Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 8 de 8
1.
Indian J Radiol Imaging ; 34(2): 309-323, 2024 Apr.
Article En | MEDLINE | ID: mdl-38549900

The new 2023 update of the International Federation of Gynecology and Obstetrics (FIGO) staging system for endometrial cancer incorporates the advances made in the understanding of the pathology and molecular classifications into the staging system. While the new staging system aids in precision medicine and may lead to better documentation of prognostic risk categories of endometrial cancer, it is complex and calls for an integrated approach and better communication between multiple disciplines involved in the management of endometrial cancer. In this review article, we address how the referral patterns to imaging services might change considering the updated staging system for endometrial cancer. We also discuss the practical aspects and nuances involved in the radiology service delivery and reporting practices as we adopt the new FIGO staging system for managing endometrial cancer patients.

2.
Abdom Radiol (NY) ; 48(6): 2122-2130, 2023 06.
Article En | MEDLINE | ID: mdl-36988699

PURPOSE: To evaluate a MRI scoring system predicting haemorrhagic necrosis in adnexal torsion with intraoperative and/or histopathological correlation using an abbreviated and optimized MRI protocol. METHODS: This retrospective observational study includes patients with adnexal torsion who underwent Magnetic Resonance Imaging(MRI) and surgery. T2 sequences were evaluated by three observers of varying experience for following findings: Hypo-intensity of ovarian stroma, around the follicle, cyst wall or ovarian capsule and the twisted pedicle. Hypo-intensities in the above and a thick cyst wall were considered as predictors of necrosis. A scoring system was created based on the number of positive findings. MRI was correlated with intraoperative and histopathological findings. Lesions showing haemorrhagic necrosis were considered true positives. RESULTS: 43 women with torsion were included. 74.4% were secondary to a lead point and 25.4% were without one. Hypointensity score of 2 or more had the highest diagnostic accuracy and inter-reader agreement in predicting necrosis (R1-sensitivity: 92%, specificity: 89%, positive predictive value (PPV): 92% and negative predictive value (NPV): 89%, R2-sensitivity: 92%, specificity: 94%, PPV: 96% and NPV: 90% and R3-sensitivity: 92%, specificity: 83%, PPV: 89% and NPV: 89%). CONCLUSION: In patients with suspected adnexal torsion, optimized MRI using T2 weighted sequences will serve as a rapid and effective single imaging modality for diagnosing adnexal torsion and accurately predicting necrosis thereby triaging the patients for appropriate management.


Adnexal Diseases , Cysts , Ovarian Diseases , Humans , Female , Ovarian Torsion , Adnexal Diseases/diagnostic imaging , Adnexal Diseases/pathology , Torsion Abnormality/diagnostic imaging , Ovarian Diseases/diagnostic imaging , Magnetic Resonance Imaging/methods , Retrospective Studies , Necrosis/diagnostic imaging , Infarction , Observational Studies as Topic
3.
Indian J Radiol Imaging ; 32(4): 582-590, 2022 Dec.
Article En | MEDLINE | ID: mdl-36451948

Pseudoangiomatous stromal hyperplasia (PASH) is a benign mesenchymal tumor-like lesion of the breast. It is commonly seen as incidental background changes of the intralobular stroma in biopsy specimens performed for other breast lesions. Less frequently, it presents as a nodular form that has a benign morphology on imaging, mimicking fibroadenoma or as a diffuse form causing progressive massive gigantomastia. Diagnosis is established by biopsy. Knowledge of the imaging appearance of PASH not only facilitates proper assessment of radiopathological correlation but also helps in deciding further management of these lesions. Occasionally, nodular PASH may have a suspicious appearance on imaging wherein excision biopsy is indicated to exclude a coexisting carcinoma.

4.
Pol J Radiol ; 86: e601-e607, 2021.
Article En | MEDLINE | ID: mdl-34876941

PURPOSE: Our study aimed to compare the sensitivity of T2 relaxometry and positron emission tomography - computed tomography (PET/CT) in patients with a history suggestive of mesial temporal lobe epilepsy using video electroencephalography (EEG) as the reference standard. MATERIAL AND METHODS: In our study, 35 patients with a history suggestive of mesial temporal lobe epilepsy were subjected to conventional magnetic resonance imaging (MRI), T2 relaxometry, and PET/CT. The results of each of the studies were compared with video EEG findings. Analyses were performed by using statistical software (SPSS version 20.0 for windows), and the sensitivity of conventional MRI, T2 relaxometry, and PET/CT were calculated. RESULTS: The sensitivity of qualitative MRI (atrophy and T2 hyperintensity), quantitative MRI (T2 relaxometry), and PET/CT in lateralizing the seizure focus were 68.6% (n = 24), 85.7% (n = 30), and 88.6% (n = 31), respectively. CONCLUSIONS: The sensitivity of MRI in lateralization and localization of seizure focus in temporal lobe epilepsy can be increased by adding the quantitative parameter (T2 relaxometry) with the conventional sequences. T2 Relaxometry is comparable to PET/CT for localization and lateralization of seizure focus and is a useful tool in the workup of TLE patients.

5.
Pol J Radiol ; 86: e208-e216, 2021.
Article En | MEDLINE | ID: mdl-34093917

PURPOSE: The aim of our study was to compare single-energy (SECT) and dual-energy (DECT) abdominal computed tomography (CT) examinations in matched patient cohorts regarding the differences in effective radiation dose (ERD) and image quality performed in a third-generation dual-source computed tomography (DSCT) scanner. MATERIAL AND METHODS: Our study included 100 patients, who were divided randomly into 2 groups. The patients included in Group A were scanned by SECT, and Group B members were scanned by DECT. Volume CT dose index (CTDIvol), dose length product (DLP), and ERD for venous phase acquisition were recorded in each patient and were normalised for 40 cm. Analyses were performed by using statistical software (SPSS version 20.0 for windows), and Bonferroni correction for multiple comparisons was applied for p-values and confidence intervals. RESULTS: Average ERD based on DLP values normalised for 40 cm acquisition were obtained for both Group A and Group B. The mean ERD for Group A was 11.89 mSv, and for group B it was 6.87 mSv. There was a significant difference in these values between Group A and Group B as shown by a p-value of < 0.001. On subjective and objective analysis, there was no statistically significant difference in image quality between the 2 groups. CONCLUSIONS: The protocols in third-generation DSCT using dual-energy mode resulted in significant reductions in the effective radiation dose (by approximately 58%) compared to SECT in routine abdominal examination in matched cohorts. Therefore, the quantitative imaging potential of DECT can be utilised in needed patients with decreased radiation dose in third-generation DSCT.

6.
Cureus ; 13(3): e14147, 2021 Mar 27.
Article En | MEDLINE | ID: mdl-33927949

PURPOSE:  To prospectively estimate the reliability of B-mode ultrasonography and sonoelastography in differentiating benign and malignant cervical lymph nodes with cytological findings as to the reference standard. MATERIALS AND METHODS: A total of 50 patients referred for sonography for enlarged cervical lymph nodes were included in the study. They were subjected initially to B-mode ultrasonography and sonoelastography and later underwent fine-needle aspiration cytology (FNAC) in the same sitting. Sensitivity, specificity, and accuracy were compared. RESULTS: Out of 50 cases, 33 were males, and 17 were females. On B-mode ultrasonography, 15 enlarged cervical lymph nodes were benign-looking and 35 were malignant-looking. When studied on elastography, 12 were benign-looking and 38 showed features of malignancy. However, when studied histopathologically, 18 were benign and 32 were malignant. The sensitivity, specificity, and diagnostic accuracy were compared, and the results were better in sonoelastography than B-mode ultrasonography. When both B-mode and sonoelastography were combined, an increase in the sensitivity for differentiation was achieved. However, a decrease in specificity was noted when both modalities were combined in our study, probably due to a significant number of patients with tuberculous cervical lymphadenopathy. CONCLUSION: In countries like India, where granulomatous infection like tuberculosis is prevalent, the combination of sonoelastography with B-mode ultrasonography has decreased specificity in the differentiation of benign and malignant cervical lymph nodes, and histopathology is always needed for the final confirmation of diagnosis. The decreased specificity on elastography is attributed to simultaneous coexisting inflammation and fibrosis in chronic granulomatous lymphadenopathy.

7.
Cureus ; 12(10): e10849, 2020 Oct 08.
Article En | MEDLINE | ID: mdl-33178504

Cystic renal lesions are commonly seen on a daily basis in abdominal imaging. Even though most cystic renal lesions are benign simple cysts, complex and multifocal cystic renal diseases are also common with a vast number of differentials. One of the rare mimickers of this condition is renal lymphangiectasia, and the disease can be diagnosed if radiologists are aware of the imaging findings, and this can help the physician to offer the appropriate treatment. We report a case series of five cases in our hospital and also review the literature on renal lymphangiectasia, including its pathophysiology, clinical presentation, imaging appearances, complications, treatment, and differentials.

...