Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Opt Express ; 23(26): 33396-407, 2015 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-26832004

RESUMEN

Modern diesel injectors operate at very high injection pressures of about 2000 bar resulting in injection velocities as high as 700 m/s near the nozzle outlet. In order to better predict the behavior of the atomization process at such high pressures, high-resolution spray images at high repetition rates must be recorded. However, due to extremely high velocity in the near-nozzle region, high-speed cameras fail to avoid blurring of the structures in the spray images due to their exposure time. Ultrafast imaging featuring ultra-short laser pulses to freeze the motion of the spray appears as an well suited solution to overcome this limitation. However, most commercial high-energy ultrafast sources are limited to a few kHz repetition rates. In the present work, we report the development of a custom-designed picosecond fiber laser generating ∼ 20 ps pulses with an average power of 2.5 W at a repetition rate of 8.2 MHz, suitable for high-speed imaging of high-pressure fuel jets. This fiber source has been proof tested by obtaining backlight images of diesel sprays issued from a single-orifice injector at an injection pressure of 300 bar. We observed a consequent improvement in terms of image resolution compared to standard white-light illumination. In addition, the compactness and stability against perturbations of our fiber laser system makes it particularly suitable for harsh experimental conditions.

2.
Opt Express ; 22(13): 15778-90, 2014 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-24977836

RESUMEN

Imaging with ultrashort exposure times is generally achieved with a crossed-beam geometry. In the usual arrangement, an off-axis gating pulse induces birefringence in a medium exhibiting a strong Kerr response (commonly carbon disulfide) which is followed by a polarizer aligned to fully attenuate the on-axis imaging beam. By properly timing the gate pulse, imaging light experiences a polarization change allowing time-dependent transmission through the polarizer to form an ultrashort image. The crossed-beam system is effective in generating short gate times, however, signal transmission through the system is complicated by the crossing angle of the gate and imaging beams. This work presents a robust ultrafast time-gated imaging scheme based on a combination of type-I frequency doubling and a collinear optical arrangement in carbon disulfide. We discuss spatial effects arising from crossed-beam Kerr gating, and examine the imaging spatial resolution and transmission timing affected by collinear activation of the Kerr medium, which eliminates crossing angle spatial effects and produces gate times on the order of 1 ps. In addition, the collinear, two-color system is applied to image structure in an optical fiber and a gasoline fuel spray, in order to demonstrate image formation utilizing ballistic or refracted light, selected on the basis of its transmission time.

3.
Opt Express ; 21(13): 15475-89, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23842335

RESUMEN

A novel spectroscopic Mueller matrix system has been developed and explored for both fluorescence and elastic scattering polarimetric measurements from biological tissues. The 4 × 4 Mueller matrix measurement strategy is based on sixteen spectrally resolved (λ = 400 - 800 nm) measurements performed by sequentially generating and analyzing four elliptical polarization states. Eigenvalue calibration of the system ensured high accuracy of Mueller matrix measurement over a broad wavelength range, either for forward or backscattering geometry. The system was explored for quantitative fluorescence and elastic scattering spectroscopic polarimetric studies on normal and precancerous tissue sections from human uterine cervix. The fluorescence spectroscopic Mueller matrices yielded an interesting diattenuation parameter, exhibiting differences between normal and precancerous tissues.

4.
J Biomed Opt ; 18(3): 035003, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23462968

RESUMEN

Development of methods for quantification of cellular association and patterns in growing bacterial colony is of considerable current interest, not only to help understand multicellular behavior of a bacterial species but also to facilitate detection and identification of a bacterial species in a given space and under a given set of condition(s). We have explored quantitative spectral light scattering polarimetry for probing the morphological and structural changes taking place during colony formations of growing Bacillus thuringiensis bacteria under different conditions (in normal nutrient agar representing favorable growth environment, in the presence of 1% glucose as an additional nutrient, and 3 mM sodium arsenate as toxic material). The method is based on the measurement of spectral 3×3 Mueller matrices (which involves linear polarization measurements alone) and its subsequent analysis via polar decomposition to extract the intrinsic polarization parameters. Moreover, the fractal micro-optical parameter, namely, the Hurst exponent H, is determined via fractal-Born approximation-based inverse analysis of the polarization-preserving component of the light scattering spectra. Interesting differences are noted in the derived values for the H parameter and the intrinsic polarization parameters (linear diattenuation d, linear retardance δ, and linear depolarization Δ coefficients) of the growing bacterial colonies under different conditions. The bacterial colony growing in presence of 1% glucose exhibit the strongest fractality (lowest value of H), whereas that growing in presence of 3 mM sodium arsenate showed the weakest fractality. Moreover, the values for δ and d parameters are found to be considerably higher for the colony growing in presence of glucose, indicating more structured growth pattern. These findings are corroborated further with optical microscopic studies conducted on the same samples.


Asunto(s)
Bacillus thuringiensis/fisiología , Imagen Óptica/métodos , Análisis Espectral/métodos , Bacillus thuringiensis/química , Bacillus thuringiensis/citología , Bacillus thuringiensis/crecimiento & desarrollo , Fractales , Luz , Dispersión de Radiación
5.
J Biomed Opt ; 17(10): 105006, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23064484

RESUMEN

Development of methodologies for quantification/unique interpretation of the intrinsic polarimetry characteristics of biological tissues are important for various applications involving tissue characterization/diagnosis. A detailed comparative evaluation of the polar decomposition and the differential matrix decomposition of Mueller matrices for extraction/quantification of the intrinsic polarimetry characteristics (with special emphasis on linear retardance δ, optical rotation Ψ and depolarization Δ parameters was performed, because these are the most prominent tissue polarimetry effects) from complex tissue-like turbid media exhibiting simultaneous scattering and polarization effects. The results suggest that for media exhibiting simultaneous linear retardance and optical rotation polarization events, the use of retarder polar decomposition with its associated analysis which assumes sequential occurrence of these effects, results in systematic underestimation of δ and overestimation of Ψ parameters. Analytical relationships between the polarization parameters (δ, Ψ) extracted from both the retarder polar decomposition and the differential matrix decomposition for either simultaneous or sequential occurrence of the linear retardance and optical rotation effects were derived. The self-consistency of both decompositions is validated on experimental Mueller matrices recorded from tissue-simulating phantoms (whose polarization properties are controlled, known a-priori, and exhibited simultaneously) of increasing biological complexity. Additional theoretical validation tests were performed on Monte Carlo-generated Mueller matrices from analogous turbid media exhibiting simultaneous depolarization (Δ), linear retardance (δ) and optical rotation (Ψ) effects. After successful evaluation, the potential advantage of the differential matrix decomposition over the polar decomposition formalism was explored for monitoring of myocardial tissue regeneration following stem cell therapy.


Asunto(s)
Diagnóstico por Imagen/métodos , Nefelometría y Turbidimetría/métodos , Fenómenos Ópticos , Animales , Método de Montecarlo , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/metabolismo , Miocardio/química , Miocardio/metabolismo , Fantasmas de Imagen , Ratas
6.
Opt Express ; 19(20): 19717-30, 2011 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-21996914

RESUMEN

The fluctuations in the elastic light scattering spectra of normal and dysplastic human cervical tissues analyzed through wavelet transform based techniques reveal clear signatures of self-similar behavior in the spectral fluctuations. The values of the scaling exponent observed for these tissues indicate the differences in the self-similarity for dysplastic tissues and their normal counterparts. The strong dependence of the elastic light scattering on the size distribution of the scatterers manifests in the angular variation of the scaling exponent. Interestingly, the spectral fluctuations in both these tissues showed multi-fractality (non-stationarity in fluctuations), the degree of multi-fractality being marginally higher in the case of dysplastic tissues. These findings using the multi-resolution analysis capability of the discrete wavelet transform can contribute to the recent surge in the exploration for non-invasive optical tools for pre-cancer detection.


Asunto(s)
Biomarcadores de Tumor/análisis , Diagnóstico por Computador/métodos , Luz , Lesiones Precancerosas/diagnóstico , Dispersión de Radiación , Espectrometría de Fluorescencia/métodos , Neoplasias del Cuello Uterino/diagnóstico , Adulto , Algoritmos , Femenino , Fractales , Humanos , Persona de Mediana Edad , Lesiones Precancerosas/metabolismo , Reproducibilidad de los Resultados , Neoplasias del Cuello Uterino/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA