Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 12 de 12
3.
AJR Am J Roentgenol ; 221(3): 344-353, 2023 09.
Article En | MEDLINE | ID: mdl-37132549

BACKGROUND. Observation periods after renal mass biopsy (RMB) range from 1 hour to overnight hospitalization. Short observation may improve efficiency by allowing use of the same recovery bed and other resources for RMBs in additional patients. OBJECTIVE. The purpose of this study was to evaluate the frequency, timing, and nature of complications after RMB, as well as to identify characteristics associated with such complications. METHODS. This retrospective study included 576 patients (mean age, 64.9 years; 345 men, 231 women) who underwent percutaneous ultrasound- or CT-guided RMB at one of three hospitals, performed by 22 radiologists, between January 1, 2008, and June 1, 2020. The EHR was reviewed to identify postbiopsy complications, which were classified as bleeding-related or non-bleeding-related and as acute (< 24 hours), subacute (24 hours to 30 days), or delayed (> 30 days). Deviations from normal clinical management (analgesia, unplanned laboratory testing, or additional imaging) were identified. RESULTS. Acute and subacute complications occurred after 3.6% (21/576) and 0.7% (4/576) of RMBs, respectively. No delayed complication or patient death occurred. A total of 76.2% (16/21) of acute complications were bleeding-related. A deviation from normal clinical management occurred after 1.6% (9/551) of RMBs that had no associated postbiopsy complication. Among the 16 patients with bleeding-related acute complications, all experienced a deviation, with mean time to deviation of 56 ± 47 (SD) minutes (range, 10-162 minutes; ≤ 120 minutes in 13/16 patients). The five non-bleeding-related acute complications all presented at the time of RMB completion. The four subacute complications occurred from 28 hours to 18 days after RMB. Patients with, versus those without, a bleeding-related complication had a lower platelet count (mean, 197.7 vs 250.4 × 109/L, p = .01) and greater frequency of entirely endophytic renal masses (47.4% vs 19.6%, p = .01). CONCLUSION. Complications after RMB were uncommon and presented either within 3 hours after biopsy or more than 24 hours after biopsy. CLINICAL IMPACT. A 3-hour monitoring window after RMB before patient discharge (in the absence of deviation from normal clinical management and complemented by informing patients of the low risk of a subacute complication) may provide both safe patient management and appropriate resource utilization.


Kidney Neoplasms , Nephrectomy , Male , Humans , Female , Middle Aged , Aged , Retrospective Studies , Biopsy/adverse effects , Biopsy/methods , Nephrectomy/adverse effects , Hemorrhage/etiology , Image-Guided Biopsy/adverse effects , Ultrasonography/adverse effects , Kidney Neoplasms/pathology , Kidney/diagnostic imaging , Kidney/pathology
4.
J Emerg Med ; 62(3): 324-331, 2022 03.
Article En | MEDLINE | ID: mdl-35067394

BACKGROUND: In the province of Quebec (Canada), paramedics use the esophageal tracheal Combitube (ETC) for prehospital airway management. OBJECTIVES: Our main objective was to determine the proportion of patients with successful ventilation achieved after ETC use. Our secondary aim was to determine the number of ETC insertion attempts required to ventilate the patient. METHOD: This is a retrospective cohort study. All patients who had ≥1 attempt to insert an ETC during prehospital care between January 1, 2017 and December 31, 2018 were included. Prehospital and in-hospital data were extracted. Successful ventilation was defined as thorax elevation, lung sounds on chest auscultation, or positive end-tidal capnography after ETC insertion. RESULTS: A total of 580 emergency medical services interventions (99.3% cardiac arrests) were included. Most patients were men (62.5%) with a mean age 67.0 years (SD 17.6 years), and 35 (13.1%) of the 298 patients transported to emergency department survived to hospital discharge. Sufficient information to determine whether ventilation was successful or not was available for 515 interventions. Ventilation was achieved during 427 (82.7%) of these interventions. The number of ETC insertion attempts was available for 349 of the 427 successful ETC use. Overall, the first insertion resulted in successful ventilation during 294 interventions for an overall proportion of first-pass success ranging between 57.1% and 72.1%. CONCLUSION: Proportions of successful ventilation and ETC first-pass success are lower than those reported in the literature with supraglottic airway devices. The reasons explaining these lower rates and their impact on patient-centered outcomes need to be studied.


Emergency Medical Services , Heart Arrest , Aged , Airway Management , Emergency Medical Services/methods , Female , Humans , Intubation, Intratracheal/methods , Male , Retrospective Studies
5.
J Head Trauma Rehabil ; 36(2): 96-102, 2021.
Article En | MEDLINE | ID: mdl-32826417

OBJECTIVE: To provide an expert consensus definition of persistent postconcussion symptoms following a mild traumatic brain injury (mTBI). PARTICIPANTS: Canadian healthcare professionals caring for patients with mTBI. DESIGN: Online Delphi process. MAIN MEASURES: A first Delphi round documented important dimensions or criteria to consider when defining persistent symptoms. Expert opinions were then resubmitted in 4 subsequent Delphi rounds and their relevance was rated using a 9-point Likert scale. An item with a median rating of 7 or more and a sufficient level of agreement were considered consensual. RESULTS: After 5 rounds, consensus was reached on a set of criteria that can be summarized as follows: presence of any symptom that cannot be attributed to a preexisting condition and that appeared within hours of an mTBI, that is still present every day 3 months after the trauma, and that has an impact on at least one sphere of a person's life. CONCLUSION: This Delphi consensus proposes a set of criteria that support a more uniform definition of persistent symptoms in mild TBI among clinicians and researchers. This definition may help clinicians better identify persistent postconcussion symptoms and improve patient management.


Brain Concussion , Post-Concussion Syndrome , Brain Concussion/complications , Brain Concussion/diagnosis , Canada , Consensus , Delphi Technique , Humans , Post-Concussion Syndrome/diagnosis
6.
Article En | MEDLINE | ID: mdl-30714916

Time-domain plane-wave imaging (PWI) has recently emerged in medical imaging and is now taking to nondestructive testing (NDT) due to its ability to provide images of good resolution and contrast with only a few steered plane waves. Insonifying a medium with plane waves is a particularly interesting approach in 3-D imaging with matrix arrays because it allows to tremendously reduce the volume of data to be stored and processed as well as the acquisition time. However, even if the data volume is reduced with plane wave emissions, the image reconstruction in the time domain with a delay-and-sum algorithm is not sufficient to achieve low computation times in 3-D due to the number of voxels. Other reconstruction algorithms take place in the wavenumber-frequency (f-k) domain and have been shown to accelerate computation times in seismic imaging and in synthetic aperture radar. In this paper, we start from time-domain PWI in 2-D and compare it to two algorithms in the f-k domain, coming from the Stolt migration in seismic imaging and the Lu theory of limited diffraction beams in medical imaging. We then extend them to immersion testing configurations where a linear array is facing a plane water-steel interface. Finally, the reconstruction algorithms are generalized to 3-D imaging with matrix arrays. A comparison dwelling on image quality and algorithmic complexities is provided, as well as a theoretical analysis of the image amplitudes and the limits of each method. We show that the reconstruction schemes in the f-k domain improve the lateral resolution and offer a theoretical and numerical computation gain of up to 36 in 3-D imaging in a realistic NDT configuration.


Imaging, Three-Dimensional/methods , Ultrasonography/methods , Algorithms , Equipment Design , Fourier Analysis , Transducers
7.
Bioorg Med Chem Lett ; 27(18): 4512-4513, 2017 09 15.
Article En | MEDLINE | ID: mdl-28838689

Investigations into the pharmacology of different types of cys-loop GABA receptor have relied for years on the chemical modification of GABA-like compounds. The GABA metabolite GABOB is an attractive molecule to modify due to its convenient chemical structure. In the process of developing new GABA-mimic compounds from GABOB as a starting compound three small molecule GABA derivatives were synthesized using a variety of chemical transformations. Amongst these, a new and reliable method to synthesize TACA (trans-4-aminocrotonic acid) is reported.


Crotonates/pharmacology , GABA-A Receptor Agonists/pharmacology , Receptors, GABA-A/metabolism , Animals , Crotonates/chemical synthesis , Crotonates/chemistry , Dose-Response Relationship, Drug , GABA-A Receptor Agonists/chemical synthesis , GABA-A Receptor Agonists/chemistry , Molecular Structure , Oocytes/drug effects , Structure-Activity Relationship , Xenopus laevis
8.
Article En | MEDLINE | ID: mdl-28391193

In this paper, defects in a high density polyethylene pipe are imaged with the total focusing method. The viscoelastic attenuation of this material greatly reduces the signal level and leads to a poor signal-to-noise ratio (SNR) due to electronic noise. To improve the image quality, the decomposition of the time reversal operator method is combined with the spatial Hadamard coded transmissions before calculating images in the time domain. Because the Hadamard coding is not compatible with conventional imaging systems, this paper proposes two modified coding methods based on sparse Hadamard matrices with +1/0 coefficients. The SNRs expected with the different spatial codes are demonstrated, and then validated on both simulated and experimental data. Experiments are performed with a transducer array in contact with the base material of a polyethylene pipe. In order to improve the noise filtering procedure, the singular values associated with electronic noise are expressed on the basis of the random matrix theory. This model of noise singular values allows a better identification of the defect response in noisy experimental data. Finally, the imaging method is evaluated in a more industrial inspection configuration, where an immersion array probe is used to image defects in a butt fusion weld with a complex geometry.

9.
J Acoust Soc Am ; 140(1): 541, 2016 07.
Article En | MEDLINE | ID: mdl-27475176

In the present work, the Synthetic Transmit Aperture (STA) imaging is combined with the Decomposition of the Time Reversal Operator (DORT) method to image a coarse grained austenitic-ferritic steel using a contact transducer array. The highly heterogeneous structure of this material produces a strong scattering noise in ultrasound images. Furthermore, the surface waves guided along the array interfere with the bulk waves backscattered by defects. In order to overcome these problems, the DORT method is applied before calculating images with the STA algorithm. The method consists in analyzing in the frequency domain the singular values and singular vectors of the full array transfer matrix. This paper first presents an analysis of the singular values of different waves contained in the data acquisition, which facilitates the identification of the subspace associated with the surface guided waves for filtering operations. Then, a filtered matrix is defined where the contribution of structural noise and guided waves are reduced. Finally, in the time domain, the STA algorithm is applied to this matrix in order to calculate an image with reduced structural noise. Experiments demonstrate that this filtering improves the signal-to-noise ratio by more than 12 dB in comparison with the STA image before filtering.

10.
Ultrasonics ; 64: 128-38, 2016 Jan.
Article En | MEDLINE | ID: mdl-26323547

This paper describes a new ultrasonic array imaging method for Non-Destructive Testing (NDT) which is derived from the medical Plane Wave Imaging (PWI) technique. The objective is to perform fast ultrasound imaging with high image quality. The approach is to transmit plane waves at several angles and to record the back-scattered signals with all the array elements. Focusing in receive is then achieved by coherent summations of the signals in every point of a region of interest. The medical PWI is generalized to immersion setups where water acts as a coupling medium and to multimodal (direct, half-skip modes) imaging in order to detect different types of defects (inclusions, porosities, cracks). This method is compared to the Total Focusing Method (TFM) which is the reference imaging technique in NDT. First, the two post-processing algorithms are described. Then experimental results with the array probe either in contact or in immersion are presented. A good agreement between the TFM and the PWI is observed, with three to ten times less transmissions required for the PWI.

11.
Emerg Med J ; 30(8): 688-9, 2013 Aug.
Article En | MEDLINE | ID: mdl-23872997

A short-cut review was carried out to establish whether propofol can improve recovery and reduce recurrence in patients presenting to the emergency department with acute migraine. Three studies were directly relevant to the question. The author, date and country of publication, patient group studied, study type, relevant outcomes, results and study weaknesses of these papers are shown in table 1. The clinical bottom line is that propofol might be a safe and effective therapy in the treatment of migraine, but more well-designed trials are needed to compare with standard therapy before widespread use is considered.


Anesthetics, Intravenous/therapeutic use , Evidence-Based Emergency Medicine , Migraine Disorders/drug therapy , Propofol/therapeutic use , Humans
12.
Ultrasonics ; 45(1-4): 178-87, 2006 Dec.
Article En | MEDLINE | ID: mdl-17067650

The layer-multiple-scattering method is developed to study wave propagation through two-dimensional lattices of cylindrical inclusions in an elastic medium. The lattices are a series of periodically spaced infinite one-dimensional periodic gratings (or rows) of inclusions. The layer-multiple-scattering method allows the analysis of the reflection and transmission properties of the two-dimensional lattice, provided those of each row are known. These are later determined by means of an exact multiple scattering formalism based on modal series developments. A new characteristic equation is obtained that describes the Bloch wave propagation into the infinite lattice. Lattices with empty and fluid-filled inclusions are compared. The comparison shows the existence of pass and stop bands due to the resonances of the fluid-filled inclusions. Resonant inclusions allow the opening of narrow pass bands inside phononic stop band, which is an interesting phenomenon for demultiplexing problems. It is worth noting that inclusion resonances have nothing to do with resonances due to defects, as they involve the whole lattice. In addition, it is shown that stop bands, at an oblique incidence, due to a strong coupling between longitudinal and transverse waves, are related to dispersive guided waves that propagate in the direction of the reticular planes of the lattices.

...