1.
J Neural Eng ; 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39321851

RESUMEN

OBJECTIVE: The phase of the electroencephalographic (EEG) signal predicts performance in motor, somatosensory, and cognitive functions. Studies suggest that brain phase resets align neural oscillations with external stimuli, or couple oscillations across frequency bands and brain regions. Transcranial Magnetic Stimulation (TMS) can cause phase resets noninvasively in the cortex, thus providing the potential to control phase-sensitive cognitive functions. However, the relationship between TMS parameters and phase resetting is not fully understood. This is especially true of TMS intensity, which may be crucial to enabling precise control over the amount of phase resetting that is induced. Additionally, TMS phase resetting may interact with the instantaneous phase of the brain. Understanding these relationships is crucial to the development of more powerful and controllable stimulation protocols. Approach: To test these relationships, we conducted a TMS-EEG study. We applied single-pulse TMS at varying degrees of stimulation intensity to the motor area in an open loop. Offline, we used an autoregressive algorithm to estimate the phase of the intrinsic µ-Alpha rhythm of the motor cortex at the moment each TMS pulse was delivered. Main results: We identified post-stimulation epochs where µ-Alpha phase resetting and N100 amplitude depend parametrically on TMS intensity and are significant versus peripheral auditory sham stimulation. We observed µ-Alpha phase inversion after stimulations near peaks but not troughs in the endogenous µ-Alpha rhythm. Significance: These data suggest that low-intensity TMS primarily resets existing oscillations, while at higher intensities TMS may activate previously silent neurons, but only when endogenous oscillations are near the peak phase. These data can guide future studies that seek to induce phase resetting, and point to a way to manipulate the phase resetting effect of TMS by varying only the timing of the pulse with respect to ongoing brain activity.

2.
Cortex ; 172: 141-158, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38330778

RESUMEN

BACKGROUND: Cognitive control processes, including those involving frontoparietal networks, are highly variable between individuals, posing challenges to basic and clinical sciences. While distinct frontoparietal networks have been associated with specific cognitive control functions such as switching, inhibition, and working memory updating functions, there have been few basic tests of the role of these networks at the individual level. METHODS: To examine the role of cognitive control at the individual level, we conducted a within-subject excitatory transcranial magnetic stimulation (TMS) study in 19 healthy individuals that targeted intrinsic ("resting") frontoparietal networks. Person-specific intrinsic networks were identified with resting state functional magnetic resonance imaging scans to determine TMS targets. The participants performed three cognitive control tasks: an adapted Navon figure-ground task (requiring set switching), n-back (working memory), and Stroop color-word (inhibition). OBJECTIVE: Hypothesis: We predicted that stimulating a network associated with externally oriented control [the "FPCN-B" (fronto-parietal control network)] would improve performance on the set switching and working memory task relative to a network associated with attention (the Dorsal Attention Network, DAN) and cranial vertex in a full within-subjects crossover design. RESULTS: We found that set switching performance was enhanced by FPCN-B stimulation along with some evidence of enhancement in the higher-demand n-back conditions. CONCLUSION: Higher task demands or proactive control might be a distinguishing role of the FPCN-B, and personalized intrinsic network targeting is feasible in TMS designs.


Asunto(s)
Memoria a Corto Plazo , Estimulación Magnética Transcraneal , Humanos , Memoria a Corto Plazo/fisiología , Imagen por Resonancia Magnética , Inhibición Psicológica , Cognición/fisiología , Encéfalo/fisiología
3.
J Neural Eng ; 21(1)2024 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-38081060

RESUMEN

Objective.To evaluate the signal quality of dry MXene-based electrode arrays (also termed 'MXtrodes') for electroencephalographic (EEG) recordings where gelled Ag/AgCl electrodes are a standard.Approach.We placed 4 × 4 MXtrode arrays and gelled Ag/AgCl electrodes on different scalp locations. The scalp was cleaned with alcohol and rewetted with saline before application. We recorded from both electrode types simultaneously while participants performed a vigilance task.Main results.The root mean squared amplitude of MXtrodes was slightly higher than that of Ag/AgCl electrodes (.24-1.94 uV). Most MXtrode pairs had slightly lower broadband spectral coherence (.05 to .1 dB) and Delta- and Theta-band timeseries correlation (.05 to .1 units) compared to the Ag/AgCl pair (p< .001). However, the magnitude of correlation and coherence was high across both electrode types. Beta-band timeseries correlation and spectral coherence were higher between neighboring MXtrodes in the array (.81 to .84 units) than between any other pair (.70 to .75 units). This result suggests the close spacing of the nearest MXtrodes (3 mm) more densely sampled high spatial-frequency topographies. Event-related potentials were more similar between MXtrodes (ρ⩾ .95) than equally spaced Ag/AgCl electrodes (ρ⩽ .77,p< .001). Dry MXtrode impedance (x̄= 5.15 KΩ cm2) was higher and more variable than gelled Ag/AgCl electrodes (x̄= 1.21 KΩ cm2,p< .001). EEG was also recorded on the scalp across diverse hair types.Significance.Dry MXene-based electrodes record EEG at a quality comparable to conventional gelled Ag/AgCl while requiring minimal scalp preparation and no gel. MXtrodes can record independent signals at a spatial density four times higher than conventional electrodes, including through hair, thus opening novel opportunities for research and clinical applications that could benefit from dry and higher-density configurations.


Asunto(s)
Benchmarking , Electroencefalografía , Nitritos , Elementos de Transición , Humanos , Electroencefalografía/métodos , Impedancia Eléctrica , Electrodos , Etanol
4.
eNeuro ; 10(9)2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37558464

RESUMEN

EEG phase is increasingly used in cognitive neuroscience, brain-computer interfaces, and closed-loop stimulation devices. However, it is unknown how accurate EEG phase prediction is across cognitive states. We determined the EEG phase prediction accuracy of parieto-occipital alpha waves across rest and task states in 484 participants over 11 public datasets. We were able to track EEG phase accurately across various cognitive conditions and datasets, especially during periods of high instantaneous alpha power and signal-to-noise ratio (SNR). Although resting states generally have higher accuracies than task states, absolute accuracy differences were small, with most of these differences attributable to EEG power and SNR. These results suggest that experiments and technologies using EEG phase should focus more on minimizing external noise and waiting for periods of high power rather than inducing a particular cognitive state.


Asunto(s)
Electroencefalografía , Descanso , Humanos , Electroencefalografía/métodos , Relación Señal-Ruido , Descanso/fisiología , Cognición , Encéfalo/fisiología
5.
Front Behav Neurosci ; 17: 1176865, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37292166

RESUMEN

Recent studies suggest that attention is rhythmic. Whether that rhythmicity can be explained by the phase of ongoing neural oscillations, however, is still debated. We contemplate that a step toward untangling the relationship between attention and phase stems from employing simple behavioral tasks that isolate attention from other cognitive functions (perception/decision-making) and by localized monitoring of neural activity with high spatiotemporal resolution over the brain regions associated with the attentional network. In this study, we investigated whether the phase of electroencephalography (EEG) oscillations predicts alerting attention. We isolated the alerting mechanism of attention using the Psychomotor Vigilance Task, which does not involve a perceptual component, and collected high resolution EEG using novel high-density dry EEG arrays at the frontal region of the scalp. We identified that alerting attention alone is sufficient to induce a phase-dependent modulation of behavior at EEG frequencies of 3, 6, and 8 Hz throughout the frontal region, and we quantified the phase that predicts the high and low attention states in our cohort. Our findings disambiguate the relationship between EEG phase and alerting attention.

6.
Ophthalmol Retina ; 7(7): 573-585, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36906177

RESUMEN

PURPOSE: To evaluate the safety and efficacy of repeat injections of Brimonidine Drug Delivery System (Brimo DDS) Generation 2 (Gen 2) containing 400-µg brimonidine in patients with geographic atrophy (GA) secondary to age-related macular degeneration (AMD). DESIGN: A phase IIb, randomized, multicenter, double-masked, sham-controlled, 30-month study (BEACON). PARTICIPANTS: Patients diagnosed with GA secondary to AMD and multifocal lesions with total area of > 1.25 mm2 and ≤ 18 mm2 in the study eye. METHODS: Enrolled patients were randomized to treatment with intravitreal injections of 400-µg Brimo DDS (n = 154) or sham procedure (n = 156) in the study eye every 3 months from day 1 to month 21. MAIN OUTCOME MEASURES: The primary efficacy endpoint was GA lesion area change from baseline in the study eye, assessed with fundus autofluorescence imaging, at month 24. RESULTS: The study was terminated early, at the time of the planned interim analysis, because of a slow GA progression rate (∼ 1.6 mm2/year) in the enrolled population. Least squares mean (standard error) GA area change from baseline at month 24 (primary endpoint) was 3.24 (0.13) mm2 with Brimo DDS (n = 84) versus 3.48 (0.13) mm2 with sham (n = 91), a reduction of 0.25 mm2 (7%) with Brimo DDS compared with sham (P = 0.150). At month 30, GA area change from baseline was 4.09 (0.15) mm2 with Brimo DDS (n = 49) versus 4.52 (0.15) mm2 with sham (n = 46), a reduction of 0.43 mm2 (10%) with Brimo DDS compared with sham (P = 0.033). Exploratory analysis showed numerically smaller loss over time in retinal sensitivity assessed with scotopic microperimetry with Brimo DDS than with sham (P = 0.053 at month 24). Treatment-related adverse events were usually related to the injection procedure. No implant accumulation was observed. CONCLUSIONS: Multiple intravitreal administrations of Brimo DDS (Gen 2) were well tolerated. The primary efficacy endpoint at 24 months was not met, but there was a numeric trend for reduction in GA progression at 24 months compared with sham treatment. The study was terminated early because of the lower-than-expected GA progression rate in the sham/control group. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosures may be found after the references.


Asunto(s)
Atrofia Geográfica , Degeneración Macular , Humanos , Atrofia Geográfica/diagnóstico , Atrofia Geográfica/tratamiento farmacológico , Atrofia Geográfica/etiología , Degeneración Macular/complicaciones , Degeneración Macular/diagnóstico , Degeneración Macular/tratamiento farmacológico , Retina , Sistemas de Liberación de Medicamentos/efectos adversos , Inyecciones Intravítreas
7.
Nanoscale Horiz ; 7(1): 63-76, 2021 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-34792059

RESUMEN

This work addresses the issue of dark states formation in QDs by cooperative excitonic and intrinsic defect-assisted radiative transitions. Here we refer to the observed blinking as D-type to distinguish it from purely excitonic types. It is shown experimentally that defect-assisted radiative relaxations in a single I-III-VI QD result in atypical blinking characteristics that cannot be explained on the basis of charged exciton models. In addition to the excitonic channel, it has been proposed that defect-assisted kinetics can also form blinking patterns. Two conditions for the formation of dark states have been identified which are related to correlation and competition when considering photons emitted from bright defects. Two transition schemes have therefore been proposed. The first transition scheme includes time-correlated trapping of more than one electron at a single trap centre. This is used to simulate variations in the defect's charge state and switching between radiative/nonradiative transitions. The latter scheme, on the other hand, involves uncorrelated trapping and radiative relaxations from two different types of defects (competition). Both schemes are seen to play an equal role in radiative processes in I-III-VI QDs. Considered together, the proposed models can reflect the experimental data with very good accuracy, providing a better understanding of the underlying physics. An important implication of these schemes is that dark states formation doesn't have to be limited to mechanisms that involve charged excitons, and it may also be observed for independent defect assisted kinetics. This is especially valid for highly defected or multinary QDs.


Asunto(s)
Puntos Cuánticos , Parpadeo , Fotones
8.
Ophthalmology ; 127(10): 1345-1359, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32344075

RESUMEN

PURPOSE: To evaluate features and outcomes of eyes with retinal vasculitis and intraocular inflammation (IOI) after intravitreal injection (IVI) of brolucizumab 6 mg/0.05 ml for treatment of neovascular age-related macular degeneration. DESIGN: Retrospective case series. PARTICIPANTS: Fifteen eyes from 12 patients identified from 10 United States centers. METHODS: Review of patient demographics, ophthalmologic examination results, and retinal imaging findings. MAIN OUTCOME MEASURES: Baseline and follow-up visual acuity (VA), prior anti-vascular endothelial growth factor (VEGF) injections, clinical presentation, retinal findings, fluorescein angiography results, and treatment strategies. RESULTS: The number of previous anti-VEGF IVIs ranged between 2 and 80 in the affected eye before switching to brolucizumab. Retinal vasculitis and IOI were diagnosed at a mean of 30 days after brolucizumab IVI. Mean VA before brolucizumab IVI was 0.426 logarithm of the minimum angle of resolution (logMAR; Snellen equivalent, 20/53) and VA at diagnosis of retinal vasculitis was 0.981 logMAR (Snellen equivalent, 20/191; range, 20/25-20/1600; P = 0.008). All affected eyes showed IOI with variable combinations of focal or elongated segmental sheathing and discontinuity of small and large retinal arteries, sclerotic arteries, regions of vascular nonperfusion, cotton-wool spots, Kyrieleis plaques, irregular venous caliber with dilated and sclerotic segments, perivenular hemorrhages, and foci of phlebitis. Fluorescein angiography revealed delayed retinal arterial filling, retinal vascular nonperfusion, and variable dye leakage from affected vessels and the optic nerve. Systemic evaluation for embolic causes was unrevealing in 2 patients, and 3 patients showed negative laboratory assessment for uveitis. Treatment consisted of various combinations of corticosteroids (systemic, intravitreal, and topical), and 2 eyes underwent vitrectomy without improvement in vision. After a mean follow-up of 25 days, mean VA was 0.833 logMAR (Snellen equivalent, 20/136), which was reduced compared with baseline (P = 0.033). CONCLUSIONS: Retinal vasculitis and IOI after brolucizumab IVI are characterized by variable occlusion of large or small retinal arteries, or both, and perivenular abnormalities. It may span from peripheral vasculitis to occlusion of large retinal arteries around the optic nerve or macula with severe vision loss. A high index of suspicion is required because vitreous cells may obscure visualization of retinal details.


Asunto(s)
Anticuerpos Monoclonales Humanizados/efectos adversos , Vasculitis Retiniana/inducido químicamente , Uveítis/inducido químicamente , Agudeza Visual , Anciano , Anciano de 80 o más Años , Anticuerpos Monoclonales Humanizados/administración & dosificación , Femenino , Angiografía con Fluoresceína , Estudios de Seguimiento , Fondo de Ojo , Humanos , Inyecciones Intravítreas , Mácula Lútea/patología , Masculino , Pronóstico , Vasculitis Retiniana/diagnóstico , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Uveítis/diagnóstico
9.
J Orthop Trauma ; 32(11): e445-e450, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30086040

RESUMEN

OBJECTIVES: To determine if mean ultimate strength or failure mechanism differed between comminuted olecranon fractures created at the proximal 25% or 50% of the trochlear notch and fixed with precontoured posterior locking plates (PLPs). METHODS: Comminuted osteotomies were created in 10 matched pairs of cadaveric upper extremities at either the proximal 25% or 50% of the trochlear notch after quantitative computed tomography scans were performed to evaluate bone mineral density. Variable-angle olecranon PLPs were fixed to the specimens. The triceps tendon of each specimen was loaded cyclically and then to failure. Comparison of mean force at failure (displacement >2 mm) was performed using the 2-tailed t test. RESULTS: There were no significant differences in specimen bone mineral density within matched pairs. Nineteen specimens failed by olecranon bisection fracture in the sagittal plane. Specimens in the 25% osteotomy group failed at lower ultimate forces of 808 N (SD ± 474 N) versus 1058 N (SD ± 480 N) in the 50% osteotomy group (P = 0.044). CONCLUSIONS: The ultimate strength of comminuted olecranon fracture fixation with a PLP decreases significantly if the fracture is proximal to the midpoint of the trochlear notch. Fractures proximal to the midpoint of the trochlear notch may benefit from supplemental fixation or suture augmentation to prevent failure, particularly at force ranges higher than those experienced during active elbow range of motion.


Asunto(s)
Placas Óseas , Articulación del Codo/cirugía , Fijación Interna de Fracturas/instrumentación , Fracturas Conminutas/cirugía , Olécranon/cirugía , Tomografía Computarizada por Rayos X/métodos , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Fijación Interna de Fracturas/métodos , Fracturas Conminutas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Muestreo
10.
Front Physiol ; 8: 732, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29081749

RESUMEN

The systemic circulation offers larger resistance to the blood flow than the pulmonary system. Consequently, the left ventricle (LV) must pump blood with more force than the right ventricle (RV). The question arises whether the stronger pumping action of the LV is due to a more efficient action of left ventricular myosin, or whether it is due to the morphological differences between ventricles. Such a question cannot be answered by studying the entire ventricles or myocytes because any observed differences would be wiped out by averaging the information obtained from trillions of myosin molecules present in a ventricle or myocyte. We therefore searched for the differences between single myosin molecules of the LV and RV of failing hearts In-situ. We show that the parameters that define the mechanical characteristics of working myosin (kinetic rates and the distribution of spatial orientation of myosin lever arm) were the same in both ventricles. These results suggest that there is no difference in the way myosin interacts with thin filaments in myocytes of failing hearts, and suggests that the difference in pumping efficiencies are caused by interactions between muscle proteins other than myosin or that they are purely morphological.

11.
Front Cardiovasc Med ; 2: 35, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26664906

RESUMEN

Contraction of muscles results from the ATP-coupled cyclic interactions of the myosin cross-bridges with actin filaments. Macroscopic parameters of contraction, such as maximum tension, speed of shortening, or ATPase activity, are unlikely to reveal differences between the wild-type and mutated (MUT) proteins when the level of transgenic protein expression is low. This is because macroscopic measurements are made on whole organs containing trillions of actin and myosin molecules. An average of the information collected from such a large assembly is bound to conceal any differences imposed by a small fraction of MUT molecules. To circumvent the averaging problem, the measurements were done on isolated ventricular myofibril (MF) in which thin filaments were sparsely labeled with a fluorescent dye. We isolated a single MF from a ventricle, oriented it vertically (to be able measure the orientation), and labeled 1 in 100,000 actin monomers with a fluorescent dye. We observed the fluorescence from a small confocal volume containing approximately three actin molecules. During the contraction of a ventricle actin constantly changes orientation (i.e., the transition moment of rigidly attached fluorophore fluctuates in time) because it is repetitively being "kicked" by myosin cross-bridges. An autocorrelation functions (ACFs) of these fluctuations are remarkably sensitive to the mutation of myosin. We examined the effects of Alanine to Threonine (A13T) mutation in the myosin regulatory light chain shown by population studies to cause hypertrophic cardiomyopathy. This is an appropriate example, because mutation is expressed at only 10% in the ventricles of transgenic mice. ACFs were either "Standard" (Std) (decaying monotonically in time) or "Non-standard" (NStd) (decaying irregularly). The sparse labeling of actin also allowed the measurement of the spatial distribution of actin molecules. Such distribution reflects the interaction of actin with myosin cross-bridges and is also remarkably sensitive to myosin mutation. The result showed that the A13T mutation caused 9% ACFs and 9% of spatial distributions of actin to be NStd, while the remaining 91% were Std, suggesting that the NStd performances were executed by the MUT myosin heads and that the Std performances were executed by non-MUT myosin heads. We conclude that the method explored in this study is a sensitive and valid test of the properties of low prevalence mutations in sarcomeric proteins.

12.
Dyes Pigm ; 117: 16-23, 2015 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-26594075

RESUMEN

A cationic azadioxatriangulenium (ADOTA) dye was entrapped in silica thin films obtained by the sol-gel process and in poly (vinyl) alcohol (PVA) thin films. Azadioxatriangulenium is a red emitting fluorophore with a long fluorescence lifetime of ~20 ns. The fluorescent properties of azadioxatriangulenium in silica thin films and PVA films were studied by means of steady-state and time resolved fluorescence techniques. We have found that the azadioxatriangulenium entrapped in silica thin film has a wider fluorescence lifetime distribution (Lorentzian distribution), lower fluorescence efficiencies, shorter lifetimes compared to Azadioxatriangulenium in a PVA film. The local environment of azadioxatriangulenium molecules in the silica thin film is rich with water and ethanol, which creates the possibility of forming excited state aggregates due to high concentration of dye within a small confined area. In contrast to the PVA matrices, the porous silica films allow restricted rotations of Azadioxatriangulenium molecules, which result in faster and complex fluorescence anisotropy decays suggesting energy migration among dye molecules.

13.
Nanoscale ; 7(42): 17729-34, 2015 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-26452215

RESUMEN

In this report, we describe a plasmonic platform with silver fractals for metal enhanced fluorescence (MEF) measurements. When a dye containing surface was brought into contact with silver fractals, a significantly enhanced fluorescence signal from the dye was observed. Fluorescence enhancement was studied with the N-methyl-azadioxatriangulenium chloride salt (Me-ADOTA·Cl) in PVA films made from 0.2% PVA (w/v) solution spin-coated on a clean glass coverslip. The Plasmonic Platforms (PP) were assembled by pressing together silver fractals on one glass slide and a separate glass coverslip spin-coated with a uniform Me-ADOTA·Cl in PVA film. In addition, we also tested ADOTA labeled human serum albumin (HSA) deposited on a glass slide for potential PP bioassay applications. Using the new PP, we could achieve more than a 20-fold fluorescence enhancement (bright spots) accompanied by a decrease in the fluorescence lifetime. The experimental results were used to calculate the extinction (excitation) enhancement factor (GA) and fluorescence radiative rate enhancements factor (GF). No change in emission spectrum was observed for a dye with or without contact with fractals. Our studies indicate that this type of PP can be a convenient approach for constructing assays utilizing metal enhanced fluorescence (MEF) without the need for depositing the material directly on metal structures platforms.


Asunto(s)
Fractales , Plata/química , Colorantes Fluorescentes/química , Humanos , Microscopía Confocal , Nanoestructuras/química , Albúmina Sérica/química , Albúmina Sérica/metabolismo
14.
PLoS One ; 10(4): e0123096, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25848957

RESUMEN

Astrocytes outnumber neurons and serve many metabolic and trophic functions in the mammalian brain. Preserving astrocytes is critical for normal brain function as well as for protecting the brain against various insults. Our previous studies have indicated that methylene blue (MB) functions as an alternative electron carrier and enhances brain metabolism. In addition, MB has been shown to be protective against neurodegeneration and brain injury. In the current study, we investigated the protective role of MB in astrocytes. Cell viability assays showed that MB treatment significantly protected primary astrocytes from oxygen-glucose deprivation (OGD) & reoxygenation induced cell death. We also studied the effect of MB on cellular oxygen and glucose metabolism in primary astrocytes following OGD-reoxygenation injury. MB treatment significantly increased cellular oxygen consumption, glucose uptake and ATP production in primary astrocytes. In conclusion our study demonstrated that MB protects astrocytes against OGD-reoxygenation injury by improving astrocyte cellular respiration.


Asunto(s)
Astrocitos/fisiología , Respiración de la Célula/efectos de los fármacos , Glucosa/metabolismo , Azul de Metileno/farmacología , Fármacos Neuroprotectores/farmacología , Adenosina Trifosfato/biosíntesis , Animales , Astrocitos/efectos de los fármacos , Hipoxia de la Célula , Supervivencia Celular , Células Cultivadas , Citoprotección , Evaluación Preclínica de Medicamentos , Glucógeno/biosíntesis , Hexoquinasa/metabolismo , Ratones Endogámicos C57BL , Oxígeno/metabolismo , Consumo de Oxígeno
15.
J Appl Biomech ; 31(2): 122-7, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25411762

RESUMEN

Girls' lacrosse is fundamentally a different sport than boys' lacrosse, and girls are not required to wear protective headgear. Recent epidemiological studies have found that stick checks are the leading cause of concussion injury in girls' lacrosse. The purpose of this study was to determine stick check speeds and estimate the head acceleration associated with direct checks to the head. In addition, we briefly examine if commercially available headgear can mitigate the accelerations. Seven (n = 7) experienced female lacrosse players checked, with varying severity, a NOSCAE and an ASTM headform. Stick speed at impact and the associated peak linear accelerations of the headform were recorded. The NOCSAE headform was fitted with four commercially available headgear and similar stick impact testing was performed. The median stick impact speed was 8.1 m/s and 777 deg/s. At these speeds, peak linear acceleration was approximately 60g. Three out of the four headgear significantly reduced the peak linear acceleration when compared with the bare headform. These data serve as baseline for understanding the potential mechanism and reduction of concussions from stick impacts in girls' lacrosse.


Asunto(s)
Aceleración , Movimientos de la Cabeza/fisiología , Dispositivos de Protección de la Cabeza , Cabeza/fisiología , Deportes de Raqueta/fisiología , Equipo Deportivo , Adolescente , Niño , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Modelos Biológicos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
ACS Appl Mater Interfaces ; 6(21): 18780-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25296293

RESUMEN

In this report we describe a preparation of silver wires (SWs) on gold mirrors and its application to surface enhanced fluorescence (SEF) using a new methodology. Silica protected gold mirrors were drop-coated with a solution of silver triangular nanoprisms. The triangular nanoprisms were slowly air-dried to get silver wires that self-assembled on the gold mirrors. Fluorescence enhancement was studied using methyl azadioxatriangulenium chloride (Me-ADOTA · Cl) dye in PVA spin-coated on a clean glass coverslip. New Plasmonic Platforms (PPs) were assembled by placing a mirror with SWs in contact with a glass coverslip spin-coated with a uniform Me-ADOTA · Cl film. It was shown that surface enhanced fluorescence is a real phenomenon, not just an enhancement of the fluorescence signal due to an accumulation of the fluorophore on rough nanostructure surfaces. The average fluorescence enhancement was found to be about 15-fold. The lifetime of Me-ADOTA · Cl dye was significantly reduced (∼ 4 times) in the presence of SWs. Moreover, fluorescence enhancement and lifetime did not show any dependence on the excitation light polarization.


Asunto(s)
Colorantes Fluorescentes/química , Oro/química , Microscopía Fluorescente/métodos , Nanocables/química , Plata/química , Resonancia por Plasmón de Superficie/métodos
17.
Cell Biochem Biophys ; 70(2): 923-32, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24839116

RESUMEN

Presenilin-1 (PS1) protein acts as passive ER Ca(2+) leak channels that facilitate passive Ca(2+) leak across ER membrane. Mutations in the gene encoding PS1 protein cause neurodegeneration in the brains of patients with familial Alzheimer's disease (FAD). FADPS1 mutations abrogate the function of ER Ca(2+) leak channel activity in human neuroblastoma SK-N-SH cells in vitro (Das et al., J Neurochem 122(3):487-500, 2012) and in mouse embryonic fibroblasts. Consequently, genetic deletion or mutations of the PS1 gene cause calcium (Ca(2+)) signaling abnormalities leading to neurodegeneration in FAD patients. By analogy with other known ion channels it has been proposed that the functional PS1 channels in ER may be multimers of several PS1 subunits. To test this hypothesis, we conjugated the human PS1 protein with an NH2-terminal YFP-tag and a COOH-terminal CFP-tag. As expected YFP-PS1, and PS1-CFP were found to be expressed on the plasma membranes by TIRF microscopy, and both these fusion proteins increased ER Ca(2+) leak channel activity similar to PS1 (WT) in SK-N-SH cells, as determined by functional calcium imaging. PS1-CFP was either expressed alone or together with YFP-PS1 into SK-N-SH cell line and the interaction between YFP-PS1 and PS1-CFP was determined by Förster resonance energy transfer analysis. Our results suggest interaction between YFP-PS1 and PS1-CFP confirming the presence of a dimeric or multimeric form of PS1 in SK-N-SH cells. Lateral diffusion of PS1-CFP and YFP-PS1 in the plasma membrane of SK-N-SH cells was measured in the absence or in the presence of glycerol by fluorescence correlation spectroscopy to show that both COOH-terminal and NH2-terminal of human PS1 are located on the cytoplasmic side of the plasma membrane. Therefore, we conclude that both COOH-terminal and NH2-terminal of human PS1 may also be oriented on the cytosolic side of ER membrane.


Asunto(s)
Membrana Celular/metabolismo , Transferencia Resonante de Energía de Fluorescencia , Presenilina-1/metabolismo , Línea Celular Tumoral , Citoplasma/metabolismo , Difusión , Humanos , Presenilina-1/química , Transporte de Proteínas
18.
Curr Pharm Biotechnol ; 14(13): 1139-44, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24853092

RESUMEN

Although BSA Au clusters fluoresce in red region (λmax: 650 nm), they are of limited use due to low fluorescence quantum yield (~6%). Here we report an enhanced fluorescence imaging application of fluorescent bio-nano probe BSA Au clusters using multipulse excitation scheme. Multipulse excitation takes advantage of long fluorescence lifetime (> 1 µs) of BSA Au clusters and enhances its fluorescence intensity 15 times over short lived cellular auto-fluorescence. Moreover we have also shown that by using time gated detection strategy signal (fluorescence of BSA Au clusters) to noise (auto-fluorescence) ratio can be increased by 30 fold. Thereby with multipulse excitation long lifetime probes can be used to develop biochemical assays and perform optical imaging with zero background.


Asunto(s)
Colorantes Fluorescentes , Oro , Albúmina Sérica Bovina , Línea Celular Tumoral , Fluorescencia , Humanos , Nanoestructuras , Relación Señal-Ruido , Espectrometría de Fluorescencia
19.
Curr Pharm Biotechnol ; 14(13): 1134-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-22339171

RESUMEN

In our previous paper we showed that the MMP-9 enzyme recognizes a specific peptide sequence, Lys-Gly- Pro-Arg-Ser-Leu-Ser-Gly-Lys, and cleaves the peptide into two parts [1]. In this study, the peptide is labeled with two dyes, carboxyfluorescein (5-FAM) and Cy5. A highly efficient energy transfer of over 80% results in a dominant emission of Cy5 at ~670 nm with an excitation of 470 nm. Severance of the peptide by the MMP-9 enzyme eliminates Förster Resonance Energy Transfer (FRET) and strongly increases the fluorescence of the 5-FAM dye. In this manuscript we describe the strategy for a FRET-based method for MMP-9 enzyme detection. The basic aim is to apply a ratio-metric sensing technique in which a ratio of green/red fluorescence intensity is measured as a function of enzyme concentration. The ratio-metric method eliminates many experimental variables and enables accurate MMP-9 detection.


Asunto(s)
Transferencia Resonante de Energía de Fluorescencia/métodos , Metaloproteinasa 9 de la Matriz/análisis , Péptidos/química , Células Cultivadas , Color , Activación Enzimática/efectos de los fármacos , Fluorescencia , Colorantes Fluorescentes , Humanos , Cinética , Neutrófilos/efectos de los fármacos , Neutrófilos/enzimología , Radiometría
20.
Curr Pharm Biotechnol ; 14(13): 1127-33, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-22394126

RESUMEN

Fluorescent nanodiamonds (FNDs) are one of the new and very promising biocompatible nanomaterials that can be used both as a fluorescence imaging agent and a highly versatile platform for controlled functionalization to target and deliver a wide spectrum of therapeutic agents. Among the remarkable fluorescence properties are excellent photostability, emission between 600-700nm, quantum yield of 1 and moderately long fluorescence lifetimes. However the low absorption cross section of fluorescent (N-V)(-) centers limits FNDs' brightness. In this work we show that an approach based on the Forster resonance energy transfer (FRET) may significantly enhance the fluorescence signal observed from a single ND. We demonstrate that organic dyes (fluorophores) attached to the FND surface can efficiently transfer the excitation energy to (N-V)(-) centers. Multiple dyes positioned in close proximity to the ND facile surface may serve as harvesting antennas transferring excitation energy to the fluorescent centers. We propose that, with the help of some of the functional groups present on the FND surface, we can either directly link flurophores or use scalable dendrimer chemistry to position many organic dyes at a calibrated distance. Also, the remaining multiple functional groups will be still available for particle targeting and drug delivery. This opens a new way for designing a new type of theranostics particles of ultrahigh brightness, high photostability, specific targeting, and high capacity for drug delivery.


Asunto(s)
Diamante/química , Transferencia Resonante de Energía de Fluorescencia/métodos , Colorantes Fluorescentes , Nanoestructuras/química , Fluoresceína-5-Isotiocianato , Fluorescencia , Microscopía Confocal , Albúmina Sérica Bovina/química , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA