Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Chest ; 163(2): 444-454, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36087795

RESUMEN

BACKGROUND: Solitary pulmonary nodules (SPNs) measuring 8 to 30 mm in diameter require further workup to determine the likelihood of malignancy. RESEARCH QUESTION: What is the diagnostic performance of a lung cancer prediction convolutional neural network (LCP-CNN) in SPNs using unenhanced and contrast-enhanced CT imaging compared with the current clinical workup? STUDY DESIGN AND METHODS: This was a post hoc analysis of the Single Pulmonary Nodule Investigation: Accuracy and Cost-Effectiveness of Dynamic Contrast Enhanced Computed Tomography in the Characterisation of Solitary Pulmonary Nodules trial, a prospective multicenter study comparing the diagnostic accuracy of dynamic contrast-enhanced (DCE) CT imaging with PET imaging in SPNs. The LCP-CNN was designed and validated in an external cohort. LCP-CNN-generated risk scores were created from the noncontrast and contrast-enhanced CT scan images from the DCE CT imaging. The gold standard was histologic analysis or 2 years of follow-up. The area under the receiver operating characteristic curves (AUC) were calculated using LCP-CNN score, maximum standardized uptake value, and DCE CT scan maximum enhancement and were compared using the DeLong test. RESULTS: Two hundred seventy participants (mean ± SD age, 68.3 ± 8.8 years; 49% women) underwent PET with CT scan imaging and DCE CT imaging with CT scan data available centrally for LCP-CNN analysis. The accuracy of the LCP-CNN on the noncontrast images (AUC, 0.83; 95% CI, 0.79-0.88) was superior to that of DCE CT imaging (AUC, 0.76; 95% CI, 0.69-0.82; P = .03) and equal to that of PET with CT scan imaging (AUC, 0.86; 95% CI, 0.81-0.90; P = .35). The presence of contrast resulted in a small reduction in diagnostic accuracy, with the AUC falling from 0.83 (95% CI, 0.79-0.88) on the noncontrast images to 0.80 to 0.83 after contrast (P < .05 for 240 s after contrast only). INTERPRETATION: An LCP-CNN algorithm provides an AUC equivalent to PET with CT scan imaging in the diagnosis of solitary pulmonary nodules. TRIAL REGISTRATION: ClinicalTrials.gov Identifier; No.: NCT02013063.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Nódulo Pulmonar Solitario/patología , Estudios Prospectivos , Radiofármacos , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pulmonares/diagnóstico , Tomografía de Emisión de Positrones , Redes Neurales de la Computación , Sensibilidad y Especificidad
2.
Health Technol Assess ; 26(17): 1-180, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35289267

RESUMEN

BACKGROUND: Current pathways recommend positron emission tomography-computerised tomography for the characterisation of solitary pulmonary nodules. Dynamic contrast-enhanced computerised tomography may be a more cost-effective approach. OBJECTIVES: To determine the diagnostic performances of dynamic contrast-enhanced computerised tomography and positron emission tomography-computerised tomography in the NHS for solitary pulmonary nodules. Systematic reviews and a health economic evaluation contributed to the decision-analytic modelling to assess the likely costs and health outcomes resulting from incorporation of dynamic contrast-enhanced computerised tomography into management strategies. DESIGN: Multicentre comparative accuracy trial. SETTING: Secondary or tertiary outpatient settings at 16 hospitals in the UK. PARTICIPANTS: Participants with solitary pulmonary nodules of ≥ 8 mm and of ≤ 30 mm in size with no malignancy in the previous 2 years were included. INTERVENTIONS: Baseline positron emission tomography-computerised tomography and dynamic contrast-enhanced computer tomography with 2 years' follow-up. MAIN OUTCOME MEASURES: Primary outcome measures were sensitivity, specificity and diagnostic accuracy for positron emission tomography-computerised tomography and dynamic contrast-enhanced computerised tomography. Incremental cost-effectiveness ratios compared management strategies that used dynamic contrast-enhanced computerised tomography with management strategies that did not use dynamic contrast-enhanced computerised tomography. RESULTS: A total of 380 patients were recruited (median age 69 years). Of 312 patients with matched dynamic contrast-enhanced computer tomography and positron emission tomography-computerised tomography examinations, 191 (61%) were cancer patients. The sensitivity, specificity and diagnostic accuracy for positron emission tomography-computerised tomography and dynamic contrast-enhanced computer tomography were 72.8% (95% confidence interval 66.1% to 78.6%), 81.8% (95% confidence interval 74.0% to 87.7%), 76.3% (95% confidence interval 71.3% to 80.7%) and 95.3% (95% confidence interval 91.3% to 97.5%), 29.8% (95% confidence interval 22.3% to 38.4%) and 69.9% (95% confidence interval 64.6% to 74.7%), respectively. Exploratory modelling showed that maximum standardised uptake values had the best diagnostic accuracy, with an area under the curve of 0.87, which increased to 0.90 if combined with dynamic contrast-enhanced computerised tomography peak enhancement. The economic analysis showed that, over 24 months, dynamic contrast-enhanced computerised tomography was less costly (£3305, 95% confidence interval £2952 to £3746) than positron emission tomography-computerised tomography (£4013, 95% confidence interval £3673 to £4498) or a strategy combining the two tests (£4058, 95% confidence interval £3702 to £4547). Positron emission tomography-computerised tomography led to more patients with malignant nodules being correctly managed, 0.44 on average (95% confidence interval 0.39 to 0.49), compared with 0.40 (95% confidence interval 0.35 to 0.45); using both tests further increased this (0.47, 95% confidence interval 0.42 to 0.51). LIMITATIONS: The high prevalence of malignancy in nodules observed in this trial, compared with that observed in nodules identified within screening programmes, limits the generalisation of the current results to nodules identified by screening. CONCLUSIONS: Findings from this research indicate that positron emission tomography-computerised tomography is more accurate than dynamic contrast-enhanced computerised tomography for the characterisation of solitary pulmonary nodules. A combination of maximum standardised uptake value and peak enhancement had the highest accuracy with a small increase in costs. Findings from this research also indicate that a combined positron emission tomography-dynamic contrast-enhanced computerised tomography approach with a slightly higher willingness to pay to avoid missing small cancers or to avoid a 'watch and wait' policy may be an approach to consider. FUTURE WORK: Integration of the dynamic contrast-enhanced component into the positron emission tomography-computerised tomography examination and the feasibility of dynamic contrast-enhanced computerised tomography at lung screening for the characterisation of solitary pulmonary nodules should be explored, together with a lower radiation dose protocol. STUDY REGISTRATION: This study is registered as PROSPERO CRD42018112215 and CRD42019124299, and the trial is registered as ISRCTN30784948 and ClinicalTrials.gov NCT02013063. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 26, No. 17. See the NIHR Journals Library website for further project information.


A nodule found on a lung scan can cause concern as it may be a sign of cancer. Finding lung cancer nodules when they are small (i.e. < 3 cm) is very important. Most nodules are not cancerous. Computerised tomography (cross-sectional images created from multiple X-rays) and positron emission tomography­computerised tomography (a technique that uses a radioactive tracer combined with computerised tomography) are used to see whether or not a nodule is cancerous; although they perform well, improvements are required. This study compared dynamic contrast-enhanced computerised tomography with positron emission tomography­computerised tomography scans to find out which test is best. Dynamic contrast-enhanced computerised tomography involves injection of a special dye into the bloodstream, followed by repeated scans of the nodule over several minutes. We assessed the costs to the NHS of undertaking the different scans, relative to their benefits, to judge which option was the best value for money. We recruited 380 patients from 16 hospitals across England and Scotland, of whom 312 had both dynamic contrast-enhanced computerised tomography and positron emission tomography­computerised tomography scans. We found that current positron emission tomography­computerised tomography is more accurate, providing a correct diagnosis in 76% of cases, than the new dynamic contrast-enhanced computerised tomography, which provides a correct diagnosis in 70% of cases. Although dynamic contrast-enhanced computerised tomography cannot replace positron emission tomography­computerised tomography, it may represent good-value use of NHS resources, especially if it is performed before positron emission tomography­computerised tomography and they are used in combination. Although more research is required, it may be possible in the future to perform dynamic contrast-enhanced computerised tomography at the same time as positron emission tomography­computerised tomography in patients with suspected lung cancer or if a lung nodule is found on a lung screening programme at the time of the computerised tomography examination. This may reduce the need for some people to have positron emission tomography­computerised tomography.


Asunto(s)
Nódulo Pulmonar Solitario , Anciano , Análisis Costo-Beneficio , Humanos , Tomografía de Emisión de Positrones , Nódulo Pulmonar Solitario/diagnóstico por imagen , Evaluación de la Tecnología Biomédica , Tomografía Computarizada por Rayos X
3.
Thorax ; 77(10): 988-996, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34887348

RESUMEN

INTRODUCTION: Dynamic contrast-enhanced CT (DCE-CT) and positron emission tomography/CT (PET/CT) have a high reported accuracy for the diagnosis of malignancy in solitary pulmonary nodules (SPNs). The aim of this study was to compare the accuracy and cost-effectiveness of these. METHODS: In this prospective multicentre trial, 380 participants with an SPN (8-30 mm) and no recent history of malignancy underwent DCE-CT and PET/CT. All patients underwent either biopsy with histological diagnosis or completed CT follow-up. Primary outcome measures were sensitivity, specificity and overall diagnostic accuracy for PET/CT and DCE-CT. Costs and cost-effectiveness were estimated from a healthcare provider perspective using a decision-model. RESULTS: 312 participants (47% female, 68.1±9.0 years) completed the study, with 61% rate of malignancy at 2 years. The sensitivity, specificity, positive predictive value and negative predictive values for DCE-CT were 95.3% (95% CI 91.3 to 97.5), 29.8% (95% CI 22.3 to 38.4), 68.2% (95% CI 62.4% to 73.5%) and 80.0% (95% CI 66.2 to 89.1), respectively, and for PET/CT were 79.1% (95% CI 72.7 to 84.2), 81.8% (95% CI 74.0 to 87.7), 87.3% (95% CI 81.5 to 91.5) and 71.2% (95% CI 63.2 to 78.1). The area under the receiver operator characteristic curve (AUROC) for DCE-CT and PET/CT was 0.62 (95% CI 0.58 to 0.67) and 0.80 (95% CI 0.76 to 0.85), respectively (p<0.001). Combined results significantly increased diagnostic accuracy over PET/CT alone (AUROC=0.90 (95% CI 0.86 to 0.93), p<0.001). DCE-CT was preferred when the willingness to pay per incremental cost per correctly treated malignancy was below £9000. Above £15 500 a combined approach was preferred. CONCLUSIONS: PET/CT has a superior diagnostic accuracy to DCE-CT for the diagnosis of SPNs. Combining both techniques improves the diagnostic accuracy over either test alone and could be cost-effective. TRIAL REGISTRATION NUMBER: NCT02013063.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Humanos , Femenino , Masculino , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Análisis Costo-Beneficio , Estudios Prospectivos , Fluorodesoxiglucosa F18 , Tomografía Computarizada por Rayos X/métodos , Tomografía de Emisión de Positrones/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Radiofármacos , Sensibilidad y Especificidad
4.
Eur Radiol ; 30(6): 3310-3323, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32060716

RESUMEN

INTRODUCTION: A systematic review and meta-analysis were performed to determine the diagnostic performance of dynamic contrast-enhanced computed tomography (DCE-CT) for the differentiation between malignant and benign pulmonary nodules. METHODS: Ovid MEDLINE and EMBASE were searched for studies published up to October 2018 on the diagnostic accuracy of DCE-CT for the characterisation of pulmonary nodules. For the index test, studies with a minimum of a pre- and post-contrast computed tomography scan were evaluated. Studies with a reference standard of biopsy for malignancy, and biopsy or 2-year follow-up for benign disease were included. Study bias was assessed using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies). The sensitivities, specificities, and diagnostic odds ratios were determined along with 95% confidence intervals (CIs) using a bivariate random effects model. RESULTS: Twenty-three studies were included, including 2397 study participants with 2514 nodules of which 55.3% were malignant (1389/2514). The pooled accuracy results were sensitivity 94.8% (95% CI 91.5; 96.9), specificity 75.5% (69.4; 80.6), and diagnostic odds ratio 56.6 (24.2-88.9). QUADAS 2 assessment showed intermediate/high risk of bias in a large proportion of the studies (52-78% across the domains). No difference was present in sensitivity or specificity between subgroups when studies were split based on CT technique, sample size, nodule size, or publication date. CONCLUSION: DCE-CT has a high diagnostic accuracy for the diagnosis of pulmonary nodules although study quality was indeterminate in a large number of cases. KEY POINTS: • The pooled accuracy results were sensitivity 95.1% and specificity 73.8% although individual studies showed wide ranges of values. • This is comparable to the results of previous meta-analyses of PET/CT (positron emission tomography/computed tomography) diagnostic accuracy for the diagnosis of solitary pulmonary nodules. • Robust direct comparative accuracy and cost-effectiveness studies are warranted to determine the optimal use of DCE-CT and PET/CT in the diagnosis of SPNs.


Asunto(s)
Fluorodesoxiglucosa F18/farmacología , Neoplasias Pulmonares/diagnóstico , Nódulos Pulmonares Múltiples/diagnóstico , Nódulo Pulmonar Solitario/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Humanos , Radiofármacos/farmacología
5.
Cancer Imaging ; 16(1): 16, 2016 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-27430260

RESUMEN

Incidental indeterminate solitary pulmonary nodules (SPN) that measure less than 3 cm in size are an increasingly common finding on computed tomography (CT) worldwide. Once identified there are a number of imaging strategies that can be performed to help with nodule characterization. These include interval CT, dynamic contrast enhanced computed tomography (DCE-CT), (18)F-fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET-CT). To date the most cost effective and efficient non-invasive test or combination of tests for optimal nodule characterization has yet to be determined.DCE-CT is a functional test that involves the acquisition of a dynamic series of images of a nodule before and following the administration of intravenous iodinated contrast medium. This article provides an overview of the current indications and limitations of DCE- CT in nodule characterization and a systematic approach to how to perform, analyse and interpret a DCE-CT scan.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Fluorodesoxiglucosa F18 , Humanos , Radiofármacos
6.
Clin Med (Lond) ; 13 Suppl 6: s36-40, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24298181

RESUMEN

With the advent of multi-detector computed tomography, the identification of solitary pulmonary nodules is becoming ever more common. Although the prevalence of malignancy in a high risk population is only 1-1.5%, accurate identification of malignant nodules is essential to allow optimal treatment. In this article we review the most common causes of solitary pulmonary nodules and discuss diagnostic algorithms as well as some of the novel diagnostic imaging techniques in development.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Algoritmos , Manejo de la Enfermedad , Humanos , Prevalencia , Tomografía Computarizada por Rayos X
8.
Ultrasound Med Biol ; 37(11): 1747-54, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21963035

RESUMEN

We proposed to assess the feasibility of low mechanical index (MI) contrast enhanced ultrasound (CEUS) in the characterisation of thoracic lesions. Fifty patients were prospectively examined by CEUS and images acquired on a low MI (0.17-0.24) setting following injection of SonoVue. From region-of-interest (ROI) generated signal intensity (SI) time curves, the maximum SI, bolus arrival time (BAT), time to peak intensity (TTP), wash-in slope and mean transit time (MTT) were calculated. Using the Wilcoxon rank test; parameters and threshold values for positive differentiation were determined. In addition, for the parameters that allowed positive differentiation between malignant and benign lesions receiver operator curves (ROC) were obtained. The wash-in slope, TTP and MTT (p = 0.0003, <0.0001, 0.02) allowed positive differentiation. The sensitivity and specificity was 93% and 78%, with 6.87 s(-1) threshold value for the wash-in slope, 78% and 89% with 11.84 s threshold for the TTP and 48% and 89% with 78.6 s threshold for the MTT. CEUS is a useful tool for differentiating malignant and benign thoracic lesions.


Asunto(s)
Medios de Contraste , Fosfolípidos , Hexafluoruro de Azufre , Enfermedades Torácicas/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/farmacocinética , Diagnóstico Diferencial , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fosfolípidos/farmacocinética , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Estadísticas no Paramétricas , Hexafluoruro de Azufre/farmacocinética , Ultrasonografía
9.
J Thorac Imaging ; 21(4): 259-64, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17110849

RESUMEN

Avian influenza is caused by the H5N1 subtype of the influenza A virus. Human transmission is either directly through close contact with infected birds usually poultry or their secretions. To date 178 people throughout South East Asia have been infected with 85 deaths. Patients usually present with a rapidly progressive pneumonia that can result in respiratory failure and acute respiratory distress syndrome. The chest radiograph therefore remains the most convenient and accessible imaging modality. Studies have shown that most radiographs are abnormal at the time of presentation with multifocal consolidation the commonest radiographic finding. During the course of disease, pleural effusions and cavitation can also develop. Consolidation that involves > or = 4 zones on presentation or at day 7 after the onset of symptoms and subsequent development of acute respiratory distress syndrome are generally associated with an adverse outcome. Chest CT examinations performed during the convalescent period have demonstrated persistent ground glass attenuation and segmental consolidation. Additional features included pseudocavitation, pneumatocoele formation, lymphadenopathy, and centrilobular nodules. Overall the appearances are suggestive of mild fibrosis.


Asunto(s)
Subtipo H5N1 del Virus de la Influenza A , Gripe Aviar/diagnóstico por imagen , Gripe Humana/diagnóstico por imagen , Animales , Asia Sudoriental/epidemiología , Brotes de Enfermedades , Humanos , Gripe Aviar/epidemiología , Gripe Aviar/patología , Gripe Aviar/terapia , Gripe Aviar/virología , Gripe Humana/epidemiología , Gripe Humana/patología , Gripe Humana/terapia , Gripe Humana/virología , Aves de Corral , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/virología , Insuficiencia Respiratoria/diagnóstico por imagen , Insuficiencia Respiratoria/virología , Tomografía Computarizada por Rayos X
10.
Clin Chest Med ; 27(2): 193-213, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16716813

RESUMEN

Imaging plays an important role in the diagnosis and subsequent management of patients with pleural disease. The presence of a pleural abnormality is usually suggested following a routine chest x-ray, with a number of imaging modalities available for further characterization. This article describes the radiographic and cross-sectional appearances of pleural diseases, which are commonly encountered in every day practice. The conditions covered include benign and malignant pleural thickening, pleural effusions, empyema and pneumothoraces. The relative merits of CT, MRI and PET in the assessment of these conditions and the role of image-guided intervention are discussed.


Asunto(s)
Enfermedades Pleurales/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Biopsia , Humanos , Imagen por Resonancia Magnética , Mesotelioma/diagnóstico por imagen , Mesotelioma/patología , Enfermedades Pleurales/patología , Derrame Pleural/diagnóstico por imagen , Derrame Pleural/patología , Neoplasias Pleurales/diagnóstico por imagen , Neoplasias Pleurales/patología , Neoplasias Pleurales/secundario , Neumotórax/diagnóstico por imagen , Neumotórax/patología , Atelectasia Pulmonar/diagnóstico por imagen , Atelectasia Pulmonar/patología , Intensificación de Imagen Radiográfica , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA