space to collect a series of projection views. An array of fixed and distributed CNT-enabled sources provides the solution and has been used to construct stationary DT devices for breast, lung, and dental imaging. To date, over 100 patients have been imaged on Institutional Review Board-approved study protocols. Early experience is promising, showing an excellent conspicuity of soft-tissue features, while also highlighting technical and post-acquisition processing limitations that are guiding continued research and development. Additionally, CNT-enabled sources are being tested in miniature X-ray tubes that are capable of generating adequate photon energies and tube currents for clinical imaging. Although there are many potential applications for these small field-of-view devices, initial experience has been with an X-ray source that can be inserted into the mouth for dental imaging. Conceived less than 20 years ago, CNT-enabled X-ray sources are now being manufactured on a commercial scale and are powering both research tools and experimental human imaging devices. WIREs Nanomed Nanobiotechnol 2018, 10:e1475. doi: 10.1002/wnan.1475 This article is categorized under: Diagnostic Tools > Diagnostic Nanodevices Diagnostic Tools > In Vivo Nanodiagnostics and Imaging.


Asunto(s)
Diagnóstico por Imagen , Nanotubos de Carbono/química , Animales , Humanos , Rayos X
11.
Artículo en Inglés | MEDLINE | ID: mdl-26415125

RESUMEN

Liquid-filled perfluorocarbon droplets emit a unique acoustic signature when vaporized into gas-filled microbubbles using ultrasound. Here, we conducted a pilot study in a tissue-mimicking flow phantom to explore the spatial aspects of droplet vaporization and investigate the effects of applied pressure and droplet concentration on image contrast and axial and lateral resolution. Control microbubble contrast agents were used for comparison. A confocal dual-frequency transducer was used to transmit at 8 MHz and passively receive at 1 MHz. Droplet signals were of significantly higher energy than microbubble signals. This resulted in improved signal separation and high contrast-to-tissue ratios (CTR). Specifically, with a peak negative pressure (PNP) of 450 kPa applied at the focus, the CTR of B-mode images was 18.3 dB for droplets and -0.4 for microbubbles. The lateral resolution was dictated by the size of the droplet activation area, with lower pressures resulting in smaller activation areas and improved lateral resolution (0.67 mm at 450 kPa). The axial resolution in droplet images was dictated by the size of the initial droplet and was independent of the properties of the transmit pulse (3.86 mm at 450 kPa). In post-processing, time-domain averaging (TDA) improved droplet and microbubble signal separation at high pressures (640 kPa and 700 kPa). Taken together, these results indicate that it is possible to generate high-sensitivity, high-contrast images of vaporization events. In the future, this has the potential to be applied in combination with droplet-mediated therapy to track treatment outcomes or as a standalone diagnostic system to monitor the physical properties of the surrounding environment.


Asunto(s)
Fluorocarburos/química , Microscopía Acústica/métodos , Ultrasonografía/métodos , Microburbujas , Fantasmas de Imagen , Transductores
12.
Ultrasound Med Biol ; 41(3): 814-31, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25619781

RESUMEN

Many studies have explored phase-change contrast agents (PCCAs) that can be vaporized by an ultrasonic pulse to form microbubbles for ultrasound imaging and therapy. However, few investigations have been published on the utility and characteristics of PCCAs as contrast agents in vivo. In this study, we examine the properties of low-boiling-point nanoscale PCCAs evaluated in vivo and compare data with those for conventional microbubbles with respect to contrast generation and circulation properties. To do this, we develop a custom pulse sequence to vaporize and image PCCAs using the Verasonics research platform and a clinical array transducer. Results indicate that droplets can produce contrast enhancement similar to that of microbubbles (7.29 to 18.24 dB over baseline, depending on formulation) and can be designed to circulate for as much as 3.3 times longer than microbubbles. This study also reports for the first time the ability to capture contrast washout kinetics of the target organ as a measure of vascular perfusion.


Asunto(s)
Medios de Contraste/química , Medios de Contraste/farmacocinética , Fluorocarburos/química , Fluorocarburos/farmacocinética , Riñón/irrigación sanguínea , Riñón/diagnóstico por imagen , Ultrasonografía/métodos , Animales , Cinética , Microburbujas , Transición de Fase , Ratas , Ratas Endogámicas F344 , Transductores
13.
J Acoust Soc Am ; 134(2): 1473-82, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23927187

RESUMEN

Ultrasound contrast agents are known to enhance high intensity focused ultrasound (HIFU) ablation, but these perfluorocarbon microbubbles are limited to the vasculature, have a short half-life in vivo, and may result in unintended heating away from the target site. Herein, a nano-sized (100-300 nm), dual perfluorocarbon (decafluorobutane/dodecafluoropentane) droplet that is stable, is sufficiently small to extravasate, and is convertible to micron-sized bubbles upon acoustic activation was investigated. Microbubbles and nanodroplets were incorporated into tissue-mimicking acrylamide-albumin phantoms. Microbubbles or nanodroplets at 0.1 × 10(6) per cm(3) resulted in mean lesion volumes of 80.4 ± 33.1 mm(3) and 52.8 ± 14.2 mm(3) (mean ± s.e.), respectively, after 20 s of continuous 1 MHz HIFU at a peak negative pressure of 4 MPa, compared to a lesion volume of 1.0 ± 0.8 mm(3) in agent-free control phantoms. Magnetic resonance thermometry mapping during HIFU confirmed undesired surface heating in phantoms containing microbubbles, whereas heating occurred at the acoustic focus of phantoms containing the nanodroplets. Maximal change in temperature at the target site was enhanced by 16.9% and 37.0% by microbubbles and nanodroplets, respectively. This perfluorocarbon nanodroplet has the potential to reduce the time to ablate tumors by one-third during focused ultrasound surgery while also safely enhancing thermal deposition at the target site.


Asunto(s)
Medios de Contraste/química , Fluorocarburos/química , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Calor , Acrilamidas/química , Albúminas/química , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Imagen por Resonancia Magnética , Microburbujas , Nanopartículas , Fantasmas de Imagen , Presión , Sonicación , Sonido , Termografía , Factores de Tiempo , Transductores , Volatilización
14.
J Ther Ultrasound ; 1: 16, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-25512861

RESUMEN

BACKGROUND: Phase-shift nanoemulsions (PSNEs) provide cavitation sites when the perfluorocarbon (PFC) nanodroplets (ND) are vaporized to microbubbles by acoustic energy. Their presence lowers the power required to ablate tissue by high-intensity focused ultrasound (HIFU), potentially making it a safer option for a broader range of treatment sites. However, spatial control over the ablation region can be problematic when cavitation is used to enhance heating. This study explored relationships between vaporization, ablation, and the PSNE concentration in vitro to optimize the acoustic intensity and insonation time required for spatially controlled ablation enhancement using a PSNE that included a volatile PFC component. METHODS: HIFU (continuous wave at 1 MHz; insonation times of 5, 10, 15, and 20 s; cool-down times of 2, 4, and 6 s; peak negative pressures of 2, 3, and 4 MPa) was applied to albumin-acrylamide gels containing PFC agents (1:1 mix of volatile decafluorobutane and more stable dodecafluoropentane at 10(5) to 10(8) PFC ND per milliliter) or agent-free controls. Vaporization fields (microbubble clouds) were imaged by conventional ultrasound, and ablation lesions were measured directly by calipers. Controlled ablation was defined as the production of 'cigar'-shaped lesions corresponding with the acoustic focal zone. This control was considered to be lost when ablation occurred in prefocal vaporization fields having a predominantly 'tadpole' or oblong shape. RESULTS: Changes in the vaporization field shape and location occurred on a continuum with increasing PSNE concentration and acoustic intensity. Working with the maximum concentration-intensity combinations resulting in controlled ablation demonstrated a dose-responsive relationship between insonation time and volumes of both the vaporization fields (approximately 20 to 240 mm(3)) and the ablation lesions (1 to 135 mm(3)) within them. CONCLUSIONS: HIFU ablation was enhanced by this PSNE and could be achieved using intensities ≤650 W/cm(2). Although the ablation lesions were located within much larger microbubble clouds, optimum insonation times and intensities could be selected to achieve an ablation lesion of desired size and location for a given PSNE concentration. This demonstration of controllable enhancement using a PSNE that contained a volatile PFC component is another step toward developing phase-shift nanotechnology as a potential clinical tool to improve HIFU.