1.
Pacing Clin Electrophysiol ; 46(3): 268-270, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36269180

RESUMEN

Leadless pacemaker (LPs) is a safe device and the implantation rates of this device is increasing. The device extraction and replacement are today a challenging procedures especially in case of infections, fragile and older patients or in unfavorable venous anatomy; LPs can be a valid alternative strategy in these cases. We report a case of management of a patient with multiple previous device replacements and extractions, with malfunction of transvenous pacemaker and with a fibrous membrane between the walls of the ventricular lead and the superior vena cava (SVC), who underwent a successful LP implantation.


Asunto(s)
Estimulación Cardíaca Artificial , Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial/métodos , Vena Cava Superior , Lipopolisacáridos , Resultado del Tratamiento