Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
1.
Front Cardiovasc Med ; 11: 1399110, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39105074

RESUMEN

Objectives: The percentage of shunt fraction significantly impacts the management of patients with congenital shunts, influencing strategic choices such as surgical or interventional procedures. This study compared the estimated shunt fraction (the ratio of pulmonary-to-systemic flow, Qp/Qs) for quantifying the left-to-right shunt in children with ventricular septal defect (VSD) using heart catheterization, four-dimensional (4D) flow, and two-dimensional (2D) flow magnetic resonance imaging (MRI). The goal was to establish a non-invasive and reliable measurement ratio between pulmonary and systemic blood flow in these patients. Methods: Between July 2022 and June 2023, patients scheduled to undergo invasive right heart catheterization were included in this study. MRI was performed one hour before the catheterization procedure. The correlation of shunt fraction was assessed between all methods after calculating the Qp/Qs ratio from 2D and 4D flow MRI and catheterization. Results: A total of 24 patients (aged 3-15 years, eight females) were ultimately included in the study. The Qp/Qs ratios obtained from 4D flow had a robust correlation (correlation coefficient r = 0.962) compared to those obtained during catheterization. Cardiac catheterization recorded the mean shunt fraction at 1.499 ± 0.396, while 4D flow measured it at 1.403 ± 0.344, with no significant difference between the two techniques. Moreover, there was a reasonable correlation (r = 0.894) between 2D flow measurements of Qp/Qs and the results obtained from catheterization, with a mean shunt fraction of 1.326 ± 0.283. Conclusion: 4D flow MRI has the potential to be a non-invasive method for accurately measuring the left-to-right shunt in children with VSD.

2.
Orphanet J Rare Dis ; 19(1): 227, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38849913

RESUMEN

BACKGROUND: Increased arterial tortuosity has been associated with various cardiovascular complications. However, the extent and role of arterial tortuosity in non-atherosclerotic vascular diseases remain to be fully elucidated. This study aimed to assess arterial tortuosity index (ATI) in patients with non-atherosclerotic vascular diseases and the associated factors. METHODS: This is a retrospective analysis of patients with non-atherosclerotic vascular diseases referred to the Malformation and Rare Vascular Disease Center at the University Hospital in Lausanne (Switzerland). Computed tomography angiography (CTA) images performed between October 2010 and April 2022 were retrieved and the aortic tortuosity index (ATI) was calculated. Patients were classified based on diagnosis into the following groups: arterial dissection & aneurysm, arteritis & autoimmune disease, hereditary connective tissue diseases, and fibromuscular dysplasia (FMD). Univariate and multivariate logistic regression analysis was used to determine potentially relevant predictors of aortic tortuosity. RESULTS: The mean age upon computed tomography angiography (CTA) was 46.8 (standard deviation [SD] 14.6) years and 59.1% of the patients were female. Mean ATI was higher in patients over 60 years old (1.27), in those with arterial aneurysms (mean: 1.11), and in those diagnosed with hypertension (mean: 1.13). When only patients over 60 years old were considered, those diagnosed with connective tissue diseases had the highest ATI. At multivariate regression analysis, increasing age (p < 0.05), presence of arterial aneurysms (p < 0.05), and hypertension (p < 0.05) were independently associated with ATI. CONCLUSIONS: The ATI may be a promising tool in diagnostic evaluation, cardiovascular risk stratification, medical or surgical management, and prognostic assessment in several non-atherosclerotic vascular conditions. Further studies with longitudinal design and larger cohorts are needed to validate the role of ATI in the full spectrum of vascular diseases.


Asunto(s)
Aneurisma , Angiografía por Tomografía Computarizada , Hipertensión , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Hipertensión/complicaciones , Aneurisma/patología , Aneurisma/diagnóstico por imagen , Enfermedades Vasculares/patología , Enfermedades Vasculares/diagnóstico por imagen , Anciano , Arterias/patología , Arterias/diagnóstico por imagen , Factores de Edad
3.
Int J Legal Med ; 138(5): 1845-1856, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38594500

RESUMEN

High-risk coronary plaques (HRP) are characterized in clinical radiological imaging by the presence of low plaque attenuation, a napkin-ring sign (NRS), spotty calcifications (SC) and a positive remodeling index (RI). To evaluate if these signs are detectable in postmortem imaging by a multi-phase postmortem CT angiography (MPMCTA), a retrospective study of a series of autopsy well-documented coronary plaques related to sudden cardiac death (SCD) was performed. Then correlations between histological and radiological findings were described. Fourty SCD cases due to acute coronary syndrome based on clinical history and confirmed at autopsy were selected (28 men and 12 women, age 53.3 ± 10.9). The culprit lesion was mainly situated in the proximal segments of coronary arteries, in the right coronary artery in 23 cases (57.5%), the left anterior descending artery in 13 cases (32.5%), the circumflex artery in 3 cases (7.5%) and in one case in the left main stem. MPMCTA showed a positive RI (≥ 1.1) in 75% of cases with a mean RI 1.39 ± 0.71. RI values were lower in cases with fibrotic plaques. NRS was observed in 40% of cases, low attenuation plaque in 46.3%, and SC in 48.7% of cases. There were significant correlations of the radiological presence of NRS for fibrolipid composition of the plaque (p-value 0.007), severe intraplaque inflammation (p-value 0.017), severe adventitial inflammation (p-value 0.021) and an increased vasa vasorum (p-value 0.012). A significant correlation (p-value 0.002) was observed between the presence of SC at radiological examination and the presence of punctuate/fragmented calcification at histology. In addition, in 58.3% of cases, plaque enhancement was observed, which correlated with plaque inflammation and the fibrolipid composition of the plaque. The coronary artery calcium score was 314 (± 455). There was a poor agreement between stenosis of the lumen at histology versus radiology. Our study shows that the various radiological signs of HRP can be detected in all plaques by MPMCTA, but individually only to a variable extent; plaque enhancement appeared as a new sign of vulnerability. In the postmortem approach, these radiological markers of HRP, should always be applied in combination, which can be useful for developing a predictive model for diagnosing coronary SCD.


Asunto(s)
Angiografía por Tomografía Computarizada , Muerte Súbita Cardíaca , Placa Aterosclerótica , Humanos , Femenino , Muerte Súbita Cardíaca/patología , Muerte Súbita Cardíaca/etiología , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/patología , Estudios Retrospectivos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Adulto , Anciano , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Angiografía Coronaria , Autopsia , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/patología , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/patología , Patologia Forense , Fibrosis , Imágenes Post Mortem
4.
Sensors (Basel) ; 24(3)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38339610

RESUMEN

(1) Background: The peripherally inserted central catheter (PICC) is commonly used in medicine. The tip position was shown to be a major determinant in PICC function and related complications. Recent advances in ECG guidance might facilitate daily practice. This study aimed to compare two ECG techniques, in terms of their tip-position accuracy, puncture site layout, and signal quality; (2) Methods: This randomized open study (1:1) included 320 participants. One PICC guidance technique used ECG signal transmission with saline (ST); the other technique used a guidewire (WT). Techniques were compared by the distance between the catheter tip and the cavoatrial junction (DCAJ) on chest X-rays, insertion-point hemostasis time, and the extracorporeal catheter length between the hub and the insertion point; (3) Results: The mean DCAJs were significantly different between ST (1.36 cm, 95% CI: 1.22-1.37) and WT (1.12 cm, 95% CI: 0.98-1.25; p = 0.013) groups. When DCAJs were classified as optimal, suboptimal, or inadequate, the difference between techniques had limited clinical impact (p = 0.085). However, the hemostasis time at the puncture site was significantly better with WT (no delay in 82% of patients) compared to ST (no delay in 50% of patients; p < 0.001). Conversely, ST achieved optimal and suboptimal extracorporeal lengths significantly more frequently than WT (100% vs. 66%; p < 0.001); (4) Conclusions: ECG guidance technologies achieved significantly different tip placements, but the difference had minimal clinical impact. Nevertheless, each technique displayed an important drawback at the PICC insertion point: the extracorporeal catheter was significantly longer with WT and the hemostasis delay was significantly longer with ST.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Humanos , Cateterismo Venoso Central/métodos , Radiografía , Punciones , Electrocardiografía
5.
Eur Radiol ; 34(3): 1755-1763, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658143

RESUMEN

OBJECTIVES: To evaluate the diagnostic utility of multiphase postmortem CT angiography (PMCTA) to detect plaque enhancement as a surrogate marker of inflammation, using fatal coronary plaques obtained from autopsies following sudden cardiac death. METHODS: In this retrospective study, we included 35 cases (12 women, 34%; median [IQR] age, 52 [11] years), with autopsy-proven coronary thrombosis, histological examination, and multiphase PMCTA. Two radiologists blinded towards histological findings assessed PMCTA for plaque enhancement of the culprit lesion in consensus. Two forensic pathologists determined the culprit lesion and assessed histological samples in consensus. Cases with concomitant vasa vasorum density increase and intraplaque and periadventital inflammation were considered positive for plaque inflammation. Finally, we correlated radiology and pathology findings. RESULTS: All 35 cases had histological evidence of atherosclerotic plaque disruption and thrombosis; 30 (85.7%) had plaque inflammation. Plaque enhancement at multiphase PMCTA was reported in 21 (60%) and resulted in a PPV of 95.2% (77.3-99.2%) and an NPV of 28.6% (17-43.9%). Median histological ratings indicated higher intraplaque inflammation (p = .024) and vasa vasorum density (p = .032) in plaques with enhancement. We found no evidence of a difference in adventitial inflammation between CT-negative and CT-positive plaques (p = .211). CONCLUSIONS: Plaque enhancement was found in 2/3 of fatal atherothrombotic occlusions at coronary postmortem CT angiography. Furthermore, plaque enhancement correlated with histopathological plaque inflammation and increased vasa vasorum density. Plaque enhancement on multiphase CT angiography could potentially serve as a noninvasive marker of inflammation in high-risk populations. CLINICAL RELEVANCE STATEMENT: Phenotyping coronary plaque more comprehensively is one of the principal challenges cardiac imaging is facing. Translating our ex vivo findings of CT-based plaque inflammation assessment into clinical studies might help pave the way in defining high-risk plaque better. KEY POINTS: • Most thrombosed coronary plaques leading to fatality in our series had histological signs of inflammation. • Multiphase postmortem CT angiography can provide a noninvasive interrogation of plaque inflammation through contrast enhancement. • Atherosclerotic plaque enhancement at multiphase postmortem CT angiography correlated with histopathological signs of plaque inflammation and could potentially serve as an imaging biological marker of plaque vulnerability.


Asunto(s)
Enfermedad de la Arteria Coronaria , Placa Aterosclerótica , Humanos , Femenino , Persona de Mediana Edad , Placa Aterosclerótica/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Estudios Retrospectivos , Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X , Inflamación/diagnóstico por imagen , Autopsia , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología
6.
J Cardiovasc Dev Dis ; 10(10)2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37887871

RESUMEN

BACKGROUND: Coronary CT angiography (CCTA) is increasingly used as a non-invasive tool to assess coronary artery disease (CAD). However, CCTA is subject to motion artifacts, potentially limiting its clinical utility. Despite faster (0.35 and 0.28 s/rot) gantry rotation times, low (60-65 bpm) heartbeat is recommended, and the use of ß-blockers is often needed. Technological advancements have resulted in the development of faster rotation speeds (0.23 s/rot). However, their added value in patients not premedicated with ß-blockers remains unclear. This prospective single-center, two-arm, randomized, controlled trial aims to assess the influence of fast rotation on coronary motion artifacts, diagnostic accuracy of CCTA for CAD, and patient safety. METHODS: We will randomize a total of 142 patients aged ≥ 50 scheduled for an aortic stenosis work-up to receive CCTA with either a fast (0.23) or standard (0.28 s/rot) gantry speed. PRIMARY OUTCOME: rate of CCTAs with coronary motion artifacts hindering interpretation. SECONDARY OUTCOMES: assessable coronary segments rate, diagnostic accuracy against invasive coronary angiography (ICA), motion artifact magnitude per segment, contrast-to-noise ratio (CNR), and patient ionizing radiation dose. The local ethics committee has approved the protocol. Potential significance: FAST-CCT may improve motion artifact reduction and diagnosis quality, thus eliminating the need for rate control and ß-blocker administration. CLINICALTRIALS: gov identifier: NCT05709652.

8.
Front Med (Lausanne) ; 10: 1117151, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37035332

RESUMEN

Background: Pulmonary manifestations of COVID-19 pneumonia are well known. However, COVID-19 is also associated with a range of vascular manifestations such as embolism, congestion, and perfusion changes. Regarding congestion, research from different groups has suggested arteriovenous anastomosis dysregulation as a contributing factor. In this study, we aim to better describe the changes in vascular volume in affected lung zones and to relate them to pathophysiological hypotheses. Methods: We performed automatic vascular volume extraction in 10 chest CTs of patients, including 2 female and 8 male with a mean age of 63.5 ± 9.3 years, diagnosed with COVID-19 pneumonia. We compared the proportion of vascular volumes between manually segmented regions of lung parenchyma with and without signs of pneumonia. Results: The proportion of vascular volume was significantly higher in COVID (CVasc) compared to non-COVID (NCVasc) areas. We found a mean difference (DVasc) of 5% and a mean ratio (RVasc) of 3.7 between the two compartments (p < 0.01). Conclusion: Vascular volume in COVID-19 affected lung parenchyma is augmented relative to normal lung parenchyma, indicating venous congestion and supporting the hypothesis of pre-existing intra-pulmonary arteriovenous shunts.

9.
Cardiovasc Intervent Radiol ; 46(6): 786-793, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36944851

RESUMEN

PURPOSE: Hypnosis is useful for diminishing distress during medical procedures. This study investigated the efficacy of virtually augmented self-hypnosis as an adjunctive non-pharmacological method for procedural pain and anxiety relief during endovascular interventions (EVI). METHODS: We compared an immersive distraction experience (clinicaltrials.gov identifier NCT04561596) featuring virtual reality (VR) using a head-mounted display versus treatment as usual (TAU). Patients followed the "Aqua" module (Oncomfort™) consisting of a scuba dive and breathing exercises. They experienced a self-induced dissociative state similar to clinical hypnosis without direct intervention of a professional. Enrollment followed a 1:1 randomized open study (VR or TAU). Patients' feelings were evaluated just before and after the procedure, and 3 months following intervention. Anxiety was evaluated using the State Trait Anxiety Inventory (STAI) and pain (sensory, emotional, and memory) with a visual analogue scale (VAS). RESULTS: This study included 100 patients. Mean anxiety (pre-post) was significantly reduced within groups and between groups (difference of 4.2 points, p = 0.016). The percentage of responders to anxiety lowering were 76 and 46% for VR and TAU, respectively (p = 0.004). The two groups did not significantly differ in mean sensory-intensity and affective emotional pain (pre-post) using VAS, in negative memories concerning remembered pain at 3 months (difference > 1 from immediate post-procedural reported pain intensity), mean procedural time, or the need for analgesic or sedative drugs. CONCLUSIONS: VR self-hypnosis has the potential to improve the management of patients' distress during radiological procedures. It is safe and effective for reducing anxiety during EVI.


Asunto(s)
Hipnosis , Dolor Asociado a Procedimientos Médicos , Realidad Virtual , Humanos , Dolor , Dolor Asociado a Procedimientos Médicos/psicología , Dolor Asociado a Procedimientos Médicos/terapia , Ansiedad/prevención & control , Ansiedad/psicología , Hipnosis/métodos
10.
Biomolecules ; 13(2)2023 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-36830766

RESUMEN

We read with great interest the review by Wang et al. entitled "Identification Markers of Carotid Vulnerable Plaques: An Update", recently published in Biomolecules [...].


Asunto(s)
Arterias Carótidas , Placa Aterosclerótica , Humanos , Imagen por Resonancia Magnética/métodos , Placa Amiloide , Tomografía Computarizada por Rayos X
11.
Materials (Basel) ; 16(4)2023 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-36837126

RESUMEN

In this paper, a wideband antenna is proposed for ultra-wideband microwave imaging applications. The antenna is comprised of a tapered slot ground, a rectangular slotted patch and four star-shaped parasitic components. The added slotted patch is shown to be effective in improving the bandwidth and gain. The proposed antenna system provides a realized gain of 6 dBi, an efficiency of around 80% on the radiation bandwidth, and a wide impedance bandwidth (S11 < -10 dB) of 6.3 GHz (from 3.8 to 10.1 GHz). This supports a true wideband operation. Furthermore, the fidelity factor for face-to-face (FtF) direction is 91.6%, and for side by side (SbS) is 91.2%. This proves the excellent directionality and less signal distortion of the designed antenna. These high figures establish the potential use of the proposed antenna for imaging. A heterogeneous breast phantom with dielectric characteristics identical to actual breast tissue with the presence of tumors was constructed for experimental validation. An antenna array of the proposed antenna element was situated over an artificial breast to collect reflected and transmitted waves for tumor characterization. Finally, an imaging algorithm was used to process the retrieved data to recreate the image in order to detect the undesirable tumor object inside the breast phantom.

12.
Front Cardiovasc Med ; 10: 1102063, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36742076

RESUMEN

Pelvic venous disorders (PeVD), sometimes referred to as pelvic congestion syndrome (PCS), widely impact affected patients-mainly young women's quality of life, causing puzzling, uncomfortable symptoms sometimes requiring months or years to get an explanation, while simply remaining undiagnosed in other cases. Because pelvic pain is a non-specific symptom, an appropriate diagnosis requires a careful patient workup, including a correlation between history and non-invasive imaging. Invasive imaging is frequently required to confirm the diagnosis and plan treatment. Current therapeutic approaches principally rely on minimally invasive techniques delivered through endovascular access. However, while comprehensive descriptive classifications such as the symptoms-varices-pathophysiology (SVP) classification exist, universally accepted guidelines regarding therapy to apply for each SVP category are still lacking. This review strongly focuses on PeVD imaging and discusses available therapeutic approaches with regard to pathophysiological mechanisms. It proposes a new classification scheme assisting clinical decision-making about endovascular management to help standardize the link between imaging findings and treatment.

13.
Artículo en Inglés | MEDLINE | ID: mdl-36579415

RESUMEN

Noninvasive methods of estimating invasively measured fractional flow reserve (FFRinvasive ) are actively being explored, aiming to avoid the use of an invasive pressure wire and the administration of hyperemia-inducing drugs. Coronary angiography-derived FFR (FFRangio ) has already demonstrated its diagnostic performance in the context of stable coronary artery disease. However, its applicability in the context of non-ST-segment elevation myocardial infarction (NSTEMI) has yet to be established. We sought to determine the diagnostic performance of FFRangio exclusively in patients presenting with NSTEMI. We performed a prospective, single-center, single-arm, double-blinded study comparing FFR calculated by FFRangio to FFRinvasive in NSTEMI patients. FFRinvasive was measured in all angiographically intermediate lesions (30%-70% stenosis) and was then compared to FFRangio which was calculated at the same position, by a blinded operator. The primary endpoints were the sensitivity and specificity of FFRangio for predicting FFRinvasive using a cut-off value of ≤0.80. Among 100 NSTEMI patients who were screened, 46 patients with 60 vessels in total underwent FFRinvasive and were included in the study. The mean value of FFRinvasive was 0.83 ± 0.3 with 22 (36%) being ≤0.80 while the mean FFRangio was 0.82 ± 0.1 with 22 (36%) being ≤0.80. FFRangio exhibited a sensitivity of 95.5%, a specificity of 97.4%, and a diagnostic accuracy of 96.7%. FFRangio can precisely and noninvasively estimate FFRinvasive in acute coronary syndromes and may have a role in guiding treatment decisions related to angiographically intermediate coronary lesions in this context. WHAT IS KNOWN: FFRangio has demonstrated its diagnostic performance in validation studies, as a noninvasive and cost-effective method in the context of stable coronary artery disease but its performance has never been exclusively evaluated in NSTEMI patients. WHAT IS NEW: The present prospective single-center study demonstrates the excellent diagnostic performance of FFRangio in detecting functionally significant coronary artery stenosis in the setting of NSTEMI, providing more confidence in utilizing FFRangio in this population, avoiding the risk of an invasive pressure wire and the administration of hyperemia-inducing drugs. WHAT IS NEXT: Future randomized trials evaluating FFRangio -guided treatment of coronary artery disease (stable or ACS) are now needed to definitively establish the role of FFRangio in the physiological assessment of coronary lesions.

14.
Front Cardiovasc Med ; 9: 898467, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36337865

RESUMEN

Congenital coronary anomalies are among the rare disorders of the otherwise normal heart. A 2-year-old toddler was evaluated for de novo heart failure after a flu-like event 2 months before being suspicious of post-Covid-19 dilated cardiomyopathy. The cardiac magnetic resonance (CMR) technique displayed the basal to mid subendocardial to transmural scar, suggestive of an ischemic etiology. Further assessment with CT and invasive angiography confirmed the very uncommon left main coronary artery atresia (LMCAA) as the main cause of the patient's heart failure. This is not only the first reported LMCAA case that had undergone a CMR study but was also initially suspected with characteristic CMR findings.

16.
Front Cardiovasc Med ; 9: 835655, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35865383

RESUMEN

Purpose: To evaluate the correlation between whole lung enhancement (WLE) and pulmonary blood volume (PBV) obtained through dual energy computed tomography pulmonary angiography (DECTPA) and echocardiography-derived systolic pulmonary arterial pressure (SPAP). Methods: Sixty-eight patients who underwent DECTPA were enrolled in the study after giving informed consent. A transthoracic echocardiography was performed for all the subjects within 48 h of their DECTPA study to measure SPAP. The correlation of the two DECTPA-derived parameters, WLE and PBV, with SPAP was assessed. In addition, the predictive strength of these parameters was compared with that of traditional computed tomography (CT) signs of pulmonary hypertension (PH). Results: The SPAP value showed a moderate correlation with main pulmonary artery (MPA) diameter (r = 0.48, P < 0.001), while having a weak correlation with WLE (r = -0.33, P = 0.007), PBV (r = -0.31, P = 0.01) and MPA/ascending aorta (MPA/AA) ratio (r = 0.26, P = 0.03). On regression analysis, MPA diameter (B ± SE: 1.8 ± 0.6, P = 0.004) and WLE (B ± SE: -0.5 ± 0.3, P = 0.042) had significant association with SPAP. In addition, SPAP ≥30 mmHg was related to the right to left ventricular diameter (RV/LV) ratio [OR (CI 95%): 24.39 (1.3-573.2), P = 0.04] and reversely associated with PBV [OR (CI 95%): 0.96 (0.93-0.98), P = 0.005]. Acquired cutoff value of 83% for PBV showed sensitivity and specificity of 73% to identify SPAP ≥30 mmHg [AUC (CI 95%):0.727 (0.588-0.866), P = 0.008]. Conclusions: Automated postprocessing calculation of iodine distribution analysis by DECTPA could be considered as an adjunctive tool to investigate for PH.

17.
J Cardiovasc Comput Tomogr ; 16(6): 517-523, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35872138

RESUMEN

BACKGROUND: Selection of the transcatheter heart valve size for a mitral valve-in-valve procedure is based on the type and manufacturer's labelled size. However, accurate information of surgical heart valve (SHV) size may not be available in the patient's medical record. The purpose of this study is to establish reference data for computed tomography (CT) dimensions of commonly used mitral SHV in order to determine the manufacturer's labelled size from a cardiac CT data set. METHODS: CT datasets of 105 patients with surgical mitral bioprosthesis and available manufacturer labeled datasets were included in the analysis. CT derived valve dimensions were assessed by two observers using multiplanar reformats aligned with the basal sewing ring. A circular region of interest was used in a standardized fashion to minimize influence of image acquisition and reconstruction parameters. Interobserver variability was assessed by Bland-Altman analysis. RESULTS: The CT-derived dimensions were stratified by valve size and type, and SHV properties were demonstrated for 5 common valve types. Variability of measurements was small and inter-observer limits of agreement were narrow. Stratified by SHV type, no overlap was noted for CT-derived dimensions among different SHV sizes . A reference table of CT characteristics of surgical mitral bioprosthesis types was created. CONCLUSION: The study provides reference CT data for determining the manufacturers' labeled SHV size across a range of commonly used mitral SHVs. The findings will be important to help identify types of surgical mitral bioprosthesis utilizing CT characteristics for patients without SHV size documentation.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Diseño de Prótesis , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
18.
Biomedicines ; 10(6)2022 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-35740322

RESUMEN

Background: Vascular abnormalities, including venous congestion (VC) and pulmonary embolism (PE), have been recognized as frequent COVID-19 imaging patterns and proposed as severity markers. However, the underlying pathophysiological mechanisms remain unclear. In this study, we aimed to characterize the relationship between VC, PE distribution, and alveolar opacities (AO). Methods: This multicenter observational registry (clinicaltrials.gov identifier NCT04824313) included 268 patients diagnosed with SARS-CoV-2 infection and subjected to contrast-enhanced CT between March and June 2020. Acute PE was diagnosed in 61 (22.8%) patients, including 17 females (27.9%), at a mean age of 61.7 ± 14.2 years. Demographic, laboratory, and outcome data were retrieved. We analyzed CT images at the segmental level regarding VC (qualitatively and quantitatively [diameter]), AO (semi-quantitatively as absent, <50%, or >50% involvement), clot location, and distribution related to VC and AO. Segments with vs. without PE were compared. Results: Out of 411 emboli, 82 (20%) were lobar or more proximal and 329 (80%) were segmental or subsegmental. Venous diameters were significantly higher in segments with AO (p = 0.031), unlike arteries (p = 0.138). At the segmental level, 77% of emboli were associated with VC. Overall, PE occurred in 28.2% of segments with AO vs. 21.8% without (p = 0.047). In the absence of VC, however, AO did not affect PE rates (p = 0.94). Conclusions: Vascular changes predominantly affected veins, and most PEs were located in segments with VC. In the absence of VC, AOs were not associated with the PE rate. VC might result from increased flow supported by the hypothesis of pulmonary arteriovenous anastomosis dysregulation as a relevant contributing factor.

19.
Front Cardiovasc Med ; 9: 765935, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35600463

RESUMEN

Intracavitary electrocardiography is an accurate guidance technique for peripherally inserted central catheters (PICC) tip location that is spreading widely among providers using non x-ray-based facilities. The principle behind this technology relies on the transmission of the electrocardiographic signal at the tip of the catheter and its use as an internal mobile electrode, allowing the system to identify the cavo-atrial junction (CAJ) through internal P-wave amplitude modulations. The gain in popularity of intracavitary electrography and its large diffusion have led manufacturers to offer various devices with heterogeneous properties, among which clinician who place PICCs have to choose. It is therefore important to understand differences between available techniques and devices. The potential impact might not only affect availability and costs but also the clinical impact through advantages and limitations regarding electric signal transmission PICC selection. Current perspectives on intracavitary electrocardiography will also be discussed, to give the reader a global view of the management of electrocardiographically guided PICCs, especially in an environment without x-ray support.

20.
J Cardiovasc Dev Dis ; 9(5)2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35621848

RESUMEN

Advances in computed tomography (CT) have resulted in a substantial increase in the size of datasets. We built a new concept of medical image compression that provides the best compromise between compression rate and image quality. The method is based on multiple contexts and regions-of-interest (ROI) defined according to the degree of clinical interest. High priority areas (primary ROIs) are assigned a lossless compression. Other areas (secondary ROIs and background) are compressed with moderate or heavy losses. The method is applied to a whole dataset of CT angiography (CTA) of the lower extremity vasculature. It is compared to standard lossy compression techniques in terms of quantitative and qualitative image quality. It is also compared to standard lossless compression techniques in terms of image size reduction and compression ratio. The proposed compression method met quantitative criteria for high-quality encoding. It obtained the highest qualitative image quality rating score, with a statistically significant difference compared to other methods. The average compressed image size was up to 61% lower compared to standard compression techniques, with a 9:1 compression ratio compared with original non-compressed images. Our new adaptive 3D compression method for CT images can save data storage space while preserving clinically relevant information.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA