1 - 13 de 13
1.
ERJ Open Res ; 10(3)2024 May.
Article En | MEDLINE | ID: mdl-38770004

Background: The SARS-CoV-2 pandemic stimulated the advancement and research in the field of canine scent detection of COVID-19 and volatile organic compound (VOC) breath sampling. It remains unclear which VOCs are associated with positive canine alerts. This study aimed to confirm that the training aids used for COVID-19 canine scent detection were indeed releasing discriminant COVID-19 VOCs detectable and identifiable by gas chromatography (GC-MS). Methods: Inexperienced dogs (two Labradors and one English Springer Spaniel) were trained over 19 weeks to discriminate between COVID-19 infected and uninfected individuals and then independently validated. Getxent tubes, impregnated with the odours from clinical gargle samples, used during the canines' maintenance training process were also analysed using GC-MS. Results: Three dogs were successfully trained to detect COVID-19. A principal components analysis model was created and confirmed the ability to discriminate between VOCs from positive and negative COVID-19 Getxent tubes with a sensitivity of 78% and a specificity of 77%. Two VOCs were found to be very predictive of positive COVID-19 cases. When comparing the dogs with GC-MS, F1 and Matthew's correlation coefficient, correlation scores of 0.69 and 0.37 were observed, respectively, demonstrating good concordance between the two methods. Interpretation: This study provides analytical confirmation that canine training aids can be safely and reliably produced with good discrimination between positive samples and negative controls. It is also a further step towards better understanding of canine odour discrimination of COVID-19 as the scent of interest and defining what VOC elements the canines interpret as "essential".

2.
EBioMedicine ; 92: 104584, 2023 Jun.
Article En | MEDLINE | ID: mdl-37121096

BACKGROUND: From a public health perspective, the identification of individuals with mild respiratory symptoms due to SARS-CoV-2 infection is important to contain the spread of the disease. The objective of this study was to identify volatile organic compounds (VOCs) in exhaled breath common to infection with different variants of the SARS-CoV-2 virus to inform the development of a point-of-care breath test to detect infected individuals with mild symptoms. METHODS: A prospective, real-world, observational study was conducted on mildly symptomatic out-patients presenting to community test-sites for RT-qPCR SARS-CoV-2 testing when the Alpha, Beta, and Delta variants were driving the COVID-19 pandemic. VOCs in exhaled breath were compared between PCR-positive and negative individuals using TD-GC-ToF-MS. Candidate VOCs were tested in an independent set of samples collected during the Omicron phase of the pandemic. FINDINGS: Fifty breath samples from symptomatic RT-qPCR positive and 58 breath samples from test-negative, but symptomatic participants were compared. Of the 50 RT-qPCR-positive participants, 22 had breath sampling repeated 8-12 weeks later. PCA-X model yielded 12 distinct VOCs that discriminated SARS-CoV-2 active infection compared to recovery/convalescence period, with an area under the receiver operator characteristic curve (AUROC), of 0.862 (0.747-0.977), sensitivity, and specificity of 82% and 86%, respectively. PCA-X model from 50 RT-qPCR positive and 58 negative symptomatic participants, yielded 11 VOCs, with AUROC of 0.72 (0.604-0.803) and sensitivity of 72%, specificity 65.5%. The 11 VOCs were validated in a separate group of SARS-CoV-2 Omicron positive patients' vs healthy controls demonstrating an AUROC of 0.96 (95% CI 0.827-0.993) with sensitivity of 80% specificity of 90%. INTERPRETATION: Exhaled breath analysis is a promising non-invasive, point-of-care method to detect mild COVID-19 infection. FUNDING: Funding for this study was a competitive grant awarded from the Vancouver Coastal Research Institute as well as funding from the BC Cancer Foundation.


COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2 , COVID-19 Testing , Pandemics , Prospective Studies , Breath Tests/methods
3.
J Breath Res ; 16(3)2022 05 26.
Article En | MEDLINE | ID: mdl-35508103

ThePeppermint Initiativeseeks to inform the standardisation of breath analysis methods. FivePeppermint Experimentswith gas chromatography-ion mobility spectrometry (GC-IMS), operating in the positive mode with a tritium3H 5.68 keV, 370 MBq ionisation source, were undertaken to provide benchmarkPeppermint Washoutdata for this technique, to support its use in breath-testing, analysis, and research. Headspace analysis of a peppermint-oil capsule by GC-IMS with on-column injection (0.5 cm3) identified 12 IMS responsive compounds, of which the four most abundant were: eucalyptol;ß-pinene;α-pinene; and limonene. Elevated concentrations of these four compounds were identified in exhaled-breath following ingestion of a peppermint-oil capsule. An unidentified compound attributed as a volatile catabolite of peppermint-oil was also observed. The most intense exhaled peppermint-oil component was eucalyptol, which was selected as a peppermint marker for benchmarking GC-IMS. Twenty-five washout experiments monitored levels of exhaled eucalyptol, by GC-IMS with on-column injection (0.5 cm3), att= 0 min, and then att+ 60,t+ 90,t+ 165,t+ 285 andt+ 360 min from ingestion of a peppermint capsule resulting in 148 peppermint breath analyses. Additionally, thePeppermint Washoutdata was used to evaluate clinical deployments with a further five washout tests run in clinical settings generating an additional 35 breath samples. Regression analysis yielded an average extrapolated time taken for exhaled eucalyptol levels to return to baseline values to be 429 ± 62 min (±95% confidence-interval). The benchmark value was assigned to the lower 95% confidence-interval, 367 min. Further evaluation of the data indicated that the maximum number of volatile organic compounds discernible from a 0.5 cm3breath sample was 69, while the use of an in-line biofilter appeared to reduce this to 34.


Mentha piperita , Volatile Organic Compounds , Breath Tests/methods , Eucalyptol/analysis , Gas Chromatography-Mass Spectrometry/methods , Humans , Ion Mobility Spectrometry , Mentha piperita/chemistry , Volatile Organic Compounds/analysis
4.
J Breath Res ; 16(1)2021 12 02.
Article En | MEDLINE | ID: mdl-34724656

The development of clinical breath-analysis is confounded by the variability of background volatile organic compounds (VOCs). Reliable interpretation of clinical breath-analysis at individual, and cohort levels requires characterisation of clinical-VOC levels and exposures. Active-sampling with thermal-desorption/gas chromatography-mass spectrometry recorded and evaluated VOC concentrations in 245 samples of indoor air from three sites in a large National Health Service (NHS) provider trust in the UK over 27 months. Data deconvolution, alignment and clustering isolated 7344 features attributable to VOC and described the variability (composition and concentration) of respirable clinical VOC. 328 VOC were observed in more than 5% of the samples and 68 VOC appeared in more than 30% of samples. Common VOC were associated with exogenous and endogenous sources and 17 VOC were identified as seasonal differentiators. The presence of metabolites from the anaesthetic sevoflurane, and putative-disease biomarkers in room air, indicated that exhaled VOC were a source of background-pollution in clinical breath-testing activity. With the exception of solvents, and waxes associated with personal protective equipment (PPE), exhaled VOC concentrations above 3µg m-3are unlikely to arise from room air contamination, and in the absence of extensive survey-data, this level could be applied as a threshold for inclusion in studies, removing a potential environmental confounding-factor in developing breath-based diagnostics.


Air Pollutants , Air Pollution, Indoor , Volatile Organic Compounds , Air Pollutants/analysis , Air Pollution, Indoor/analysis , Breath Tests , Environmental Monitoring/methods , Exhalation , Humans , State Medicine , Volatile Organic Compounds/analysis
5.
BMC Bioinformatics ; 21(1): 556, 2020 Dec 02.
Article En | MEDLINE | ID: mdl-33267792

BACKGROUND: Data handling in clinical bioinformatics is often inadequate. No freely available tools provide straightforward approaches for consistent, flexible metadata collection and linkage of related experimental data generated locally by vendor software. RESULTS: To address this problem, we created LabPipe, a flexible toolkit which is driven through a local client that runs alongside vendor software and connects to a light-weight server. The toolkit allows re-usable configurations to be defined for experiment metadata and local data collection, and handles metadata entry and linkage of data. LabPipe was piloted in a multi-site clinical breathomics study. CONCLUSIONS: LabPipe provided a consistent, controlled approach for handling metadata and experimental data collection, collation and linkage in the exemplar study and was flexible enough to deal effectively with different data handling challenges.


Computational Biology/methods , Metadata , Data Analysis , Humans , Software
6.
EClinicalMedicine ; 29: 100609, 2020 Dec.
Article En | MEDLINE | ID: mdl-33134902

BACKGROUND: There is an urgent need to rapidly distinguish COVID-19 from other respiratory conditions, including influenza, at first-presentation. Point-of-care tests not requiring laboratory- support will speed diagnosis and protect health-care staff. We studied the feasibility of using breath-analysis to distinguish these conditions with near-patient gas chromatography-ion mobility spectrometry (GC-IMS). METHODS: Independent observational prevalence studies at Edinburgh, UK, and Dortmund, Germany, recruited adult patients with possible COVID-19 at hospital presentation. Participants gave a single breath-sample for VOC analysis by GC-IMS. COVID-19 infection was identified by transcription polymerase chain reaction (RT- qPCR) of oral/nasal swabs together with clinical-review. Following correction for environmental contaminants, potential COVID-19 breath-biomarkers were identified by multi-variate analysis and comparison to GC-IMS databases. A COVID-19 breath-score based on the relative abundance of a panel of volatile organic compounds was proposed and tested against the cohort data. FINDINGS: Ninety-eight patients were recruited, of whom 21/33 (63.6%) and 10/65 (15.4%) had COVID-19 in Edinburgh and Dortmund, respectively. Other diagnoses included asthma, COPD, bacterial pneumonia, and cardiac conditions. Multivariate analysis identified aldehydes (ethanal, octanal), ketones (acetone, butanone), and methanol that discriminated COVID-19 from other conditions. An unidentified-feature with significant predictive power for severity/death was isolated in Edinburgh, while heptanal was identified in Dortmund. Differentiation of patients with definite diagnosis (25 and 65) of COVID-19 from non-COVID-19 was possible with 80% and 81.5% accuracy in Edinburgh and Dortmund respectively (sensitivity/specificity 82.4%/75%; area-under-the-receiver- operator-characteristic [AUROC] 0.87 95% CI 0.67 to 1) and Dortmund (sensitivity / specificity 90%/80%; AUROC 0.91 95% CI 0.87 to 1). INTERPRETATION: These two studies independently indicate that patients with COVID-19 can be rapidly distinguished from patients with other conditions at first healthcare contact. The identity of the marker compounds is consistent with COVID-19 derangement of breath-biochemistry by ketosis, gastrointestinal effects, and inflammatory processes. Development and validation of this approach may allow rapid diagnosis of COVID-19 in the coming endemic flu seasons. FUNDING: MR was supported by an NHS Research Scotland Career Researcher Clinician award. DMR was supported by the University of Edinburgh ref COV_29.

7.
J Breath Res ; 15(1): 016004, 2020 10 24.
Article En | MEDLINE | ID: mdl-33103660

Radiation dose is important in radiotherapy. Too little, and the treatment is not effective, too much causes radiation toxicity. A biochemical measurement of the effect of radiotherapy would be useful in personalisation of this treatment. This study evaluated changes in exhaled breath volatile organic compounds (VOC) associated with radiotherapy with thermal desorption gas chromatography mass-spectrometry followed by data processing and multivariate statistical analysis. Further the feasibility of adopting gas chromatography ion mobility spectrometry for radiotherapy point-of-care breath was assessed. A total of 62 participants provided 240 end-tidal 1 dm3 breath samples before radiotherapy and at 1, 3, and 6 h post-exposure, that were analysed by thermal-desorption/gas-chromatography/quadrupole mass-spectrometry. Data were registered by retention-index and mass-spectra before multivariate statistical analyses identified candidate markers. A panel of sulfur containing compounds (thio-VOC) were observed to increase in concentration over the 6 h following irradiation. 3-methylthiophene (80 ng.m-3 to 790 ng.m-3) had the lowest abundance while 2-thiophenecarbaldehyde(380 ng.m-3 to 3.85 µg.m-3) the highest; note, exhaled 2-thiophenecarbaldehyde has not been observed previously. The putative tumour metabolite 2,4-dimethyl-1-heptene concentration reduced by an average of 73% over the same time. Statistical scoring based on the signal intensities thio-VOC and 3-methylthiophene appears to reflect individuals' responses to radiation exposure from radiotherapy. The thio-VOC are hypothesised to derive from glutathione and Maillard-based reactions and these are of interest as they are associated with radio-sensitivity. Further studies with continuous monitoring are needed to define the development of the breath biochemistry response to irradiation and to determine the optimum time to monitor breath for radiotherapy markers. Consequently, a single 0.5 cm3 breath-sample gas chromatography-ion mobility approach was evaluated. The calibrated limit of detection for 3-methylthiophene was 10 µg.m-3 with a lower limit of the detector's response estimated to be 210 fg.s-1; the potential for a point-of-care radiation exposure study exists.


Biomarkers/analysis , Breath Tests/methods , Radiation , Aged , Calibration , Exhalation , Female , Gas Chromatography-Mass Spectrometry , Humans , Male , Middle Aged , Principal Component Analysis , Volatile Organic Compounds/analysis
8.
J Breath Res ; 14(4): 046008, 2020 08 10.
Article En | MEDLINE | ID: mdl-32604084

Sampling of volatile organic compounds (VOCs) has shown promise for detection of a range of diseases but results have proved hard to replicate due to a lack of standardization. In this work we introduce the 'Peppermint Initiative'. The initiative seeks to disseminate a standardized experiment that allows comparison of breath sampling and data analysis methods. Further, it seeks to share a set of benchmark values for the measurement of VOCs in breath. Pilot data are presented to illustrate the standardized approach to the interpretation of results obtained from the Peppermint experiment. This pilot study was conducted to determine the washout profile of peppermint compounds in breath, identify appropriate sampling time points, and formalise the data analysis. Five and ten participants were recruited to undertake a standardized intervention by ingesting a peppermint oil capsule that engenders a predictable and controlled change in the VOC profile in exhaled breath. After collecting a pre-ingestion breath sample, five further samples are taken at 2, 4, 6, 8, and 10 h after ingestion. Samples were analysed using ion mobility spectrometry coupled to multi-capillary column and thermal desorption gas chromatography mass spectrometry. A regression analysis of the washout data was used to determine sampling times for the final peppermint protocol, and the time for the compound measurement to return to baseline levels was selected as a benchmark value. A measure of the quality of the data generated from a given technique is proposed by comparing data fidelity. This study protocol has been used for all subsequent measurements by the Peppermint Consortium (16 partners from seven countries). So far 1200 breath samples from 200 participants using a range of sampling and analytical techniques have been collected. The data from the consortium will be disseminated in subsequent technical notes focussing on results from individual platforms.


Breath Tests/methods , Mentha piperita/chemistry , Volatile Organic Compounds/chemistry , Benchmarking , Female , Humans , Male
9.
J Breath Res ; 13(4): 046013, 2019 09 30.
Article En | MEDLINE | ID: mdl-31342933

Compact mass spectrometry (CMS) is a versatile and transportable analytical instrument that has the potential to be used in clinical settings to quickly and non-invasively detect a wide range of relevant conditions from breath samples. The purpose of this study is to optimise data preprocessing protocols by three proposed methods of breath sampling, using the CMS. It also lays out a general framework for which data processing methods can be evaluated. METHODS: This paper considers data from three previous studies, each using a different breath sampling method. These include a peppermint washout study using continuous breath sampling with a purified air source, an exercise study using continuous breath sampling with an ambient air source, and a single breath sampling study with an ambient air source. For each dataset, different breath selection (data preprocessing) methods were compared and benchmarked according to predictive performance on a validation set and quantitative reliability of m/z bin intensity measurements. RESULTS: For both continuous methods, the best breath selection method improved the predictive model compared to no preselection, as measured by the 95% CI range for Youden's index, from 0.68-0.86 to 0.86-0.97 for the exercise study and 0.69-0.82 to 1.00-1.00 for the peppermint study. The reliability of intensity measurements for both datasets (as measured by median relative standard deviation (RSD)), was improved slightly by the best selection method compared to no preselection, from 18% to 14% for the exercise study and 7%-5% for the peppermint study. For the single breath samples, all the models resulted in perfect prediction, with a 95% CI range for Youden's index of 1.00-1.00. The reliability of the proposed method was 38%. CONCLUSION: The method of selecting exhaled breath from CMS data can affect the reliability of the measurement and the ability to distinguish between breath samples taken under different conditions. The application of appropriate data processing methods can improve the quality of the data and results obtained from CMS. The methods presented will enable untargeted analysis of breath VOCs using CMS to be performed.


Breath Tests/methods , Mass Spectrometry/methods , Adolescent , Adult , Exercise/physiology , Exhalation/physiology , Humans , Male , Mentha piperita , Models, Theoretical , Plant Oils/chemistry , Reproducibility of Results , Volatile Organic Compounds/analysis , Young Adult
10.
BMJ Open ; 9(3): e025486, 2019 03 08.
Article En | MEDLINE | ID: mdl-30852546

INTRODUCTION: Patients presenting with acute undifferentiated breathlessness are commonly encountered in admissions units across the UK. Existing blood biomarkers have clinical utility in distinguishing patients with single organ pathologies but have poor discriminatory power in multifactorial presentations. Evaluation of volatile organic compounds (VOCs) in exhaled breath offers the potential to develop biomarkers of disease states that underpin acute cardiorespiratory breathlessness, owing to their proximity to the cardiorespiratory system. To date, there has been no systematic evaluation of VOC in acute cardiorespiratory breathlessness. The proposed study will seek to use both offline and online VOC technologies to evaluate the predictive value of VOC in identifying common conditions that present with acute cardiorespiratory breathlessness. METHODS AND ANALYSIS: A prospective real-world observational study carried out across three acute admissions units within Leicestershire. Participants with self-reported acute breathlessness, with a confirmed primary diagnosis of either acute heart failure, community-acquired pneumonia and acute exacerbation of asthma or chronic obstructive pulmonary disease will be recruited within 24 hours of admission. Additionally, school-age children admitted with severe asthma will be evaluated. All participants will undergo breath sampling on admission and on recovery following discharge. A range of online technologies including: proton transfer reaction mass spectrometry, gas chromatography ion mobility spectrometry, atmospheric pressure chemical ionisation-mass spectrometry and offline technologies including gas chromatography mass spectroscopy and comprehensive two-dimensional gas chromatography-mass spectrometry will be used for VOC discovery and replication. For offline technologies, a standardised CE-marked breath sampling device (ReCIVA) will be used. All recruited participants will be characterised using existing blood biomarkers including C reactive protein, brain-derived natriuretic peptide, troponin-I and blood eosinophil levels and further evaluated using a range of standardised questionnaires, lung function testing, sputum cell counts and other diagnostic tests pertinent to acute disease. ETHICS AND DISSEMINATION: The National Research Ethics Service Committee East Midlands has approved the study protocol (REC number: 16/LO/1747). Integrated Research Approval System (IRAS) 198921. Findings will be presented at academic conferences and published in peer-reviewed scientific journals. Dissemination will be facilitated via a partnership with the East Midlands Academic Health Sciences Network and via interaction with all UK-funded Medical Research Council and Engineering and Physical Sciences Research Council molecular pathology nodes. TRIAL REGISTRATION NUMBER: NCT03672994.


Cardiovascular Diseases/diagnosis , Dyspnea/diagnosis , Multicenter Studies as Topic/methods , Observational Studies as Topic/methods , Volatile Organic Compounds/analysis , Acute Disease , Adult , Breath Tests , Data Collection , Diagnosis, Differential , Exhalation , Gas Chromatography-Mass Spectrometry , Humans , Prospective Studies , Respiratory Tract Diseases/diagnosis , Sample Size , Sputum
11.
J Chromatogr A ; 1594: 160-172, 2019 Jun 07.
Article En | MEDLINE | ID: mdl-30755317

Precision medicine has spurred new innovations in molecular pathology leading to recent advances in the analysis of exhaled breath as a non-invasive diagnostic tool. Volatile organic compounds (VOCs) detected in exhaled breath have the potential to reveal a wealth of chemical and metabolomic information. This study describes the development of a method for the analysis of breath, based on automated thermal desorption (TD) combined with flow modulated comprehensive two-dimensional gas chromatography (GC×GC) with dual flame ionisation and quadrupole mass spectrometric detection (FID and qMS). The constrained optimisation and analytical protocol was designed to meet the practical demands of a large-scale multi-site clinical study, while maintaining analytical rigour to produce high fidelity data. The results demonstrate a comprehensive method optimisation for the collection and analysis of breath VOCs by GC×GC, integral to the standardisation and integration of breath analysis within large clinical studies.


Breath Tests/methods , Clinical Studies as Topic/methods , Flame Ionization , Gas Chromatography-Mass Spectrometry , Volatile Organic Compounds/analysis , Humans , Reference Standards
12.
Bioanalysis ; 8(13): 1325-36, 2016 Jul.
Article En | MEDLINE | ID: mdl-27277875

AIM: Breath analyses have potential to detect early signs of disease onset. Ambient ionization allows direct combination of breath gases with MS for fast, on-line analysis. Portable MS systems would facilitate field/clinic-based breath analyses. Results & methodology: Volunteers ingested peppermint oil capsules and exhaled volatile compounds were monitored over 10 h using a compact mass spectrometer. A rise and fall in exhaled menthone was observed, peaking at 60-120 min. Real-time analysis showed a gradual rise in exhaled menthone postingestion. Sensitivity was comparable to established methods, with detection in the parts per trillion range. CONCLUSION: Breath volatiles were readily analyzed on a portable mass spectrometer through a simple inlet modification. Induced changes in exhaled profiles were detectable with high sensitivity and measurable in real-time.


Breath Tests/instrumentation , Mass Spectrometry/instrumentation , Menthol/analysis , Plant Oils/analysis , Volatile Organic Compounds/analysis , Adult , Atmospheric Pressure , Equipment Design , Exhalation , Female , Humans , Male , Mentha piperita , Menthol/metabolism , Middle Aged , Plant Oils/administration & dosage , Plant Oils/metabolism , Point-of-Care Systems , Respiration , Volatile Organic Compounds/metabolism , Young Adult
13.
Analyst ; 137(6): 1458-65, 2012 Mar 21.
Article En | MEDLINE | ID: mdl-22318171

A piezoelectric injector has been interfaced to a differential mobility spectrometer to enable fast and reversible control of dopant/transport-gas modifier levels within the reaction region of the instrument. Operating at 1 Hz with optimised bipolar waveforms for the piezoelectric injector and gas flows within the injector, steady-state 2-butanol mass fluxes of 21 to 1230 ng min(-1) and 1-bromohexane mass fluxes of 149 to 2644 ng min(-1) were delivered to the differential mobility cell. Control of split-flow and transport-gas flow rates enabled rapid and flexible control of the dopant concentrations. The system was consistently reproducible with a relative standard deviation (RSD) of 7.9% at every mass- flux level studied. Stable responses were achieved between 3 to 5 s following a change in the control levels and no significant hysteresis effects were observed. In the positive mode it was possible to control the extent of formation protonated monomer and proton bound cluster ions, tentatively assigned to{C(4)H(9)OH(H(2)O)(n)H}(+) and {(C(4)H(9)OH)(2)(H(2)O)(n)H}(+) and similar control was possible in the negative mode where the concentration relationship for the formation of bromide clusters indicated the presence of multiple ionisation mechanisms. A dopant formulation for the simultaneous control of ions in both the positive and negative modes was demonstrated by the injection of a 50%/50% v/v solution of 2-butanol/1-bromohexane with mass fluxes of 2-butanol in the mixture of between 11 and 1161 ng min(-1) and between 13 and 1325 ng min(-1) for 1-bromohexane.

...