1.
Microbiol Spectr ; : e0420123, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38842363

RESUMEN

Quantitation of cytomegalovirus (CMV) DNA load in specimens other than blood such as bronchoalveolar lavages, intestinal biopsies, or urine has become a common practice as an ancillary tool for the diagnosis of CMV pneumonitis, intestinal disease, or congenital infection, respectively. Nevertheless, most commercially available CMV PCR platforms have not been validated for CMV DNA detection in these specimen types. In this study, a laboratory-developed test based on Alinity m CMV ("Alinity LDT") was evaluated. Reproducibility assessment using spiked bronchial aspirate (BAS) or urine samples showed low standard deviations of 0.08 and 0.27 Log IU/mL, respectively. Evaluating the clinical performance of Alinity LDT in comparison to a laboratory-developed test based on RealTime CMV ("RealTime LDT") showed good concordance across 200 clinical specimens including respiratory specimens, intestinal biopsies, urine, and stool. A high Pearson's correlation coefficient of r = 0.92, a low mean bias of -0.12 Log IU/mL, a good qualitative agreement of 90%, and a Cohen's kappa value of 0.76 (substantial agreement) were observed. In separate analyses of the sample types BAS, tracheal aspirates, bronchoalveolar lavage, biopsies, and urine, the assay results correlated well between the two platforms with r values between 0.88 and 0.99 and a bias <0.5 Log IU/mL. Overall, the fully automated, continuous, random access Alinity LDT yielded good reproducibility, high concordance, and good correlation to RealTime LDT in respiratory, gastrointestinal, and urine samples and may enhance patient management with rapid result reporting.IMPORTANCEIn transplant recipients, a major cause for morbidity and mortality is end-organ disease by primary or secondary CMV infection of the respiratory or gastrointestinal tract. In addition, sensorineural hearing loss and neurodevelopmental abnormalities are frequent sequelae of congenital CMV infections in newborns. Standard of care for highly sensitive detection and quantitation of the CMV DNA load in plasma and whole blood specimens is real-time PCR testing. Beyond that, there is a need for quantitative determination of CMV DNA levels in respiratory, gastrointestinal, and urinary tract specimens using a highly automated, random access CMV PCR assay with a short turnaround time to enable early diagnosis and treatment. In the present study, clinical performance of the fully automated Alinity m analyzer in comparison to the current RealTime LDT assay was evaluated in eight different off-label sample types.

2.
Heliyon ; 9(11): e22112, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38034696

RESUMEN

Background: Cycle threshold (Ct) values from SARS-CoV-2 nucleic acid amplification tests have been used to estimate viral load for treatment decisions. Additionally, there is a need for high-throughput testing, consolidating a variety of assays on one random-access analyzer. Objectives: In this study, the clinical performance of the Alinity m SARS-CoV-2, RealTime SARS-CoV-2, and GeneXpert Xpress SARS-CoV-2/Flu/RSV assays was assessed. Methods: Alinity precision and detection rates were evaluated using a dilution series of the Alinity m SARS-CoV-2 positive control. In a retrospective study, 7 remnant external quality assessment (EQA) specimens and 200 remnant nasopharyngeal swab specimens (100 positive and 100 negative) were tested in the three assays. Results: Alinity had 100 % detection rate at 50 copies/mL and high reproducibility (Ct value coefficient of variation ≤3.1 %). All three assays correctly detected positive and negative EQA samples with comparable Ct values (max difference 2.38) and high linearity. In patient samples, positive percent agreement was 95 % (95 % CI 89-98 %) and negative percent agreement was 100 % (95 % CI 96-100 %) for Alinity, compared to the other two assays. Four specimens detected on Alinity m but not RealTime or Xpert had Ct values above 40. Assay results were highly correlated (r ≥ 0.94). Ct values (after addition of 10 unread cycles to the reported Ct of RealTime) were comparable across the three assays. Conclusions: Alinity m had high precision and accuracy and Ct values comparable to those of the RealTime and Xpert assays. The assays could be used interchangeably, with no need for adjustment of patient management decisions based on Ct values from each assay.

3.
J Clin Microbiol ; 61(10): e0041523, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37728341

RESUMEN

Monitoring of cytomegalovirus (CMV) viral load is critical for informing treatment decisions in order to prevent the severe health consequences of CMV infection or reactivation of latent CMV in immunocompromised individuals. This first field evaluation examined the analytical and clinical performance of the Alinity m CMV assay. Analytical performance was assessed with a commercially available six-member panel, while the clinical performance evaluation compared the Alinity m CMV assay to the RealTime CMV assay and a laboratory-developed test (LDT) as the test of record at three large hospital-based clinical laboratories. Precision of the Alinity m CMV assay was demonstrated with total standard deviation (SD) between 0.08 and 0.28 Log IU/mL. A total of 457 plasma specimens were tested on the Alinity m CMV assay and compared to the test of record at each site (n = 304 with RealTime CMV and n = 153 with LDT CMV). The Alinity m CMV assay had excellent correlation (correlation coefficient r ≥0.942) in comparison to the RealTime CMV or LDT CMV assays. The mean observed bias ranged from -0.03 to 0.34 Log IU/mL. Median onboard turnaround time of Alinity m CMV was less than 3 h. When the CMV assay is run on the Alinity m system, it has the capacity to shorten time to result and, therefore, to therapy.


Asunto(s)
Infecciones por Citomegalovirus , Citomegalovirus , Humanos , Citomegalovirus/genética , Carga Viral , Infecciones por Citomegalovirus/diagnóstico , ADN , Huésped Inmunocomprometido , ADN Viral/genética , Sensibilidad y Especificidad
4.
J Clin Microbiol ; 61(10): e0047223, 2023 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-37728343

RESUMEN

Detection and monitoring of acute infection or reactivation of Epstein-Barr virus (EBV) are critical for treatment decision-making and to reduce the risk of EBV-related malignancies and other associated diseases in immunocompromised individuals. The analytical and clinical performance of the Alinity m EBV assay was evaluated at two independent study sites; analytical performance was assessed by evaluating precision with a commercially available 5-member EBV verification panel, while the clinical performance of the Alinity m EBV assay was compared to the RealTime EBV assay and a laboratory-developed test (LDT) as the routine test of record (TOR). Analytical analysis demonstrated standard deviation (SD) between 0.08 and 0.13 Log IU/mL. A total of 300 remnant plasma specimens were retested with the Alinity m EBV assay, and results were compared to those of the TOR at the respective study sites (n = 148 with the RealTime EBV assay and n = 152 with the LDT EBV assay). Agreement between Alinity m EBV and RealTime EBV or LDT EBV assays had kappa values of 0.88 and 0.84, respectively, with correlation coefficients r of 0.956 and 0.912, while the corresponding observed mean bias was -0.02 and -0.19 Log IU/mL. The Alinity m EBV assay had a short median onboard turnaround time of 2:40 h. Thus, the Alinity m system can shorten the time to results and, therefore, to therapy.


Asunto(s)
Infecciones por Virus de Epstein-Barr , Herpesvirus Humano 4 , Humanos , Herpesvirus Humano 4/genética , Infecciones por Virus de Epstein-Barr/diagnóstico , ADN Viral , Sensibilidad y Especificidad
5.
J Virol Methods ; 299: 114338, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34695479

RESUMEN

BACKGROUND: Detection of SARS-CoV-2 infections relies on the use of sensitive, accurate and high throughput RT-PCR assays. OBJECTIVES: We assessed the analytical performance of the Abbott RealTime SARS-CoV-2 (RT-SARS), Alinity m SARS-CoV-2 (AlinSARS) assays and compared the clinical performance of the RT-SARS, AlinSARS, and Alinity m Resp-4-Plex (Alin4Plex) assays to the Seegene Allplex assay (Allplex) and an inhouse test (Inhouse). RESULTS: We found 100 % positive percent agreement (PPA) and 100 % negative percent agreement (NPA) comparing RT-SARS and Allplex. RT-SARS, AlinSARS and Inhouse showed 100 % NPA and 100 % PPA across all assays, except for the RdRp target of Inhouse (PPA = 84 %). Similarly, Alin4Plex and Allplex showed high agreement with specimens containing either SARS-CoV-2, influenza A, influenza B, or RSV. Detection rates of 100 % for SARS-CoV-2 at 50 copies/mL, high precision, and no cross-reactivity with non-SARS-CoV-2 respiratory pathogens were observed for RT-SARS and AlinSARS. AlinSARS detected SARS-CoV-2 in spiked throat washes and in specimens infected with SARS-CoV-2 Alpha or Beta variants. CONCLUSIONS: The newly developed RT-SARS, AlinSARS, and Alin4Plex assays proved to be useful for detecting SARS-CoV-2 RNA in clinical samples.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , ARN Viral/genética , Sensibilidad y Especificidad
6.
J Clin Virol ; 132: 104644, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32992087

RESUMEN

BACKGROUND: Regular HIV-1 viral load monitoring forms an essential part of any successful HIV-1 treatment programme. Abbott Molecular recently released the Alinity m HIV-1 assay to be run on the Alinity m System, a fully automated, continuous and random access analyser using ReadiFlex™ technology. OBJECTIVES: Our study investigated the performance of the Alinity m HIV-1 assay in comparison to the cobas® HIV-1 test in a high-throughput molecular laboratory. STUDY DESIGN: We compared the performance of the Alinity m HIV-1 assay with the cobas® HIV-1 test, performed on both the cobas® 4800 and cobas® 6800 systems at three clinically relevant thresholds (50, 200 and 1000 cp/mL). RESULTS: Excellent correlation (r = 0.98) and agreement (mean bias -0.004 Log10 cp/mL) was achieved between the cobas® 4800 and Alinity m HIV-1 assay. While there was good correlation between the Alinity m HIV-1 assay and the cobas® 6800 (r = 0.99), Bland-Altman analysis indicated that the cobas® 6800 on average measured 0.22 Log10 cp/mL higher than the Alinity m HIV-1 assay across the dynamic range. Percentage agreement was excellent at the 200 cp/mL and 1000 cp/mL thresholds and was slightly lower at 50 cp/mL in comparison with the cobas® systems. CONCLUSIONS: The Alinity m HIV-1 assay compared well with the cobas® HIV-1 test on both the cobas® 4800 and cobas® 6800 systems in a high-throughput molecular laboratory in South Africa, a low- to middle-income country.


Asunto(s)
Infecciones por VIH , VIH-1 , Infecciones por VIH/diagnóstico , VIH-1/genética , Humanos , Laboratorios , ARN , ARN Viral , Juego de Reactivos para Diagnóstico , Sensibilidad y Especificidad , Sudáfrica , Carga Viral
7.
J Clin Virol ; 129: 104514, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32688328

RESUMEN

BACKGROUND: Accurate molecular methods to detect and quantify hepatitis B virus (HBV) DNA are essential to diagnose chronic infections, guide treatment decisions, assess response to treatment, and determine risk of HBV-related complications. New generations of real-time HBV DNA assay platforms provide results in less than 2-3 h, with continuous loading of specimens and true random-access capability. OBJECTIVES: We examined the clinical performance of the new Alinity m HBV assay, run on the fully automated, continuous, random-access Alinity m platform, to accurately detect and quantify HBV DNA in a large series of patient samples infected with different HBV genotypes frequently encountered in clinical practice. STUDY DESIGN: This international, multisite study assessed the precision and reproducibility of the Alinity m HBV assay and compared its performance to four HBV assays currently in clinical use. RESULTS: The Alinity m HBV assay demonstrated linear quantitation of HBV DNA in plasma samples, with high precision (coefficient of variation 4.1 %-8.8 %) and reproducibility. The Alinity m HBV assay showed excellent correlation (correlation coefficients ≥0.947) with comparator HBV assays, with an overall observed bias ranging from -0.07 to 0.17 Log10 IU/mL. 97 % of quantifiable patient results were <1 Log10 IU/mL different than the respective comparator assays, with comparable results across HBV genotypes. CONCLUSIONS: The newly developed real-time PCR-based Alinity m HBV assay is sensitive, reproducible, and accurately quantifies HBV DNA levels from HBsAg-positive patients across the full dynamic range of quantification.


Asunto(s)
Virus de la Hepatitis B , Hepatitis B , ADN Viral , Virus de la Hepatitis B/genética , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Viral
8.
J Clin Virol ; 129: 104531, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32688330

RESUMEN

BACKGROUND: Nucleic acid testing is essential for the detection and quantification of HCV RNA in the diagnosis of HCV infection and treatment monitoring. The Alinity m HCV assay was recently developed by Abbott Molecular for rapid detection and quantification of HCV RNA on the fully automated, continuous, random-access Alinity m analyzer. OBJECTIVES: Our study assessed the performance of the new Alinity m HCV assay for detection and quantification of HCV RNA in a large series of patient samples of various genotypes. This international, multicentric study evaluated the linearity, precision, and reproducibility of the Alinity m HCV assay and its performance in comparison to three other HCV assays currently used in clinical practice. RESULTS: The Alinity m HCV assay demonstrated high linearity (correlation coefficient r = 1.00), precision (coefficients of variation [CV] 6.6-13.5 %) and reproducibility (CV 1.7-4.3 % across three control lots). At a concentration near the lower limit of detection, the Alinity m HCV assay exhibited >98 % detectability. The Alinity m HCV assay showed excellent correlation with comparator HCV assays in serum (n = 406) and plasma (n = 1401) samples (correlation coefficients ≥0.96, bias 0.01 to 0.14 Log10 IU/mL). More than 95 % of the quantified results with the Alinity m HCV assay were less than mean bias ± 1.96 SD different from those of the comparator assays. CONCLUSIONS: The newly developed Alinity m HCV assay is sensitive, reproducible, and accurately quantifies HCV RNA levels in serum and plasma samples from patients with chronic HCV infection, with no impact of HCV genotype on assay performance.


Asunto(s)
Hepacivirus , Hepatitis C , Genotipo , Hepacivirus/genética , Humanos , ARN Viral , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Viral
9.
J Clin Virol ; 129: 104530, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32688329

RESUMEN

BACKGROUND: Accurate, rapid detection of HIV-1 RNA is critical for early diagnosis, treatment decision making, and long-term management of HIV-1 infection. OBJECTIVE: We evaluated the diagnostic performance of the Alinity m HIV-1 assay, which uses a dual target/dual probe design against highly conserved target regions of the HIV-1 genome and is run on the fully automated Alinity m platform. STUDY DESIGN: This was an international, multisite study that compared the diagnostic performance of the Alinity m HIV-1 assay to four commercially available HIV-1 assays routinely used in nine independent clinical laboratories. Alinity m HIV-1 assay precision, detectability, and reproducibility was compared across four study sites. RESULTS: The Alinity m HIV-1 assay produced comparable results to currently available HIV-1 assays (correlation coefficient >0.995), with an overall bias of -0.1 to 0.10 Log10 copies/mL. The Alinity m HIV-1 assay and its predecessor m2000 HIV-1 assay demonstrated comparable detection of 16 different HIV-1 subtypes (R2 = 0.956). A high level of agreement (>88 %) between all HIV-1 assays was seen near clinical decision points of 1.7 Log10 copies/mL (50 copies/mL) and 2.0 Log10 copies/mL (200 copies/mL). Alinity m HIV-1 assay precision was 0.08 and 0.21 Log10 copies/mL at VLs of 1000 and 50 copies/mL, respectively, with a high level of detectability (≥97 % hit rate) and reproducibility across sites. CONCLUSIONS: The Alinity m HIV-1 assay provides comparable diagnostic accuracy to current HIV-1 assays, and when run on the Alinity m system, has the capacity to shorten the time between diagnosis and treatment.


Asunto(s)
Infecciones por VIH , VIH-1 , VIH-1/genética , Humanos , ARN Viral , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Viral
11.
J Hepatol ; 65(3): 473-82, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27085252

RESUMEN

BACKGROUND & AIMS: The European Association for the Study of the Liver (EASL) guidelines recommend HCV RNA measurements at specific time points during sofosbuvir(SOF)-therapy. However, it remains unclear, how these results should be interpreted. We aimed to analyze whether on-treatment HCV RNA levels predict relapse comparing the CobasAmpliPrep/CobasTaqMan v2.0 (CAP/CTM) and Abbott RealTime HCV (ART) assays. METHODS: Samples were collected from 298 patients (HCV genotypes; GT1-5) at weeks (w) 0, 1, 2, 4, 8, 12, 16, 20 and 24 during SOF-based therapy at two university clinics and tested for HCV RNA level by CAP/CTM and ART. Patients were treated with SOF/ribavirin (RBV) 12/24 w (n=99), pegylated-interferon-alfa (PegIFN)/SOF/RBV 12 w (n=51), SOF/simeprevir (SMV)±RBV 12 w (n=69) or SOF/daclatasvir±RBV 12/24 w (n=79). RESULTS: HCV RNA levels during the first 4weeks of SOF/RBV therapy were significantly lower in GT3 patients who achieved SVR compared with those who relapsed. All GT3 patients with a week 2 result <45IU/ml by CAP/CTM achieved SVR but only 33% of those with ⩾45IU/ml (p=0.0003). Similar results were documented with ART and 60IU/ml as cut-off (SVR: 100% vs. 29%; p=0.0002). In contrast, HCV RNA levels during early treatment phases were not significantly related to relapse in patients treated with other SOF-based regimens. Residual HCV RNA was frequently detected by ART at later stages of therapy. However, SVR rates remained high in these patients. At the end of SOF/SMV±RBV therapy HCV RNA was detectable with ART in 20% of patients, of whom 92% achieved SVR. CONCLUSIONS: HCV RNA levels assessed at week 2 of SOF/RBV therapy can predict relapse in GT3-patients. Detectable HCV RNA results at later stages during SOF-based therapy may occur frequently with the more sensitive ART. However, this should not lead to treatment extension. LAY SUMMARY: We analyzed the predictive value of hepatitis C virus (HCV) RNA levels measured at different time points for treatment efficacy. We found that the level of HCV RNA measured at week 2 of antiviral therapy can be used to predict treatment success in patients with HCV genotype 3 infection treated with sofosbuvir and ribavirin but not in patients treated with other sofosbuvir-based regimens. Low level HCV RNA is frequently detected by the RealTime HCV assay during later stages of antiviral therapy. However, this is not associated with reoccurrence of HCV RNA after the end of treatment.


Asunto(s)
Hepatitis C , Antivirales , Genotipo , Hepacivirus , Humanos , Virus ARN , Simeprevir , Sofosbuvir
12.
J Clin Microbiol ; 54(2): 296-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26582834

RESUMEN

Hepatitis C virus (HCV) genotyping continues to be relevant for therapeutic strategies. Some samples are reported as genotype 1 (gt 1) without subtype by the Abbott RealTime HCV Genotype II (GT II) test. To characterize such samples further, the Abbott HCV Genotype Plus RUO (Plus) assay, which targets the core region for gt 1a, gt 1b, and gt 6 detection, was evaluated as a reflex test in reference to NS5B or 5'-untranslated region (UTR)/core region sequencing. Of 3,626 routine samples, results of gt 1 without subtype were received for 171 samples (4.7%), accounting for 11.5% of gt 1 specimens. The Plus assay and sequencing were applied to 98 of those samples. NS5B or 5'-UTR/core region sequencing was successful for 91/98 specimens (92.9%). Plus assay and sequencing results were concordant for 87.9% of specimens (80/91 samples). Sequencing confirmed Plus assay results for 82.6%, 85.7%, 100%, and 89.3% of gt 1a, gt 1b, gt 6, and non-gt 1a/1b/6 results, respectively. Notably, 12 gt 6 samples that had been identified previously as gt 1 without subtype were assigned correctly here; for 25/28 samples reported as "not detected" by the Plus assay, sequencing identified the samples as gt 1 with subtypes other than 1a/1b. The genetic variability of HCV continues to present challenges for the current genotyping platforms regardless of the applied methodology. Samples identified by the GT II assay as gt 1 without subtype can be further resolved and reliably characterized by the new Plus assay.


Asunto(s)
Genotipo , Hepacivirus/clasificación , Hepacivirus/genética , Hepatitis C/diagnóstico , Hepatitis C/virología , Juego de Reactivos para Diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Regiones no Traducidas 5' , Técnicas de Genotipaje , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Reproducibilidad de los Resultados , Análisis de Secuencia de ADN , Proteínas no Estructurales Virales/genética
13.
Nephrol Dial Transplant ; 18(11): 2382-6, 2003 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-14551370

RESUMEN

BACKGROUND: Current modalities of renal replacement therapy allow only a limited removal of larger, possibly toxic molecules, which accumulate in uraemia. Recently, a haemodiafilter has been made available with the new, high-flux, polyethersulfone-based membrane DIAPES HF800. We performed a study to compare DIAPES HF800 with two conventional high-flux membranes in on-line haemodiafiltration (HDF), with respect to the removal properties for the two marker proteins, beta(2)-microglobulin (beta(2)m, 11.8 kDa) and albumin (66.5 kDa). METHODS: In a prospective, controlled study 10 stable end-stage renal disease patients were randomly allocated to 30 sessions of post-dilutional on-line HDF with three types of steam-sterilized membranes: DIAPES HF800, polysulfone and polyamide. Blood flow rate was 250 ml/min and treatment time was 240 min. Pre-treatment beta(2)m and albumin plasma concentrations did not differ between the three groups. The concentration of the two proteins was determined before and after treatment in plasma as well as in the continuously collected haemodiafiltrate. RESULTS: Tolerance of all treatments was very good, without any side-effects for all filters. The mean plasma reduction rate of beta(2)m was 77 +/- 1% for DIAPES HF800 and polysulfone whereas it was 71 +/- 1% for polyamide (P < 0.05). The mean beta(2)m amount removed and found in the haemodiafiltrate per session was 230 +/- 14 mg for DIAPES HF800, 186 +/- 13 mg for polysulfone and 147 +/- 13 mg for polyamide (P < 0.05 between each pair of membranes). The same ranking was obtained for albumin removed and found in haemodiafiltrate per session for the three membranes: 5.7 +/- 0.4, 3.5 +/- 0.4 and 1.0 +/- 0.4 g, respectively. Although DIAPES HF800 showed the highest value for albumin in haemodiafiltrate the mean post-treatment plasma albumin was higher after the treatment with DIAPES HF800 compared with the other membranes (P < 0.05). CONCLUSIONS: On-line HDF has shown to achieve plasma reduction rates for beta(2)m of up to 77% for the DIAPES HF800 membrane and for polysulfone. The amounts of beta(2)m and albumin in haemodiafiltrate were much higher for DIAPES HF800 than for the other two membranes indicating a greater permeability for molecules up to a molecular weight of 66.5 kDa. This could, at least theoretically, offer the advantage also to remove uraemic toxins in the molecular weight range of albumin or of albumin-bound toxins. The future must show whether this will counterbalance the loss of albumin.


Asunto(s)
Hemodiafiltración/instrumentación , Membranas Artificiales , Polímeros , Albúmina Sérica/análisis , Sulfonas , Microglobulina beta-2/sangre , Estudios Cruzados , Femenino , Humanos , Masculino , Sistemas en Línea , Estudios Prospectivos , Uremia/sangre , Uremia/terapia