Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 3 de 3
1.
Sensors (Basel) ; 23(13)2023 Jun 25.
Article En | MEDLINE | ID: mdl-37447718

This study aims to evaluate the feasibility and explore the efficacy of the Arm Activity Tracker (AAT). The AAT is a device based on wrist-worn accelerometers that provides visual and tactile feedback to stimulate daily life upper extremity (UE) activity in stroke patients. METHODS: A randomised, crossover within-subject study was conducted in sub-acute stroke patients admitted to a rehabilitation centre. Feasibility encompassed (1) adherence: the dropout rate and the number of participants with insufficient AAT data collection; (2) acceptance: the technology acceptance model (range: 7-112) and (3) usability: the system usability scale (range: 0-100). A two-way ANOVA was used to estimate the difference between the baseline, intervention and control conditions for (1) paretic UE activity and (2) UE activity ratio. RESULTS: Seventeen stroke patients were included. A 29% dropout rate was observed, and two participants had insufficient data collection. Participants who adhered to the study reported good acceptance (median (IQR): 94 (77-111)) and usability (median (IQR): 77.5 (75-78.5)-). We found small to medium effect sizes favouring the intervention condition for paretic UE activity (η2G = 0.07, p = 0.04) and ratio (η2G = 0.11, p = 0.22). CONCLUSION: Participants who adhered to the study showed good acceptance and usability of the AAT and increased paretic UE activity. Dropouts should be further evaluated, and a sufficiently powered trial should be performed to analyse efficacy.


Stroke Rehabilitation , Stroke , Humans , Feasibility Studies , Feedback , Upper Extremity , Recovery of Function
2.
Sensors (Basel) ; 21(13)2021 Jun 25.
Article En | MEDLINE | ID: mdl-34202142

Wrist-worn accelerometers are often applied to measure arm use after stroke. They measure arm movements during all activities, including whole-body movements, such as walking. Whole-body movements may influence clinimetric properties of arm use measurements-however, this has not yet been examined. This study investigates to what extent arm use measurements with wrist-worn accelerometers are affected by whole-body movements. Assuming that arm movements during whole-body movements are non-functional, we quantify the effect of whole-body movements by comparing two methods: Arm use measured with wrist-worn accelerometers during all whole-body postures and movements (P&M method), and during sitting/standing only (sit/stand method). We have performed a longitudinal observational cohort study with measurements in 33 stroke patients during weeks 3, 12, and 26 poststroke. The P&M method shows higher daily paretic arm use outcomes than the sit/stand method (p < 0.001), the mean difference increased from 31% at week three to 41% at week 26 (p < 0.001). Differences in daily paretic arm use between methods are strongly related to daily walking time (r = 0.83-0.92). Changes in the difference between methods are strongly related to changes in daily walking time (r = 0.89). We show that not correcting arm use measurements for whole-body movements substantially increases arm use outcomes, thereby threatening the validity of arm use outcomes and measured arm use changes.


Stroke Rehabilitation , Stroke , Accelerometry , Arm , Humans , Upper Extremity , Wrist , Wrist Joint
3.
Sensors (Basel) ; 21(14)2021 Jul 12.
Article En | MEDLINE | ID: mdl-34300484

Motor disorders are a common and age-related problem in the general community [...].


Movement , Wearable Electronic Devices , Technology
...