Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Clin Gastroenterol ; 55(3): 239-243, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32324678

RESUMEN

GOAL: The goal of this study was to assess the clinical performance of an investigational in vitro fecal calprotectin immunoassay for differentiating inflammatory bowel disease (IBD) from irritable bowel syndrome (IBS). BACKGROUND: Fecal calprotectin is a stool biomarker that can assist in the detection of intestinal inflammation and is utilized to identify individuals who have a higher chance of having IBD and who require further invasive tests. Current assays exhibit variable performance. MATERIALS AND METHODS: This study was a multicenter, cross-sectional analysis of prospectively collected stool samples from patients 4 years of age or older who presented with gastrointestinal (GI) symptoms and underwent colonoscopy for diagnostic confirmation. IBD was diagnosed based on clinical, endoscopic, and histologic findings. IBS was diagnosed based on Rome III Criteria and negative colonoscopy. Stool samples were extracted and tested on the DiaSorin LIAISON XL using the LIAISON Calprotectin Assay. RESULTS: A total of 240 patients (67% female) were included in the study. In total, 102 patients had IBD (54% ulcerative colitis), 67 had IBS, and 71 had other GI disorders. Median fecal calprotectin levels were significantly higher in patients with IBD [522 µg/g; 95% confidence interval (CI): 354-970 µg/g] compared with IBS (34.5 µg/g; 95% CI: 19.7-44.2 µg/g, P<0.001) and other GI disorders (28.6 µg/g; 95% CI: 18.7-40.3 µg/g, P<0.001). Receiver operating characteristic curve analysis indicated a fecal calprotectin cutoff of 94 µg/g for distinguishing IBD from other GI disorders with an area under the curve of 0.964 (sensitivity=92.2%, specificity=88.4%). CONCLUSION: The automated LIAISON Calprotectin assay brings efficient calprotectin testing to the laboratory with a time to the first result of 35 minutes and is a sensitive marker for distinguishing IBD from IBS with a cutoff of ∼100 µg/g.


Asunto(s)
Colitis Ulcerosa , Enfermedades Inflamatorias del Intestino , Síndrome del Colon Irritable , Biomarcadores , Colitis Ulcerosa/diagnóstico , Estudios Transversales , Heces , Femenino , Humanos , Enfermedades Inflamatorias del Intestino/diagnóstico , Síndrome del Colon Irritable/diagnóstico , Complejo de Antígeno L1 de Leucocito , Masculino
2.
Biomed Res Int ; 2020: 7189519, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32280698

RESUMEN

BACKGROUND: Antigens derived from Helicobacter pylori can be used as stool biomarkers to assist in the diagnosis of H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian. METHODS: This prospective multisite study enrolled patients undergoing an esophagogastroduodenoscopy with collection of biopsy and stool specimens. Adult patients (≥22 years) participated in the study from February 2017 to August 2018. Specimens of the stomach were tested by three methods, known as the Composite Reference Method: (1) histological evaluation, (2) culture of the organism, and (3) rapid urease detection test. H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian. RESULTS: 277 patients (63% female) were included in the study. The prevalence of infected subjects was 24.2% in this study cohort. Clinical performance assessed against the Composite Reference Method showed very good agreement (Cohen's kappa = 0.922), with good sensitivity (95.5%) and specificity (97.6%). Reproducibility study results showed total imprecision ranging from 3.1% to 13.9% CV. CONCLUSION: The automated LIAISON® Meridian H. pylori SA assay brings reliable noninvasive testing for H. pylori to the laboratory that is in very good agreement with the current, more invasive biopsy-based methods such as histology, culture, or rapid urease test. The clinical trial identifiers are NCT03060746 (pretherapy) and NCT03060733 (posttherapy).H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian H. pylori infection. Since current assays have variable performance, we assessed the clinical performance of the automated LIAISON® Meridian.


Asunto(s)
Antígenos Bacterianos/análisis , Heces/microbiología , Infecciones por Helicobacter/inmunología , Helicobacter pylori/inmunología , Técnicas para Inmunoenzimas/métodos , Adulto , Anciano , Biopsia , Femenino , Infecciones por Helicobacter/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ureasa , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA