Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
PLoS Med ; 18(12): e1003872, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34928960

RESUMEN

BACKGROUND: The United States (US) Expanded Access Program (EAP) to coronavirus disease 2019 (COVID-19) convalescent plasma was initiated in response to the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19. While randomized clinical trials were in various stages of development and enrollment, there was an urgent need for widespread access to potential therapeutic agents. The objective of this study is to report on the demographic, geographical, and chronological characteristics of patients in the EAP, and key safety metrics following transfusion of COVID-19 convalescent plasma. METHODS AND FINDINGS: Mayo Clinic served as the central institutional review board for all participating facilities, and any US physician could participate as a local physician-principal investigator. Eligible patients were hospitalized, were aged 18 years or older, and had-or were at risk of progression to-severe or life-threatening COVID-19; eligible patients were enrolled through the EAP central website. Blood collection facilities rapidly implemented programs to collect convalescent plasma for hospitalized patients with COVID-19. Demographic and clinical characteristics of all enrolled patients in the EAP were summarized. Temporal patterns in access to COVID-19 convalescent plasma were investigated by comparing daily and weekly changes in EAP enrollment in response to changes in infection rate at the state level. Geographical analyses on access to convalescent plasma included assessing EAP enrollment in all national hospital referral regions, as well as assessing enrollment in metropolitan areas and less populated areas that did not have access to COVID-19 clinical trials. From April 3 to August 23, 2020, 105,717 hospitalized patients with severe or life-threatening COVID-19 were enrolled in the EAP. The majority of patients were 60 years of age or older (57.8%), were male (58.4%), and had overweight or obesity (83.8%). There was substantial inclusion of minorities and underserved populations: 46.4% of patients were of a race other than white, and 37.2% of patients were of Hispanic ethnicity. Chronologically and geographically, increases in the number of both enrollments and transfusions in the EAP closely followed confirmed infections across all 50 states. Nearly all national hospital referral regions enrolled and transfused patients in the EAP, including both in metropolitan and in less populated areas. The incidence of serious adverse events was objectively low (<1%), and the overall crude 30-day mortality rate was 25.2% (95% CI, 25.0% to 25.5%). This registry study was limited by the observational and pragmatic study design that did not include a control or comparator group; thus, the data should not be used to infer definitive treatment effects. CONCLUSIONS: These results suggest that the EAP provided widespread access to COVID-19 convalescent plasma in all 50 states, including for underserved racial and ethnic minority populations. The study design of the EAP may serve as a model for future efforts when broad access to a treatment is needed in response to an emerging infectious disease. TRIAL REGISTRATION: ClinicalTrials.gov NCT#: NCT04338360.


Asunto(s)
COVID-19/terapia , Ensayos de Uso Compasivo/métodos , Necesidades y Demandas de Servicios de Salud/estadística & datos numéricos , Sistemas de Distribución en Hospital/organización & administración , Sistema de Registros , Reacción a la Transfusión/complicaciones , Reacción a la Transfusión/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/epidemiología , Minorías Étnicas y Raciales , Femenino , Humanos , Inmunización Pasiva/efectos adversos , Inmunización Pasiva/métodos , Pacientes Internos , Masculino , Área sin Atención Médica , Persona de Mediana Edad , Pandemias , Seguridad del Paciente , SARS-CoV-2 , Resultado del Tratamiento , Estados Unidos , Sueroterapia para COVID-19
2.
Nat Commun ; 12(1): 4864, 2021 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-34381030

RESUMEN

Successful therapeutics and vaccines for coronavirus disease 2019 (COVID-19) have harnessed the immune response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Evidence that SARS-CoV-2 exists as locally evolving variants suggests that immunological differences may impact the effectiveness of antibody-based treatments such as convalescent plasma and vaccines. Considering that near-sourced convalescent plasma likely reflects the antigenic composition of local viral strains, we hypothesize that convalescent plasma has a higher efficacy, as defined by death within 30 days of transfusion, when the convalescent plasma donor and treated patient were in close geographic proximity. Results of a series of modeling techniques applied to approximately 28,000 patients from the Expanded Access to Convalescent Plasma program (ClinicalTrials.gov number: NCT04338360) support this hypothesis. This work has implications for the interpretation of clinical studies, the ability to develop effective COVID-19 treatments, and, potentially, for the effectiveness of COVID-19 vaccines as additional locally-evolving variants continue to emerge.


Asunto(s)
COVID-19/terapia , Plasma/inmunología , Adolescente , Adulto , Anciano , Anticuerpos Antivirales/inmunología , Especificidad de Anticuerpos , Variación Antigénica , Donantes de Sangre , COVID-19/mortalidad , Femenino , Humanos , Inmunización Pasiva/mortalidad , Masculino , Persona de Mediana Edad , SARS-CoV-2/genética , SARS-CoV-2/inmunología , Resultado del Tratamiento , Estados Unidos/epidemiología , Adulto Joven , Sueroterapia para COVID-19
3.
medRxiv ; 2021 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-33851175

RESUMEN

BACKGROUND: The United States (US) Expanded Access Program (EAP) to COVID-19 convalescent plasma was initiated in response to the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease-2019 (COVID-19). While randomized clinical trials were in various stages of development and enrollment, there was an urgent need for widespread access to potential therapeutic agents particularly for vulnerable racial and ethnic minority populations who were disproportionately affected by the pandemic. The objective of this study is to report on the demographic, geographic, and chronological access to COVID-19 convalescent plasma in the US via the EAP. METHODS AND FINDINGS: Mayo Clinic served as the central IRB for all participating facilities and any US physician could participate as local physician-principal investigator. Registration occurred through the EAP central website. Blood banks rapidly developed logistics to provide convalescent plasma to hospitalized patients with COVID-19. Demographic and clinical characteristics of all enrolled patients in the EAP were summarized. Temporal trends in access to COVID-19 convalescent plasma were investigated by comparing daily and weekly changes in EAP enrollment in response to changes in infection rate on a state level. Geographical analyses on access to convalescent plasma included assessing EAP enrollment in all national hospital referral regions as well as assessing enrollment in metropolitan and less populated areas which did not have access to COVID-19 clinical trials.From April 3 to August 23, 2020, 105,717 hospitalized patients with severe or life-threatening COVID-19 were enrolled in the EAP. A majority of patients were older than 60 years of age (57.8%), male (58.4%), and overweight or obese (83.8%). There was substantial inclusion of minorities and underserved populations, including 46.4% of patients with a race other than White, and 37.2% of patients were of Hispanic ethnicity. Severe or life-threatening COVID-19 was present in 61.8% of patients and 18.9% of patients were mechanically ventilated at time of convalescent plasma infusion. Chronologically and geographically, increases in enrollment in the EAP closely followed confirmed infections across all 50 states. Nearly all national hospital referral regions enrolled patients in the EAP, including both in metropolitan and less populated areas. CONCLUSIONS: The EAP successfully provided widespread access to COVID-19 convalescent plasma in all 50 states, including for underserved racial and ethnic minority populations. The efficient study design of the EAP may serve as an example framework for future efforts when broad access to a treatment is needed in response to a dynamic disease affecting demographic groups and areas historically underrepresented in clinical studies.

4.
N Engl J Med ; 384(11): 1015-1027, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33523609

RESUMEN

BACKGROUND: Convalescent plasma has been widely used to treat coronavirus disease 2019 (Covid-19) under the presumption that such plasma contains potentially therapeutic antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that can be passively transferred to the plasma recipient. Whether convalescent plasma with high antibody levels rather than low antibody levels is associated with a lower risk of death is unknown. METHODS: In a retrospective study based on a U.S. national registry, we determined the anti-SARS-CoV-2 IgG antibody levels in convalescent plasma used to treat hospitalized adults with Covid-19. The primary outcome was death within 30 days after plasma transfusion. Patients who were enrolled through July 4, 2020, and for whom data on anti-SARS-CoV-2 antibody levels in plasma transfusions and on 30-day mortality were available were included in the analysis. RESULTS: Of the 3082 patients included in this analysis, death within 30 days after plasma transfusion occurred in 115 of 515 patients (22.3%) in the high-titer group, 549 of 2006 patients (27.4%) in the medium-titer group, and 166 of 561 patients (29.6%) in the low-titer group. The association of anti-SARS-CoV-2 antibody levels with the risk of death from Covid-19 was moderated by mechanical ventilation status. A lower risk of death within 30 days in the high-titer group than in the low-titer group was observed among patients who had not received mechanical ventilation before transfusion (relative risk, 0.66; 95% confidence interval [CI], 0.48 to 0.91), and no effect on the risk of death was observed among patients who had received mechanical ventilation (relative risk, 1.02; 95% CI, 0.78 to 1.32). CONCLUSIONS: Among patients hospitalized with Covid-19 who were not receiving mechanical ventilation, transfusion of plasma with higher anti-SARS-CoV-2 IgG antibody levels was associated with a lower risk of death than transfusion of plasma with lower antibody levels. (Funded by the Department of Health and Human Services and others; ClinicalTrials.gov number, NCT04338360.).


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/terapia , SARS-CoV-2/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/inmunología , COVID-19/mortalidad , Femenino , Hospitalización , Humanos , Inmunización Pasiva , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Sistema de Registros , Respiración Artificial , Estudios Retrospectivos , Factores de Riesgo , Tiempo de Tratamiento , Estados Unidos/epidemiología , Adulto Joven , Sueroterapia para COVID-19
5.
medRxiv ; 2020 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-32817978

RESUMEN

IMPORTANCE: Passive antibody transfer is a longstanding treatment strategy for infectious diseases that involve the respiratory system. In this context, human convalescent plasma has been used to treat coronavirus disease 2019 (COVID-19), but the efficacy remains uncertain. OBJECTIVE: To explore potential signals of efficacy of COVID-19 convalescent plasma. DESIGN: Open-label, Expanded Access Program (EAP) for the treatment of COVID-19 patients with human convalescent plasma. SETTING: Multicenter, including 2,807 acute care facilities in the US and territories. PARTICIPANTS: Adult participants enrolled and transfused under the purview of the US Convalescent Plasma EAP program between April 4 and July 4, 2020 who were hospitalized with (or at risk of) severe or life threatening acute COVID-19 respiratory syndrome. INTERVENTION: Transfusion of at least one unit of human COVID-19 convalescent plasma using standard transfusion guidelines at any time during hospitalization. Convalescent plasma was donated by recently-recovered COVID-19 survivors, and the antibody levels in the units collected were unknown at the time of transfusion. Main Outcomes and Measures: Seven and thirty-day mortality. RESULTS: The 35,322 transfused patients had heterogeneous demographic and clinical characteristics. This cohort included a high proportion of critically-ill patients, with 52.3% in the intensive care unit (ICU) and 27.5% receiving mechanical ventilation at the time of plasma transfusion. The seven-day mortality rate was 8.7% [95% CI 8.3%-9.2%] in patients transfused within 3 days of COVID-19 diagnosis but 11.9% [11.4%-12.2%] in patients transfused 4 or more days after diagnosis (p<0.001). Similar findings were observed in 30-day mortality (21.6% vs. 26.7%, p<0.0001). Importantly, a gradient of mortality was seen in relation to IgG antibody levels in the transfused plasma. For patients who received high IgG plasma (>18.45 S/Co), seven-day mortality was 8.9% (6.8%, 11.7%); for recipients of medium IgG plasma (4.62 to 18.45 S/Co) mortality was 11.6% (10.3%, 13.1%); and for recipients of low IgG plasma (<4.62 S/Co) mortality was 13.7% (11.1%, 16.8%) (p=0.048). This unadjusted dose-response relationship with IgG was also observed in thirty-day mortality (p=0.021). The pooled relative risk of mortality among patients transfused with high antibody level plasma units was 0.65 [0.47-0.92] for 7 days and 0.77 [0.63-0.94] for 30 days compared to low antibody level plasma units. CONCLUSIONS AND RELEVANCE: The relationships between reduced mortality and both earlier time to transfusion and higher antibody levels provide signatures of efficacy for convalescent plasma in the treatment of hospitalized COVID-19 patients. This information may be informative for the treatment of COVID-19 and design of randomized clinical trials involving convalescent plasma. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04338360.

6.
Mayo Clin Proc ; 95(9): 1888-1897, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32861333

RESUMEN

OBJECTIVE: To provide an update on key safety metrics after transfusion of convalescent plasma in hospitalized coronavirus 2019 (COVID-19) patients, having previously demonstrated safety in 5000 hospitalized patients. PATIENTS AND METHODS: From April 3 to June 2, 2020, the US Food and Drug Administration Expanded Access Program for COVID-19 convalescent plasma transfused a convenience sample of 20,000 hospitalized patients with COVID-19 convalescent plasma. RESULTS: The incidence of all serious adverse events was low; these included transfusion reactions (n=78; <1%), thromboembolic or thrombotic events (n=113; <1%), and cardiac events (n=677, ~3%). Notably, the vast majority of the thromboembolic or thrombotic events (n=75) and cardiac events (n=597) were judged to be unrelated to the plasma transfusion per se. The 7-day mortality rate was 13.0% (12.5%, 13.4%), and was higher among more critically ill patients relative to less ill counterparts, including patients admitted to the intensive care unit versus those not admitted (15.6 vs 9.3%), mechanically ventilated versus not ventilated (18.3% vs 9.9%), and with septic shock or multiple organ dysfunction/failure versus those without dysfunction/failure (21.7% vs 11.5%). CONCLUSION: These updated data provide robust evidence that transfusion of convalescent plasma is safe in hospitalized patients with COVID-19, and support the notion that earlier administration of plasma within the clinical course of COVID-19 is more likely to reduce mortality.


Asunto(s)
Infecciones por Coronavirus/terapia , Seguridad del Paciente , Neumonía Viral/terapia , Adolescente , Adulto , Sistemas de Registro de Reacción Adversa a Medicamentos , Anciano , Anciano de 80 o más Años , COVID-19 , Infecciones por Coronavirus/mortalidad , Enfermedad Crítica , Femenino , Hospitalización , Humanos , Inmunización Pasiva/efectos adversos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/mortalidad , Estados Unidos , Adulto Joven , Sueroterapia para COVID-19
7.
J Clin Invest ; 130(9): 4791-4797, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32525844

RESUMEN

BACKGROUNDConvalescent plasma is the only antibody-based therapy currently available for patients with coronavirus disease 2019 (COVID-19). It has robust historical precedence and sound biological plausibility. Although promising, convalescent plasma has not yet been shown to be safe as a treatment for COVID-19.METHODSThus, we analyzed key safety metrics after transfusion of ABO-compatible human COVID-19 convalescent plasma in 5000 hospitalized adults with severe or life-threatening COVID-19, with 66% in the intensive care unit, as part of the US FDA expanded access program for COVID-19 convalescent plasma.RESULTSThe incidence of all serious adverse events (SAEs), including mortality rate (0.3%), in the first 4 hours after transfusion was <1%. Of the 36 reported SAEs, there were 25 reported incidences of related SAEs, including mortality (n = 4), transfusion-associated circulatory overload (n = 7), transfusion-related acute lung injury (n = 11), and severe allergic transfusion reactions (n = 3). However, only 2 of 36 SAEs were judged as definitely related to the convalescent plasma transfusion by the treating physician. The 7-day mortality rate was 14.9%.CONCLUSIONGiven the deadly nature of COVID-19 and the large population of critically ill patients included in these analyses, the mortality rate does not appear excessive. These early indicators suggest that transfusion of convalescent plasma is safe in hospitalized patients with COVID-19.TRIAL REGISTRATIONClinicalTrials.gov NCT04338360.FUNDINGMayo Clinic, Biomedical Advanced Research and Development Authority (75A50120C00096), National Center for Advancing Translational Sciences (UL1TR002377), National Heart, Lung, and Blood Institute (5R35HL139854 and R01 HL059842), National Institute of Diabetes and Digestive and Kidney Diseases (5T32DK07352), Natural Sciences and Engineering Research Council of Canada (PDF-532926-2019), National Institute of Allergy and Infectious Disease (R21 AI145356, R21 AI152318, and AI152078), Schwab Charitable Fund, United Health Group, National Basketball Association, Millennium Pharmaceuticals, and Octapharma USA Inc.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/terapia , Neumonía Viral/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19 , Ensayos de Uso Compasivo , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/mortalidad , Femenino , Humanos , Inmunización Pasiva/efectos adversos , Inmunización Pasiva/mortalidad , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/epidemiología , SARS-CoV-2 , Seguridad , Reacción a la Transfusión/epidemiología , Reacción a la Transfusión/etiología , Lesión Pulmonar Aguda Postransfusional/epidemiología , Lesión Pulmonar Aguda Postransfusional/etiología , Estados Unidos/epidemiología , United States Food and Drug Administration , Adulto Joven , Sueroterapia para COVID-19
8.
J Card Fail ; 26(10): 832-840, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32205188

RESUMEN

BACKGROUND: Exercise oscillatory ventilation (EOV) is a consequence of ventilatory control system instability and is commonly observed in patients with advanced heart failure (HF); it is associated with adverse prognosis. The goal of this study was to evaluate the effects of cardiac resynchronization therapy (CRT) on oscillatory ventilation as quantified by a proposed EOV score. METHODS AND RESULTS: Consecutive patients with HF (N = 35) who underwent clinically indicated CRT, cardiopulmonary exercise testing and carbon dioxide (CO2) chemosensitivity by rebreathe before and 4-6 months after CRT were included in this post hoc analysis. With CRT, EOV scores improved in 22 patients (63%). In these patients, left ventricular ejection fraction, left atrial volume, brain natriuretic peptide concentration, and CO2 chemosensitivity significantly improved after CRT (P < 0.05). Furthermore, minute ventilation per unit CO2 production significantly decreased, and end-tidal CO2 increased at rest and at peak exercise post-CRT. Multiple regression analysis showed only the change of CO2 chemosensitivity to be significantly associated with the improvement of the EOV score (b = 0.64; F = 11.3; P = 0.004). In the group without EOV score improvement (n = 13), though left ventricular ejection fraction significantly increased with CRT (P = 0.015), no significant changes in ventilation or gas exchange were observed. CONCLUSION: The EOV score was mitigated by CRT and was associated with decreased CO2 chemosensitivity.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Prueba de Esfuerzo , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico , Función Ventricular Izquierda
9.
Pacing Clin Electrophysiol ; 42(3): 366-373, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30632622

RESUMEN

BACKGROUND: Leadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers. METHODS: Patients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age- and sex-matched controls receiving single-chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA). RESULTS: Ninety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow-up duration of 62 (interquartile range 28-169) days. Both groups had 100% successful device implant rates. There were no differences in procedure-related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device-related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017). CONCLUSION: There are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device-related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Diseño de Equipo , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Torácicos , Estados Unidos
10.
Heart Rhythm ; 15(11): 1593-1600, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30654978

RESUMEN

BACKGROUND: Stroke can be a devastating complication in patients with cardiovascular implantable electronic device (CIED) infection. Paradoxical septic embolism can occur in the presence of device leads and patent foramen ovale (PFO) via embolic dislodgment during transvenous lead removal (TLR). OBJECTIVE: The purpose of this study was to examine stroke and its associated factors in patients undergoing TLR for CIED infection. METHODS: We performed a retrospective analysis of all patients undergoing TLR for CIED infection from January 1, 2000, to July 30, 2017, from all 3 tertiary referral centers at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). The primary outcome was stroke and was further categorized into preprocedural and postprocedural stroke. Associated risk factors were analyzed. RESULTS: A total of 774 patients (mean age 67.6 ± 14.9 years) underwent TLR for CIED infection. The stroke rate in this cohort was 1.9% (95% confidence interval [CI] 1.1%-3.2%). The preprocedural and postprocedural stroke rate was 0.9% (95% CI 0.4%-1.9%) and 1.0% (95% CI 0.4%-2.0%), respectively. PFOs were identified in 46.7% of patients with stroke and in 12.9% of patients without stroke, and were independently associated with stroke (P = .0002). This was especially in patients with right-sided vegetations with right-to-left shunting (odds ratio 6.4; 95% CI 1.3-31.0; P = .022). CONCLUSION: In patients with CIED infection undergoing TLR, the presence of PFO, especially with right-sided vegetation with right-to-left shunting, was associated with an increased risk of stroke. This finding suggests that PFO screening before TLR warrants meticulous attention.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Remoción de Dispositivos/métodos , Endocarditis Bacteriana/complicaciones , Accidente Cerebrovascular/etiología , Anciano , Dispositivos de Terapia de Resincronización Cardíaca/microbiología , Ecocardiografía Transesofágica , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/cirugía , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
12.
Ann Thorac Surg ; 104(4): 1259-1264, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28433222

RESUMEN

BACKGROUND: The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. METHODS: This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. RESULTS: The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p < 0.001). CONCLUSIONS: Early pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients.


Asunto(s)
Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Mortalidad , Marcapaso Artificial/efectos adversos , Anciano , Puente de Arteria Coronaria , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Análisis Multivariante , Estudios Retrospectivos , Factores de Tiempo
13.
J Card Fail ; 21(5): 367-373, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25576681

RESUMEN

BACKGROUND: Heart failure (HF) is characterized by heightened sensitivities of the CO2 chemoreflex and the ergoreflex which promote increased ventilatory drive manifested as increased minute ventilation per volume of expired CO2 (VE/VCO2). The aims of this study were to evaluate the effects of cardiac resynchronization therapy (CRT) on carbon dioxide (CO2) chemosensitivity and the arterial CO2 setpoint. METHODS AND RESULTS: Consecutive HF patients (n = 35) who underwent clinically indicated CRT were investigated by means of cardiopulmonary exercise testing and CO2 chemosensitivity evaluation with the use of a rebreathe method before and 4-6 months after CRT. Pre- and post-CRT measures were compared with the use of either paired t test or Wilcoxon test. Decreased peak VE/VCO2 (44 ± 10 vs 40 ± 8; P < .01), CO2 chemosensitivity (2.2 ± 1.1 vs 1.7 ± 0.8 L min(-1) mm Hg(-1); P = .04), and increased peak end-tidal CO2 (29 ± 5 vs 31 ± 5 mm Hg; P < .01) were also observed after CRT. Multivariate analysis adjusted for age and sex showed the decrease of peak VE/VCO2 from before to after CRT to be most strongly associated with the increase of peak end-tidal CO2 (ß = -0.84; F = 21.5; P < .0001). CONCLUSIONS: Decrease of VE/VCO2 after CRT is associated with decreased CO2 chemosensitivity and increase of the arterial CO2 setpoint, which is consistent with decreased activation of both the CO2 chemoreflex and the ergoreflex.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Ventilación Pulmonar/fisiología , Anciano , Análisis de los Gases de la Sangre/métodos , Dióxido de Carbono/metabolismo , Prueba de Esfuerzo/métodos , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/fisiología
14.
Pacing Clin Electrophysiol ; 36(9): 1061-7, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23822919

RESUMEN

BACKGROUND: Patients with preexisting mild cognitive impairment or dementia may be at increased risk for developing cardiac device complications due to an impaired ability to follow postimplant care instructions. We sought to determine whether rates of infection, lead dislodgement, or appropriate or inappropriate implantable cardioverter defibrillator (ICD) shocks are increased in this population. METHODS: Medical charts of 561 patients with mild cognitive impairment or dementia who underwent pacemaker (PM) or ICD implantation between January 2002 and October 2009 at Mayo Clinic were identified. A total of 134 patients who were diagnosed with cognitive impairment or dementia before device implantation or within 1 year of implantation were compared with 134 matched controls. Information was collected on patient characteristics, comorbid medical conditions, ejection fraction, complications, device type, device therapy, and mortality. Device information was prospectively entered into a database and retrospectively reviewed. RESULTS: Of the 134 patients with mild cognitive impairment and dementia, 99 underwent PM implantation and 35 underwent ICD implantation. Compared to controls, there was no difference in patient characteristics, ejection fraction, or comorbidities except for diabetes, which was more prevalent in the cognitively impaired and demented group (18.7% vs 30.6%, P = 0.02). There was no difference in device therapy and complications (14.4% vs 5.8%, P = 0.268). However, there was a decreased survival in patients with cognitive impairment and dementia when compared to the control group (42% vs 67% at 5 years, P = 0.007). CONCLUSION: Patients with cognitive impairment and standard device indications are not at increased risk for device complications and therapy but their survival is much lower than in matched controls. The cause of this lower survival is unknown but may be related to the underlying neurological disease. Presence of cognitive impairment should therefore be considered when contemplating implantation of a cardiac device.


Asunto(s)
Trastornos del Conocimiento/mortalidad , Desfibriladores Implantables/estadística & datos numéricos , Demencia/mortalidad , Traumatismos por Electricidad/mortalidad , Marcapaso Artificial/estadística & datos numéricos , Infecciones Relacionadas con Prótesis/mortalidad , Sistema de Registros , Adulto , Anciano , Anciano de 80 o más Años , Causalidad , Trastornos del Conocimiento/psicología , Trastornos del Conocimiento/rehabilitación , Comorbilidad , Desfibriladores Implantables/psicología , Demencia/psicología , Demencia/rehabilitación , Traumatismos por Electricidad/psicología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Minnesota/epidemiología , Marcapaso Artificial/psicología , Cooperación del Paciente/psicología , Cooperación del Paciente/estadística & datos numéricos , Falla de Prótesis , Infecciones Relacionadas con Prótesis/psicología , Estudios Retrospectivos , Factores de Riesgo , Análisis de Supervivencia , Tasa de Supervivencia
15.
Am J Cardiol ; 112(6): 838-42, 2013 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-23747043

RESUMEN

Pulmonary congestion due to heart failure causes abnormal lung function. Cardiac resynchronization therapy (CRT) is a proven effective treatment for heart failure. The aim of this study was to test the hypothesis that CRT promotes increased lung volumes, bronchial conductance, and gas diffusion. Forty-four consecutive patients with heart failure were prospectively investigated before and after CRT. Spirometry, gas diffusion (diffusing capacity for carbon monoxide), cardiopulmonary exercise testing, New York Heart Association class, brain natriuretic peptide, the left ventricular ejection fraction, left atrial volume, and right ventricular systolic pressure were assessed before and 4 to 6 months after CRT. Pre- and post-CRT measures were compared using either paired Student's t tests or Wilcoxon's matched-pair test; p values <0.05 were considered significant. Improved New York Heart Association class, left ventricular ejection fraction, left atrial volume, right ventricular systolic pressure, and brain natriuretic peptide were observed after CRT (p <0.05 for all). Spirometry after CRT demonstrated increased percentage predicted total lung capacity (90 ± 17% vs 96 ± 15%, p <0.01) and percentage predicted forced vital capacity (80 ± 19% vs 90 ± 19%, p <0.01). Increased percentage predicted total lung capacity was significantly correlated with increased peak exercise end-tidal carbon dioxide (r = 0.43, p = 0.05). Increased percentage predicted forced vital capacity was significantly correlated with decreased right ventricular systolic pressure (r = -0.30, p = 0.05), body mass index (r = -0.35, p = 0.02) and creatinine (r = -0.49, p = 0.02), consistent with an association of improved bronchial conductance and decreased congestion. Diffusing capacity for carbon monoxide did not significantly change. In conclusion, increased lung volumes and bronchial conductance due to decreased pulmonary congestion and increased intrathoracic space contribute to an improved breathing pattern and decreased hyperventilation after CRT. Persistent alveolar-capillary membrane remodeling may account for unchanged diffusing capacity for carbon monoxide.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Pulmón/fisiopatología , Insuficiencia Respiratoria/fisiopatología , Fenómenos Fisiológicos Respiratorios , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Pronóstico , Pruebas de Función Respiratoria , Insuficiencia Respiratoria/etiología , Índice de Severidad de la Enfermedad
16.
Heart Rhythm ; 10(5): 696-701, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23333719

RESUMEN

BACKGROUND: Sudden death may occur after radiofrequency catheter ablation of the atrioventricular node (AVN) and permanent pacemaker implantation. It is unclear whether a faster initial heart rate with gradual rate reduction decreases the risk of sudden death. OBJECTIVE: To evaluate the effects of initial pacing at a faster rate after AVN ablation, with a gradual rate decrease over 3 months, on the rate of sudden death in patients with atrial fibrillation. METHODS: We compared the rate of likely or possible procedure-related sudden death in 2 groups of patients who had AVN ablation and pacemaker implantation. The study cohort was treated between January 2005 and December 2009, and pacemakers were programmed to a lower rate of 90 beats/min after the procedure, with a monthly decrement of 10 beats/min until 60 beats/min was reached. The control group was treated between July 1990 and December 1998 when pacemakers were programmed to a lower rate of 60 beats/min immediately after ablation. RESULTS: The study cohort included 520 patients (mean age 73.6 ± 10.3 years), and the control cohort comprised 334 patients (mean age 68.1 ± 1.1 years). Sudden death deemed likely or possibly related to ablation and pacemaker implantation occurred in 1 patient in the study cohort (0.2%) and in 7 patients (2.1%) in the control group (P = .007). CONCLUSIONS: Sudden death was significantly decreased in the study cohort compared to controls. The faster lower pacing rate immediately after AVN ablation with a gradual decrease is a plausible mechanism for the improved clinical outcome.


Asunto(s)
Fibrilación Atrial/terapia , Nodo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ablación por Catéter/métodos , Muerte Súbita/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/mortalidad , Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Estudios de Cohortes , Muerte Súbita/etiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia
17.
J Interv Card Electrophysiol ; 35(1): 93-100, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22584767

RESUMEN

With increasing coronary sinus (CS) pacemaker leads for cardiac resynchronization therapy, the need to remove these leads has risen. The purpose of this study is to describe a single center's experience with CS lead removal and to attempt to identify predictors of difficulty with lead removal and complications. We reviewed all percutaneous endocardial CS lead removals performed at our institution through February 2010. Successful removal with traction alone was considered simple while complex extractions required traction devices and/or laser sheaths. Between December 1996 and February 2010, 125 CS leads were percutaneously removed ≥1 week post-implantation from 115 patients. One attempt at CS lead extraction was unsuccessful. The average duration since implantation for the CS leads was 1.54 years (± .75 years, range 8 days to 8.24 years). The majority of the leads were removed by simple traction (n = 114, 91.2 %). The remainder were removed by femoral approach with snare (n = 3, 2.4 %), locking stylet (n = 2, 1.6 %), or locking stylet and laser sheath (n = 6, 4.8 %). Half of CS leads in place greater than 4 years required complex extraction (n = 7/14, 50 %). CS complications (n = 11 patients, 8.8 %) included CS or tributary thrombosis (n = 7/102, 6.9 %) and CS dissection (n = 4/102, 3.9 %). Major non-CS complications (n = 2 patients, 1.6 %) included a cardiac tear requiring pericardiocentesis and thoracotomy (n = 1, 0.8 %) and subclavian vein tear requiring surgical repair (n = 1, 0.8 %). Minor non-CS complications (n = 9 patients, 7.2 %) included a pneumothorax (n = 1, 0.8 %), hematoma (n = 2, 1.6 %), subclavian vein thrombosis (n = 3, x%), and blood transfusion (n = 5, 4.0 %). A longer duration since implantation and larger lead diameter were associated with complex versus simple removal (p < .0001 and p = .0009 respectively). Percutaneous CS lead removal is successful by simple traction alone in the vast majority of cases. CS leads in place greater than 4 years, however, often require complex extraction. Specific extraction techniques can be implemented when simple traction is unsuccessful without an appreciable increase in complications.


Asunto(s)
Seno Coronario , Remoción de Dispositivos/métodos , Electrodos Implantados , Marcapaso Artificial , Anciano , Distribución de Chi-Cuadrado , Remoción de Dispositivos/efectos adversos , Femenino , Humanos , Masculino , Resultado del Tratamiento
18.
Pacing Clin Electrophysiol ; 35(7): 827-33, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22548372

RESUMEN

INTRODUCTION: Pacemaker therapy is effective in reducing recurrent syncope in patients with symptomatic carotid sinus hypersensitivity (CSH), yet the optimal pacing modality for this syndrome is not known. The objective of this study is to prospectively investigate the impact of three pacing methods (DDDR vs DDDR with sudden bradycardia response [SBR] vs VVI) on recurrent syncope and quality of life. METHODS: Twenty-one patients with symptomatic CSH (syncope or near syncope) were randomized to VVI, DDDR, or DDDR with SBR on a double-blinded basis in a sequential crossover fashion with 6 months in each mode. The primary endpoints were recurrent events and quality of life (assessed by SF-36). The mean number of events and SF-36 scores were compared. RESULTS: At baseline, over the preceding 6 months, there were a total of 29 syncopal events and 258 presyncopal events among 21 patients. Following pacing in any mode, the total number of these syncopal events reduced to two in two patients (P < 0.001) and 17 presyncopal events (P < 0.001) in 12 patients. The mean number of events was not significantly different between the three pacing methods. SF-36 scores revealed some minor benefits of DDDR pacing versus baseline in the categories, but no pacing method was found to be superior. CONCLUSIONS: The study was unable to confirm the initial study hypothesis of a superiority of one pacing modality over another. Quality of life measures allude to potential benefit from DDDR pacing alone.


Asunto(s)
Algoritmos , Estimulación Cardíaca Artificial/métodos , Electrocardiografía/métodos , Síncope/diagnóstico , Síncope/prevención & control , Terapia Asistida por Computador/métodos , Anciano , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Prevención Secundaria , Sensibilidad y Especificidad
19.
Europace ; 14(8): 1139-47, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22467754

RESUMEN

AIMS: We sought to determine the clinical and survival outcomes of cardiac resynchronization therapy (CRT) associated with left ventricular (LV) lead location. The lateral left ventricle has been considered the optimal LV lead location for CRT. METHODS AND RESULTS: Left ventricular lead cinegrams taken in 30° right and left anterior oblique views were evaluated in 457 recipients of CRT with a pacemaker or a defibrillator from 1 January 2002 to 31 December 2008 in this retrospective study. Left ventricular lead placement was prioritized at implantation into posterolateral (PL), anterolateral (AL), middle cardiac, and anterointerventricular coronary veins. Using echocardiographic LV 16-segment analysis, we grouped the leads as anterior, AL, PL, and posterior locations. New York Heart Association (NYHA) class and echocardiography were assessed before and after CRT. Clinical and survival outcomes after CRT were compared among the four LV lead locations.  Patient baseline demographic characteristics were similar among these four groups. Improvement in NYHA class was significantly greater in the AL (P= 0.04) and PL (P= 0.03) locations than in the anterior location. There was a tendency for greater improvement in LV ejection fraction among the AL (P= 0.11) and PL (P= 0.08) locations than the anterior location. Kaplan-Meier survival estimate at 4 years varied for location: AL, 72%; anterior, 48%; PL, 62%; and posterior, 72% (P= 0.003). CONCLUSION: Cardiac resynchronization therapy recipients are profiting from all lead positions. However, LV lead placed in the AL and PL positions is more preferential for achieving optimal CRT benefit than leads placed in the anterior position.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Anciano , Terapia de Resincronización Cardíaca/mortalidad , Ecocardiografía , Electrodos Implantados , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos , Humanos , Masculino , Estudios Retrospectivos , Volumen Sistólico , Análisis de Supervivencia
20.
J Interv Card Electrophysiol ; 33(1): 59-67, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21938517

RESUMEN

OBJECTIVE: This study aimed to characterize the interactions of pacemakers with magnetic resonance imaging (MRI) and to identify device characteristics that could predict adverse interactions. BACKGROUND: The safety of MRI in patients with indwelling pacemaker systems remains uncertain. Previous studies demonstrated safety in most patients, but unpredictable, potentially concerning changes in pacemaker behavior have occurred. METHODS: We prospectively studied patients with pacemaker devices in situ who were not pacemaker dependent and in whom MRI was essential for adequate diagnosis and treatment. All patients were monitored by electrocardiography and pulse oximetry during scanning; devices were interrogated and cardiac enzymes were measured before and after scanning. RESULTS: Of 32 patients studied (46 MRI examinations), 28 patients had a dual-chamber system and one had a biventricular device. Regions scanned were the head and spine. Devices were reprogrammed to asynchronous pacing or sense-only mode in all except six patients before MRI. During six scanning episodes (five patients), "power-on" resetting of the device was noted. Magnet-mode pacing was noted during four episodes (three patients). Occasional premature ventricular contractions were noted in one patient. No significant changes in battery voltage, sensed P wave and R wave, pacing thresholds, lead impedance, or cardiac enzymes were noted immediately after MRI or at 1-month follow-up. CONCLUSIONS: Overall, no significant changes were seen in pacemaker device function, and no adverse clinical events were observed. A minority of patients with older devices had unpredictable changes in device behavior, which stresses the need for close monitoring during and careful device interrogation after scanning.


Asunto(s)
Imagen por Resonancia Magnética , Marcapaso Artificial , Seguridad del Paciente , Anciano , Contraindicaciones , Femenino , Humanos , Imagen por Resonancia Magnética/efectos adversos , Masculino , Monitoreo Fisiológico , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA