Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Front Pediatr ; 12: 1393321, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39228441

RESUMEN

Background: Understanding the distinct immunologic responses to SARS-CoV-2 infection among pediatric populations is pivotal in navigating the COVID-19 pandemic and informing future public health strategies. This study aimed to identify factors associated with heightened antibody responses in children and adolescents to identify potential unique immune dynamics in this population. Methods: Data collected between July and December 2023 from the Texas Coronavirus Antibody REsponse Survey (Texas CARES), a statewide prospective population-based antibody survey among 1-to-19-year-old participants, were analyzed. Each participant had the following data available for analysis: (1) Roche Elecsys® Anti-SARS-CoV-2 Immunoassay for Nucleocapsid protein antibodies (Roche N-test), (2) qualitative and semi-quantitative detection of antibodies to the SARS CoV-2 spike protein receptor binding domain (Roche S-test), and (3) self-reported antigen/PCR COVID-19 test results, vaccination, and health status. Statistical analysis identified associations between participant characteristics and spike antibody quartile group. Results: The analytical sample consisted of 411 participants (mean age 12.2 years, 50.6% female). Spike antibody values ranged from a low of 6.3 U/ml in the lowest quartile to a maximum of 203,132.0 U/ml in the highest quartile in the aggregate sample. Older age at test date (OR = 1.22, 95% CI: 1.12, 1.35, p < .001) and vaccination status (primary series/partially vaccinated, one or multiple boosters) showed significantly higher odds of being in the highest spike antibody quartile compared to younger age and unvaccinated status. Conversely, fewer days since the last immunity challenge showed decreased odds (OR = 0.98, 95% CI: 0.96, 0.99, p = 0.002) of being in the highest spike antibody quartile vs. more days since last immunity challenge. Additionally, one out of every three COVID-19 infections were asymptomatic. Conclusions: Older age, duration since the last immunity challenge (vaccine or infection), and vaccination status were associated with heightened spike antibody responses, highlighting the nuanced immune dynamics in the pediatric population. A significant proportion of children/adolescents continue to have asymptomatic infection, which has important public health implications.

2.
medRxiv ; 2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39185530

RESUMEN

Postoperative Delirium (POD) is the most common complication following surgery among older adults, and has been consistently associated with increased mortality and morbidity, cognitive decline, and loss of independence, as well as markedly increased health-care costs. The development of new tools to identify individuals at high risk for POD could guide clinical decision-making and enable targeted interventions to potentially decrease delirium incidence and POD-related complications. In this study, we used machine learning techniques to evaluate whether baseline (pre-operative) cognitive function and resting-state electroencephalography could be used to identify patients at risk for POD. Pre-operative resting-state EEGs and the Montreal Cognitive Assessment (MoCA) were collected from 85 patients (age = 73 ± 6.4 years) undergoing elective surgery, 12 of whom subsequently developed POD. The model with the highest f1-score for predicting delirium, a linear-discriminant analysis (LDA) model incorporating MoCA scores and occipital alpha-band EEG features, was subsequently validated in an independent, prospective cohort of 51 older adults (age ≥ 60) undergoing elective surgery, 6 of whom developed POD. The LDA-based model, with a total of 7 features, was able to predict POD with area under the receiver operating characteristic curve, specificity and accuracy all >90%, and sensitivity > 80%, in the validation cohort. Notably, models incorporating both resting-state EEG and MoCA scores outperformed those including either EEG or MoCA alone. While requiring prospective validation in larger cohorts, these results suggest that prediction of POD with high accuracy may be feasible in clinical settings using simple and widely available clinical tools.

3.
Clin Transl Sci ; 17(7): e13897, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39039704

RESUMEN

Today's approach to medicine requires extensive trial and error to determine the proper treatment path for each patient. While many fields have benefited from technological breakthroughs in computer science, such as artificial intelligence (AI), the task of developing effective treatments is actually getting slower and more costly. With the increased availability of rich historical datasets from previous clinical trials and real-world data sources, one can leverage AI models to create holistic forecasts of future health outcomes for an individual patient in the form of an AI-generated digital twin. This could support the rapid evaluation of intervention strategies in silico and could eventually be implemented in clinical practice to make personalized medicine a reality. In this work, we focus on uses for AI-generated digital twins of clinical trial participants and contend that the regulatory outlook for this technology within drug development makes it an ideal setting for the safe application of AI-generated digital twins in healthcare. With continued research and growing regulatory acceptance, this path will serve to increase trust in this technology and provide momentum for the widespread adoption of AI-generated digital twins in clinical practice.


Asunto(s)
Inteligencia Artificial , Ensayos Clínicos como Asunto , Medicina de Precisión , Humanos , Inteligencia Artificial/tendencias , Medicina de Precisión/métodos , Desarrollo de Medicamentos/métodos
4.
Heliyon ; 10(13): e33633, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39040426

RESUMEN

Background: In-utero phthalate exposure was shown to be associated with shortened anogenital distance (AGD) in male newborns, but findings among female are inconsistent. While phthalate exposure among pregnant women in Israel is widespread, no study has examined the association with offspring AGD. The objective of the current study was to investigate the association between maternal phthalates urinary concentration and offspring AGD at time of delivery among a birth cohort in Israel. Methods: We measured spot urinary concentration of monobutyl phthalate (MBP), monobenzyl phthalate (MBzP), mono-2-ethyl-5-carboxypentyl phthalate (MECPP), mono-2-ethyl-5-hydroxyhexylphthalate (MEHHP), mono-2-ethyl-5-oxohexyl phthalate (MEOHP) among women presenting to the delivery room at Shamir Medical Center in Israel. Birthweight, length and AGD were measured in all newborns using a standardized protocol. Each AGD measurement was adjusted to weight (ano-genital index). Confounders included socio-demographic characteristics, comorbidities and obstetrical history. Univariate and multivariate analyses assessed the associations between phthalates, confounders and AGD. Results: Overall, 193 mother and infant were analyzed. All newborns were born at term and had normal Apgar scores. Mean maternal age was 32 ± 4.7 years old. Mean birth weight and pregnancy week were 3183 ± 498 g and 39 ± 1.3, respectively. Median (IQR) urinary phthalate concentration adjusted to creatinine (ug/g) were 3.96 (2.2-6.6), 1.22 (0.7-2), 10.84 (7-20.4), 6.36 (3.3-11.2) and 0.64 (0.4-1.1) for MBP, MBzP, MECPP, MEHHP and MEOHP, respectively. Univariate comparison showed a significant association between higher than median MBzP concentration, higher Ano-Fourchetal index (AFI: 4.4 vs. 4.1, p = 0.037) and Ano-clitoral index (ACI: 11.5 vs. 10.4, p = 0.032) in infants. Total urinary phthalates concentration ≥26.25 µg/g was significantly associated with smaller penile width index (3.5 vs. 3.7, p = 0.022), higher ACI (11.6 vs. 10.3, p = 0.013) and a trend towards significance for higher AFI (4.3 vs. 4.1, p = 0.055). Following multivariate linear regression only PWI remained significantly associated with total phthalate urinary concentration. Conclusions: Maternal urinary phthalates concentration at delivery were not associated with female AGD, but total urinary phthalate concentration were inversely associated with penile width.

5.
bioRxiv ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38853941

RESUMEN

Objective: We currently lack a robust noninvasive method to measure prefrontal excitability in humans. Concurrent TMS and EEG in the prefrontal cortex is usually confounded by artifacts. Here we asked if real-time optimization could reduce artifacts and enhance a TMS-EEG measure of left prefrontal excitability. Methods: This closed-loop optimization procedure adjusts left dlPFC TMS coil location, angle, and intensity in real-time based on the EEG response to TMS. Our outcome measure was the left prefrontal early (20-60 ms) and local TMS-evoked potential (EL-TEP). Results: In 18 healthy participants, this optimization of coil angle and brain target significantly reduced artifacts by 63% and, when combined with an increase in intensity, increased EL-TEP magnitude by 75% compared to a non-optimized approach. Conclusions: Real-time optimization of TMS parameters during dlPFC stimulation can enhance the EL-TEP. Significance: Enhancing our ability to measure prefrontal excitability is important for monitoring pathological states and treatment response.

6.
Clin Neurophysiol ; 164: 138-148, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38865780

RESUMEN

BACKGROUND: Transcranial magnetic stimulation (TMS) to the dorsolateral prefrontal cortex (dlPFC) is an effective treatment for depression, but the neural effects after TMS remains unclear. TMS paired with electroencephalography (TMS-EEG) can causally probe these neural effects. Nonetheless, variability in single pulse TMS-evoked potentials (TEPs) across dlPFC subregions, and potential artifact induced by muscle activation, necessitate detailed mapping for accurate treatment monitoring. OBJECTIVE: To characterize early TEPs anatomically and temporally (20-50 ms) close to the TMS pulse (EL-TEPs), as well as associated muscle artifacts (<20 ms), across the dlPFC. We hypothesized that TMS location and angle influence EL-TEPs, and specifically that conditions with larger muscle artifact may exhibit lower observed EL-TEPs due to over-rejection during preprocessing. Additionally, we sought to determine an optimal group-level TMS target and angle, while investigating the potential benefits of a personalized approach. METHODS: In 16 healthy participants, we applied single-pulse TMS to six targets within the dlPFC at two coil angles and measured EEG responses. RESULTS: Stimulation location significantly influenced observed EL-TEPs, with posterior and medial targets yielding larger EL-TEPs. Regions with high EL-TEP amplitude had less muscle artifact, and vice versa. The best group-level target yielded 102% larger EL-TEP responses compared to other dlPFC targets. Optimal dlPFC target differed across subjects, suggesting that a personalized targeting approach might boost the EL-TEP by an additional 36%. SIGNIFICANCE: EL-TEPs can be probed without significant muscle-related confounds in posterior-medial regions of the dlPFC. The identification of an optimal group-level target and the potential for further refinement through personalized targeting hold significant implications for optimizing depression treatment protocols.


Asunto(s)
Corteza Prefontal Dorsolateral , Electroencefalografía , Estimulación Magnética Transcraneal , Humanos , Masculino , Femenino , Estimulación Magnética Transcraneal/métodos , Adulto , Electroencefalografía/métodos , Corteza Prefontal Dorsolateral/fisiología , Mapeo Encefálico/métodos , Excitabilidad Cortical/fisiología , Adulto Joven , Corteza Prefrontal/fisiología
7.
Sci Rep ; 14(1): 10518, 2024 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-38714827

RESUMEN

Previous work assessing the effect of additive noise on the postural control system has found a positive effect of additive white noise on postural dynamics. This study covers two separate experiments that were run sequentially to better understand how the structure of the additive noise signal affects postural dynamics, while also furthering our knowledge of how the intensity of auditory stimulation of noise may elicit this phenomenon. Across the two experiments, we introduced three auditory noise stimulations of varying structure (white, pink, and brown noise). Experiment 1 presented the stimuli at 35 dB while Experiment 2 was presented at 75 dB. Our findings demonstrate a decrease in variability of the postural control system regardless of the structure of the noise signal presented, but only for high intensity auditory stimulation.


Asunto(s)
Estimulación Acústica , Ruido , Humanos , Femenino , Masculino , Adulto , Adulto Joven , Equilibrio Postural/fisiología , Color , Postura/fisiología , Posición de Pie
8.
PLoS One ; 19(5): e0303420, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739625

RESUMEN

INTRODUCTION: Studies indicate that individuals with chronic conditions and specific baseline characteristics may not mount a robust humoral antibody response to SARS-CoV-2 vaccines. In this paper, we used data from the Texas Coronavirus Antibody REsponse Survey (Texas CARES), a longitudinal state-wide seroprevalence program that has enrolled more than 90,000 participants, to evaluate the role of chronic diseases as the potential risk factors of non-response to SARS-CoV-2 vaccines in a large epidemiologic cohort. METHODS: A participant needed to complete an online survey and a blood draw to test for SARS-CoV-2 circulating plasma antibodies at four-time points spaced at least three months apart. Chronic disease predictors of vaccine non-response are evaluated using logistic regression with non-response as the outcome and each chronic disease + age as the predictors. RESULTS: As of April 24, 2023, 18,240 participants met the inclusion criteria; 0.58% (N = 105) of these are non-responders. Adjusting for age, our results show that participants with self-reported immunocompromised status, kidney disease, cancer, and "other" non-specified comorbidity were 15.43, 5.11, 2.59, and 3.13 times more likely to fail to mount a complete response to a vaccine, respectively. Furthermore, having two or more chronic diseases doubled the prevalence of non-response. CONCLUSION: Consistent with smaller targeted studies, a large epidemiologic cohort bears the same conclusion and demonstrates immunocompromised, cancer, kidney disease, and the number of diseases are associated with vaccine non-response. This study suggests that those individuals, with chronic diseases with the potential to affect their immune system response, may need increased doses or repeated doses of COVID-19 vaccines to develop a protective antibody level.


Asunto(s)
Anticuerpos Antivirales , Vacunas contra la COVID-19 , COVID-19 , SARS-CoV-2 , Humanos , Masculino , Femenino , Vacunas contra la COVID-19/inmunología , Vacunas contra la COVID-19/administración & dosificación , Persona de Mediana Edad , COVID-19/prevención & control , COVID-19/epidemiología , COVID-19/inmunología , Adulto , SARS-CoV-2/inmunología , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , Anciano , Texas/epidemiología , Enfermedad Crónica , Estudios Seroepidemiológicos , Adulto Joven , Factores de Riesgo
9.
Cereb Cortex ; 34(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38596882

RESUMEN

We currently lack a reliable method to probe cortical excitability noninvasively from the human dorsolateral prefrontal cortex (dlPFC). We recently found that the strength of early and local dlPFC transcranial magnetic stimulation (TMS)-evoked potentials (EL-TEPs) varied widely across dlPFC subregions. Despite these differences in response amplitude, reliability at each target is unknown. Here we quantified within-session reliability of dlPFC EL-TEPs after TMS to six left dlPFC subregions in 15 healthy subjects. We evaluated reliability (concordance correlation coefficient [CCC]) across targets, time windows, quantification methods, regions of interest, sensor- vs. source-space, and number of trials. On average, the medial target was most reliable (CCC = 0.78) and the most anterior target was least reliable (CCC = 0.24). However, all targets except the most anterior were reliable (CCC > 0.7) using at least one combination of the analytical parameters tested. Longer (20 to 60 ms) and later (30 to 60 ms) windows increased reliability compared to earlier and shorter windows. Reliable EL-TEPs (CCC up to 0.86) were observed using only 25 TMS trials at a medial dlPFC target. Overall, medial dlPFC targeting, wider windows, and peak-to-peak quantification improved reliability. With careful selection of target and analytic parameters, highly reliable EL-TEPs can be extracted from the dlPFC after only a small number of trials.


Asunto(s)
Electroencefalografía , Estimulación Magnética Transcraneal , Humanos , Estimulación Magnética Transcraneal/métodos , Electroencefalografía/métodos , Corteza Prefontal Dorsolateral , Reproducibilidad de los Resultados , Corteza Prefrontal/fisiología , Potenciales Evocados/fisiología
10.
PLoS One ; 19(3): e0301232, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38547209

RESUMEN

We report a prozone effect in measurement of SARS-CoV-2 spike protein antibody levels from an antibody surveillance program. Briefly, the prozone effect occurs in immunoassays when excessively high antibody concentration disrupts the immune complex formation, resulting in a spuriously low reported result. Following participant inquiries, we observed anomalously low measurement of SARS-CoV-2 spike protein antibody levels using the Roche Elecsys® Anti-SARS-CoV-2 S immunoassay from participants in the Texas Coronavirus Antibody Research survey (Texas CARES), an ongoing prospective, longitudinal antibody surveillance program. In July, 2022, samples were collected from ten participants with anomalously low results for serial dilution studies, and a prozone effect was confirmed. From October, 2022 to March, 2023, serial dilution of samples detected 74 additional cases of prozone out of 1,720 participants' samples. Prozone effect may affect clinical management of at-risk populations repeatedly exposed to SARS-CoV-2 spike protein through multiple immunizations or serial infections, making awareness and mitigation of this issue paramount.


Asunto(s)
COVID-19 , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Humanos , Máscaras , Estudios Prospectivos , Inmunoensayo/métodos , Anticuerpos Antivirales
11.
Nanoscale Adv ; 6(4): 1145-1162, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38356633

RESUMEN

Streptococcus pyogenes is a causative agent for strep throat, impetigo, and more invasive diseases. The main reason for the treatment failure of streptococcal infections is increased antibiotic resistance. In recent years, infectious diseases caused by pyogenic streptococci resistant to multiple antibiotics have been rising with a significant impact on public health and the veterinary industry. The development of antibiotic resistance and the resulting emergence of multidrug-resistant bacteria have become primary threats to the public health system, commonly leading to nosocomial infections. Many researchers have turned their focus to developing alternative classes of antibacterial agent based on various nanomaterials. We have developed an antibiotic-free nanoparticle system inspired by naturally occurring bacteriophages to fight antibiotic-resistant bacteria. Our phage-mimicking nanoparticles (PhaNPs) display structural mimicry of protein-turret distribution on the head structure of bacteriophages. By mimicking phages, we can take advantage of their evolutionary constant shape and high antibacterial activity while avoiding the immune reactions of the human body experienced by biologically derived phages. We describe the synthesis of hierarchically arranged core-shell nanoparticles, with a silica core conjugated with silver-coated gold nanospheres to which we have chemisorbed the synthetic antimicrobial peptide Syn-71 on the PhaNPs surface, and increased the rapidity of the antibacterial activity of the nanoparticles (PhaNP@Syn71). The antibacterial effect of the PhaNP@Syn71 was tested in vitro and in vivo in mouse wound infection models. In vitro, results showed a dose-dependent complete inhibition of bacterial growth (>99.99%). Cytocompatibility testing on HaCaT human skin keratinocytes showed minimal cytotoxicity of PhaNP@Syn71, being comparable to the vehicle cytotoxicity levels even at higher concentrations, thus proving that our design is biocompatible with human cells. There was a minimum cutoff dosage above which there was no evolution of resistance after prolonged exposure to sub-MIC dosages of PhaNP@Syn71. Application of PhaNP@Syn71 to a mouse wound infection model exhibited high biocompatibility in vivo while showing immediate stabilization of the wound size, and infection free wound healing. Our results suggest the robust utility of antimicrobial peptide-conjugated phage-mimicking nanoparticles as a highly effective antibacterial system that can combat bacterial infections consistently while avoiding the emergence of resistant bacterial strains.

12.
Sci Rep ; 13(1): 22700, 2023 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-38123591

RESUMEN

How does a train of TMS pulses modify neural activity in humans? Despite adoption of repetitive TMS (rTMS) for the treatment of neuropsychiatric disorders, we still do not understand how rTMS changes the human brain. This limited understanding stems in part from a lack of methods for noninvasively measuring the neural effects of a single TMS train-a fundamental building block of treatment-as well as the cumulative effects of consecutive TMS trains. Gaining this understanding would provide foundational knowledge to guide the next generation of treatments. Here, to overcome this limitation, we developed methods to noninvasively measure causal and acute changes in cortical excitability and evaluated this neural response to single and sequential TMS trains. In 16 healthy adults, standard 10 Hz trains were applied to the dorsolateral prefrontal cortex in a randomized, sham-controlled, event-related design and changes were assessed based on the TMS-evoked potential (TEP), a measure of cortical excitability. We hypothesized that single TMS trains would induce changes in the local TEP amplitude and that those changes would accumulate across sequential trains, but primary analyses did not indicate evidence in support of either of these hypotheses. Exploratory analyses demonstrated non-local neural changes in sensor and source space and local neural changes in phase and source space. Together these results suggest that single and sequential TMS trains may not be sufficient to modulate local cortical excitability indexed by typical TEP amplitude metrics but may cause neural changes that can be detected outside the stimulation area or using phase or source space metrics. This work should be contextualized as methods development for the monitoring of transient noninvasive neural changes during rTMS and contributes to a growing understanding of the neural effects of rTMS.


Asunto(s)
Corteza Motora , Adulto , Humanos , Encéfalo , Mapeo Encefálico/métodos , Potenciales Evocados/fisiología , Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Corteza Prefrontal , Estimulación Magnética Transcraneal/métodos
14.
Sci Rep ; 13(1): 18898, 2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37919322

RESUMEN

Theta burst stimulation (TBS) is a form of repetitive transcranial magnetic stimulation designed to induce changes of cortical excitability that outlast the period of TBS application. In this study, we explored the effects of continuous TBS (cTBS) and intermittent TBS (iTBS) versus sham TBS stimulation, applied to the left primary motor cortex, on modulation of resting state electroencephalography (rsEEG) power. We first conducted hypothesis-driven region-of-interest (ROI) analyses examining changes in alpha (8-12 Hz) and beta (13-21 Hz) bands over the left and right motor cortex. Additionally, we performed data-driven whole-brain analyses across a wide range of frequencies (1-50 Hz) and all electrodes. Finally, we assessed the reliability of TBS effects across two sessions approximately 1 month apart. None of the protocols produced significant group-level effects in the ROI. Whole-brain analysis revealed that cTBS significantly enhanced relative power between 19 and 43 Hz over multiple sites in both hemispheres. However, these results were not reliable across visits. There were no significant differences between EEG modulation by active and sham TBS protocols. Between-visit reliability of TBS-induced neuromodulatory effects was generally low-to-moderate. We discuss confounding factors and potential approaches for improving the reliability of TBS-induced rsEEG modulation.


Asunto(s)
Corteza Motora , Electroencefalografía , Potenciales Evocados Motores/fisiología , Corteza Motora/fisiología , Reproducibilidad de los Resultados , Ritmo Teta/fisiología , Estimulación Magnética Transcraneal/métodos , Humanos
15.
Pediatr Res ; 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37875728

RESUMEN

BACKGROUND: This analysis examined the durability of antibodies present after SARS-CoV-2 infection and vaccination in children and adolescents. METHODS: Data were collected over 4 time points between October 2020-November 2022 as part of a prospective population-based cohort aged 5-to-19 years (N = 810). Results of the (1) Roche Elecsys® Anti-SARS-CoV-2 Immunoassay for detection of antibodies to the SARS-CoV-2 nucleocapsid protein (Roche N-test); and (2) qualitative and semi-quantitative detection of antibodies to the SARS CoV-2 spike protein receptor binding domain (Roche S-test); and (3) self-reported antigen/PCR COVID-19 test results, vaccination and symptom status were analyzed. RESULTS: N antibody levels reached a median of 84.10 U/ml (IQR: 20.2, 157.7) cutoff index (COI) ~ 6 months post-infection and increased slightly to a median of 85.25 (IQR: 28.0, 143.0) COI at 12 months post-infection. Peak S antibody levels were reached at a median of 2500 U/mL ~6 months post-vaccination and remained for ~12 months (mean 11.6 months, SD 1.20). CONCLUSIONS: This analysis provides evidence of robust durability of nucleocapsid and spike antibodies in a large pediatric sample up to 12 months post-infection/vaccination. This information can inform pediatric SARS-CoV-2 vaccination schedules. IMPACT: This study provided evidence of robust durability of both nucleocapsid and spike antibodies in a large pediatric sample up to 12 months after infection. Little is known about the long-term durability of natural and vaccine-induced SARS-CoV-2 antibodies in the pediatric population. Here, we determined the durability of anti-SARS-CoV-2 spike (S-test) and nucleocapsid protein (N-test) in children/adolescents after SARS-CoV-2 infection and/or vaccination lasts at least up to 12 months. This information can inform future SARS-CoV-2 vaccination schedules in this age group.

16.
Front Psychol ; 14: 1271795, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37663342

RESUMEN

[This corrects the article DOI: 10.3389/fpsyg.2023.1124171.].

17.
bioRxiv ; 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37732239

RESUMEN

Background: We currently lack a robust and reliable method to probe cortical excitability noninvasively from the human dorsolateral prefrontal cortex (dlPFC), a region heavily implicated in psychiatric disorders. We recently found that the strength of early and local dlPFC single pulse transcranial magnetic stimulation (TMS)-evoked potentials (EL-TEPs) varied widely depending on the anatomical subregion probed, with more medial regions eliciting stronger responses than anterolateral sites. Despite these differences in amplitude of response, the reliability at each target is not known. Objective: To evaluate the reliability of EL-TEPs across the dlPFC. Methods: In 15 healthy subjects, we quantified within-session reliability of dlPFC EL-TEPs after single pulse TMS to six dlPFC subregions. We evaluated the concordance correlation coefficient (CCC) across targets and analytical parameters including time window, quantification method, region of interest, sensor-vs. source-space, and number of trials. Results: At least one target in the anterior and posterior dlPFC produced reliable EL-TEPs (CCC>0.7). The medial target was most reliable (CCC = 0.78) and the most anterior target was least reliable (CCC = 0.24). ROI size and type (sensor vs. source space) did not affect reliability. Longer (20-60 ms, CCC = 0.62) and later (30-60 ms, CCC = 0.61) time windows resulted in higher reliability compared to earlier and shorter (20-40 ms, CCC 0.43; 20-50 ms, CCC = 0.55) time windows. Peak-to-peak quantification resulted in higher reliability than the mean of the absolute amplitude. Reliable EL-TEPs (CCC up to 0.86) were observed using only 25 TMS trials for a medial dlPFC target. Conclusions: Medial TMS location, wider time window (20-60ms), and peak-to-peak quantification improved reliability. Highly reliable EL-TEPs can be extracted from dlPFC after only a small number of trials. Highlights: Medial dlPFC target improved EL-TEP reliability compared to anterior targets.After optimizing analytical parameters, at least one anterior and one posterior target was reliable (CCC>0.7).Longer (20-60 ms) and later (30-60 ms) time windows were more reliable than earlier and shorter (20-40 ms or 20-50 ms) latencies.Peak-to-peak quantification resulted in higher reliability compared to the mean of the absolute amplitude.As low as 25 trials can yield reliable EL-TEPs from the dlPFC.

18.
Soc Sci Med ; 332: 116104, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37517313

RESUMEN

BACKGROUND: Most research on discrimination and health operationalizes discrimination as direct individual experiences. Here, we examine the social patterning of vicarious discrimination, an important but largely overlooked dimension of discrimination. METHODS: Drawing on community-based participatory research with a multi-stage probability sample (n = 178) of African Americans in Tallahassee, Florida, we measured vicarious discrimination, or exposure to discrimination through one's family and friends. We used chi-square tests to examine gender differences in the social domains and relational sources of vicarious discrimination. Negative binomial regression models were fit to identify predictors of exposure to vicarious discrimination. RESULTS: Vicarious discrimination is more prevalent than direct experiences of discrimination (73 versus 61%) and more than 20% of participants report vicarious discrimination in the absence of direct discrimination. For women, vicarious discrimination most often involved the workplace; for men, police. However, gender differences are smaller for vicarious versus direct discrimination. Close friends and children were top relational sources of vicarious discrimination for men and women, respectively. Middle-aged participants reported the most vicarious discrimination. CONCLUSIONS: Overall, our data show that vicarious discrimination is more common than widely understood and associated with individual-level sociodemographic characteristics that index one's position in broader social systems. The prevalence of vicarious discrimination in the absence of direct discrimination suggests that standard approaches, which measure individual exposures in isolation, are subject to misclassification bias. Our results imply that existing research on discrimination and health, which already demonstrates substantial harm, underestimates African Americans' true exposures to salient aspects of discrimination.

19.
Front Psychol ; 14: 1124171, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37359877

RESUMEN

Self-regulation research highlights the performance trade-offs of different motivational states. For instance, within the context of regulatory focus theory, promotion motivation enhances performance on eager tasks and prevention motivation enhances performance on vigilant tasks (i.e., regulatory focus task-motivation fit). Work on metamotivation-people's understanding and regulation of their motivational states-reveals that, on average, people demonstrate knowledge of how to create such task-motivation fit; at the same time, there is substantial variability in this normative accuracy. The present research examines whether having accurate normative metamotivational knowledge predicts performance. Results revealed that more accurate metamotivational knowledge predicts better performance on brief, single-shot tasks (Study 1) and in a consequential setting (course grades; Study 2). The effect was more robust in Study 2; potential implications of this variability are discussed for understanding when and why knowledge may be associated with performance.

20.
bioRxiv ; 2023 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-37215043

RESUMEN

Theta burst stimulation (TBS) is a form of repetitive transcranial magnetic stimulation designed to induce changes of cortical excitability that outlast the period of TBS application. In this study, we explored the effects of continuous TBS (cTBS) and intermittent TBS (iTBS) versus sham TBS stimulation, applied to the primary motor cortex, on modulation of resting state electroencephalography (rsEEG) power. We first conducted hypothesis-driven region-of-interest (ROI) analyses examining changes in alpha (8-12 Hz) and beta (13-21 Hz) bands over the left and right motor cortex. Additionally, we performed data-driven whole-brain analyses across a wide range of frequencies (1-50 Hz) and all electrodes. Finally, we assessed the reliability of TBS effects across two sessions approximately 1 month apart. None of the protocols produced significant group-level effects in the ROI. Whole-brain analysis revealed that cTBS significantly enhanced relative power between 19-43 Hz over multiple sites in both hemispheres. However, these results were not reliable across visits. There were no significant differences between EEG modulation by active and sham TBS protocols. Between-visit reliability of TBS-induced neuromodulatory effects was generally low-to-moderate. We discuss confounding factors and potential approaches for improving the reliability of TBS-induced rsEEG modulation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA