Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
J Tissue Eng Regen Med ; 12(2): e1076-e1087, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28382727

RESUMEN

The production of human induced pluripotent stem cells (hiPSCs) in quantities that are relevant for cell-based therapies and cell-loaded implants through standard adherent culture is hardly achievable and lacks process scalability. A promising approach to overcoming these hurdles is the culture of hiPSCs in suspension. In this study, stirred suspension culture vessels were investigated for their suitability in the expansion of two hiPSC lines inoculated as a single cell suspension, with a free scalability between volumes of 50 and 2400 ml. The simple and robust two-step process reported here first generates hiPSC aggregates of 324 ± 71 µm diameter in 7 days in 125 ml spinner flasks (100 ml volume). These are subsequently dissociated into a single cell suspension for inoculation in 3000 ml bioreactors (1000 ml volume), finally yielding hiPSC aggregates of 198 ± 58 µm after 7 additional days. In both spinner flasks and bioreactors, hiPSCs can be cultured as aggregates for more than 40 days in suspension, maintain an undifferentiated state as confirmed by the expression of pluripotency markers TRA-1-60, TRA-1-81, SSEA-4, OCT4, and SOX2, can differentiate into cells of all three germ layers, and can be directed to differentiate into specific lineages such as cardiomyocytes. Up to a 16-fold increase in hiPSC quantity at the 100 ml volume was achieved, corresponding to a fold increase per day of 2.28; at the 1000 ml scale, an additional 10-fold increase was achieved. Taken together, 16 × 106 hiPSCs were expanded into 2 × 109 hiPSCs in 14 days for a fold increase per day of 8.93. This quantity of hiPSCs readily meets the requirements of cell-based therapies and brings their clinical potential closer to fruition.


Asunto(s)
Reactores Biológicos , Técnicas de Cultivo de Célula/instrumentación , Células Madre Pluripotentes Inducidas/citología , Adulto , Biomarcadores/metabolismo , Adhesión Celular , Agregación Celular , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Humanos , Células Madre Pluripotentes Inducidas/metabolismo , Cariotipo , Masculino , Células Madre Pluripotentes/citología , Células Madre Pluripotentes/metabolismo , Estándares de Referencia , Suspensiones , Adulto Joven
3.
Anal Chim Acta ; 781: 54-62, 2013 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-23684465

RESUMEN

In this paper we report a centrifugal microfluidic "lab-on-a-disc" system for at-line monitoring of human immunoglobulin G (hIgG) in a typical bioprocess environment. The novelty of this device is the combination of a heterogeneous sandwich immunoassay on a serial siphon-enabled microfluidic disc with automated sequential reagent delivery and surface-confined supercritical angle fluorescence (SAF)-based detection. The device, which is compact, easy-to-use and inexpensive, enables rapid detection of hIgG from a bioprocess sample. This was achieved with, an injection moulded SAF lens that was functionalized with aminopropyltriethoxysilane (APTES) using plasma enhanced chemical vapour deposition (PECVD) for the immobilization of protein A, and a hybrid integration with a microfluidic disc substrate. Advanced flow control, including the time-sequenced release of on-board liquid reagents, was implemented by serial siphoning with ancillary capillary stops. The concentration of surfactant in each assay reagent was optimized to ensure proper functioning of the siphon-based flow control. The entire automated microfluidic assay process is completed in less than 30 min. The developed prototype system was used to accurately measure industrial bioprocess samples that contained 10 mg mL(-1) of hIgG.


Asunto(s)
Inmunoensayo/instrumentación , Inmunoensayo/métodos , Inmunoglobulina G/análisis , Técnicas Analíticas Microfluídicas/instrumentación , Calibración , Centrifugación/instrumentación , Diseño de Equipo , Fluorescencia , Humanos , Sistemas Microelectromecánicos , Óptica y Fotónica/instrumentación , Propilaminas , Silanos/química
4.
Lab Chip ; 12(16): 2894-902, 2012 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-22692574

RESUMEN

In this article we introduce a novel technology that utilizes specialized water dissolvable thin films for valving in centrifugal microfluidic systems. In previous work (William Meathrel and Cathy Moritz, IVD Technologies, 2007), dissolvable films (DFs) have been assembled in laminar flow devices to form efficient sacrificial valves where DFs simply open by direct contact with liquid. Here, we build on the original DF valving scheme to leverage sophisticated, merely rotationally actuated vapour barriers and flow control for enabling comprehensive assay integration with low-complexity instrumentation on "lab-on-a-disc" platforms. The advanced sacrificial valving function is achieved by creating an inverted gas-liquid stack upstream of the DF during priming of the system. At low rotational speeds, a pocket of trapped air prevents a surface-tension stabilized liquid plug from wetting the DF membrane. However, high-speed rotation disrupts the metastable gas/liquid interface to wet the DF and thus opens the valve. By judicious choice of the radial position and geometry of the valve, the burst frequency can be tuned over a wide range of rotational speeds nearly 10 times greater than those attained by common capillary burst valves based on hydrophobic constrictions. The broad range of reproducible burst frequencies of the DF valves bears the potential for full integration and automation of comprehensive, multi-step biochemical assay protocols. In this report we demonstrate DF valving, discuss the biocompatibility of using the films, and show a potential sequential valving system including the on-demand release of on-board stored liquid reagents, fast centrifugal sedimentation and vigorous mixing; thus providing a viable basis for use in lab-on-a-disc platforms for point-of-care diagnostics and other life science applications.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Centrifugación , Diseño de Equipo , Gases/química , Interacciones Hidrofóbicas e Hidrofílicas
5.
Genome Res ; 14(11): 2357-66, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15520297

RESUMEN

Despite recent advances in linear whole genome amplification of intact DNA/RNA, amplification of degraded nucleic acids in an unbiased fashion remains a serious challenge for genetic diagnosis. We describe a new whole genome amplification procedure, RCA-RCA (Restriction and Circularization-Aided Rolling Circle Amplification), which retains the allelic differences among degraded amplified genomes while achieving almost complete genome coverage. RCA-RCA utilizes restriction digestion and whole genome circularization to generate genomic sequences amenable to rolling circle amplification. When intact genomic DNA is used, RCA-RCA retains gene-amplification differences (twofold or higher) between complex genomes on a genome-wide scale providing highly improved concordance with unamplified material as compared with other amplification methodologies including multiple displacement amplification. Using RCA-RCA, formalin-fixed samples of modest or substantial DNA degradation were successfully amplified and screened via array-CGH or Taqman PCR that displayed retention of the principal gene amplification features of the original material. Microsatellite analysis revealed that RCA-RCA amplified genomic DNA is representative of the original material at the nucleotide level. Amplification of cDNA is successfully performed via RCA-RCA and results to unbiased gene expression analysis (R(2) = 0.99). The simplicity and universal applicability of RCA-RCA make it a powerful new tool for genome analysis with unique advantages over previous amplification technologies.


Asunto(s)
ADN Circular/análisis , ADN de Neoplasias/análisis , Genoma , Técnicas de Amplificación de Ácido Nucleico/métodos , Línea Celular Tumoral , Técnicas de Laboratorio Clínico , Cartilla de ADN , Perfilación de la Expresión Génica , Genotipo , Humanos , Repeticiones de Microsatélite , Técnicas de Sonda Molecular , Análisis de Secuencia por Matrices de Oligonucleótidos , Manejo de Especímenes
6.
Nucleic Acids Res ; 32(9): e76, 2004 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-15155823

RESUMEN

Analysis of genomic DNA derived from cells and fresh or fixed tissues often requires whole genome amplification prior to microarray screening. Technical hurdles to this process are the introduction of amplification bias and/or the inhibitory effects of formalin fixation on DNA amplification. Here we demonstrate a balanced-PCR procedure that allows unbiased amplification of genomic DNA from fresh or modestly degraded paraffin-embedded DNA samples. Following digestion and ligation of a target and a control genome with distinct linkers, the two are mixed and amplified in a single PCR, thereby avoiding biases associated with PCR saturation and impurities. We demonstrate genome-wide retention of allelic differences following balanced-PCR amplification of DNA from breast cancer and normal human cells and genomic profiling by array-CGH (cDNA arrays, 100 kb resolution) and by real-time PCR (single gene resolution). Comparison of balanced-PCR with multiple displacement amplification (MDA) demonstrates equivalent performance between the two when intact genomic DNA is used. When DNA from paraffin-embedded samples is used, balanced PCR overcomes problems associated with modest DNA degradation and produces unbiased amplification whereas MDA does not. Balanced-PCR allows amplification and recovery of modestly degraded genomic DNA for subsequent retrospective analysis of human tumors with known outcomes.


Asunto(s)
ADN/análisis , Dosificación de Gen , Genoma Humano , Genómica/métodos , Reacción en Cadena de la Polimerasa/métodos , Artefactos , Secuencia de Bases , Línea Celular , Línea Celular Tumoral , Deleción Cromosómica , ADN/genética , ADN/metabolismo , Cartilla de ADN/genética , Femenino , Formaldehído , Perfilación de la Expresión Génica/métodos , Humanos , Hibridación de Ácido Nucleico , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Adhesión en Parafina , Reacción en Cadena de la Polimerasa/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo , Fijación del Tejido
7.
Am J Pathol ; 164(1): 23-33, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-14695315

RESUMEN

Genome-wide screening of genetic alterations between normal and cancer cells, as well as among subgroups of tumors, is important for establishing molecular mechanism and classification of cancer. Gene silencing through loss of heterozygosity is widely observed in cancer cells and detectable by analyzing allelic loss of single nucleotide polymorphism and/or short tandem repeat markers. To use minute quantities of DNA that are available through laser capture microdissection (LCM) of cancer cells, a whole genome amplification method that maintains locus and allele balance is essential. We have successfully used a ø29 polymerase-based isothermal whole genome amplification method to amplify LCM DNA using a proteinase K lysis procedure coupled with a pooling strategy. Through single nucleotide polymorphism and short tandem repeat genotype analysis we demonstrate that using pooled DNA from two or three separate amplification reactions significantly reduces any allele bias introduced during amplification. This strategy is especially effective when using small quantities of source DNA. Although a convenient alkaline lysis DNA extraction procedure provided satisfactory results from using 1500 to 3000 LCM cells, proteinase K digestion was superior for lower cell numbers. Accurate genotyping is achieved with as few as 100 cells when both proteinase K extraction and pooling are applied.


Asunto(s)
Técnicas de Amplificación de Ácido Nucleico/métodos , Polimorfismo de Nucleótido Simple/genética , Secuencias Repetidas en Tándem/genética , Femenino , Genotipo , Humanos , Rayos Láser , Masculino , Microdisección , Reacción en Cadena de la Polimerasa , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...