1.
J Radiol Prot ; 44(3)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38950524

RESUMEN

The aim of this study was to investigate the performance of eight digital radiography systems and to optimise the dose-image quality relationship for digital pelvis radiography. The study involved eight digital radiography systems used for general examinations at Vilnius University Hospital Santaros Klinikos. An anthropomorphic pelvic phantom (CIRS, US) was used to simulate a patient undergoing clinical pelvis radiography. Dose quantities entrance surface dose, dose area product (DAP) and exposure parameters (kVp, mA, mAs) were measured and the effects on the images were evaluated, considering physical contrast to noise ratio (CNR) and observer-based evaluations as image quality metrics. Increasing the tube voltage by 5 kVp from standard protocol led to a reduction in radiation dose (DAP) by 12%-20% with a slight impact on image quality (CNR decreases by 2%-10%). There was an inter-observer variability in image rating across different equipment (kappa value between 0 and 0.3); however, both observers agreed that increasing kVp up to 85-90 kV had no effect on perceived image quality. The results indicate that optimisation strategies should be tailored specifically for each x-ray system since significant performance differences and wide variations in radiation dose exist across various digital radiography systems used in clinical settings. The use of high kVp can be used for dose optimisation in digital pelvis radiography without compromising image diagnostic accuracy.


Asunto(s)
Pelvis , Fantasmas de Imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica , Pelvis/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
AIDS Res Ther ; 11: 37, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25745500

RESUMEN

INTRODUCTION: We report a case of an adult patient with human immunodeficiency virus (HIV), acute respiratory distress syndrome (ARDS) and ventilator associated pneumonia (VAP) caused by multidrug resistant (MDR) bacteria that was successfully managed with veno-venous extracorporeal membrane oxygenation (ECMO). CASE REPORT: A 25 year old male with no significant past medical history had been admitted to a local hospital due to dyspnea and fever. His pulmonary function subsequently failed necessitating mechanical ventilation (MV) and introduction of ECMO support. The patient was transported for 300 km by road on ECMO to a tertiary medical center. The diagnosis of ARDS, HIV infection and MDR bacterial and fungal VAP was made. Patient was successfully treated with antiretroviral therapy (ART), anti-infective agents and 58 days of veno-venous ECMO support, with complete resolution of the respiratory symptoms. CONCLUSION: HIV infected patients with ARDS and MDR bacterial VAP whose HIV replication is controlled by ART could be successfully managed with ECMO.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA