Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
2.
J Exp Orthop ; 11(3): e12048, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38863940

RESUMEN

Purpose: Healing after bone fracture is assessed by clinical examination and frequent radiographs, which expose patients to radiation and lack standardisation. This study aimed to explore electrical impedance patterns during bone healing using electrical impedance spectroscopy in 18 rabbits subjected to tibial fracture stabilised with an external fixator. Methods: Impedance was measured daily across the fracture site at a frequency range of 5 Hz to 1 MHz. Biweekly radiographs were analysed using modified anterior-posterior (AP) radiographic union score of the tibia (RUST). The animals were divided into three groups with different follow-up times: 1, 3 and 6 weeks for micro-computer tomography and mechanical testing. Results: A decreasing trend in impedance was observed over time for all rabbits at lower frequencies. Impedance closest to 5 Hz showed a statistically significant decrease over time, with greatest decrease occurring during the first 7 postoperative days. At 5 Hz, a statistically significant correlation was found between impedance and the modified AP RUST score and between impedance and bone volume fraction. Conclusions: This study showed that the electrical impedance can be measured in vivo at a distance from the fracture site with a consistent change in impedance over time and revealed significant correlation between increasing radiographic union score and decreasing impedance. Level of Evidence: Not applicable.

3.
Trials ; 25(1): 420, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937792

RESUMEN

BACKGROUND: Treatment of displaced distal forearm fractures in children has traditionally been closed reduction and pin fixation, although they might heal and remodel without surgery with no functional impairment. No randomized controlled trials have been published comparing the patient-reported functional outcome following non-surgical or surgical treatment of displaced paediatric distal forearm fractures. METHODS: A multicentre non-inferiority randomized controlled trial. Children aged 4-10 years with a displaced distal forearm fracture will be offered inclusion, if the on-duty orthopaedic surgeon finds indication for surgical intervention. They will be allocated equally to non-surgical treatment (intervention) or surgical treatment of surgeon's choice (comparator). Follow-up will be 4 weeks and 3, 6, and 12 months. The primary outcome is the between-group difference in 12 months QuickDASH score. We will need a sample of 40 patients to show a 15-point difference with 80% power. DISCUSSION: The results of this trial may change our understanding of the healing potential of paediatric distal forearm fractures. If non-inferiority of non-surgical treatment is shown, the results may contribute to a reduction in future surgeries on children, who in turn can be treated without the risks and psychological burdens associated with surgery. TRIAL REGISTRATION: www. CLINICALTRIALS: gov (ID: NCT05736068). Date of registry: 17 February 2023.


Asunto(s)
Anestesia General , Moldes Quirúrgicos , Estudios Multicéntricos como Asunto , Ensayos Clínicos Pragmáticos como Asunto , Fracturas del Radio , Humanos , Niño , Preescolar , Fracturas del Radio/cirugía , Fracturas del Radio/terapia , Resultado del Tratamiento , Fracturas del Cúbito/cirugía , Fracturas del Cúbito/terapia , Estudios de Equivalencia como Asunto , Femenino , Masculino , Factores de Tiempo , Curación de Fractura , Fijación de Fractura/efectos adversos , Fijación de Fractura/métodos , Factores de Edad , Traumatismos del Antebrazo/cirugía , Traumatismos del Antebrazo/terapia , Recuperación de la Función , Fracturas de la Muñeca
4.
Acta Orthop ; 95: 225-232, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38757681

RESUMEN

BACKGROUND AND PURPOSE: Post-discharge inquiries to the hospital are predominantly conducted through phone calls. The rigid timing of these calls is inconvenient for patients and disrupts the workflows of healthcare professionals. The aim of this study was to investigate the effect of a team-based digital communication intervention (eDialogue) facilitated through a messenger-like commercial solution on patient-initiated phone calls to the hospital after discharge. Secondarily, we investigated other patient-initiated contacts, patients' perception of continuity of care, and their perception of feeling safe and satisfied after hospital discharge. METHODS: On the day of discharge, 70 surgically treated orthopedic patients were randomized to the intervention group with access to eDialogue (n = 35) or the control group with standard communication pathways by phone call (n = 35) for the following 8 weeks. Through eDialogue, the intervention group had access to team-based asynchronous digital communication in text and photos with healthcare professionals across disciplines and sectors. Inclusion criteria were discharge to own home and receipt of rehabilitation services from both hospital and primary care after discharge. RESULTS: We found a significant reduction in the mean number of patient-initiated phone calls to the hospital from 2.3 (95% confidence interval [CI] 1.4-4.1) in the control group to 0.5 (CI 0.3-1.0) in the intervention group (P = 0.004). Across groups, patients reported similar perceptions of continuity of care; however, the participants in the intervention group expressed significantly improved perceptions of, and satisfaction with, access to healthcare after discharge. CONCLUSION: Access to eDialogue reduced patient-initiated phone calls to the hospital, enhanced patient satisfaction with healthcare accessibility, and did not compromise patients' perception of continuity of care after discharge compared with standard communication pathways.


Asunto(s)
Continuidad de la Atención al Paciente , Procedimientos Ortopédicos , Alta del Paciente , Satisfacción del Paciente , Humanos , Femenino , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/métodos , Anciano , Teléfono , Adulto , Grupo de Atención al Paciente , Comunicación
5.
Cureus ; 16(4): e58169, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38616978

RESUMEN

Background Rotational deformities in children are currently treated with an osteotomy, acute de-rotation, and surgical fixation. Meanwhile, guided growth is now the gold standard in pediatric coronal deformity correction. This study aimed to evaluate the feasibility of a novel implant intended for rotational guided growth (RotOs Plate) in a large porcine animal model. Methodology A submuscular plate was inserted on the medial and lateral aspect of the distal femoral physis of the left femur in 6 pigs. Each plate was anchored with a screw in the metaphysis and epiphysis respectively. The plates were expected to rotate the femur externally. The right femur acted as a control in a paired design. The animals were housed for 12 weeks after surgery. MRI scanning of both femora was performed before euthanasia after 12 weeks. Rotation was determined as the difference in the femoral version on MRI between the operated and non-operated femur after 12 weeks. Results External rotation in all operated femurs was observed. The mean difference in the femoral version on MRI between operated and non-operated femurs was 12.5° (range 9°-16°). No significant changes in axial growth were detected. Conclusions This study shows encouraging results regarding rotational guided growth, which may replace current invasive surgical treatment options for malrotation in children. However, further studies addressing potential secondary deformities are paramount and should be carried out.

6.
Dan Med J ; 71(3)2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38445315

RESUMEN

INTRODUCTION: Continuous peripheral nerve blocks (cPNBs) have shown favourable post-operative pain control results but may be associated with a risk for long-term neurological complications. This study sought to examine factors associated with persistent post-operative pain and potential neuropathy after orthopaedic lower-limb surgery with the use of post-operative cPNB. METHODS: Patients who underwent lower limb orthopaedic procedures with cPNBs between November 2021 to May 2022 were included. Patient demographics and perioperative data were noted. At discharge, patients completed the PainDetect (PD) questionnaire and were followed up six months after discharge. RESULTS: Seventy-seven patients with a total of 171 catheters completed the follow up. The median time to follow-up was 214 days after catheter removal, and 18 patients (23%) had a PD score ≥ 13. Univariate analysis showed that multiple variables were associated with a PD score ≥ 13 at the six-month follow-up. Multiple logistic regression showed that a high PD score at discharge, high BMI and longer duration of cPNBs were associated with higher risk of having a PD score ≥ 13 at the six-month follow-up. CONCLUSION: Several factors were associated with a higher risk of having possible neuropathy after six months. BMI, duration of catheter and PD score at discharge were correlated with risk of possible neuropathic pain. FUNDING: None. TRIAL REGISTRATION: The study was a quality control project and therefore did not require registration under Danish law.


Asunto(s)
Neuralgia , Procedimientos Ortopédicos , Ortopedia , Humanos , Procedimientos Ortopédicos/efectos adversos , Neuralgia/etiología , Dolor Postoperatorio/etiología , Nervios Periféricos
7.
JMIR Hum Factors ; 11: e53391, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38457798

RESUMEN

BACKGROUND: Orthopedic surgical treatment is a transversal task that requires the active involvement of patients, relatives, and health care professionals (HCPs) across various settings. However, after hospital discharge, communication is challenged and undertaken primarily by phone. New digital communication solutions have the potential to create a space for seamless and patient-centered dialogue across discipline and sector boundaries. When evaluating new communication solutions, knowledge about HCPs' needs and perspectives of use must be explored, as it is they who are responsible for implementing changes in practice. OBJECTIVE: This study aimed to (1) investigate HCPs' perceptions of current communication pathways (phase 1) and (2) explore their experiences of using a simple messenger-like solution (eDialogue) for team-based digital communication across settings (phase 2). METHODS: We used a triangulation of qualitative data collection techniques, including document analysis, observations, focus groups, and individual interviews of HCPs before (n=28) and after (n=12) their use of eDialogue. Data collection and analysis were inspired by the Consolidated Framework for Implementation Research (CFIR) to specifically understand facilitators and barriers to implementation as perceived by HCPs. RESULTS: HCPs perceive current communication pathways as insufficient for both patients and themselves. Phone calls are disruptive, and there is a lack of direct communication modalities when communication crosses sector boundaries. HCPs experienced the use of eDialogue as a quick and easy way for timely interdisciplinary interaction with patients and other HCPs across settings; however, concerns were raised about time consumption. CONCLUSIONS: eDialogue can provide needed support for interdisciplinary and cross-sectoral patient-centered communication. However, future studies of this solution should address its impact and the use of resources.


Asunto(s)
Comunicación , Personal de Salud , Humanos , Investigación Cualitativa , Grupos Focales , Análisis de Documentos
8.
JMIR Hum Factors ; 11: e49696, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38551641

RESUMEN

BACKGROUND: The transition from hospital to home after orthopedic surgery requires smooth communication and coordination between patients and their team of care to avoid fragmented care pathways. Digital communication is increasingly being used to facilitate easy and accessible asynchronous communication between patients and health care professionals across settings. A team-based approach to digital communication may provide optimized quality of care in the postoperative period following orthopedic surgery and hospital discharge. OBJECTIVE: This study was divided into two phases that aimed to (1) explore the perspectives of patients undergoing orthopedic surgery on current communication pathways at a tertiary hospital in Denmark and (2) test and explore patients' experiences and use of team-based digital communication following hospital discharge (eDialogue). METHODS: A triangulation of qualitative data collection techniques was applied: document analysis, participant observations (n=16 hours), semistructured interviews with patients before (n=31) and after (n=24) their access to eDialogue, and exploration of use data. RESULTS: Findings show that patients experience difficult communication pathways after hospital discharge and a lack of information due to inadequate coordination of care. eDialogue was used by 84% (26/31) of the patients, and they suggested that it provided a sense of security, coherence, and proximity in the aftercare rearranging communication pathways for the better. Specific drivers and barriers to use were identified, and these call for further exploration of eDialogue. CONCLUSIONS: In conclusion, patients evaluated eDialogue positively and suggested that it could support them after returning home following orthopedic surgery.


Asunto(s)
Procedimientos Ortopédicos , Alta del Paciente , Humanos , Investigación Cualitativa , Comunicación , Centros de Atención Terciaria
9.
J Pediatr Orthop B ; 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38324644

RESUMEN

Epiphysiodesis is considered the preferred treatment for children predicted to have leg length discrepancies (LLDs) 2-5 cm at maturity. The aim of this study was to systematically review the existing literature on the effectiveness of permanent epiphysiodesis for LLD treatment, and secondarily to address the reported complications of permanent epiphysiodesis techniques. This systematic review was performed according to PRISMA guidelines. We searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with permanent epiphysiodesis. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre/post-operatively, successful/unsuccessful), physeal fusion/arrest, and complications that were graded on severity. Forty-nine studies (3051 patients) were included, 1550 underwent Phemister/modified Phemister epiphysiodesis and 1501 percutaneous epiphysiodesis (PE). Total successful permanent epiphysiodesis surgeries (16 studies) were 73.7% (516/700). Only 13 out of 23 studies had a mean final LLD of less than 1.5 cm. In total, 17.5% (513/2936) of complications were reported. 57 angular deformities were reported (1.9%). Phemister technique had higher percentage of complications (39%) than PE (19.1%) in total, but when failure to achieve adequate reduction in LLD was not included, complication rates for both were close to 14%. However, severe complications were 10.2% for Phemister group and 5.1% for PE. The high complication rates and the relative low success rate call for optimization of the timing and the applied techniques when treating LLD with permanent epiphysiodesis. Phemister technique was found to have higher percentage of severe complications than PE. Registration: PROSPERO (CRD42023435177).

10.
EFORT Open Rev ; 9(2): 119-128, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38308954

RESUMEN

Purpose: The objective of this scoping review was to describe the extent and type of evidence of using guided growth to correct rotational deformities of long bones in children. Methods: This scoping review was conducted in accordance with the JBI methodology for scoping reviews. All published and unpublished studies investigating surgical methods using guided growth to perform gradual rotation of long bones were included. Results: Fourteen studies were included: one review, three clinical studies, and ten preclinical studies. In the three clinical studies, three different surgical methods were used on 21 children. Some degree of rotation was achieved in all but two children. Adverse effects reported included limb length discrepancy (LLD), knee stiffness and rebound of rotation after removal of tethers. Of the ten preclinical studies, two were ex vivo and eight were in vivo. Rotation was achieved in all preclinical studies. Adverse effects reported included implant extrusions, LLD, articular deformities, joint stiffness and rebound of rotation after removal of tethers. Two of the studies reported on histological changes. Conclusions: All studies conclude that guided growth is a potential treatment for rotational deformities of long bones. There is great variation in animal models and surgical methods used and in reported adverse effects. More research is needed to shed light on the best surgical guided growth method, its effectiveness as well as the involved risks and complications. Based on current evidence the procedure is still to be considered experimental. Level of evidence: 4.

11.
Bone Jt Open ; 5(1): 3-8, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38164740

RESUMEN

Aims: The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%. Methods: We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots. Results: We included 2,735 newborns, of whom 754 received a follow-up hip ultrasound within six weeks of age. After exclusion, 1,500 hips were included for analysis. Sex distribution was 372 male and 380 female, and the mean age at examination was 36.6 days (4 to 87). We found a negative linear correlation of PFD to α angles (p < 0.001), FHC (p < 0.001), and FHC during provocation (p < 0.001) with a 1 mm increase in PFD corresponding to a -2.1° (95% confidence interval (CI) -2.3 to -1.9) change in α angle and a -3.4% (95% CI -3.7 to -3.0) change in FHC and a -6.0% (-6.6 to -5.5) change in FHC during provocation. The PFD was significantly higher with increasing Graf types and in displaceable hips (p < 0.001). Conclusion: PFD is strongly correlated to both α angles and hip displaceability, as measured by FHC and FHC during provocation, in ultrasound of newborn hips. The PFD increases as the hips become more dysplastic and/or displaceable.

12.
J Orthop Res ; 42(5): 1074-1085, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38053300

RESUMEN

This study aimed to develop a method using computer vision techniques to accurately detect and delineate the proximal femur in radiographs of Legg-Calvé-Perthes disease (LCPD) patients. Currently, evaluating femoral head deformity, a crucial predictor of LCPD outcomes, relies on unreliable categorical and qualitative classifications. To address this limitation, we employed the pretrained object detection model YOLOv5 to detect the proximal femur on over 2000 radiographs, including images of shoulders and chests, to enhance robustness and generalizability. Subsequently, we utilized the U-Net convolutional neural network architecture for image segmentation of the proximal femur in more than 800 manually annotated images of stage IV LCPD. The results demonstrate outstanding performance, with the object detection model achieving high accuracy (mean average precision of 0.99) and the segmentation model attaining an accuracy score of 91%, dice coefficient of 0.75, and binary IoU score of 0.85 on the held-out test set. The proposed fully automatic proximal femur detection and segmentation system offers a promising approach to accurately detect and delineate the proximal femoral bone contour in radiographic images, which is essential for further image analysis in LCPD patients. Clinical significance: This study highlights the potential of computer vision techniques for enhancing the reliability of Legg-Calvé-Perthes disease staging and outcome prediction.


Asunto(s)
Enfermedad de Legg-Calve-Perthes , Humanos , Enfermedad de Legg-Calve-Perthes/diagnóstico por imagen , Reproducibilidad de los Resultados , Fémur/diagnóstico por imagen , Radiografía , Pronóstico , Cabeza Femoral
13.
Acta Paediatr ; 113(2): 353-361, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38009533

RESUMEN

AIM: We investigated the reliability and validity of the Danish child and parent versions of the Gait Outcomes Assessment List (GOAL) questionnaires for ambulatory children with cerebral palsy (CP). METHODS: Translation and cultural adaptations were performed and content validity evaluated. Participants were enrolled between 2016 and 2018 from Aarhus University Hospital, Denmark. Children and parents completed the GOAL questionnaires twice for test-retest reliability. Discriminative validity was evaluated by comparing the child and parent GOAL scores between children with Gross Motor Function Classification System (GMFCS) levels I and II. The concurrent validity of the GOAL questionnaires were investigated by comparing them with Challenge-20, which assesses motor skills in children with CP. RESULTS: We studied 59 children (57% boys) with CP and GMFCS I-II at a mean age of 10.6 years. Test-retest intra-class correlations were excellent for the children (0.91, 95% confidence interval (CI) 0.83-0.96) and good for the parents (0.83, 95% CI 0.67-0.91). GOAL scores decreased with increasing GMFCS (p < 0.05). Both versions correlated well. The mean children's scores were significantly (6.2/100) higher than the parents' (p < 0.001). The GOAL scores correlated positively with Challenge-20. CONCLUSION: The Danish GOAL child and parent questionnaires demonstrated good reliability and content and discriminative and concurrent validity.


Asunto(s)
Parálisis Cerebral , Niño , Masculino , Humanos , Femenino , Parálisis Cerebral/diagnóstico , Reproducibilidad de los Resultados , Marcha , Encuestas y Cuestionarios , Padres , Evaluación de Resultado en la Atención de Salud , Dinamarca
14.
Acta Orthop ; 94: 594-599, 2023 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-38093629

RESUMEN

BACKGROUND AND PURPOSE: There is inconsistency in the literature regarding the relationship between increased birthweight and risk of developmental dysplasia of the hip (DDH). We aimed to investigate the correlation between birthweight and pubo-femoral distance (PFD), as well as Graf's α angle in newborns undergoing hip ultrasound examination at 6 weeks of age. PATIENTS AND METHODS: Basic newborn characteristics and ultrasound measurements were retrospectively collected during a 1-year study period. We excluded multiple births, newborns born at less than 37 gestational weeks, and incomplete information. Simple and multiple linear regression analyses were performed to evaluate the correlation of birthweight and PFD, and, second, birthweight and α angles including a stratified regression analysis investigating the potential effect modification of sex. RESULTS: 707 newborns (1,414 hips) were included. Mean birthweight was significantly higher for male newborns (P < 0.001). Increased birthweight was positively correlated to PFD values (crude coefficient 0.21, 95% confidence interval [CI] 0.10-0.32) and the correlation was still present after adjusting for sex, family history, and breech presentation (adjusted coefficient 0.18, CI 0.07-0.29). The stratified α angle model for the males was significant for both the crude coefficient (-0.73, CI -1.28 to -0.19) and the adjusted (-0.59, CI -1.15 to -0.03), and also for the females (crude coefficient -1.14, CI -1.98 to -0.31 and adjusted coefficient -1.15, CI -1.99 to -0.31). CONCLUSION: We found that increased birthweight positively correlated to PFD, and negatively correlated to α angle, but this was not of clinical significance.


Asunto(s)
Luxación Congénita de la Cadera , Embarazo , Femenino , Humanos , Recién Nacido , Masculino , Estudios Retrospectivos , Luxación Congénita de la Cadera/diagnóstico por imagen , Luxación Congénita de la Cadera/epidemiología , Peso al Nacer , Fémur/diagnóstico por imagen , Examen Físico , Ultrasonografía
15.
JMIR Mhealth Uhealth ; 11: e44442, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37283228

RESUMEN

BACKGROUND: Smartphones are often equipped with inertial sensors that measure individuals' physical activity (PA). However, their role in remote monitoring of the patients' PAs in telemedicine needs to be adequately explored. OBJECTIVE: This study aimed to explore the correlation between a participant's actual daily step counts and the daily step counts reported by their smartphone. In addition, we inquired about the usability of smartphones for collecting PA data. METHODS: This prospective observational study was conducted among patients undergoing lower limb orthopedic surgery and a group of nonpatients as control. The data from the patients were collected from 2 weeks before surgery until 4 weeks after the surgery, whereas the data collection period for the nonpatients was 2 weeks. The participant's daily step count was recorded by PA trackers worn 24/7. In addition, a smartphone app collected the number of daily steps registered by the participants' smartphones. We compared the cross-correlation between the daily steps time series obtained from the smartphones and PA trackers in different groups of participants. We also used mixed modeling to estimate the total number of steps, using smartphone step counts and the characteristics of the patients as independent variables. The System Usability Scale was used to evaluate the participants' experience with the smartphone app and the PA tracker. RESULTS: Overall, 1067 days of data were collected from 21 patients (n=11, 52% female patients) and 10 nonpatients (n=6, 60% female patients). The median cross-correlation coefficient on the same day was 0.70 (IQR 0.53-0.83). The correlation in the nonpatient group was slightly higher than that in the patient group (median 0.74, IQR 0.60-0.90 and median 0.69, IQR 0.52-0.81, respectively). The likelihood ratio tests on the models fitted by mixed effects methods demonstrated that the smartphone step count was positively correlated with the PA tracker's total number of steps (χ21=34.7, P<.001). In addition, the median usability score for the smartphone app was 78 (IQR 73-88) compared with median 73 (IQR 68-80) for the PA tracker. CONCLUSIONS: Considering the ubiquity, convenience, and practicality of smartphones, the high correlation between the smartphones and the total daily step count time series highlights the potential usefulness of smartphones in detecting changes in the number of steps in remote monitoring of a patient's PA.


Asunto(s)
Aplicaciones Móviles , Teléfono Inteligente , Humanos , Femenino , Masculino , Estudios de Factibilidad , Ejercicio Físico , Recolección de Datos
16.
Children (Basel) ; 10(4)2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37190007

RESUMEN

The osseous acetabular index (OAI) and cartilaginous acetabular index (CAI) is often used in diagnosing acetabular dysplasia (AD) in children. We examined the reliability of OAI and CAI in AD diagnostics and compared OAI measurements obtained from radiographs versus MRI. Four raters performed retrospective repeated measurements of the OAI and CAI on pelvic radiographs and MRI scans of 16 consecutive patients (mean age 5 years (2-8)) examined for borderline AD during a period of 2½ years. In MRI, the image selected for analysis by the raters was also registered. Spearman's correlation, scatter plots, and Bland-Altman (BA) plots were analysed for correlation between OAI on pelvic radiographs (OAIR) and MRI scans (OAIMRI), while intra- and interrater reliability was assessed for OAIR, OAIMRI, CAI, and MRI image selection using intraclass correlation coefficients (ICC). ICC values for inter- and intrarater reliability of OAIR, OAIMRI, and CAI were all above 0.65, with no significant differences observed. ICC values (CI) for individual raters' MRI image selection was 0.99 (0.998-0.999). The mean difference (95% CI) between OAIR and OAIMRI was -0.99 degrees (-1.84; -0.16), while the mean absolute difference (95% CI) between OAIR and OAIMRI was 3.68 degrees (3.17; 4.20). Absolute differences between OAIR and OAIMRI was independent of pelvic positioning or time interval between radiographs and MRI scans. OAI and CAI had high Intrarater reliability but mediocre interrater reliability. There was an absolute difference of 3.7 degrees in OAI between pelvic radiographs and MRI scans.

17.
J Orthop Case Rep ; 13(2): 5-9, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37144065

RESUMEN

Introduction: X-linked hypophosphatemic rachitis (XLHR) is the most common cause of hereditary rickets that can lead to long bone deformities requiring multiple surgical correction procedures. In addition, high rates of fractures are reported in adult XLHR patients. This study aimed to report a case of femoral neck stress fracture in XLHR patient treated with mechanical axis correction. No previous studies demonstrating a combined valgus correction and cephalomedullary nail fixation were identified in the literature. Case Report: A 47-year-old male patient with XLHR attended the outpatient clinic with severe left hip pain. X-rays revealed a left proximal femoral varus deformity and a femoral neck stress fracture. After 1 month without improvement of pain, and no radiographic sign of healing, correction of the proximal femoral varus deformity and fixation of the cervical neck fracture was achieved by a cephalomedullary nail. At 8 months follow-up, hip pain relief was achieved with radiographic healing of the femoral neck stress fracture and the proximal femoral osteotomy. Conclusion: A review of the literature was performed to identify any case report of femoral neck fractures fixation due to coxa vara in an adult. Both coxa vara and XLHR can cause femoral neck stress fracture. This study presented the surgical technique for treating a rare case of femoral neck stress fracture in a XLHR patient with coxa vara. Pain relief and bone healing were achieved by combined deformity correction and fracture fixation with a femoral cephalomedullary nail. The technique for deformity correction and cephalomedullary nail insertion in the patient with coxa vara is shown.

18.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-36904954

RESUMEN

Determining the presence and severity of knee osteoarthritis (OA) is a valuable application of inertial measurement units (IMUs) in the remote monitoring of patients. This study aimed to employ the Fourier representation of IMU signals to differentiate between individuals with and without knee OA. We included 27 patients with unilateral knee osteoarthritis (15 females) and 18 healthy controls (11 females). Gait acceleration signals were recorded during overground walking. We obtained the frequency features of the signals using the Fourier transform. The logistic LASSO regression was employed on the frequency domain features as well as the participant's age, sex, and BMI to distinguish between the acceleration data from individuals with and without knee OA. The model's accuracy was estimated by 10-fold cross-validation. The frequency contents of the signals were different between the two groups. The average accuracy of the classification model using the frequency features was 0.91 ± 0.01. The distribution of the selected features in the final model differed between patients with different severity of knee OA. In this study, we demonstrated that using logistic LASSO regression on the Fourier representation of acceleration signals can accurately determine the presence of knee OA.


Asunto(s)
Osteoartritis de la Rodilla , Femenino , Humanos , Articulación de la Rodilla , Marcha , Caminata , Aceleración , Fenómenos Biomecánicos
19.
Acta Orthop ; 94: 51-59, 2023 02 17.
Artículo en Inglés | MEDLINE | ID: mdl-36807707

RESUMEN

BACKGROUND AND PURPOSE: Intramedullary bone-lengthening nails have become increasingly popular. The 2 most used and successful nails are the FITBONE and the PRECICE nails. Uniform reporting is lacking on complications of intramedullary bone-lengthening nails. The purpose was therefore to assess and categorize the complications of lower limb bone-lengthening nails and investigate risk factors. PATIENTS AND METHODS: We performed a retrospective review of patients operated on with intramedullary lengthening nails at 2 hospitals. We included only lower limb lengthening with FITBONE and PRECICE nails. Recorded patient data was patient demographics, nail information, and any complication. Complications were graded according to severity and origin classification. Complication risk factors were assessed with modified Poisson regression. RESULTS: 314 segments in 257 patients were included. The FITBONE nail was predominantly used (75%), and most of the lengthenings were performed in the femur (80%). 53% of the patients had complications. 269 complications were identified in 175 segments (144 patients). Device-related complications were most frequent (0.3 complications/segment), followed by joint complications (0.2 complications/segment). An increased relative risk was found for complications in the tibia compared with the femur and for age groups above 30 years compared with the 10-19 years group. CONCLUSION: Complications with intramedullary bone lengthening nails were more frequent than has previously been reported, with 53% of patients sustaining a complication. Future studies need to document the complications meticulously so that the true risk can be established.


Asunto(s)
Alargamiento Óseo , Fijación Intramedular de Fracturas , Humanos , Adulto , Fijación Intramedular de Fracturas/efectos adversos , Diferencia de Longitud de las Piernas/cirugía , Estudios de Cohortes , Uñas , Clavos Ortopédicos , Fémur/cirugía , Factores de Riesgo , Estudios Retrospectivos , Resultado del Tratamiento
20.
Children (Basel) ; 9(9)2022 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-36138654

RESUMEN

The pubo-femoral distance (PFD) has been suggested as an ultrasound screening tool for developmental dysplasia of the hip (DDH). The aim of this study was to examine if midwives undergoing minimal training could reliably perform pediatric hip ultrasound and PFD measurements. Eight recruited midwives performed two rounds of independent blinded PFD measurements on 15 static ultrasound images and participated in four supervised live-scanning sessions. The midwives were compared to a group of three experienced musculoskeletal radiologists. Reliability was evaluated using inter-rater correlation coefficients (ICC). Linear regression was used to quantify the learning curve of the midwives as a group. There was near complete intra- and inter-rater agreement (ICC > 0.89) on static ultrasound images across both rounds of rating for midwives and radiologists. The midwives performed a mean of 29 live hip scans (range 24−35). The mean difference between midwives and supervising radiologists was 0.36 mm, 95% CI (0.12−0.61) for the first session, which decreased to 0.20 mm, 95% CI (0.04−0.37) in the fourth session. ICC for PFD measurements increased from 0.59 mm, 95% CI (0.37−0.75) to 0.78 mm, 95% CI (0.66−0.86) with progression in sessions. We conclude that midwives reliably perform PFD measurements of pediatric hips with minimal training.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...