1.
Int J Spine Surg ; 15(5): 890-898, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34551927

RESUMEN

BACKGROUND: This study sought to compare index and adjacent-level biomechanics of cadaveric specimens with mature fusion versus normal spines in intact and acutely fused conditions. METHODS: Eight human cadaveric cervical spines with mature fusion across 1 to 3 levels were studied. Intervertebral angular range of motion (ROM) was determined at fused and adjacent levels during pure moments inducing flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Mature fusion data were compared to data from normal spine specimens tested intact and then with a 1-level anterior plate/graft (fresh fixation). Bone qualities were compared using dual-energy x-ray absorptiometry. RESULTS: Mean bone mineral density was significantly greater in mature fusion spines (0.632 ± 0.239 g/cm2) than in normal spines (0.489 ± 0.195 g/cm2) (P < .001). Mean ROM for levels with mature fusion was 42% (FE), 42% (LB), and 29% (AR) of the mean same-level ROM in freshly fixated specimens (P ≤ .045). The mean adjacent-level ROM in spines with mature fusion was less than in normal spines (matched levels) in all directions, with the greatest difference 1 level below fusion (FE: -38%, P < .001; LB: -42%, P < .001; AR: -49%, P = .001), followed by 1 level above fusion (FE: -23%, P = .04; LB: -22%, P = .07; AR: -28%, P = .02) and 2 levels above fusion (FE: -20%, P = .08; LB: -18%, P = .11; AR: -31%, P = .009). Mature fusion reduced the magnitude of coupled LB during AR at C6-7 and C7-T1 (P ≤ .03). CONCLUSION: Cervical spine segments with mature fusion have higher bone mass, are less flexible than freshly fixed spines, and have reduced mobility at adjacent levels.

2.
Int J Spine Surg ; 13(3): 245-251, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31328088

RESUMEN

BACKGROUND: Information on the performance of posterior fixation with cortical screw (CS) versus pedicle screw (PS) trajectories for stabilizing thoracolumbar burst fractures is limited. Therefore, we sought to analyze stability with CS versus PS in short- and long-segment fixations using a 3-column spinal injury model. METHODS: Nondestructive flexibility tests: (1) intact, (2) intact + short fixation, (3) intact + long fixation, (4) after burst fracture, (5) short fixation + burst fracture, and (6) long fixation + burst fracture using thoracic spine segments (7 CS, 7 PS). RESULTS: With CS, the range of motion (ROM) was significantly greater with short-segment than with long-segment fixation in all directions, with and without burst fracture (P ≤ .008). With PS and burst fracture, ROM was significantly greater with short fixation during lateral bending and axial rotation (P < .006), but not during flexion-extension (P = .10). Groups with CS versus PS were not significantly different after burst fracture during flexion-extension and axial rotation, with short (P ≥ .58) or long fixation (P ≥ .17). During lateral bending, ROM was significantly greater with CS versus PS, without burst fracture (long fixation, P = .02) and with burst fracture (short and long fixation, P ≤ .001). CONCLUSIONS: CS trajectory is a valid alternative to PS trajectory for thoracic spine fixation in 3-column spinal injuries, and long-segment fixation is superior to short-segment fixation with either.

3.
J Neurosurg Spine ; 25(2): 187-92, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27035506

RESUMEN

OBJECTIVE Transvertebral screws provide stability in thoracic spinal fixation surgeries, with their use mainly limited to patients who require a pedicle screw salvage technique. However, the biomechanical impact of transvertebral screws alone, when they are inserted across 2 vertebral bodies, has not been studied. In this study, the authors assessed the stability offered by a transvertebral screw construct for posterior instrumentation and compared its biomechanical performance to that of standard bilateral pedicle screw and rod (PSR) fixation. METHODS Fourteen fresh human cadaveric thoracic spine segments from T-6 to T-11 were divided into 2 groups with similar ages and bone quality. Group 1 received transvertebral screws across 2 levels without rods and subsequently with interconnecting bilateral rods at 3 levels (T8-10). Group 2 received bilateral PSR fixation and were sequentially tested with interconnecting rods at T7-8 and T9-10, at T8-9, and at T8-10. Flexibility tests were performed on intact and instrumented specimens in both groups. Presurgical and postsurgical O-arm 3D images were obtained to verify screw placement. RESULTS The mean range of motion (ROM) per motion segment with transvertebral screws spanning 2 levels compared with the intact condition was 66% of the mean intact ROM during flexion-extension (p = 0.013), 69% during lateral bending (p = 0.015), and 47% during axial rotation (p < 0.001). The mean ROM per motion segment with PSR spanning 2 levels compared with the intact condition was 38% of the mean intact ROM during flexion-extension (p < 0.001), 57% during lateral bending (p = 0.007), and 27% during axial rotation (p < 0.001). Adding bilateral rods to the 3 levels with transvertebral screws decreased the mean ROM per motion segment to 28% of intact ROM during flexion-extension (p < 0.001), 37% during lateral bending (p < 0.001), and 30% during axial rotation (p < 0.001). The mean ROM per motion segment for PSR spanning 3 levels was 21% of intact ROM during flexion-extension (p < 0.001), 33% during lateral bending (p < 0.001), and 22% during axial rotation (p < 0.001). CONCLUSIONS Biomechanically, fixation with a novel technique in the thoracic spine involving transvertebral screws showed restoration of stability to well within the stability provided by PSR fixation.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Vértebras Torácicas/cirugía , Adulto , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Docilidad , Rango del Movimiento Articular , Vértebras Torácicas/diagnóstico por imagen , Vértebras Torácicas/fisiopatología
4.
Spine (Phila Pa 1976) ; 41(2): E55-63, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26335667

RESUMEN

STUDY DESIGN: Nondestructive flexibility tests were performed in vitro, comparing multiple conditions of fixation in a single group of specimens. OBJECTIVE: To compare the biomechanical behavior of the lumbar spine in the intact condition, after implanting a novel motion stabilizer, and after implanting a rigid fixator. SUMMARY OF BACKGROUND DATA: Two specific scenarios that may benefit from dynamic lumbar stabilization are single-level moderate instability, where the stabilizing tissues are relatively incompetent, and juxta-level to fusion, where the last instrumented level requires intermediate stiffness ("topping off") to prevent transfer of high stresses from the stiffer fusion construct to the intact adjacent levels. Both scenarios were evaluated in vitro. METHODS: Seven human cadaveric L2-S1 segments were tested (1) intact, (2) after moderate destabilization, (3) after 2-level hybrid posterior fixation, consisting of bilateral dynamic pedicle screws at L4 interconnected with rigid rods to standard pedicle screws at L5 and S1, (4) after 2-level rigid fixation, (5) after 1-level (L4-L5) dynamic fixation, and (6) after 1-level rigid fixation. In each condition, angular range of motion (ROM) and sagittal instantaneous axis of rotation (IAR) were assessed. RESULTS: In 1-level constructs, dynamic hardware allowed 104% of intact ROM, whereas rigid hardware allowed 49% of intact ROM. Relative to the intact, the IAR was shifted significantly farther posterior by rigid 1-level instrumentation than by dynamic 1-level instrumentation. In 2-level constructs, the dynamic level allowed significantly greater ROM than the rigid level in all directions but allowed significantly less ROM than the intact level in all directions except axial rotation. CONCLUSION: Dynamic instrumentation shifted the IAR less than rigid instrumentation, providing more favorable kinematics. This dynamic stabilizer provided 1-level ROM that was close to intact ROM during all loading modes in vitro. In the topping-off construct, the dynamic segment allowed intermediate ROM to give balanced transitional flexibility. LEVEL OF EVIDENCE: N/A.


Asunto(s)
Tornillos Óseos , Inestabilidad de la Articulación/cirugía , Vértebras Lumbares/cirugía , Fusión Vertebral/instrumentación , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Inestabilidad de la Articulación/fisiopatología , Vértebras Lumbares/fisiopatología , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Rango del Movimiento Articular , Fusión Vertebral/métodos , Estrés Mecánico
5.
J Neurosurg Spine ; 24(2): 340-346, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26460753

RESUMEN

OBJECT The Universal Clamp Spinal Fixation System (UC) is a novel sublaminar connection for the spine that is currently used in conjunction with pedicle screws at the thoracic levels for the correction of scoliosis. This device allows the surgeon to attach rods and incorporate a pedicle screw construction. The flexible composition of the UC should provide flexibility intermediate to the uninstrumented spine and an all-screw construct. This hypothesis was tested in vitro using nondestructive flexibility testing of human cadaveric spine segments. METHODS Six unembalmed human cadaveric thoracic spine segments from T-3 to T-11 were used. The specimens were tested under the following conditions: 1) intact; 2) after bilateral screws were placed at T4-T10 and interconnected with longitudinal rods; 3) after placement of a hybrid construction with screws at T-4, T-7, and T-10 with an interconnecting rod on one side and screws at T-4 and T-10 with the UC at T5-9 on the contralateral side; (4) after bilateral screws were placed at T-4 and T-10 and interconnected with rods and bilateral UC were placed at T5-9; and 5) after bilateral screws at T-4 and T-10 were placed and interconnected with rods and bilateral sublaminar cables were placed at T5-9. Pure moments of 6.0 Nm were applied while optoelectronically recording 3D angular motion. RESULTS Bilateral UC placement and bilateral sublaminar cables both resulted in a significantly greater range of motion than bilateral pedicle screws during lateral bending and axial rotation, but not during flexion or extension. There were no differences in stability between bilateral UC and bilateral cables. The construct with limited screws on one side and UC contralaterally showed comparable stability to bilateral UC and bilateral cables. CONCLUSIONS These results support using the UC as a therapeutic option for spinal stabilization because it allows comparable stability to the sublaminar cables and provides flexibility intermediate to that of the uninstrumented spine and an all-screw construct. Equivalent stability of the hybrid, bilateral UC, and bilateral cable constructs indicates that 6-level UC provides stability comparable to that of a limited (3-point) pedicle screw-rod construct.

6.
J Neurosurg Spine ; 24(4): 615-23, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26654342

RESUMEN

OBJECT: The effects of obesity on lumbar biomechanics are not fully understood. The aims of this study were to analyze the biomechanical differences between cadaveric L4-5 lumbar spine segments from a large group of nonobese (body mass index [BMI] < 30 kg/m2) and obese (BMI ≥ 30 kg/m2) donors and to determine if there were any radiological differences between spines from nonobese and obese donors using MR imaging. METHODS: A total of 168 intact L4-5 spinal segments (87 males and 81 females) were tested using pure-moment loading, simulating flexion-extension, lateral bending, and axial rotation. Axial compression tests were performed on 38 of the specimens. Sex, age, and BMI were analyzed with biomechanical parameters using 1-way ANOVA, Pearson correlation, and multiple regression analyses. MR images were obtained in 12 specimens (8 from obese and 4 from nonobese donors) using a 3-T MR scanner. RESULTS: The segments from the obese male group allowed significantly greater range of motion (ROM) than those from the nonobese male group during axial rotation (p = 0.018), while there was no difference between segments from obese and nonobese females (p = 0.687). There were no differences in ROM between spines from obese and nonobese donors during flexion-extension or lateral bending for either sex. In the nonobese population, the ROM during axial rotation was significantly greater for females than for males (p = 0.009). There was no significant difference between sexes in the obese population (p = 0.892). Axial compressive stiffness was significantly greater for the obese than the nonobese population for both the female-only group and the entire study group (p < 0.01); however, the difference was nonsignificant in the male population (p = 0.304). Correlation analysis confirmed a significant negative correlation between BMI and resistance to deformation during axial compression in the female group (R = -0.65, p = 0.004), with no relationship in the male group (R = 0.03, p = 0.9). There was also a significant negative correlation between ROM during flexion-extension and BMI for the female group (R = -0.38, p = 0.001), with no relationship for the male group (R = 0.06, p = 0.58). Qualitative analysis using MR imaging indicated greater facet degeneration and a greater incidence of disc herniations in the obese group than in the control group. CONCLUSIONS: Based on flexibility and compression tests, lumbar spinal segments from obese versus nonobese donors seem to behave differently, biomechanically, during axial rotation and compression. The differences are more pronounced in women. MR imaging suggests that these differences may be due to greater facet degeneration and an increased amount of disc herniation in the spines from obese individuals.


Asunto(s)
Desplazamiento del Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Región Lumbosacra/cirugía , Obesidad/complicaciones , Docilidad/fisiología , Rango del Movimiento Articular/fisiología , Adulto , Anciano , Fenómenos Biomecánicos/fisiología , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rotación , Fusión Vertebral/métodos
8.
J Neurosurg Spine ; 22(5): 470-7, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25679235

RESUMEN

OBJECT The primary disadvantage of the posterior cervical approach for atlantoaxial stabilization after odontoidectomy is that it is conducted as a second-stage procedure. The goal of the current study is to assess the surgical feasibility and biomechanical performance of an endoscopic endonasal surgical technique for C1-2 fixation that may eliminate the need for posterior fixation after odontoidectomy. METHODS The first step of the study was to perform endoscopic endonasal anatomical dissections of the craniovertebral junction in 10 silicone-injected fixed cadaveric heads to identify relevant anatomical landmarks. The second step was to perform a quantitative analysis using customized software in 10 reconstructed adult cervical spine CT scans to identify the optimal screw entry point and trajectory. The third step was biomechanical flexibility testing of the construct and comparison with the posterior C1-2 transarticular fixation in 14 human cadaveric specimens. RESULTS Adequate surgical exposure and identification of the key anatomical landmarks, such as C1-2 lateral masses, the C-1 anterior arch, and the odontoid process, were provided by the endonasal endoscopic approach in all specimens. Radiological analysis of anatomical detail suggested that the optimal screw entry point was on the anterior aspect of the C-1 lateral mass near the midpoint, and the screw trajectory was inferiorly and slightly laterally directed. The custommade angled instrumentation was crucial for screw placement. Biomechanical analysis suggested that anterior C1-2 fixation compared favorably to posterior fixation by limiting flexion-extension, axial rotation, and lateral bending (p > 0.3). CONCLUSIONS This is the first study that demonstrates the feasibility of an endoscopic endonasal technique for C1-2 fusion. This novel technique may have clinical utility by eliminating the need for a second-stage posterior fixation operation in certain patients undergoing odontoidectomy.


Asunto(s)
Articulación Atlantoaxoidea/cirugía , Tornillos Óseos , Endoscopía , Fusión Vertebral/métodos , Anciano , Anciano de 80 o más Años , Articulación Atlantoaxoidea/diagnóstico por imagen , Fenómenos Biomecánicos , Cadáver , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nariz , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Tomografía Computarizada por Rayos X
9.
J Neurosurg Spine ; 18(4): 327-32, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23414005

RESUMEN

OBJECT: Endoscopic endonasal approaches to the craniovertebral junction (CVJ) and clivus are increasingly performed for ventral skull-base pathology, but the biomechanical implications of these approaches have not been studied. The aim of this study was to investigate the spinal biomechanics of the CVJ after an inferior-third clivectomy and anterior intradural exposure of the foramen magnum as would be performed in an endonasal endoscopic surgical strategy. METHODS: Seven upper-cervical human cadaveric specimens (occiput [Oc]-C2) underwent nondestructive biomechanical flexibility testing during flexion-extension, axial rotation, and lateral bending at Oc-C1 and C1-2. Each specimen was tested intact, after an inferior-third clivectomy, and after ligamentous complex dissection simulating a wide intradural exposure using an anterior approach. Angular range of motion (ROM), lax zone, and stiff zone were determined and compared with the intact state. RESULTS: Modest, but statistically significant, hypermobility was observed after inferior-third clivectomy and intradural exposure during flexion-extension and axial rotation at Oc-C1. Angular ROM increased incrementally between 6% and 12% in flexion-extension and axial rotation. These increases were primarily the result of changes in the lax zone. No significant changes were noted at C1-2. CONCLUSIONS: Inferior-third clivectomy and an intradural exposure to the ventral CVJ and foramen magnum resulted in hypermobility at Oc-C1 during flexion-extension and axial rotation. Although the results were statistically significant, the modest degree of hypermobility observed compared with other well-characterized CVJ injuries suggests that occipitocervical stabilization may be unnecessary for most patients.


Asunto(s)
Fenómenos Biomecánicos/fisiología , Vértebras Cervicales/cirugía , Fosa Craneal Posterior/cirugía , Endoscopía/métodos , Nariz/cirugía , Base del Cráneo/cirugía , Adulto , Vértebras Cervicales/fisiología , Fosa Craneal Posterior/fisiología , Femenino , Foramen Magno/cirugía , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular/fisiología , Base del Cráneo/fisiología , Adulto Joven