Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 1 de 1
1.
PLoS One ; 19(5): e0297880, 2024.
Article En | MEDLINE | ID: mdl-38768181

INTRODUCTION: Hyperinflation is a common procedure to clear secretion, increase lung compliance and enhance oxygenation in mechanically ventilated patients. Hyperinflation can be provided as manual hyperinflation (MHI) or ventilator hyperinflation (VHI), where outcomes depend upon the methods of application. Hence it is crucial to assess the application of techniques employed in Sri Lanka due to observed variations from recommended practices. OBJECTIVE: This study is aimed to evaluate the application and parameters used for MHI and VHI by physiotherapists in intensive care units (ICUs) in Sri Lanka. METHODOLOGY: An online survey was conducted among physiotherapists who are working in ICUs in Sri Lanka using WhatsApp groups and other social media platforms. RESULTS: A total of 96 physiotherapists responded. The survey comprised of three sections to obtain information about socio-demographic data, MHI practices and VHI practices. Most of the respondents (47%) worked in general hospitals and 74% of participants had a bachelor's degree in physiotherapy; 31.3% had 3-6 years of experience; 93.8% used hyperinflation, and 78.9% used MHI. MHI was performed routinely and as needed to treat low oxygen levels, abnormal breath sounds, and per physician orders while avoiding contraindications. Self-inflation bags are frequently used for MHI (40.6%). Only a few participants (26%) used a manometer or tracked PIP. In addition to the supine position, some participants (37.5%) used the side-lying position. Most physiotherapists followed the recommended MHI technique: slow squeeze (57.3%), inspiratory pause (45.8%), and quick release (70.8%). VHI was practised by 19.8%, with medical approval and it was frequently performed by medical staff compared to physiotherapists. Treatment time, number of breaths, and patient positioning varied, and parameters were not well-defined. CONCLUSION: The study found that MHI was not applied with the recommended PIP, and VHI parameters were not identified. The study indicates a need to educate physiotherapists about current VHI and MHI practice guidelines.


Physical Therapists , Respiration, Artificial , Humans , Sri Lanka , Surveys and Questionnaires , Respiration, Artificial/methods , Male , Female , Adult , Intensive Care Units , Critical Care/methods , Ventilators, Mechanical/statistics & numerical data
...