Catheter Cardiovasc Interv ; 55(2): 133-9, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11835634

RESUMEN

The objective of this study was to evaluate the early angiographic outcome in the first human subjects who underwent intracoronary atherectomy and thrombectomy using the X-Sizer helical cutting and aspiration system. Percutaneous coronary interventions in patients with thrombo-occlusive disease or friable degenerative saphenous vein grafts are associated with considerable periprocedural morbidity and mortality, predominantly related to microscopic distal embolization. X-Sizer catheter system is a novel atherectomy and thrombectomy device that consists of a helix cutter connected to a handheld motor drive unit and a vacuum collection chamber for aspiration of excised atheroma, thrombus, and debris. Quantitative coronary angiography was obtained in 14 patients before and after X-Sizer extraction atherectomy with adjunctive balloon angioplasty and stenting. Thirteen native coronary arteries and one saphenous vein graft were treated. Mean preprocedural reference vessel diameter was 3.06 +/- 0.66 mm. There were 71.4% AHA/ACC type B2 and C lesions. Preprocedural thrombus was present in nine patients and total occlusion in 64% of cases. Minimal luminal diameter was increased from 0.29 +/- 0.47 mm to 1.32 +/- 0.64 mm, a gain of 1.04 +/- 0.69 mm after atherectomy. Final total gain was 1.47 +/- 0.61 mm. Mean diameter stenosis was reduced from 89.3% to a final residual stenosis of 14.4%. Postatherectomy distal embolization occurred in one patient who had heavy preprocedural thrombus burden. No episodes of perforation, distal coronary spasm, abrupt closure, or slow/no-reflow occurred. The angiographic analysis of the first cohort of human subjects suggests that X-Sizer helical atherectomy is a feasible method of removing occlusive tissue or thrombus in coronary artery disease with a low angiographic complication rate. A large-scale randomized phase II clinical trial is underway to determine the ultimate safety and efficacy of this device in thrombo-occlusive native coronary arteries and saphenous vein grafts.


Asunto(s)
Aterectomía Coronaria/instrumentación , Catéteres de Permanencia , Angiografía Coronaria , Trombectomía/instrumentación , Angioplastia Coronaria con Balón/instrumentación , Prótesis Vascular , Angiografía Coronaria/efectos adversos , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/cirugía , Trombosis Coronaria/complicaciones , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/terapia , Diseño de Equipo , Europa (Continente)/epidemiología , Humanos , Incidencia , Recurrencia , Reoperación , Vena Safena/diagnóstico por imagen , Vena Safena/trasplante , América del Sur/epidemiología , Stents , Resultado del Tratamiento , Grabación de Cinta de Video
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA