Nuklearmedizin ; 63(3): 199-206, 2024 Jun.
Article En | MEDLINE | ID: mdl-38580313

AIM: This study aimed to assess the impact of 68Ga-PSMA PET/CT on radiation treatment (RT) planning in prostate cancer patients with salvage (sRT) or definitive (dRT) radiotherapy. METHODS: 38 patients (27 sRT, median PSA 0.79 ng/ml (range 0.06-12.1); 11 dRT, median PSA 4.35 ng/ml (range 1.55-55.5) underwent 68Ga-PSMA PET/CT before RT. Influence of 68Ga-PSMA PET/CT on the extent of planning target volume (PTV) and addition of PET-based boosts were assessed. Median follow up was 12 months (range 3-24). RESULTS: 68Ga-PSMA PET/CT showed positive findings in 23/38 patients (8/23: local recurrence (LR), 11/23: nodal metastasis, 1/23: LR and nodal, 2/23: solitary bone metastasis, 1/23: oligometastatic nodal/ bone metastases). In sRT primary PTV was changed in 16/27 patients extending the PTV to the lymphatic drainage (10/16), PSMA-positive LR (3/16), bone metastases (2/16) and both nodal/bone metastases (1/16). PET-based increase of primary PTV was 116%. PET-based boosts were administered in 19/27 patients (8/19: local, 10/19: nodal, 1/19: both), median boost volume was 31.3 cm3 (range 17.2-80.2) (local) and 19.7 cm3 (range 3.0-109.3) (nodal). PTV was changed in 1/11 (9%) of dRT patients (extension of primary PTV to the lymphatic drainage (RT volume of 644.5 cm3), additional nodal boost (volume of 2.7 cm3, 23.1 Gy)). All patients showed biochemical response (mean PSA decrease 88.8 +/- 14.0%). Nadir PSA was reached 10 months (range 1-17) after end of RT (median 0.07 ng/ml, range 0.002-3.96). Within a median 12 months follow-up (range 3-22/8-24 in sRT/dRT), median PSA was 0.05 ng/ml (range 0.002-8.5) (sRT) and 0.26 ng/ml (range 0.02-2.68) (dRT). CONCLUSIONS: 68Ga-PSMA PET/CT influenced sRT planning in almost 63% and dRT in 9% of patients by change of PTV and additional boosts.


Edetic Acid , Gallium Isotopes , Gallium Radioisotopes , Oligopeptides , Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Radiotherapy Planning, Computer-Assisted , Humans , Male , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Aged , Radiotherapy Planning, Computer-Assisted/methods , Middle Aged , Edetic Acid/analogs & derivatives , Aged, 80 and over , Radiopharmaceuticals/therapeutic use , Treatment Outcome
2.
Biomimetics (Basel) ; 8(2)2023 May 31.
Article En | MEDLINE | ID: mdl-37366825

The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.

3.
Sci Rep ; 12(1): 10909, 2022 06 28.
Article En | MEDLINE | ID: mdl-35764679

This study aims to identify key anatomic features that govern the individual variability of lung doses from breast-cancer radiotherapy. 3D conformal, intensity-modulated and hybrid techniques with 50.4 Gy whole-breast dose were planned for 128 patients. From their CT images, 17 anatomic measures were assessed and tested as predictors for lung dose-volume characteristics. Tangential techniques yielded mean ipsilateral lung doses in the range of 3-11 Gy. This inter-patient variability was explained to almost 40% by central lung distance, and to almost 60% if this measure was complemented by midplane lung width and maximum heart distance. Also the variability in further dose-volume metrics such as volume fractions receiving 5, 20 or 40 Gy could be largely explained by the anatomy. Multi-field intensity-modulated radiotherapy reduced high-exposed lung volumes, but resulted in higher mean ipsilateral lung doses and larger low-dose burden. Contralateral lung doses ranged from 0.3 to 1 Gy. The results highlight that there are large differences in lung doses among breast-cancer patients. Most of this inter-individual variability can be explained by a few anatomic features. The results will be implemented in a dedicated software tool to provide personalized estimates of long-term health risks related to breast-cancer radiotherapy. The results may also be used to identify favourable as well as problematic anatomies, and serve as a quick quantitative benchmark for individual treatment plans.


Breast Neoplasms , Radiotherapy, Conformal , Breast/diagnostic imaging , Breast Neoplasms/radiotherapy , Female , Humans , Lung/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods
4.
Radiat Oncol ; 16(1): 241, 2021 Dec 20.
Article En | MEDLINE | ID: mdl-34930360

PURPOSE: Cardiac effects after breast cancer radiation therapy potentially affect more patients as survival improves. The heart's heterogeneous radiation exposure and composition of functional structures call for establishing individual relationships between structure dose and specific late effects. However, valid dosimetry requires reliable contouring which is challenging for small volumes based on older, lower-quality computed tomography imaging. We developed a heart atlas for robust heart contouring in retrospective epidemiologic studies. METHODS AND MATERIALS: The atlas defined the complete heart and geometric surrogate volumes for six cardiac structures: aortic valve, pulmonary valve, all deeper structures combined, myocardium, left anterior myocardium, and right anterior myocardium. We collected treatment planning records from 16 patients from 4 hospitals including dose calculations for 3D conformal tangential field radiation therapy for left-sided breast cancer. Six observers each contoured all patients. We assessed spatial contouring agreement and corresponding dosimetric variability. RESULTS: Contouring agreement for the complete heart was high with a mean Jaccard similarity coefficient (JSC) of 89%, a volume coefficient of variation (CV) of 5.2%, and a mean dose CV of 4.2%. The left (right) anterior myocardium had acceptable agreement with 63% (58%) JSC, 9.8% (11.5%) volume CV, and 11.9% (8.0%) mean dose CV. Dosimetric agreement for the deep structures and aortic valve was good despite higher spatial variation. Low spatial agreement for the pulmonary valve translated to poor dosimetric agreement. CONCLUSIONS: For the purpose of retrospective dosimetry based on older imaging, geometric surrogate volumes for cardiac organs at risk can yield better contouring agreement than anatomical definitions, but retain limitations for small structures like the pulmonary valve.


Breast Neoplasms/radiotherapy , Heart/radiation effects , Dose-Response Relationship, Radiation , Evaluation Studies as Topic , Female , Humans , Observer Variation , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies , Tomography, X-Ray Computed
5.
Radiat Prot Dosimetry ; 186(2-3): 381-385, 2019 Dec 31.
Article En | MEDLINE | ID: mdl-31711194

Breast cancer radiotherapy may in the long term lead to radiation-induced secondary cancer or heart disease. These health risks hugely vary among patients, partially due to anatomy-driven differences in doses deposited to the heart, ipsilateral lung and contralateral breast. We identify four anatomic features that largely cover these dosimetric variations to enable personalized risk estimates. For three exemplary, very different risk scenarios, the given parameter set reproduces 63-74% of the individual risk variability for left-sided breast cancer patients. These anatomic features will be used in the PASSOS software to support decision processes in breast-cancer therapy.


Breast Neoplasms/radiotherapy , Breast/pathology , Heart/anatomy & histology , Lung/pathology , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/adverse effects , Breast/radiation effects , Female , Heart/radiation effects , Humans , Image Processing, Computer-Assisted/methods , Lung/radiation effects , Neoplasms, Radiation-Induced/etiology , Neoplasms, Radiation-Induced/pathology , Radiation Injuries/etiology , Radiation Injuries/pathology , Radiotherapy Dosage , Tomography, X-Ray Computed/methods
6.
Radiother Oncol ; 131: 186-191, 2019 02.
Article En | MEDLINE | ID: mdl-30241788

PURPOSE: To provide personalized estimates of doses to contralateral breast (CB) from breast-cancer radiotherapy. METHODS: Whole-breast irradiations using 3D conformal, intensity-modulated and hybrid techniques with 50.4 Gy prescribed dose were planned for 128 breast-cancer patients. From their CT images, 17 anatomic measures were assessed and tested by model fitting as predictors for CB dose-volume characteristics. RESULTS: Multi-field intensity-modulated radiotherapy (IMRT) yielded mean CB doses of 0.8-7.1 Gy, with no correlation to the studied anatomic parameters. Tangential whole-breast irradiation led to much lower mean CB doses, 0.2-1.6 Gy. About 60% of this inter-patient variability was explained by individual variations in a single anatomic measure, the minimum breast distance (MBD), defined as the CB distance from the tangent to the treated breast. Per 1 cm increase in MBD, the mean CB dose decreased by 10-15%. As an alternative to MBD, dose estimates could be based on the breast-to-breast distance, which is highly correlated with MBD. CONCLUSION: The results enable personalized assessment of CB doses from tangential whole-breast irradiation, based only on parameters assessable from CT data. This may help support clinical decision-making processes as well as analyse retrospective studies on CB risks.


Breast Neoplasms/radiotherapy , Breast/anatomy & histology , Breast/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Female , Humans , Neoplasm Staging , Precision Medicine , Radiotherapy Dosage , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods , Retrospective Studies
7.
Radiat Prot Dosimetry ; 183(1-2): 255-258, 2019 May 01.
Article En | MEDLINE | ID: mdl-30535311

With improved cure rates and prolonged patient survival after breast-cancer radiotherapy, radiation-induced second cancers and heart diseases become increasingly important. The heart, lungs and contralateral breast are the most critical organs for these long-term effects. Doses to these organs and hence the risks differ between radiotherapy techniques and especially among patients. To address this variability, treatment plans were generated for 128 early-stage breast-cancer patients using intensity-modulated, 3D-conformal and hybrid radiotherapy. Twenty dedicated anatomic measures were assessed from CT data, such as the width and thickness of the treated breast or its distance from the heart. Their impact on doses to critical nearby organs was analysed. The majority of inter-patient variability can be covered with a few anatomic parameters. Patients can thus be stratified according to long-term risks already before treatment planning, and guidance can be provided towards a personalised selection of technique associated with the lowest risk.


Breast Neoplasms/radiotherapy , Breast/radiation effects , Heart/radiation effects , Lung/radiation effects , Neoplasms, Radiation-Induced/etiology , Radiation Injuries/etiology , Radiotherapy Planning, Computer-Assisted/methods , Adult , Algorithms , Breast Neoplasms/pathology , Female , Humans , Neoplasm Staging , Organs at Risk , Radiotherapy Dosage , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Tomography, X-Ray Computed
8.
Radiat Prot Dosimetry ; 183(1-2): 259-263, 2019 May 01.
Article En | MEDLINE | ID: mdl-30520982

Breast-cancer radiotherapy reduces the recurrence rates and improves patient survival. However, it also increases the incidence of second cancers and of heart disease. These radiation-induced long-term health risks become increasingly important with improved cure rates and prolonged patient survival. Radiation doses to nearby as well as distant organs strongly vary between different irradiation techniques and among individual patients. To provide personalized lifetime risk estimates, the German national project PASSOS combines individual anatomy, dosimetric estimates, organ-specific low- and high-dose risk models and personal risk factors such as smoking. A dedicated software tool is under development to assist clinical decision-making processes.


Breast Neoplasms/radiotherapy , Neoplasms, Radiation-Induced/etiology , Neoplasms, Second Primary/etiology , Radiation Injuries/etiology , Dose-Response Relationship, Radiation , Female , Germany , Heart/radiation effects , Humans , Organ Specificity , Organs at Risk , Radiometry , Radiotherapy Dosage , Risk Assessment , Risk Factors , Software
...