Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Theor Med Bioeth ; 21(4): 339-54, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11103626

RESUMEN

In a time when we as a society are in the process of deciding what our basic rights to health care are, it is critically important for us to have a full and complete understanding of what constitutes health. We argue for an analysis of health according to which certain states are healthy not in themselves but because they allow an individual to reach actual goals. Recognizing that the goals of an individual considered from the point of view of biology and the goals of the same individual considered as an agent in the world might be different, we introduce a distinction between the health of an individual qua organism and the health of an individual qua person. We then argue that this distinction characterizes the evaluations made by patients and healthcare providers better than the widely discussed distinction between disease and illness.


Asunto(s)
Salud , Filosofía Médica , Enfermedad , Objetivos , Humanos , Valores Sociales
4.
Anesthesiology ; 52(4): 313-7, 1980 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-7362051

RESUMEN

The Sentorr is a gas chromatograph that monitors Pa2 and PaCO2 every 4 min from a probe placed through an intraarterial cannula. The accuracy of this device and complications resulting from its use were studied in 46 patients undergoing cardiac surgical procedures with oxygen to nitrous oxide-halothane anesthesia. Sentorr blood-gas values were compared with simultaneous samples analyzed with standard electrodes. During relatively steady states of respiration and circulation, and in the lower (50-125 torr) range of oxygen tensions, the measurements correlated closely (r = 0.92). The device also functioned well during low-flow states, but during hypothermic cardiopulmonary bypass, the correlation was only fair (r = 0.62). When nitrous oxide was present in the inspired gas, Sentorr PaO2 readings were a third lower than actual PO2 measurements, an effect corroborated by an in-vitro experiment. Directional changes of oxygen and carbon dioxide tensions were always correct in all situations. Placement of the probe in a radial artery was unsatisfactory because it significantly interfered with blood pressure measurement and resulted in inaccurate results for this patient population. The brachial artery was a satisfactory site for insertion, although attenuation of the arterial pressure tracing by the presence of a Sentorr probe resulted in systolic pressure readings that averaged 12 torr lower with mean arterial pressure readings 5 torr lower. No increase in morbidity due to use of a Sentorr probe for brachial arterial pressure monitoring could be identified. The most potentially serious complication encountered was transient loss of a palpable pulse without interruption of blood flow in one or more distal arteries after decannulation. This was observed in seven patients (four of whom had diminished distal pulses whith normal flow before cannulation).


Asunto(s)
Análisis de los Gases de la Sangre/instrumentación , Monitoreo Fisiológico/métodos , Adulto , Anciano , Análisis de los Gases de la Sangre/métodos , Presión Sanguínea , Arteria Braquial , Dióxido de Carbono/sangre , Procedimientos Quirúrgicos Cardíacos , Cromatografía de Gases/métodos , Estudios de Evaluación como Asunto , Humanos , Persona de Mediana Edad , Monitoreo Fisiológico/efectos adversos , Monitoreo Fisiológico/instrumentación , Óxido Nitroso , Oxígeno/sangre , Presión Parcial
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA