Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 412
1.
Open Heart ; 11(1)2024 May 20.
Article En | MEDLINE | ID: mdl-38769066

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis Implantation , Ventricular Function, Left , Humans , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/diagnosis , Female , Male , Retrospective Studies , Aged , Heart Valve Prosthesis Implantation/methods , Ventricular Function, Left/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Treatment Outcome , Time Factors , Severity of Illness Index , Follow-Up Studies , Risk Factors , Echocardiography/methods , Aged, 80 and over , Survival Rate/trends , Risk Assessment/methods , Stroke Volume/physiology
3.
Res Sq ; 2024 May 02.
Article En | MEDLINE | ID: mdl-38746473

Oral tumors are relatively common in dogs, and canine oral squamous cell carcinoma (COSCC) is the most prevalent oral malignancy of epithelial origin. COSCC is locally aggressive with up to 20% of patients showing regional or distant metastasis at the time of diagnosis. The treatment of choice most typically involves wide surgical excision. Although long-term remission is possible, treatments are associated with significant morbidity and can negatively impact functionality and quality of life. OSCCs have significant upregulation of the RAS-RAF-MEK-MAPK signaling axis, and we had previously hypothesized that small-molecule inhibitors that target RAS signaling might effectively inhibit tumor growth and progression. Here, we demonstrate that the MEK inhibitor trametinib, an FDA-approved drug for human cancers, significantly blocks the growth of several COSCC cell lines established from current patient tumor samples. We further show clinical evidence that the drug is able to cause significant tumor regression in some patients with spontaneously occurring COSCC. Given the limited treatment options available and the high rate of owner rejection of these offered options, these findings provide new hope that more acceptable treatment options may soon enter the veterinary clinic.

5.
J Am Heart Assoc ; 13(10): e033601, 2024 May 21.
Article En | MEDLINE | ID: mdl-38761069

BACKGROUND: The aims of this study were to understand the incidence and outcomes of patients with cardiogenic shock (CS) due to severe aortic stenosis (AS), and the impact of conventional treatment strategies in this population. METHODS AND RESULTS: All patients admitted to the Cleveland Clinic cardiac intensive care unit between January 1, 2010 and December 31, 2021 with CS were retrospectively identified and categorized into those with CS in the setting of severe AS versus CS without AS. The impact of various treatment strategies on mortality was further assessed. We identified 2754 patients with CS during the study period, of whom 216 patients (8%) had CS in the setting of severe AS. Medical management was associated with the highest 30-day mortality when compared with either balloon aortic valve replacement or aortic valve replacement (surgical or transcatheter aortic valve replacement) (hazard ratio, 3.69 [95% CI, 2.04-6.66]; P<0.0001). Among patients who received transcatheter therapy, 30-day mortality was significantly higher in patients who received balloon aortic valvuloplasty versus transcatheter aortic valve replacement (26% versus 4%, P=0.02). Both surgical and transcatheter aortic valve replacement had considerably lower mortality than medical management and balloon aortic valvuloplasty at 30 days and 1 year (P<0.05 for both comparisons). CONCLUSIONS: CS due to severe AS is associated with high in-hospital and 30-day mortality, worse compared with those with CS without AS. In suitable patients, urgent surgical aortic valvuloplasty or transcatheter aortic valve replacement is associated with favorable short- and long-term outcomes. Although balloon aortic valvuloplasty may be used to temporize patients with CS in the setting of severe AS, mortality is ≈50% if not followed by definitive aortic valve replacement within 90 days.


Aortic Valve Stenosis , Severity of Illness Index , Shock, Cardiogenic , Transcatheter Aortic Valve Replacement , Humans , Shock, Cardiogenic/therapy , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Male , Female , Retrospective Studies , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Aged, 80 and over , Balloon Valvuloplasty/mortality , Balloon Valvuloplasty/adverse effects , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Risk Factors , Time Factors , Incidence
6.
Article En | MEDLINE | ID: mdl-38641438

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.

7.
Am J Cardiol ; 217: 86-93, 2024 Apr 15.
Article En | MEDLINE | ID: mdl-38432333

Low muscle mass (LMM) is associated with worse outcomes in various clinical situations. Traditional frailty markers have been used for preoperative risk stratification in patients who underwent transcatheter aortic valve replacement (TAVR). However, preoperative imaging provides an opportunity to directly quantify skeletal muscle mass to identify patients at higher risk of procedural complications. We reviewed all TAVR recipients from January to December 2018 and included subjects with preprocedural chest computed tomography. Multi-slice automated measurements of skeletal muscle mass were made from the ninth to twelfth thoracic vertebrae and normalized by height squared to obtain skeletal muscle index (cm2/m2). LMM was defined as the lowest gender-stratified skeletal muscle index tertile. Strength testing was collected during pre-TAVR evaluation. Primary outcome was a composite of perioperative complications, 1-year rehospitalization, or 1-year mortality. In our cohort, 238 patients met inclusion criteria, and 80 (33.6%) were identified to have LMM. Patients with LMM were older with lower body mass index, decreased grip strength, lower hemoglobin A1c, and higher N-terminal pro-brain natriuretic peptide. They had greater rates of the composite outcome and 2-year all-cause mortality, which remained significant on multivariable adjustment (hazard ratio 1.71, 95% confidence interval 1.05 to 2.78, p = 0.030 and hazard ratio 2.31, 95% confidence interval 1.02 to 5.24, p = 0.045, respectively) compared with patients without LMM; there was no significant difference in 5-year all-cause mortality. In conclusion, LMM was associated with an increase in the primary composite outcome and 2-year all-cause mortality in TAVR recipients. Using automatic muscle processing software on pre-TAVR computed tomography scans may serve as an additional preoperative risk stratification tool.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Aortic Valve Stenosis/complications , Tomography, X-Ray Computed/methods , Muscle, Skeletal/diagnostic imaging , Aortic Valve/surgery , Risk Factors
9.
JACC Case Rep ; 29(4): 102199, 2024 Feb 21.
Article En | MEDLINE | ID: mdl-38379657

Transcatheter aortic valve replacement is not widely used in patients with congenital heart disease. We describe our single-center experience of transcatheter aortic valve replacement in congenital heart disease, demonstrating short-term feasibility and safety, role in lifetime management of congenital aortic valve disease, and use as a bridge to recovery, future surgery, or transplantation.

10.
Eur Heart J ; 45(21): 1890-1900, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38270189

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.


Aortic Valve Stenosis , Coronary Artery Disease , Postoperative Complications , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Aged, 80 and over , Coronary Artery Disease/surgery , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Aged , Percutaneous Coronary Intervention , Treatment Outcome , Risk Factors
11.
Struct Heart ; 8(1): 100227, 2024 Jan.
Article En | MEDLINE | ID: mdl-38283572

Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve replacement being increasingly considered in younger patients with symptomatic BAV, with good clinical results, yet without randomized trial evidence. Procedural technique, along with clinical outcomes, have considerably improved in BAV patients compared with tricuspid aortic stenosis patients undergoing transcatheter aortic valve replacement. The present review summarizes the novel BAV classification systems and examines contemporary surgical and transcatheter approaches.

12.
Open Heart ; 11(1)2024 Jan 30.
Article En | MEDLINE | ID: mdl-38290731

BACKGROUND: Patients who experience in-hospital ST-segment elevation myocardial infarction (iSTEMI) represent a uniquely high-risk cohort owing to delays in diagnosis, prolonged time to reperfusion and increased mortality. Quality initiatives aimed at improving the care of this vulnerable, yet understudied population are needed. METHODS: This study included consecutive patients with iSTEMI treated with percutaneous coronary intervention (PCI) between 1 January 2011 and 15 July 2019 at a single, tertiary referral centre. A comprehensive iSTEMI protocol (CSP) was implemented on 15 July 2014, incorporating: (1) cardiology fellow activation of the catheterisation lab using standardised criteria, (2) nursing chest pain protocol, (3) improved electronic access to electrocardiographic studies, (4) checklist for initial triage and management, (5) 24/7/365 catheterisation lab readiness and (6) radial-first PCI approach. Key metrics and clinical outcomes were compared before and after CSP implementation. RESULTS: Among 125 total subjects, the post-CSP cohort (n=81) was younger, had more males and were more likely to be hospitalised for cardiac-related reasons relative to the pre-CSP cohort (n=44) who were more likely hospitalised for operative-related aetiologies. After CSP adoption, median ECG-to-first-device-activation time decreased from 113 min to 64 min (p<0.001), goal ECG-to-first-device-activation time increased from 36% to 76% of patients (p<0.001), administration of guideline-directed medical therapy prior to PCI increased from 27.3% to 65.4% (p<0.001), trans-radial access increased from 16% to 70% (p<0.001) and rates of discharge home increased from 56.8% to 76.5% (p=0.04). Statistically insignificant numerical reductions were observed post-CSP in in-hospital mortality (18.2% vs 9.9%, p=0.30), 30-day mortality (15.9% vs 12.3%, p=0.78) and 1-year mortality (27.3% vs 21.0%, p=0.57). CONCLUSIONS: The implementation of a CSP was associated with marked enhancements in key care metrics among patients with iSTEMI. Among a larger cohort, the use of a CSP yielded a significant reduction in ECG-to-first-device-activation time in a particularly vulnerable population at high risk of death.


Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Male , Cohort Studies , Hospitals , Observational Studies as Topic , Percutaneous Coronary Intervention/adverse effects , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/therapy , Triage , Female
13.
JACC Cardiovasc Interv ; 17(1): 60-72, 2024 Jan 08.
Article En | MEDLINE | ID: mdl-38069986

BACKGROUND: Several orthotopic transcatheter strategies have been developed to treat severe tricuspid regurgitation (TR); however, many patients are deemed unsuitable. Caval valve implantation with the TricValve system addresses this unmet need. OBJECTIVES: This study sought to determine the impact of TricValve on systemic congestion and quality of life (QOL) at 1 year. METHODS: The TRICUS (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) and TRICUS EURO studies were prospective, nonblinded, nonrandomized, single-arm trials representing the early-in-man experience of the TricValve system in NYHA functional class III or IV severe TR patients, optimally medicated and ineligible for open heart surgery, with significant caval backflow. The primary endpoint was QOL metrics and functional status. The 1-year results of the combined cohort are described here. RESULTS: Forty-four patients were included. Mean age was 76.2 ± 7.5 years, 81.0% were women, and the TRISCORE (risk score model for isolated tricuspid valve surgery) was 5.3 ± 1.3. Clinical improvement at 1 year was achieved in 42 (95.5%) patients, measured by (at least 1 of) an increase in ≥15 points from baseline in 12-item Kansas City Cardiomyopathy Questionnaire score, improvement to NYHA functional class to I or II, or an increase ≥40 m in the 6-minute walk test. There were 3 (6.8%) deaths at 1-year follow-up (1 cardiovascular), and the heart failure rehospitalization rate was 29.5%. Stent fracture, conduction system disturbances, or clinically significant leaflet thrombosis were not detected. Abolished hepatic vein backflow was achieved and persisted in 63.8% of the patients, contributing towards a reduction in congestive symptoms, N-terminal pro-B-type natriuretic peptide levels (P = 0.032), and diuretic treatment. CONCLUSIONS: Caval valve implantation with the TricValve system associated with meaningful 1-year clinical improvements in terms of QOL along with relatively low mortality rates. (TRICUS Study - Safety and Efficacy of the TricValve® Device; NCT03723239).


Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Aged , Aged, 80 and over , Female , Humans , Male , Cardiac Catheterization , Follow-Up Studies , Prospective Studies , Quality of Life , Severity of Illness Index , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery
14.
Curr Opin Cardiol ; 39(2): 110-118, 2024 03 01.
Article En | MEDLINE | ID: mdl-38116802

PURPOSE OF REVIEW: The unique pathophysiologic considerations of severe tricuspid regurgitation (TR) have led to advancements in surgical and transcatheter treatments. The purpose of this review is to highlight the current surgical and transcatheter tricuspid valve interventions (TTVI) to functional TR. RECENT FINDINGS: Surgical repair with ring annuloplasty consistently demonstrates better outcomes than surgical replacement or other repair approaches. However, surgical uptake of TR correction remains relatively low, and operative mortality rates are still high owing to multiple comorbidities and advanced tricuspid valve disease/right ventricular dysfunction at time of referral. Pivotal trials for tricuspid transcatheter edge-to-edge repair (T-TEER) and transcatheter TV replacement (TTVR) indicate improved quality of life compared to medical therapy alone for high-surgical-risk patients with severe symptomatic TR. Trials are underway to assess caval valve implantation (CAVI), which holds hope for many severe TR patients who are not ideal candidates for T-TEER or orthotopic TTVR. Peri-procedural optimization of right ventricular function remains critical to promote both device success and patient outcomes. SUMMARY: Clinical outcomes after surgical TV intervention are poor, often due to intervening late in the disease course of TR. TTVI covers a treatment gap for patients deemed inoperable or high-surgical-risk, but earlier referral for TV interventions is still important prior to patients developing multiorgan dysfunction from chronic untreated TR.


Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/adverse effects , Quality of Life , Treatment Outcome , Time Factors , Cardiac Catheterization , Heart Failure/surgery
16.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 24.
Article En | MEDLINE | ID: mdl-38132642

BACKGROUND: Regional functional left ventricular (LV) assessment using current imaging techniques remains limited. Inward displacement (InD) has been developed as a novel technique to assess regional LV function via measurement of the regional displacement of the LV endocardial border across each of the 17 LV segments. Currently, normal ranges for InD are not available for clinical use. The aim of this study was to validate the normal reference limits of InD in healthy adults across all LV segments. METHODS: InD was analyzed in 120 healthy subjects with a normal LV ejection fraction, using the three standard long-axis views obtained during cardiac MRI that quantified the degree of inward endocardial wall motion towards the true LV center of contraction. For all LV segments, InD was measured in mm and expressed as a percentage of the theoretical degree of maximal segment contraction towards the true LV centerline. The arithmetic average InD was obtained for each of the 17 segments. The LV was divided into three regions, obtaining average InD at the LV base (segments 1-6), mid-cavity (segments 7-12) and apex (segments 13-17). RESULTS: Average InD was 33.4 ± 4.3%. InD was higher in basal and mid-cavity LV segments (32.8 ± 4.1% and 38.1 ± 5.8%) compared to apical LV segments (28.6 ± 7.7%). Interobserver variability correlations for InD were strong (R = 0.80, p < 0.0001). CONCLUSIONS: We provide clinically meaningful reference ranges for InD in subjects with normal LV function, which will emerge as an important screening and assessment imaging tool for a range of HFrEF therapies.

17.
Eur Heart J Open ; 3(6): oead127, 2023 Nov.
Article En | MEDLINE | ID: mdl-38105920

Aims: Conduction abnormalities necessitating permanent pacemaker (PPM) implantation remain the most frequent complication post-transcatheter aortic valve implantation (TAVI), yet reliance on PPM function varies. We evaluated the association of right-ventricular (RV)-stimulation rate post-TAVI with 1-year major adverse cardiovascular events (MACE) (all-cause mortality and heart failure hospitalization). Methods and results: This retrospective cohort study of patients undergoing TAVI in two high-volume centers included patients with existing PPM pre-TAVI or new PPM post-TAVI. There was a bimodal distribution of RV-stimulation rates stratifying patients into two groups of either low [≤10%: 1.0 (0.0, 3.6)] or high [>10%: 96.0 (54.0, 99.9)] RV-stimulation rate post-TAVI. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated comparing MACE in patients with high vs. low RV-stimulation rates post-TAVI. Of 4659 patients, 408 patients (8.6%) had an existing PPM pre-TAVI and 361 patients (7.7%) underwent PPM implantation post-TAVI. Mean age was 82.3 ± 8.1 years, 39% were women. A high RV-stimulation rate (>10%) development post-TAVI is associated with a two-fold increased risk for MACE [1.97 (1.20, 3.25), P = 0.008]. Valve implantation depth was an independent predictor of high RV-stimulation rate [odds ratio (95% CI): 1.58 (1.21, 2.06), P=<0.001] and itself associated with MACE [1.27 (1.00, 1.59), P = 0.047]. Conclusion: Greater RV-stimulation rates post-TAVI correlate with increased 1-year MACE in patients with new PPM post-TAVI or in those with existing PPM but low RV-stimulation rates pre-TAVI. A shallower valve implantation depth reduces the risk of greater RV-stimulation rates post-TAVI, correlating with improved patient outcomes. These data highlight the importance of a meticulous implant technique even in TAVI recipients with pre-existing PPMs.

18.
JACC Case Rep ; 23: 102007, 2023 Oct 04.
Article En | MEDLINE | ID: mdl-37954951

Patients with severe tricuspid regurgitation and right ventricular dysfunction have limited therapeutic options due to anatomic complexity, advanced disease at presentation, and comorbidities. Caval valve implantation is an emerging transcatheter therapy. We present a case series of contrast-sparing caval valve implantation using intravascular ultrasound guidance in patients with renal failure. (Level of Difficulty: Advanced.).

19.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Article En | MEDLINE | ID: mdl-37988439

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/surgery , Feasibility Studies , Treatment Outcome , Tomography, X-Ray Computed , Prosthesis Design
...