Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 59
2.
Article En | MEDLINE | ID: mdl-37542669

Endoscopic ultrasound (EUS) is an important tool for the evaluation of lymphadenopathy, especially in intra-thoracic or intra-abdominal regions. EUS also provides tissue diagnosis via EUS fine-needle aspiration or biopsy. To select the target for biopsy or aspiration, conventional B-mode images are used for the evaluation, but this approach still lacks diagnostic accuracy. Contrast-enhanced EUS has been used to evaluate the vascularity of lesions. Most malignant lymphadenopathy shows heterogenous enhancement or defect of enhancement, while quantitative studies using time-intensity curves in contrast-enhanced harmonic EUS show a rapid decline in enhancement pattern. These findings are useful as an auxiliary method for tissue diagnosis or in cases in which tissue diagnosis is contraindicated.

3.
Endosc Ultrasound ; 12(1): 96-103, 2023.
Article En | MEDLINE | ID: mdl-36861508

Background and Objectives: EUS-guided biliary drainage (EUS-BD) required a dedicated training. We developed and evaluated a nonfluoroscopic, all-artificial training model known as Thai Association for Gastrointestinal Endoscopy Model 2 (TAGE-2) for the training of EUS-guided hepaticogastrostomy (EUS-HGS) and EUS-guided choledochoduodenostomy (EUS-CDS). We hypothesize that trainers and trainees would appreciate the ease of the nonfluoroscopy model and increase their confidence to start their real procedures in humans. Materials and Methods: We prospectively evaluated the TAGE-2 launched in two international EUS hands-on workshops and have followed trainees for 3 years to see long-term outcomes. After completing the training procedure, the participants answered questionnaires to assess their immediate satisfaction of the models in and also the impact of these models on their clinical practice 3 years after the workshop. Results: A total of 28 participants used the EUS-HGS model and 45 participants used the EUS-CDS model. The EUS-HGS model was rated as excellent by 60% of beginners and 40% by experienced and the EUS-CDS model was rated as excellent by 62.5% of beginners and 57.2% of experienced. The majority of trainees (85.7%) have started the EUS-BD procedure in humans without additional training in other models. Conclusion: Our nonfluoroscopic, all-artificial model for EUS-BD training is convenient to be used with good-to-excellent satisfaction scored by the participants in most aspects. It can help the majority of trainees start their procedures in humans without additional training in other models.

4.
PLoS One ; 18(3): e0282899, 2023.
Article En | MEDLINE | ID: mdl-36928213

INTRODUCTION: To develop a simplified scoring system for clinical prediction of difficulty in CBD stone removal to assist endoscopists working in resource-limited settings in deciding whether to proceed with an intervention or refer patients to a center capable of performing additional procedures and interventions. METHODS: This study included patients with CBD stones who underwent ERCP at Pattani Hospital between August 2017 and December 2021. Retrospective cohort data was collected and patients were categorized into two groups: bile duct stones successfully treated by endoscopic biliary sphincterotomy and extraction compared to the former method combined with EPLBD. We explored potential predictors using multivariable logistic regression. The chosen logistic coefficients were transformed into a scoring system based on risk with internal validation via bootstrapping procedure. RESULTS: Among the 155 patients who had successful endoscopic therapy for bile duct stones, there were 79 (50.97%) cases of endoscopic biliary sphincterotomy, EPLBD and extraction versus 76 (49.03%) cases without EPLBD. The factors used to derive a scoring system included the size of CBD stones >15 mm, the difference between the stone and distal CBD diameter >2mm, distal CBD arm length <36 mm and stone shape. The score-based model's area under ROC was 0.88 (95% CI: 0.83, 0.93). For clinical use, the range of scores from 0 to 16, was divided into two subcategories based on CBD stone removal difficulty requiring EPLBD to derive the PPV. For scores <5 and ≥ 5, the PPV was 23.40 (p <0.001) and 93.44 (p <0.001) respectively. The Bootstrap sampling method indicated a prediction ability of 0.88 (AuROC, 95% CI: 0.83, 0.94). CONCLUSION: This scoring system has acceptable prediction performance in assisting endoscopists in their choice of stone removal procedure.


Cholangiopancreatography, Endoscopic Retrograde , Choledocholithiasis , Humans , Cholangiopancreatography, Endoscopic Retrograde/methods , Retrospective Studies , Dilatation/methods , Clinical Decision Rules , Treatment Outcome
5.
JGH Open ; 7(1): 16-23, 2023 Jan.
Article En | MEDLINE | ID: mdl-36660050

Background and Aim: For difficult common bile duct (CBD) stones, endoscopic sphincterotomy accompanied by endoscopic papillary large balloon dilatation (EPLBD) may be the preferred initial procedure according to the selection criteria. The purpose of this study was to determine the association between CBD stone-related parameters and their potential prognostic values for technically difficult CBD stone extraction requiring EPLBD. Methods: We retrospectively analyzed the data of 80 patients who underwent endoscopic retrograde cholangiopancreatography (ERCP), endoscopic biliary sphincterotomy, or the aforementioned procedures combined with EPLBD, resulting in successful CBD stone extraction in the first session from January 2018 and December 2021. The association between CBD stone-related parameters and stone extraction requiring EPLBD was analyzed by multivariable risk regression analysis. Results: In multivariable analysis, the independent predictors of CBD stone extraction that required EPLBD were CBD stones larger than distal CBD diameter by >2 mm (risk ratio [RR] 2.34, 95% CI 1.30-4.19) and the presence of shaped stones (round shape RR 1.69 [95% CI 1.05-2.73]; square shape RR 2.34 [95% CI 1.24, 4.44] vs oval shape). Conclusion: Endoscopic CBD stone removal is technically difficult in patients with stones larger than 2 mm in diameter in comparison to the distal CBD diameter or round or square-shaped stones.

6.
Endosc Ultrasound ; 11(3): 201-207, 2022.
Article En | MEDLINE | ID: mdl-35708369

Bckground and Objectives: EUS-guided cystogastrostomy is a well-established advanced endoscopic technique with a steep-learning curve which necessitates an ex-vivo simulator that would allow for adequate training. The aim of this study is to evaluate the feasibility of the model in allowing training for EUS-guided cystogastrostomy using lumen-apposing metal stent (LAMS). Subjects and Methods: The model was created by ROEYA Training Center, Egypt, using native porcine tissue to create fluid collections simulating both cystic and solid lesions. It was designed and tested in advance while the hydrogel was added on-site. The simulator was evaluated prospectively in five training sessions involving 17 international experts. The task was to successfully deploy the LAMS to drain the created cyst. After using the simulator, the experts were asked to fill a questionnaire to assess their experience. The primary endpoint was overall satisfaction with the model as a training tool. Results: All of the experts were satisfied with the model as a tool to train endoscopists for the technique. 76.5% (n = 11) of the experts thought the model to be moderately realistic. Proper visualization was reported by 94.1% of the experts. All experts believed the lesions to be either slightly like or very similar to real lesions. The model was graded "easy" in difficulty by 11 of the experts. Conclusions: In all parameters assessed, the experts thought the model to be a useful tool for future training. This preliminary study suggests that the aforementioned simulator can be used to train endoscopists on using LAMS in a risk-free environment.

7.
Clin Endosc ; 55(2): 215-225, 2022 Mar.
Article En | MEDLINE | ID: mdl-34583452

BACKGROUND/AIMS: The Thai Association for Gastrointestinal Endoscopy published recommendations on safe endoscopy during the coronavirus disease 2019 (COVID-19) pandemic. This study aimed to assess the practicality and applicability of the recommendations and the perceptions of endoscopy personnel on them. METHODS: A validated questionnaire was sent to 1290 endoscopy personnel globally. Of these, the data of all 330 responders (25.6%) from 15 countries, related to the current recommendations on proper personal protective equipment (PPE), case selection, scope cleaning, and safety perception, were analyzed. Ordinal logistic regression was used to determine the relationships between the variables. RESULTS: Despite an overwhelming agreement with the recommendations on PPE (94.5%) and case selection (95.5%), their practicality and applicability on PPE recommendations and case selection were significantly lower (p=0.001, p=0.047, p<0.001, and p=0.032, respectively). Factors that were associated with lower sense of safety in endoscopy units were younger age (p=0.004), less working experience (p=0.008), in-training status (p=0.04), and higher national prevalence of COVID-19 (p=0.003). High prevalent countries also had more difficulty implementing the guidelines (p<0.001) and they considered the PPE recommendations less practical and showed lower agreement with them (p<0.001 and p=0.008, respectively). A higher number of in-hospital COVID-19 patients was associated with less agreement with PPE recommendations (p=0.039). CONCLUSION: Using appropriate PPE and case selection in endoscopic practice during a pandemic remains a challenge. Resource availability and local prevalence are critical factors influencing the adoption of the current guidelines.

8.
HPB (Oxford) ; 24(1): 17-29, 2022 01.
Article En | MEDLINE | ID: mdl-34172378

BACKGROUND: Indeterminate strictures pose a therapeutic dilemma. In recent years, cholangioscopy has evolved and the availability of cholangioscopy has increased. However, the position of cholangioscopy in the diagnostic algorithm to diagnose malignancy have not been well established. We aim to develop a consensus statement regarding the clinical role of cholangioscopy in the diagnosis of indeterminate biliary strictures. METHODS: The international experts reviewed the evidence and modified the statements using a three-step modified Delphi method. Each statement achieves consensus when it has at least 80% agreement. RESULTS: Nine final statements were formulated. An indeterminate biliary stricture is defined as that of uncertain etiology under imaging or tissue diagnosis. When available, cholangioscopic assessment and guided biopsy during the first round of ERCP may reduce the need to perform multiple procedures. Cholangioscopy are helpful in diagnosing malignant biliary strictures by both direct visualization and targeted biopsy. The absence of disease progression for at least 6 months is supportive of non-malignant etiology. Direct per-oral cholangioscopy provides the largest accessory channel, better image definition, with image enhancement but is technically demanding. Image enhancement during cholangioscopy may increase the diagnostic sensitivity of visual impression of malignant biliary strictures. Cholangioscopic imaging characteristics including tumor vessels, papillary projection, nodular or polypoid mass, and infiltrative lesions are highly suggestive for neoplastic/malignant biliary disease. The risk of cholangioscopy related cholangitis is higher than in standard ERCP, necessitating prophylactic antibiotics and ensuring adequate biliary drainage. Per-oral cholangioscopy may not be the modality of choice in the evaluation of distal biliary strictures due to inherent technical difficulties. CONCLUSION: Evidence supports that cholangioscopy has an adjunct role to abdominal imaging and ERCP tissue acquisition in order to evaluate and diagnose indeterminate biliary strictures.


Biliary Tract Surgical Procedures , Cholestasis , Biliary Tract Surgical Procedures/adverse effects , Biopsy/adverse effects , Biopsy/methods , Cholestasis/diagnostic imaging , Cholestasis/etiology , Consensus , Constriction, Pathologic/diagnosis , Constriction, Pathologic/etiology , Humans
11.
J Gastroenterol Hepatol ; 36(12): 3395-3401, 2021 Dec.
Article En | MEDLINE | ID: mdl-34370869

BACKGROUND AND AIM: Our aim was to evaluate the efficacy and safety of a lumen-apposing metal stent with an electrocautery-enhanced delivery system (EDS-LAMS) for endoscopic ultrasound (EUS)-guided drainage of pancreatic fluid collections (PFCs) in regular clinical practice. METHODS: A retrospective and subsequent prospective analysis was undertaken of all patients who underwent EUS-guided drainage of their PFCs using the EDS-LAMS at 17 tertiary therapeutic endoscopy centers. RESULTS: Two hundred eight cases of EDS-LAMS deployment were attempted in 202 patients (mean age 52.9 years) at time of evaluation. Ninety-seven patients had pancreatic pseudocysts (PPs), 75 walled-off pancreatic necrosis (WOPN), 10 acute peripancreatic fluid collections (APFCs), 6 acute necrotic collections (ANCs), and 14 postoperative collections (POCs). Procedural technical success was achieved in 202/208 cases (97.1%). Maldeployment occurred in 7/208 cases (3.4%). Clinical success was achieved in 142/160 (88.8%) patients (PP 90%, WOPN 85.2%, APFC 100%, ANC 75%, POC 100%). Delayed adverse events included stent migration in 15/202 (7.4%), stent occlusion and infection in 16/202 (7.9%), major bleeding in 4/202 (2%), and buried EDS-LAMS in 2/202 (1%). PFC recurrence occurred in 13/142 (9.2%) patients; 9/202 (4.5%) required surgical or radiological intervention for PFC management after EDS-LAMS insertion. CONCLUSIONS: This large international multicenter study evaluating the EDS-LAMS for drainage of PFCs in routine clinical practice suggests that the EDS-LAMS are safe and effective for drainage of all types of PFCs; however, further endoscopic therapy is often required for WOPN. Major bleeding was a rare complication in our cohort.


Drainage , Pancreatic Diseases , Drainage/instrumentation , Electrocoagulation , Humans , Middle Aged , Pancreatic Diseases/surgery , Retrospective Studies , Stents
12.
VideoGIE ; 6(8): 365-367, 2021 Aug.
Article En | MEDLINE | ID: mdl-34401633

Video 1Magnetic compression anastomosis via EUS-guided hepaticogastrostomy for recanalization of complete common hepatic bile duct transection.

13.
Clin Endosc ; 54(3): 301-308, 2021 May.
Article En | MEDLINE | ID: mdl-34082486

Endoscopic retrograde cholangiopancreatography (ERCP) is the primary treatment modality for bile duct obstruction. When ERCP is unsuccessful, percutaneous transhepatic biliary drainage can be an alternative method. Endoscopic ultrasound-guided biliary drainage (EUS-BD) has emerged as a treatment option for biliary obstruction, especially after ERCP failure. EUS-BD offers transluminal intrahepatic and extrahepatic drainage through a transgastric and transduodenal approach. EUS-guided hepaticogastrostomy (EUS-HGS) is an excellent choice for patients with hilar strictures or those with a surgically altered anatomy. The optimal steps in EUS-HGS are case selection, bile duct visualization, puncture-site selection, wire insertion and manipulation, tract dilation, and stent placement. Caution should be taken at each step to prevent complications. Dedicated devices for EUS-HGS have been developed to improve the technical success rate and reduce complications. This technical review focuses on the essential practical points at each step of EUS-HGS.

14.
J Gastroenterol Hepatol ; 36(8): 2198-2209, 2021 Aug.
Article En | MEDLINE | ID: mdl-33609333

BACKGROUND AND AIM: To determine the application range of diagnostic kits utilizing anti-Helicobacter pylori antibody, we tested a newly developed latex aggregation turbidity assay (latex) and a conventional enzyme-linked immunosorbent assay (E-plate), both containing Japanese H. pylori protein lysates as antigens, using sera from seven Asian countries. METHODS: Serum samples (1797) were obtained, and standard H. pylori infection status and atrophy status were determined by culture and histology (immunohistochemistry) using gastric biopsy samples from the same individuals. The two tests (enzyme-linked immunosorbent assay and latex) were applied, and receiver operating characteristics analysis was performed. RESULTS: Area under the curve (AUC) from the receiver operating characteristic of E-plate and latex curves were almost the same and the highest in Vietnam. The latex AUC was slightly lower than the E-plate AUC in other countries, and the difference became statistically significant in Myanmar and then Bangladesh as the lowest. To consider past infection cases, atrophy was additionally evaluated. Most of the AUCs decreased using this atrophy-evaluated status; however, the difference between the two kits was not significant in each country, but the latex AUC was better using all samples. Practical cut-off values were 3.0 U/mL in the E-test and 3.5 U/mL in the latex test, to avoid missing gastric cancer patients to the greatest extent possible. CONCLUSIONS: The kits were applicable in all countries, but new kits using regional H. pylori strains are recommended for Myanmar and Bangladesh. Use of a cut-off value lower than the best cut-off value is essential for screening gastric cancer patients.


Helicobacter Infections , Helicobacter pylori , Stomach Neoplasms , Adult , Aged , Antibodies, Bacterial/blood , Antibodies, Bacterial/immunology , Asia , Atrophy , Biopsy , Early Detection of Cancer , Enzyme-Linked Immunosorbent Assay/methods , Female , Gastric Mucosa/microbiology , Gastric Mucosa/pathology , Helicobacter Infections/blood , Helicobacter Infections/diagnosis , Helicobacter Infections/etiology , Helicobacter pylori/immunology , Helicobacter pylori/isolation & purification , Humans , Latex Fixation Tests/methods , Lymphoma, B-Cell, Marginal Zone/blood , Lymphoma, B-Cell, Marginal Zone/diagnosis , Male , Middle Aged , Sensitivity and Specificity , Stomach Neoplasms/blood , Stomach Neoplasms/diagnosis , Stomach Neoplasms/etiology
15.
Int J Surg Case Rep ; 79: 34-36, 2021 Feb.
Article En | MEDLINE | ID: mdl-33422850

INTRODUCTION AND IMPORTANCE: An adrenal metastasis is uncommon in esophageal cancer. Its diagnosis could be challenging if a percutaneous approach was inaccessible. Moreover, endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), a useful adrenal sampling technique, is complicated by the luminal obstruction. CASE PRESENTATION: A patient with esophageal cancer accompanying by adrenal mass and established gastrostomy was described. The EUS-FNA of the adrenal lesion was successfully performed via the dilated gastrostomy tract. Adequate tissue for pathological examination was achieved, and the result indicated metastatic squamous cell carcinoma. Chemotherapy was started accordingly. CLINICAL DISCUSSION: This report described an uncommon event of adrenal metastasis of esophageal primary. Even though it is possible to perform EUS via the gastrostomy tract, performing EUS from an unusual direction might add some difficulty to an endoscopist, considering that EUS involves image pattern recognition in identifying structures. Thus, this technique should be operated by experienced EUS endoscopists. CONCLUSION: Gastrostomy can provide an enteral route for nutrition support in esophageal cancer patients. In addition, it could be an alternative EUS intervention portal when an esophageal stent is not accessible.

16.
Endoscopy ; 53(1): 55-62, 2021 01.
Article En | MEDLINE | ID: mdl-32515005

BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) may not provide complete biliary drainage in patients with Bismuth III/IV malignant hilar biliary obstruction (MHBO). Complete biliary drainage is accomplished by adding percutaneous transhepatic biliary drainage (PTBD). We prospectively compared recurrent biliary obstruction (RBO) rates between combined ERCP and endoscopic ultrasound-guided biliary drainage (EUS-BD) vs. bilateral PTBD. METHODS: Patients with MHBO undergoing endoscopic procedures (group A) were compared with those undergoing bilateral PTBD (group B). The primary outcome was the 3-month RBO rate. RESULTS: 36 patients were recruited into groups A (n = 19) and B (n = 17). Rates of technical and clinical success, and complications of group A vs. B were 84.2 % (16/19) vs. 100 % (17/17; P = 0.23), 78.9 % (15/19) vs. 76.5 % (13/17; P > 0.99), and 26.3 % (5/19) vs. 35.3 % (6/17; P = 0.56), respectively. Within 3 and 6 months, RBO rates of group A vs. group B were 26.7 % (4/15) vs. 88.2 % (15/17; P  = 0.001) and 22.2 % (2/9) vs. 100 % (9/9; P = 0.002), respectively. At 3 months, median number of biliary reinterventions in group A was significantly lower than in group B (0 [interquartile range] 0-1 vs. 1 [1-2.5]), respectively (P < 0.001). Median time to development of RBO was longer in group A than in group B (92 [56-217] vs. 40 [13.5-57.8] days, respectively; P  =  0.06). CONCLUSIONS: Combined ERCP and EUS procedures provided significantly lower RBO rates at 3 and 6 months vs. bilateral PTBD, with similar complication rates and no significant mortality difference.


Cholangiopancreatography, Endoscopic Retrograde , Cholestasis , Cholangiopancreatography, Endoscopic Retrograde/adverse effects , Cholestasis/etiology , Cholestasis/surgery , Drainage , Endosonography , Humans , Ultrasonography, Interventional
17.
J Clin Med ; 9(12)2020 Dec 17.
Article En | MEDLINE | ID: mdl-33348675

Endoscopic drainage and necrosectomy are now accepted treatment approaches for patients with symptomatic walled-off pancreatic necrosis (WON). The current recommendations advocate step-up approaches for the treatment of symptomatic WON. Previous recommendations stipulated that endoscopic intervention should be delayed until more than four weeks after the onset. Recent data on early drainage have been increasing and this option might be considered in well-encapsulated cases, but the percutaneous route is preferred if the drainage is performed within two weeks after onset or in nonencapsulated cases. Recently, additional drainage methods, such as the multiple gateway technique and multiple stent placement, have been developed to open up multiple dead spaces in the WON cavity. Endoscopic necrosectomy could be performed via the transluminal route or percutaneous route after failed initial and additional drainage procedures. The use of novel lumen-apposing stents is a promising treatment option that could reduce the number of steps, the procedure time, and the overall number of necrosectomies.

19.
Int J Infect Dis ; 97: 102-107, 2020 Aug.
Article En | MEDLINE | ID: mdl-32474200

OBJECTIVES: Bhutan suffers from a high prevalence of Helicobacter pylori (H. pylori) infection and gastric cancer-related mortality. In preparation for a countrywide H. pylori eradication program, the antibiotic resistance patterns of H. pylori infection were surveyed in different geographical regions. METHODS: Dyspeptic patients in 6 districts including Thimphu, Punakha, Wangdue, Trongsa, Bumthang, and Haa underwent upper gastrointestinal endoscopy during GASTROCAMP and were enrolled between December 2010 and April 2015. Gastric biopsies were obtained for rapid urease test, histopathology, and H. pylori culture. Antimicrobial susceptibility testing was later performed if the culture was positive. RESULTS: A total of 1178 patients were surveyed. The overall H. pylori infection in Bhutan was 66.2%. Punakha had the highest prevalence of H. pylori infection (85.6%). Thimphu and Punakha (city areas) had higher prevalence of H. pylori infection than rural districts (73.5% vs 63.3%, OR=1.61, 95% CI 1.22-2.13, p=0.0008). There were 357 patients (30.3%) with positive H. pylori culture completed antimicrobial susceptibility testing. The mean age was 40.5 years with female predominance (57.1%). No amoxicillin resistant strains were found. Metronidazole resistance was 81% followed by levofloxacin resistance (8.1%). Clarithromycin (2%) and tetracycline (0.6%) resistance was rare except in Thimphu, the capital city (10%) vs 0% in rural areas, p<0.001. The metronidazole resistance rate remained stable at approximately 80% during the past 5 years of study. Levofloxacin-resistant strains gradually rose from 5.3% in 2010 to 9.9% in 2015. CONCLUSIONS: Bhutan had a high prevalence of H. pylori infection. Metronidazole resistance was extremely high, whereas clarithromycin resistance was quite low in this specific area. Antibiotic resistance pattern could be good evidence for guiding a proper treatment regimen for H. pylori infection in Bhutan.


Drug Resistance, Bacterial , Helicobacter Infections/epidemiology , Helicobacter pylori/drug effects , Adult , Amoxicillin/pharmacology , Anti-Bacterial Agents/pharmacology , Bhutan/epidemiology , Clarithromycin/pharmacology , Female , Helicobacter Infections/microbiology , Helicobacter pylori/isolation & purification , Humans , Levofloxacin/pharmacology , Male , Metronidazole/pharmacology , Middle Aged , Prevalence , Tetracycline/pharmacology
20.
Asian Pac J Cancer Prev ; 21(5): 1409-1413, 2020 May 01.
Article En | MEDLINE | ID: mdl-32458649

BACKGROUND: Gastric cancer, which is the leading cause of cancer mortality in Cambodia, can be prevented by Helicobacter pylori (H. pylori) eradication. There is limited data about H. pylori strains in Cambodia. This study aimed to evaluate H. pylori prevalence and antibiotic resistance in Koh Kong, Cambodia. METHODS: 118 Cambodian dyspeptic patients were scheduled to enter this study and 58 were enrolled between July and September 2019. All patients underwent upper GI endoscopy. 3 gastric biopsies were obtained for rapid urease test, H. pylori culture with E-test and GenoType® HelicoDr (Hain Lifescience factory, Germany). 3-mL blood sample was collected for CYP2C19 genotyping. RESULTS: 58 subjects were enrolled (40 females, 18 males, mean age 43.8 years). Overall H. pylori prevalence was 31.0%. Antibiotic resistance rates were 78.6% for metronidazole, 50.0% for fluoroquinolones, and 27.8% for clarithromycin. There was no amoxicillin and tetracycline resistance. More than half of H. pylori strains (57.1%) were multidrug-resistant. Most (35.7%) were resistant to metronidazole and quinolone. Poor, intermediate and rapid metabolizers were 5.5%, 38.9% and 55.6%, respectively. CONCLUSIONS: H. pylori infection remains common infection in Cambodia. High prevalence of clarithromycin, metronidazole, levofloxacin and multidrug-resistant H. pylori is still major problems in Cambodia. Treatment regimens without clarithromycin and quinolone such as 14-day bismuth-based quadruple therapy might be an appropriate choice for H. pylori eradication in this particular area.


Anti-Bacterial Agents/pharmacology , Drug Resistance, Microbial , Helicobacter Infections/epidemiology , Helicobacter pylori/isolation & purification , Adolescent , Adult , Cambodia/epidemiology , Female , Follow-Up Studies , Helicobacter Infections/drug therapy , Helicobacter Infections/virology , Helicobacter pylori/drug effects , Humans , Middle Aged , Prevalence , Prognosis , Young Adult
...