Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Obstet Gynaecol India ; 70(3): 208-213, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32476767

RESUMEN

KEY MESSAGE: The new NB scope aids in better visualization of the scalp and blood collection and analysis at bed side. OBJECTIVE: Caesarean section rates and inherent complications are on the rise all over the world. One way to avoid a caesarean is to measure fetal scalp blood lactate levels. The methods available to visualize fetal scalp, obtain the blood sample and perform the blood test are separate, cumbersome and expensive, needing a certain level of expertise. We propose a device that incorporates all the steps of obtaining a fetal scalp blood lactate into one sleek, easy to use device. METHODS: The initial design, 3-D print and was tried on mannequin. After ethics committee approval, the prototype was experimented on patients in labour with singleton live fetus in cephalic presentation with no evidence of distress. RESULTS: There were (n = 9) patients recruited. There were (n = 5) primigravida and (n = 4) multigravida all of whom were in active labour. Parity did not seem to influence ease of instrumentation. Of the (n = 9) mothers (n = 2) had meconium-stained liquor and the rest (n = 7) had clear liquor, meconium-stained liquor did not affect visualization. The mean time taken to collect the sample was 184.11(± 33.04) seconds. CONCLUSION: The Neeraj-Bhaskar (NB) scope is an easy to use, affordable device that can be used time and again to decide on cases where emergency caesarean section can be avoided due to fetal distress.

2.
J Turk Ger Gynecol Assoc ; 20(2): 106-116, 2019 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-30362339

RESUMEN

Objective: To determine the stillbirth rate in 2017 at Christian Medical College, a tertiary care perinatal center in South India, and to identify causes for the various stillbirths that occurred using the Relevant Condition at Death (ReCoDe) classification. Material and Methods: Medical records of the women with stillbirths between January 1st, to December 31st, 2017, were retrieved and analyzed using the SPSS software (IBM, version 23). The study was approved by the institutional review board (minute no: 11273, retro dated: 28/3/2018). Results: Of the total 14696 deliveries between January 1st, 2017, to December 31st, 2017, there were 247 stillbirths, a rate of 16.8 per 1000 births. Maternal factors: 156 (64.2%) women were booked and the rest were un-booked. Hypertensive disorders of pregnancy were detected in 27.5% (n=67). A greater number of un-booked women had gestational hypertension as compared with booked women (41% vs 24%, p=0.005). Fetal characteristics: still births secondary to lethal congenital anomalies were seen in 18.2% (n=45). Lethal congenital anomalies were diagnosed 10 times more in the booked patients than un-booked ones (24.7% vs 2.3%, p=0.001). Obstetric factors: one or two previous miscarriages were seen in 29.5% cases. Seventeen women (6.9%) had a prior stillbirth. ReCoDe Classification: we were able to successfully classify 84.2% of the stillbirths, leaving 15.78% unclassified. Fetal growth restriction secondary to uteroplacental insufficiency was found in 25.9% cases. Of the placental causes, abruption accounted for 10.9% of cases. Medical co-morbidities were seen in 46.5% pregnancies. Conclusion: The ReCoDe method of classifying stillbirths is useful in the developing world. It helped to elucidate the cause for stillbirths in 84.2% of cases. The majority of cases in our set were due to fetal growth restriction, hypertensive disorders of pregnancy, and uteroplacental insufficiency. Stillbirths can be prevented by a comprehensive antenatal care system, early recognition, and close monitoring of high-risk pregnancies.

3.
Trop Doct ; 47(4): 312-316, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28409530

RESUMEN

An assessment of the efficacy and satisfaction of women in active labour having digital cervical stretching compared to women who did not have this intervention. Ours was a randomised controlled trial at a tertiary centre in India. Low-risk women at term with vertex presentation in active labour with ruptured membranes and cervical dilation of 4-6 cm were included. Stretching to delivery interval was 247.5 ± 158.2 min in the intervention group and 265.5 ± 158.4 in the control group. The mode of delivery, incidence of cervical tear, and maternal, fetal and neonatal complications were similar in both groups. The Labour and Delivery Satisfaction Index (LADSI) was similar in both groups. While no significant discomfort was perceived with stretching, it does not appear to expedite labour.


Asunto(s)
Cuello del Útero/fisiología , Dilatación/métodos , Membranas Extraembrionarias/fisiología , Inicio del Trabajo de Parto , Trabajo de Parto Inducido/métodos , Resultado del Embarazo , Adulto , Parto Obstétrico , Femenino , Edad Gestacional , Humanos , India , Embarazo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA