Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Total Environ ; 950: 175190, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39094638

RESUMEN

Lead ions are especially harmful to human health, causing significant developmental and behavioral abnormalities even at small concentrations. In real-life samples, lead ions are present in mixtures with other metal ions, creating a challenge to detect it selectively at low quantities. To address these challenges, we prepared an electrochemical sensor based on delaminated Ti3C2Tx MXene, which can selectively detect low concentrations of Pb2+ in a solution containing other common metal ions. Cyclic voltammetry was applied as an electrochemical detection method. The proposed reaction mechanism involves a reversible transition between Pb2+ ions and PbO at the MXene-based layer. The sensitivity of the sensor towards Pb2+ ions and a limit of detection were determined. The sensor, as prepared, had a linear response range within 0.15-1.0 µM, with a sensitivity of 26.7 µA/µM and LOD value of 48.7 nM, which meets the requirements set by the World Health Organization.

2.
Int J Mol Sci ; 23(12)2022 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-35743208

RESUMEN

The serologic diagnosis of coronavirus disease 2019 (COVID-19) and the evaluation of vaccination effectiveness are identified by the presence of antibodies specific to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this paper, we present the electrochemical-based biosensing technique for the detection of antibodies specific to the SARS-CoV-2 proteins. Recombinant SARS-CoV-2 spike proteins (rSpike) were immobilised on the surface of a gold electrode modified by a self-assembled monolayer (SAM). This modified electrode was used as a sensitive element for the detection of polyclonal mouse antibodies against the rSpike (anti-rSpike). Electrochemical impedance spectroscopy (EIS) was used to observe the formation of immunocomplexes while cyclic voltammetry (CV) was used for additional analysis of the surface modifications. It was revealed that the impedimetric method and the elaborate experimental conditions are appropriate for the further development of electrochemical biosensors for the serological diagnosis of COVID-19 and/or the confirmation of successful vaccination against SARS-CoV-2.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Animales , Anticuerpos , Técnicas Biosensibles/métodos , COVID-19/diagnóstico , Técnicas Electroquímicas/métodos , Humanos , Ratones , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus
3.
Int J Mol Sci ; 24(1)2022 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-36614164

RESUMEN

In this article, we report the development of an electrochemical biosensor for the determination of the SARS-CoV-2 spike protein (rS). A gold disc electrode was electrochemically modified to form the nanocrystalline gold structure on the surface. Then, it was further altered by a self-assembling monolayer based on a mixture of two alkane thiols: 11-mercaptoundecanoic acid (11-MUA) and 6-mercapto-1-hexanol (6-MCOH) (SAMmix). After activating carboxyl groups using a N-(3-dimethylaminopropyl)-N'-ethyl-carbodiimide hydrochloride and N-hydroxysuccinimide mixture, the rS protein was covalently immobilized on the top of the SAMmix. This electrode was used to design an electrochemical sensor suitable for determining antibodies against the SARS-CoV-2 rS protein (anti-rS). We assessed the association between the immobilized rS protein and the anti-rS antibody present in the blood serum of a SARS-CoV-2 infected person using three electrochemical methods: cyclic voltammetry, differential pulse voltammetry, and potential pulsed amperometry. The results demonstrated that differential pulse voltammetry and potential pulsed amperometry measurements displayed similar sensitivity. In contrast, the measurements performed by cyclic voltammetry suggest that this method is the most sensitive out of the three methods applied in this research.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Humanos , Glicoproteína de la Espiga del Coronavirus , SARS-CoV-2 , Anticuerpos , Electrodos , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Oro/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA